ISO 22188:2023
(Main)Monitoring for inadvertent movement and illicit trafficking of radioactive material
Monitoring for inadvertent movement and illicit trafficking of radioactive material
This document specifies methods and means of monitoring for inadvertent movement and illicit trafficking of radioactive material. It provides guidelines on the use of both stationary and portable, for example hand-held, instruments to monitor for radiation signatures from radioactive material. Emphasis is placed on the operational aspects, i.e., requirements derived for monitoring of traffic and commodities mainly at border-crossing facilities. Although the term border is used repeatedly in this document, it is meant to apply not only to international land borders but also maritime ports, airports, and similar locations where goods or individuals are being checked. This document does not specifically address the issue of detection of radioactive materials at recycling facilities, although it is recognized that transboundary movement of metals for recycling occurs, and that monitoring of scrap metals might be done at the borders of a state. This document is applicable to — regulatory bodies and other competent authorities seeking guidance on implementation of action plans to combat illicit trafficking, — law enforcement agencies, for example border guards, to obtain guidelines on recommended monitoring procedures, — equipment manufacturers in order to understand minimum requirements derived from operational necessities according to this document, and — end-users of radiation detection equipment applicable to this document.
Surveillance des mouvements non déclarés et des trafics illicites de matière radioactive
Le présent document spécifie des méthodes et moyens de surveillance des mouvements non déclarés et des trafics illicites de matière radioactive. Il fournit des lignes directrices d’utilisation d’instruments fixes et mobiles, par exemple des instruments portables, qui permettent de rechercher les signatures de rayonnement de matières radioactives. Il insiste particulièrement sur les aspects opérationnels, c’est-à-dire les exigences établies pour la surveillance de la circulation et des marchandises, surtout au niveau des passages de frontières. Bien que le terme frontière soit fréquemment utilisé dans le présent document, il convient d’indiquer qu’il désigne ici non seulement les frontières terrestres internationales, mais également les ports maritimes, les aéroports et endroits similaires où l’on contrôle des marchandises ou des personnes. Le présent document ne traite pas spécifiquement la question de la détection des matières radioactives au niveau des installations de recyclage bien qu’il soit reconnu que des mouvements transfrontaliers de métaux à recycler interviennent et que la surveillance de métaux de rebut puisse se faire aux frontières d’un État. Le présent document s’applique: — aux organismes de réglementation et aux autres autorités compétentes qui souhaitent obtenir des recommandations sur la mise en œuvre des plans d’action de lutte contre le trafic illicite; — les organismes chargés de l’application de la loi, par exemple les gardes-frontières, afin d’obtenir des lignes directrices sur les procédures de contrôle recommandées; — aux fabricants d’équipements afin de comprendre les exigences minimales découlant des nécessités opérationnelles conformément au présent document; — aux utilisateurs finaux d’équipements de détection de rayonnements applicables au présent document.
General Information
- Status
- Published
- Publication Date
- 22-Aug-2023
- Technical Committee
- ISO/TC 85/SC 2 - Radiological protection
- Drafting Committee
- ISO/TC 85/SC 2 - Radiological protection
- Current Stage
- 6060 - International Standard published
- Start Date
- 23-Aug-2023
- Due Date
- 14-Dec-2023
- Completion Date
- 23-Aug-2023
Relations
- Revises
ISO 22188:2004 - Monitoring for inadvertent movement and illicit trafficking of radioactive material - Effective Date
- 06-Jun-2022
Overview
ISO 22188:2023 - "Monitoring for inadvertent movement and illicit trafficking of radioactive material" provides operational guidance for detecting radioactive materials at borders and other checkpoints. The standard specifies methods and means for both stationary and portable monitoring, emphasizes operational aspects (traffic, commodities, passenger screening) and covers training, instrument use, calibration and maintenance. It is focused on practical radiological monitoring at land borders, seaports, airports and similar control points.
Key topics and technical requirements
- Monitoring methods and procedures for detection, verification, localization and identification of radiation signatures.
- Instrument categories described: personal radiation devices (PRDs), hand-held instruments, hand-held radionuclide identification devices (RIDs), installed radiation portal monitors (RPMs), mobile systems, backpack detectors, and active interrogation / imaging systems.
- Operational requirements: procedure design for checkpoints, search techniques, alarm management, threshold-level considerations and follow-up actions.
