ISO 22785-8:2026
(Main)Paints and varnishes — Coatings on plastics and composites — Part 8: Film thickness
- Abstract
This document specifies the determination of the film thickness of coatings on plastics, plastic composites and similar substrates. It also provides an overview of common test methods for determination of wet-film thickness and dry-film thickness.
- Status
- Published
- Publication Date
- 15-Nov-2026
- Technical Committee
- ISO/TC 35/SC 9 - General test methods for paints and varnishes
- Drafting Committee
- ISO/TC 35/SC 9/WG 31 - Properties after application
- Current Stage
- 6060 - International Standard published
- Start Date
- 16-Nov-2026
- Completion Date
- 16-Nov-2026
ISO 22785-8:2026 is an ISO International Standard for measuring the film thickness of coatings on plastics, plastic composites and similar substrates. It specifies how to determine wet-film thickness and dry-film thickness, and it gives an overview of common test methods for both. It is written for people who need to choose, carry out, or interpret thickness measurements on coated plastic-based parts and test panels.
What does ISO 22785-8:2026 specify?
ISO 22785-8:2026 specifies the determination of film thickness for coatings on plastics, plastic composites and similar substrates. It also organizes the subject into practical measurement routes for wet-film thickness and dry-film thickness, so users can match the method to the coating system and the test object.
The document is arranged in six clauses, plus a bibliography:
- Clause 1 Scope
- Clause 2 Normative references
- Clause 3 Terms and definitions
- Clause 4 Test specimen characteristics and preparation
- Clause 5 Determination of wet-film thickness
- Clause 6 Determination of dry-film thickness
In practice, that structure takes the reader from specimen preparation to the available measurement methods, then to the details needed to select and run a test.
What are the key requirements of ISO 22785-8:2026?
ISO 22785-8:2026 is built around practical measurement choices. The main technical point is that plastics behave differently from metallic substrates, so the document relies on methods that suit non-conductive, non-magnetic substrates and gives guidance on when each method is usable.
Specimen preparation matters before any measurement
Clause 4.1 says coatings on both test specimen panels, as specified in ISO 1514, and on components are tested. The geometry depends on the chosen method, so the specimen has to suit the instrument or procedure being used.
Clause 4.2 says conditioning is important for repeatability and reproducibility, and plastics often need longer conditioning than metals because humidity affects them more strongly. In practice, this means the user should control the specimen state before measuring, not just the coating itself.
Wet-film thickness can be measured by several routes
Clause 5.1 covers mechanical methods, including the wet film comb, wheel gauge and dial gauge. These methods are suitable for all film-substrate combinations where the surface is flat in at least one direction, and they are normally used immediately after application because drying, curing or solvent loss can change the reading. The clause also warns that pigment particles can make the displayed value lower than the true wet-film thickness, which matters when comparing readings across batches or methods.
Clause 5.2 describes the gravimetric method for wet-film thickness. ISO 22785-8:2026 says it is generally applicable when the liquid coating contains no or only a small proportion of volatile components, and it yields the mean thickness over the entire coated area. For sprayed coatings, the reverse side is masked to avoid overspray affecting the mass measurement.
Clause 5.3 covers the photothermal method. ISO 22785-8:2026 says it is basically suitable for all film-substrate combinations and can also be used for individual layers in multilayer coatings when the layers are sufficiently different in thermal conductivity and reflection properties. The instrument has to be calibrated with reference materials for each film-substrate combination, so users need reference samples and controlled settings, not just the test instrument.
Dry-film thickness has more method choices, including referee and layer-specific methods
Clause 6.1 covers mechanical methods for dry-film thickness. ISO 22785-8:2026 describes two ways to determine thickness from the difference between substrate thickness and total thickness: before and after coating removal, or before and after coating application. The coating application variant is preferred for plastics because exposing the substrate can damage it. The profilometer is identified as the referee method in the event of a dispute, so it is the method to rely on when results are questioned.
Clause 6.2 gives a gravimetric dry-film method. It calculates dry-film thickness from the mass difference, the coated area and the dry-film density. The document says the method yields the mean thickness over the whole coated surface, and spray-coated specimens may need masking on the reverse side. For users, this means the method is good for average coating loading, but not for local variation.