- Training: recommended training requirements for border agents, inspectors and first responders to ensure consistent and safe monitoring operations.
- Equipment lifecycle: guidance on operation, calibration, routine testing and maintenance of detection equipment.
- Cyber assurance: Clause 6 addresses computer security and resilience of networked monitoring systems to protect data integrity, availability and authenticity.
- Informative annexes: alarms and threshold levels, lists of possibly trafficked devices and radionuclides, and examples of naturally occurring radioactive materials (NORM).
Note: performance specifications and test methods for instrumentation are covered by referenced IEC standards (see Related Standards).
Applications
ISO 22188:2023 is designed for practical implementation in scenarios such as:
- Border-crossing radiation screening of vehicles, cargo and people
- Port and airport security programs to detect illicit trafficking of radioactive material
- Mobile or ad hoc monitoring during law-enforcement operations and incident response
- Planning and procurement of detection systems and operational procedures
The standard supports consistent, interoperable approaches to detecting inadvertent movements (e.g., contaminated goods, NORM in scrap metal) and deliberate illicit trafficking.
Who should use this standard
- Regulatory bodies and competent authorities developing national action plans against illicit trafficking
- Law enforcement and border agencies (border guards, customs) implementing monitoring procedures
- Manufacturers of radiation detection equipment aligning product features with operational needs
- End-users and facility operators responsible for deploying and maintaining detection systems
Related standards
ISO 22188:2023 references IEC standards for instrument performance and testing, including:
- IEC 60325, IEC 61526, IEC 62244, IEC 62327, IEC 62387, IEC 62401 and IEC 62484
Using ISO 22188:2023 helps organizations establish robust, operationally sound radiation monitoring programs that are interoperable and aligned with international best practice.
ISO 22188:2023 - Monitoring for inadvertent movement and illicit trafficking of radioactive material Released:23. 08. 2023
ISO 22188:2023 - Surveillance des mouvements non déclarés et des trafics illicites de matière radioactive Released:1/29/2024
Get Certified
Connect with accredited certification bodies for this standard

NSF International
Global independent organization facilitating standards development and certification.
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Kiwa BDA Testing
Building and construction product certification.
Sponsored listings
Frequently Asked Questions
ISO 22188:2023 is a standard published by the International Organization for Standardization (ISO). Its full title is "Monitoring for inadvertent movement and illicit trafficking of radioactive material". This standard covers: This document specifies methods and means of monitoring for inadvertent movement and illicit trafficking of radioactive material. It provides guidelines on the use of both stationary and portable, for example hand-held, instruments to monitor for radiation signatures from radioactive material. Emphasis is placed on the operational aspects, i.e., requirements derived for monitoring of traffic and commodities mainly at border-crossing facilities. Although the term border is used repeatedly in this document, it is meant to apply not only to international land borders but also maritime ports, airports, and similar locations where goods or individuals are being checked. This document does not specifically address the issue of detection of radioactive materials at recycling facilities, although it is recognized that transboundary movement of metals for recycling occurs, and that monitoring of scrap metals might be done at the borders of a state. This document is applicable to — regulatory bodies and other competent authorities seeking guidance on implementation of action plans to combat illicit trafficking, — law enforcement agencies, for example border guards, to obtain guidelines on recommended monitoring procedures, — equipment manufacturers in order to understand minimum requirements derived from operational necessities according to this document, and — end-users of radiation detection equipment applicable to this document.
This document specifies methods and means of monitoring for inadvertent movement and illicit trafficking of radioactive material. It provides guidelines on the use of both stationary and portable, for example hand-held, instruments to monitor for radiation signatures from radioactive material. Emphasis is placed on the operational aspects, i.e., requirements derived for monitoring of traffic and commodities mainly at border-crossing facilities. Although the term border is used repeatedly in this document, it is meant to apply not only to international land borders but also maritime ports, airports, and similar locations where goods or individuals are being checked. This document does not specifically address the issue of detection of radioactive materials at recycling facilities, although it is recognized that transboundary movement of metals for recycling occurs, and that monitoring of scrap metals might be done at the borders of a state. This document is applicable to — regulatory bodies and other competent authorities seeking guidance on implementation of action plans to combat illicit trafficking, — law enforcement agencies, for example border guards, to obtain guidelines on recommended monitoring procedures, — equipment manufacturers in order to understand minimum requirements derived from operational necessities according to this document, and — end-users of radiation detection equipment applicable to this document.
ISO 22188:2023 is classified under the following ICS (International Classification for Standards) categories: 13.280 - Radiation protection. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO 22188:2023 has the following relationships with other standards: It is inter standard links to ISO 22188:2004. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ISO 22188:2023 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 22188
Second edition
2023-08
Monitoring for inadvertent movement
and illicit trafficking of radioactive
material
Surveillance des mouvements non déclarés et des trafics illicites de
matière radioactive
Reference number
© ISO 2023
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii
Contents Page
Foreword .iv
Introduction . vi
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 2
4 Monitoring . 4
4.1 Overview . 4
4.2 Training requirements for border agents, inspectors and first responders . 7
4.3 Monitoring instruments . 7
4.3.1 General . 7
4.3.2 Personal radiation devices . 8
4.3.3 Hand-held instruments. 9
4.3.4 Hand-held radionuclide identification devices (RIDs) . 10
4.3.5 Installed radiation portal monitors . 11
4.3.6 Mobile systems . . .13
4.3.7 Backpack-type radiation detectors . 14
4.3.8 Active interrogation and imaging systems . 14
5 Radiation monitoring at checkpoints .15
5.1 General . 15
5.2 Important considerations .15
5.3 Verification . . 16
5.4 Localization . 16
5.5 Identification . 16
5.6 Search techniques, operational response and follow-up . 16
6 Cyber assurance for monitoring instruments .16
6.1 General . 16
6.2 Risk-based good practice . 17
6.3 Operational aspects . 17
Annex A (informative) Alarms and threshold levels .18
Annex B (informative) Possible trafficked devices and radionuclides.22
Annex C (informative) Examples of naturally occurring radioactive materials .23
Bibliography .24
iii
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO document should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use
of (a) patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed
patent rights in respect thereof. As of the date of publication of this document, ISO had not received
notice of (a) patent(s) which may be required to implement this document. However, implementers are
cautioned that this may not represent the latest information, which may be obtained from the patent
database available at www.iso.org/patents. ISO shall not be held responsible for identifying any or all
such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to
the World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see
www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 85, Nuclear energy, nuclear technologies
and radiological protection, Subcommittee SC 2, Radiological protection.
This second edition cancels and replaces the first edition (ISO 22188:2004), which has been technically
revised.
The main changes are as follows:
— Update of the introduction, considering the continuous development of technology.
— Update of Clause 2.
— There were 14 terms and definitions listed in the first edition (ISO 22188:2004). According to
related standards and IAEA technical documents,
— the following terms have been deleted: 3.1 control of radioactive material, 3.9 non-proliferation,
3.10 physical protection, 3.12 response, 3.13 safeguards and 3.14 special nuclear material;
— the following terms have been added: 3.1 check source, 3.2 competent authority, 3.3 computer
security, 3.9 nuclear material, 3.10 radioactive contamination, 3.11 radioactive material,
3.12 radiological monitoring, 3.13 radionuclide, 3.15 threat, 3.16 threat assessment and 3.17
threshold level. Terms and definitions count updated to 17.
— According to the standard’s title, “instruments” in the title of Clause 4 was deleted. Originally, there
were 4 types of instruments categorized in the first edition (ISO 22188:2004); they were pocket-
type instruments, hand-held instruments, installed instruments and radionuclide identifiers. In
this second edition, the kinds of devices are updated to 7. Individually, they are personal radiation
devices, hand-held instruments, hand-held radionuclide identification devices, installed radiation
portal monitors, mobile systems, backpack-type radiation detectors, active interrogation and
iv
imaging systems. For each instrument the general characteristics, operation, calibration and
routine testing, minimum performance requirements and test methods are presented. References
to the IEC standards covering the performance requirements for these types of instruments were
added and the requirements listed in this document were removed.
— This document primarily covers radiological monitoring at borders from a technical and operational
viewpoint. Whether, when or where to establish radiological monitoring at borders should be the
result of a comprehensive national regulatory strategy for radioactive material control. Therefore,
the training requirements for border agents, inspectors and first responders have been added (see
4.2).