Clause 6.3 sets out optical methods: cross-grinding/cross-sectioning, wedge cut, and beta backscatter. These methods are used when a direct view of the film or a defined cut can be made. The wedge cut method uses a measured cut angle and the projected half-width of the cut, while beta backscatter uses a source, detector and reference standards with preferably the same composition as the specimen. That makes the optical route useful when a visual or radiation-based cross-check is needed.
Clause 6.4 covers another photothermal method for dry-film thickness. Like the wet-film version, it depends on thermal excitation and detection, and the measurement system is verified with reference materials for each film-substrate combination, especially each film material. This matters when thickness must be determined without cutting the coating.
Clause 6.5 describes the acoustic method, which derives thickness from ultrasonic travel times. It is suitable when the speed of sound is uniform within each coat and differs clearly from adjacent layers and the substrate. In practice, coatings with inhomogeneities, and substrates with grain or other structure, can affect the result.
Clause 6.6 covers the terahertz method for multilayer systems. ISO 22785-8:2026 says it can be used when the layers are transparent to terahertz radiation and their refractive index and extinction coefficient differ enough to separate them. The minimum detectable thickness is about 5 µm, with the actual range depending on the material and the instrument.
What terms does ISO 22785-8:2026 define?
ISO 22785-8:2026 uses these key terms in clause 3, alongside the vocabulary from ISO 4618 and ISO 22785-1:
- Film thickness - the distance between the film surface and the substrate surface.
- Wet-film thickness - the thickness of a freshly applied coating measured immediately after application.
- Dry-film thickness - the thickness of the coating that remains after it has hardened.
- Test area - a representative part of the surface where a defined number of single measurements is taken as a spot-check.
These terms matter because the document uses them to separate average coating condition, local spot measurements, and the timing of the measurement.
Who uses ISO 22785-8:2026?
ISO 22785-8:2026 is used by coating laboratories, paint and varnish producers, quality control teams, and inspectors who measure coatings on plastics and composite parts. It is also useful for manufacturers and buyers who need a shared method for checking whether a coating has been applied at the intended thickness.
It is especially relevant when the coating system is evaluated on test panels, on shaped components, or on multilayer coatings. That makes it practical for production control, incoming inspection, development work, and dispute resolution.
Which standards are used with ISO 22785-8:2026?
| Standard | What it contributes |
|---|---|
| ISO 4618 | Core paint and varnish vocabulary used by clause 3 |
| ISO 22785-1 | General introduction to coatings on plastics and composites |
| ISO 1514 | Standard panels for testing, referenced for test specimens |
| ISO 463 | Requirements for mechanical dial gauges used in several methods |
| ISO 2808:2019 | Source for several thickness terms and definitions |
| ISO 2811-1, ISO 2811-2, ISO 2811-3, ISO 2811-4 | Density of liquid coating material for wet-film gravimetric calculation |
| ISO 3233-1, ISO 3233-2, ISO 3233-3 | Dry-film density for gravimetric dry-film calculation |
| ISO 19397 | Ultrasonic gauge method, relevant to the acoustic approach |
| EN 15042-2 | Guidance for photothermal thickness measurement |
What does the ISO 22785-8:2026 document contain?
ISO 22785-8:2026 contains method descriptions, instrument descriptions, and step-by-step procedures for wet-film and dry-film thickness measurement on plastics and composites. It includes formulas for gravimetric calculations and for the wedge cut method, so users can calculate thickness from mass, area, density, or cut geometry.
The document also includes figures that illustrate the comb gauge, wheel gauge, dial gauge, photothermal detection, ultrasonic measurement, and terahertz measurement. Those figures help the reader understand how the measurement is made and where the reading is taken.
For the optical and mechanical routes, the text describes specimen preparation, sectioning or cutting, microscopy, and profile reading. For the electronic and wave-based routes, it describes calibration, verification, reference materials, and the conditions that affect whether the method is suitable for the coating system in question.
Get Certified
Connect with accredited certification bodies for this standard
DIN CERTCO
DIN Group product certification.

Smithers Quality Assessments
US management systems and product certification.
Sponsored listings
Frequently Asked Questions
ISO 22785-8:2026 is a standard published by the International Organization for Standardization (ISO). Its full title is "Paints and varnishes — Coatings on plastics and composites — Part 8: Film thickness". This standard covers: This document specifies the determination of the film thickness of coatings on plastics, plastic composites and similar substrates. It also provides an overview of common test methods for determination of wet-film thickness and dry-film thickness.