— Radiation monitoring systems, particularly those which are networked, connected to the internet or
use cloud services, are vulnerable to a range of cyber threats. The computer security of these systems
seeks to maintain the integrity, accessibility, authenticity and, where required, the confidentiality
of data and instrument control. Guidance from national authorities for computer security should
be sought by end-users for maintaining business continuity and reliability of radiation monitoring
services and systems. A new Clause 6 has been added to deal with this issue.
— Parts of Annex A, and all of Annex B and Annex C were integrated into the text of Clauses 4 and 5
of the revised document. Annex D was eliminated and references to applicable IEC standards were
given for performance requirements and test methods. Annex A was rewritten and simplified as
Alarms and threshold levels. A new Annex B was added to list the possible trafficked devices and
radionuclides. Examples of naturally occurring radioactive material remain as Annex C.
— Update of the Bibliography.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.
v
Introduction
The International Atomic Energy Agency (IAEA) Incident and Trafficking Database (ITDB) system
has been recording incidents of inadvertent movement and illicit trafficking of nuclear and other
radioactive materials since 1995. Although the numbers of reported incidents fluctuate over time, those
related to trafficking or malicious use remain a concern. A small number of these reported incidents
involve seizures of potentially weapons-usable nuclear material, but the majority involve unauthorized
activities including stolen or missing radioactive material and the detection of contaminated
manufactured goods. Examples include unintentional incorporation of radioactive materials into
recycled steel, handling of lost radioactive sources by unsuspecting individuals, and deliberate theft of
radioactive material.
The potential radiological hazard to workers, the general public and the environment caused by
misappropriated radioactive materials adds an additional threat to inadvertent movement and illicit
trafficking. There have been instances in which loss of control over radioactive materials has led to
serious, even fatal, consequences. Detection of radioactive materials at border crossings as well as
maritime ports, airports and inside countries, for example at check points, is therefore an important
issue.
This document addresses the procedural aspects of detecting radioactive materials. The procedural
aspects cover the techniques to search, locate and possibly identify radioactive substances. Guidelines
for appropriate training programs and maintenance of equipment are also considered a relevant aspect.
Instruments used in the process are characterized with respect to minimum requirements in order
to make the recommended procedures applicable. These include personal radiation devices, hand-
held instruments, hand-held radionuclide identification devices, installed radiation portal monitors,
backpack-type radiation detectors, mobile systems, active interrogation, and imaging systems.
Specifications for the minimum performance requirements and test methods for instrumentation are
covered by other existing standards, which are listed in the normative references clause.
Due to advances continually being made in the field of border radiation monitoring equipment, it is
assumed that it can represent a consensus on the minimum specifications presently achievable.
It is assumed that this document will allow more efficient use and operation of existing equipment,
enhance communication across borders, and encourage activities to detect and counteract inadvertent
movement and illicit trafficking of radioactive materials. The benefits thus gained contribute towards
the efforts to counter nuclear weapons proliferation and increase radiation protection. A lack of
standardization can delay implementation of intended activities, specifically if certain parameters, for
example threshold level, are not agreed upon internationally. Technical documents published by the
IAEA in this subject area provide a set of technical specification that can be used in design testing,
qualifying and purchasing border radiation monitoring equipment, they are the basis for recommending
justifiable and agreed specifications and procedures, see References [1], [2], [3], [4], [5], [6] and [7].
vi
INTERNATIONAL STANDARD ISO 22188:2023(E)
Monitoring for inadvertent movement and illicit trafficking
of radioactive material
1 Scope
This document specifies methods and means of monitoring for inadvertent movement and illicit
trafficking of radioactive material. It provides guidelines on the use of both stationary and portable,
for example hand-held, instruments to monitor for radiation signatures from radioactive material.
Emphasis is placed on the operational aspects, i.e., requirements derived for monitoring of traffic
and commodities mainly at border-crossing facilities. Although the term border is used repeatedly
in this document, it is meant to apply not only to international land borders but also maritime ports,
airports, and similar locations where goods or individuals are being checked. This document does not
specifically address the issue of detection of radioactive materials at recycling facilities, although it is
recognized that transboundary movement of metals for recycling occurs, and that monitoring of scrap
metals might be done at the borders of a state.