This document specifies the determination of the film thickness of coatings on plastics, plastic composites and similar substrates. It also provides an overview of common test methods for determination of wet-film thickness and dry-film thickness.
ISO 22785-8:2026 is classified under the following ICS (International Classification for Standards) categories: 83.080.01 - Plastics in general; 83.120 - Reinforced plastics; 87.040 - Paints and varnishes. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO 22785-8:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
International
Standard
ISO 22785-8
First edition
Paints and varnishes — Coatings on
2026-11
plastics and composites —
Part 8:
Film thickness
Reference number
© ISO 2026
All rights reserved.
This ISO publication is protected by copyright and is owned by ISO and/or its licensors.
The content of this ISO publication is provided under licence, not sold. Use is subject to the applicable licence terms issued by ISO,
an ISO member body, or an authorized third-party distributor.
Except as required for implementation or expressly permitted by a separate licence, no part of this ISO publication may be
reproduced, distributed, modified, used, or made available in any form or by any means – electronic or mechanical, including
photocopying, scanning, recording, or posting on internal or external digital platforms.
Any use beyond the scope of the granted rights is prohibited and may result in legal action.
ISO copyright office
CP 401 • CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii
Contents Page
Foreword .v
Introduction .vi
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Test specimen characteristics and preparation . 2
4.1 Test specimens.2
4.2 Conditioning.2
5 Determination of wet-film thickness . 2
5.1 Mechanical methods .2
5.1.1 Principle .2
5.1.2 Field of application .2
5.1.3 General .2
5.1.4 Wet film comb .3
5.1.5 Wheel gauge .4
5.1.6 Dial gauge.5
5.2 Gravimetric method .6
5.2.1 Principle .6
5.2.2 Field of application .7
5.2.3 General .7
5.2.4 Procedure .7
5.3 Photothermal method .7
5.3.1 Principle .7
5.3.2 Field of application .8
5.3.3 General .8
5.3.4 Instrument and reference materials (reference samples) .8
5.3.5 Calibration . . .8
5.3.6 Procedure .9
6 Determination of dry-film thickness . 9
6.1 Mechanical methods .9
6.1.1 Principle .9
6.1.2 Filed of application .9
6.1.3 General .9
6.1.4 Dial gauge.10
6.1.5 Dial depth gauge .11
6.1.6 Profilometer . 12
6.2 Gravimetric method . 13
6.2.1 Principle . 13
6.2.2 Field of application .14
6.2.3 General .14
6.2.4 Procedure .14
6.3 Optical method .14
6.3.1 Principle .14
6.3.2 Cross-grinding/cross-sectioning . 15
6.3.3 Wedge cut .16
6.3.4 Beta backscatter method .17
6.4 Photothermal method .17
6.4.1 Principle .17
6.4.2 Field of application .18
6.4.3 General .18
6.4.4 Apparatus and reference materials (reference samples) .18
6.4.5 Verification .19
6.4.6 Procedure .19
iii
6.5 Acoustic method . .19
6.5.1 Principle .19
6.5.2 Field of application .19
6.5.3 General .19
6.5.4 Description of the instrument .19
6.5.5 Procedure . 20
6.6 Terahertz method . 20
6.6.1 Principle . 20
6.6.2 Field of application .21
6.6.3 Description of instrument.21
6.6.4 Procedure . 22
Bibliography .23
iv
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee
has been established has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely
with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types
of ISO document should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent
rights in respect thereof. As of the date of publication of this document, ISO had not received notice of (a)
patent(s) which may be required to implement this document. However, implementers are cautioned that
this may not represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO's adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 35, Paints and varnishes, Subcommittee SC 9,
General test methods for paints and varnishes.
A list of all parts in the ISO 22785 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.
v
Introduction
The chemical and physical properties of plastics and composites as substrates are very different from those
of metallic substrates.
In contrast to metals, plastics generally are not electrically conductive and are not magnetic. For this reason,
magnetic and electromagnetic methods cannot be used to measure film thickness on plastic substrates.
vi
International Standard ISO 22785-8:2026(en)
Paints and varnishes — Coatings on plastics and
composites —
Part 8:
Film thickness
1 Scope
This document specifies the determination of the film thickness of coatings on plastics, plastic composites
and similar substrates.