This document is applicable to
— regulatory bodies and other competent authorities seeking guidance on implementation of action
plans to combat illicit trafficking,
— law enforcement agencies, for example border guards, to obtain guidelines on recommended
monitoring procedures,
— equipment manufacturers in order to understand minimum requirements derived from operational
necessities according to this document, and
— end-users of radiation detection equipment applicable to this document.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60325, Radiation protection instrumentation — Alpha, beta and alpha/beta (beta energy > 60keV)
contamination meters and monitors
IEC 61526, Radiation protection instrumentation — Measurement of personal dose equivalents H (10) and
p
H (0,07) for X, gamma, neutron and beta radiations – Direct reading personal dose equivalent meters
p
IEC 62244, Radiation protection instrumentation — Installed radiation portal monitors (RPMs) for the
detection of illicit trafficking of radioactive and nuclear materials
IEC 62327, Radiation protection instrumentation — Hand-held instruments for the detection and
identification of radionuclides and for the estimation of ambient dose equivalent rate from photon radiation
IEC 62387, Radiation protection instrumentation — Dosimetry systems with integrating passive detectors
for individual, workplace and environmental monitoring of photon and beta radiation
IEC 62401, Radiation protection instrumentation — Alarming personal radiation devices (PRDs) for the
detection of illicit trafficking of radioactive material
IEC 62484, Radiation protection instrumentation — Spectrometric radiation portal monitors (SRPMs)
used for the detection and identification of illicit trafficking of radioactive material
IEC 62533, Radiation protection instrumentation — Highly sensitive hand-held instruments for photon
detection of radioactive material
IEC 62534, Radiation protection instrumentation — Highly sensitive hand-held instruments for neutron
detection of radioactive material
IEC 62618, Radiation protection instrumentation — Spectroscopy-based alarming Personal Radiation
Detectors (SPRD) for the detection of illicit trafficking of radioactive material
IEC 62694, Radiation protection instrumentation — Backpack-type radiation detector (BRD) for the
detection of illicit trafficking of radioactive material
IEC 62945, Radiation protection instrumentation — Measuring the imaging performance of X-ray
computed tomography (CT) security screening systems
IEC 62963, Radiation protection instrumentation — X-ray computed tomography (CT) inspection systems
of bottled/canned liquids
IEC 63085, Radiation protection instrumentation — System of spectral identification of liquids in
transparent and semitransparent container (Raman systems)
IEC 63121, Radiation protection instrumentation — Vehicle-mounted mobile systems for the detection of
illicit trafficking of radioactive materials
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
3.1
check source
radioactive source, not necessarily calibrated, used to confirm the continuing satisfactory operation of
an instrument designed to detect photonic or particulate radiation
3.2
competent authority
any body or authority designated or otherwise recognized as such for any purpose in connection with
the transport regulations
[SOURCE: IAEA Nuclear Safety and Security Glossary: 2022(interim) edition. Vienna: IAEA, 2022. 248 p]
Note 1 to entry: This term is used only with reference to the Transport Regulations for consistency with
terminology used in the wider field of regulation of the transport of dangerous goods. Otherwise, the more
general term regulatory body should be used, with which competent authority is essentially synonymous.
3.3
computer security
particular aspect of information security that is concerned with the protection of computer-based
systems against compromise
[SOURCE: IAEA Nuclear Safety and Security Glossary: 2022(interim) edition. Vienna: IAEA, 2022. 248 p]
3.4
detection
discovery of the presence of radioactive material on the basis of measurements and interpretation of
results
3.5
detection limit
smallest true value of the measurand which ensures a specified probability of being detectable by the
measurement procedure
[SOURCE: ISO 12749-1: 2020, 3.4.11]
3.6
false-alarm rate
rate of alarms which are not caused by a radioactive source under the specified background conditions
3.7
illicit trafficking
any intentional unauthorized movement of radioactive materials, particularly across national borders,
for subsequent illegal sale, use, storage or further transfer
3.8
inadvertent movement
any unintentional unauthorized receipt, possession, use or transfer of radioactive materials
3.9
nuclear material
238 233
plutonium except that with isotopic concentration exceeding 80 % in Pu; U; uranium enriched in
the isotope 235 or 233; uranium containing the mixture of isotopes as occurring in nature other than in
the form of ore or ore residue; any material containing one or more of the foregoing
[SOURCE: IAEA Nuclear Safety and Security Glossary: 2022(interim) edition. Vienna: IAEA, 2022. 248 p]
3.10
radioactive contamination
radioactive substances on surfaces, or within solids, liquids or gases (including the human body), where
their presence is unintended or undesirable, or the process giving rise to their presence in such places
[SOURCE: ISO 12749-1: 2020, 3.3.4]
3.11
radioactive material
material designated in national law or by a regulatory body as being subject to regulatory control
because of its radioactivity
[SOURCE: IAEA Nuclear Safety and Security Glossary: 2022(interim) edition. Vienna: IAEA, 2022. 248 p]
Note 1 to entry: This is the “regulatory” meaning of radioactive, and should not be confused with the “scientific”
meaning of radioactive.