It also provides an overview of common test methods for determination of wet-film thickness and dry-film
thickness.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
ISO 4618, Paints and varnishes — Vocabulary
ISO 22785-1, Coatings on plastics and composites — Part 1: General introduction
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 4618 and ISO 22785-1 and the
following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
3.1
film thickness
distance between the surface of the film and the surface of the substrate
[SOURCE: ISO 2808:2019, 3.1]
3.2
wet-film thickness
thickness of a freshly applied wet coating material, measured immediately after application
[SOURCE: ISO 2808:2019, 3.2]
3.3
dry-film thickness
thickness of a coating remaining on the surface when the coating has hardened
[SOURCE: ISO 2808:2019, 3.3]
3.4
test area
representative part of the relevant surface area, within which an agreed number of single measurements is
made as a spot-check
[SOURCE: ISO 2808:2019, 3.6, modified — Note 1 to entry has been deleted.]
4 Test specimen characteristics and preparation
4.1 Test specimens
Coatings both on test specimen panels as specified in ISO 1514 and on components are tested. Depending on
the selected test method, there are different requirements for the geometry of the test specimen.
Any type of flaw or damage impairs the appearance and properties of the substrate.
The coating system and the substrate are selected together with the pre-treatment and coating methods so
that a homogeneous coating is achieved. The film thickness is documented in accordance with the technical
requirements relating to the visual appearance and/or coating.
4.2 Conditioning
Conditioning serves to improve the repeatability and reproducibility of test results.
As the properties of plastics substrates depend greatly on humidity levels and conditioning usually takes
longer than for metals, a longer conditioning time is usually required for plastics substrates.
The values and times to be selected depend on the test specimen to be tested.
5 Determination of wet-film thickness
5.1 Mechanical methods
5.1.1 Principle
With mechanical procedures, the measuring instrument (see Figures 1, 2 and 3, Key 4) passes through by the
coating being placed on the surface of the substrate. The difference between the points of contact (substrate,
see Figures 1, 2 and 3, Key 1) and the coating surface touched from the top of the measurement instrument
(Figures 1, 2 and 3, Key 3) corresponds to the readable wet-film thickness.
5.1.2 Field of application
The mechanical principle is suitable for all film-substrate combinations. The substrate is flat in at least one
direction in the area where the measurement is performed. Curvature of the surface in a single plane is
permissible (e.g. internal or external surface of pipes).
5.1.3 General
The classification as a destructive or non-destructive process depends on
a) the rheological properties of the coating material;
b) the nature of the wetting contact between the contact surfaces of the measurement instrument and the
coating material;
c) whether the thickness measurements will make the coating unsuitable for the purpose for which it is
intended.
Since the possibility of pigment particles remaining between the gauge and the substrate cannot be excluded,
all mechanical methods contain a systematic error: the film thickness displayed is smaller than the actual
wet-film thickness by at least the mean diameter of the pigment particles.
In the case of a wheel gauge (5.1.5), the wheel is wetted by the coating material. If not, this represents a
further source of systematic error which can result in exaggerated readings and is a function of:
— the surface tension and the rheological properties of the coating material;
— the material of the wheel gauge;
— the speed at which the wheel is turned.
5.1.4 Wet film comb
5.1.4.1 Description of instrument
A comb gauge is a flat plate made of a corrosion-resistant material with teeth along its edges (see Figure 1).
The reference teeth at the corners of the plate specifies a baseline along which the inner teeth are arranged
to give a graduated series of gaps. Each tooth is labelled with the assigned gap value.
With commercially available comb gauges, the maximum thickness which can be measured is typically
2 000 µm and the smallest increment is typically 5 µm.
Dimensions in micrometres
Key
1 substrate
2 coating
3 point of wetting contact
4 comb gauge
Figure 1 — Example of a comb gauge
5.1.4.2 Procedure
As the first step, it is ensured that the teeth are clean and not worn out or damaged. The comb gauge is
placed onto the flat specimen surface such that the teeth are normal to the plane of the surface. Sufficient
time is allowed for the coating to wet the teeth prior to removing the gauge.
In the case of specimens curved in a single plane, the comb gauge is placed in position parallel to the axis of
curvature.
The thickness is measured directly after application since the result can be influenced, for example, by
physical drying, curing or solvent loss.
The greatest gap reading of the tooth wetted by the coating material is taken as the wet-film thickness.
5.1.5 Wheel gauge
5.1.5.1 Description of instrument
A wheel gauge consists of a wheel, made of hardened and corrosion-resistant steel, with three projecting
rims (see Figure 2).
Two rims are ground to the same diameter and are configured concentrically to the wheel axle. The third
rim has a smaller diameter and is eccentrically ground. One of the outer rims has a scale from which the
respective protrusion of the concentric rims relative to the eccentric rim can be read.
Two versions are available:
— version 1 has the eccentric rim located between the concentric rims;
— version 2 has the eccentric rim located systematically outside the concentric rims and closely adjacent to
one of them.
Unlike version 1, the design of version 2 allows parallax-free reading of the wet-film thickness.
With commercially available wheel gauges, the maximum thickness which can be measured is typically
1 500 µm and the smallest increment is typically 2 µm.
Key
1 substrate
2 coating
3 eccentric wheel
4 wheel gauge
Figure 2 — Wheel gauge
5.1.5.2 Procedure
The wheel gauge is griped with the thumb and index finger by the wheel axle and the concentric rims are
pressed onto the surface at the point of the largest reading on the scale.
In the case of specimens curved in a single plane, the axis of curvature and the wheel gauge axle are parallel.
The wheel gauge is rolled in one direction, lifted from the surface and the highest scale reading at which the
eccentric rim is still wetted by the coating material is read off. The gauge is cleaned and the measurement is
repeated in the other direction.
The wet-film thickness is calculated as the arithmetic mean of these readings.
The thickness is measured directly after application since the result can be influenced, for example, by
physical drying, curing or solvent loss.
To minimize the influence of surface tension on the measurement result, the wetting process is observed
directly, and the scale reading is taken at the moment of initial wetting. This is only possible with version 2
of the wheel gauge.
5.1.6 Dial gauge
5.1.6.1 Instrument and reference material (reference standard)
Analogue dial gauges conforming to the requirements of ISO 463 [see Figure 3 a)] are typically capable of
measuring to an accuracy of 5 µm and digital dial gauges [see Figure 3 b)] to an accuracy of 1 µm, or greater.
The gauge can have an analogue or digital display.
The underside of the dial gauge has two contact pins of equal length located equidistant from the movable
plunger and in a straight line with it. An adjusting screw is used to make careful adjustments to the position
of the plunger in its guideway.
a) Analogue dial gauge
b) Digital dial gauge
Key
1 substrate
2 coating
3 plunger
Figure 3 — Examples of an analogue dial gauge and a digital dial gauge
A flat reference plate is required for zeroing the gauge. The reference plate shall be a polished glass plate.
5.1.6.2 Procedure
The dial gauge is zeroed on the reference plate with the measuring tip adjusted so that it is just touching the
plate.
The plunger is screwed back from the zeroing position.
The contact pins of the dial gauge are placed on the specimen so that they are perpendicular to the surface of
the substrate and the plunger is carefully lowered down until the measuring tip is just touching the coating
material.
In the case of specimens curved in a single plane, the plungers are placed in position parallel to the axis of
curvature.
The thickness is measured directly after application since the result can be influenced, for example, by
physical drying, curing or solvent loss.
The wet-film thickness is read directly from the gauge.
5.2 Gravimetric method
5.2.1 Principle
A coating is applied and the thickness is determined by dividing the mass of the coating by its density and by
the coated surface area.
The wet-film thickness, t , in micrometres, is calculated with Formula (1):
w
mm
t (1)
w
A
where
m is the mass of the uncoated test specimen, in grams;
m is the mass of the coated test specimen, in grams;
A is the coated surface, in square metres;
ρ is the density of the liquid coating material applied, in grams per cubic centimetres.
NOTE 1 The density of the liquid coating material applied can be determined according to ISO 2811-1, ISO 2811-2,
ISO 2811-3 or ISO 2811-4.
NOTE 2 For coatings on plastics substrates, the gravimetric method is less precise than the other methods
described in this document.
5.2.2 Field of application
The gravimetric measuring principle is generally applicable, provided the liqui
...