Note 2 to entry: The term radioactive substance is also used to indicate that the “scientific” meaning of radioactive
is intended, rather than the “regulatory” meaning of radioactive suggested by the term radioactive material.
3.12
radiological monitoring
radiation monitoring
measurement of dose, dose rate or activity for reasons relating to the assessment or control of exposure
to radiation or exposure due to radioactive substances, and the interpretation of the results
[SOURCE: ISO 12749-1: 2020, 3.3.5]
Note 1 to entry: The general term “dose” refers to ambient dose equivalent if not stated otherwise in this
document.
3.13
radionuclide
nuclide which is in an unstable state due to excess of internal energy and which will attain a stable state
by emitting radiation
40 235 238 232
Note 1 to entry: Radionuclides are either naturally occurring radionuclides, such as K, U, U, Th and
their radioactive decay products or produced by activation or other artificial means.
[SOURCE: ISO 12749-1: 2020, 3.1.8]
3.14
regulatory body
authority or system of authorities designated by the government of a State as having legal authority for
conducting the regulatory process, including issuing authorizations, and thereby regulating nuclear,
radiation, radioactive waste and transport safety
[SOURCE: IAEA Nuclear Safety and Security Glossary: 2022(interim) edition. Vienna: IAEA, 2022. 248 p]
3.15
threat
person or group of persons with motivation, intention and capability to commit a malicious act
[SOURCE: IAEA Nuclear Safety and Security Glossary: 2022(interim) edition. Vienna: IAEA, 2022. 248 p]
3.16
threat assessment
evaluation of the threat (3.15), based on available intelligence, law enforcement, and open source
information, that describes the motivation, intentions, and capabilities of these threats
[SOURCE: IAEA Nuclear Safety and Security Glossary: 2022(interim) edition. Vienna: IAEA, 2022. 248 p]
3.17
threshold level
level of some measurable (or otherwise assessable) quantity such that, if that level is exceeded,
something happens.
[SOURCE: IAEA Nuclear Security glossary: 2020 edition, draft. Vienna: IAEA, 2020. 60 p]
Note 1 to entry: The threshold level for a detection instrument is a level of the measured quantity (for example, of
dose rate) that, if exceeded, triggers the instrument to generate an alarm. Such a threshold level is set by the user
of the instrument at the lowest level that might indicate some form of malicious act.
4 Monitoring
4.1 Overview
The process for detection of inadvertent movement or illicit trafficking of radioactive material
is illustrated by the flowchart in Figure 1. This provides an outline for the various clauses of this
document. It has the following main steps:
a) strategic evaluation of the need for border monitoring;
b) selection of instruments;
c) determination of threshold levels;
d) evaluation of alarms, by verification and localization of the radioactive material;
e) evaluation of radioactive material found.
This document primarily covers radiological monitoring at borders from a technical and operational
viewpoint. The decisions regarding whether, when, or where to establish radiological monitoring at
borders should result in a comprehensive national regulatory strategy for radioactive materials control.
One of the key factors in the development of a national strategy is threat assessment. By evaluating
historical, political, sociological, economic and geographic factors, a State can come to a reasonable
assessment as to the potential, or threat of illicit trafficking or inadvertent movement of radioactive
materials across its borders. For some countries, at certain border locations, monitoring may be
regarded as a necessary component of their overall strategy. For many others, the potential problem
is so low that it would not be considered sufficiently cost-beneficial to implement border monitoring.
However, it is recognized that sometimes radiological monitoring at borders is put in place more for
political, or public peace-of-mind reasons rather than a rational need based on a significant threat.
Should it be determined that border monitoring is needed, the results of the strategic analysis also
helps in the determination of the types of instruments to be used and where they should be deployed.
The monitoring process is most effective if it is conducted at locations that have the greatest potential
for identifying and intercepting illicit trafficking or inadvertent movement of radioactive material. In
general terms, these are “control points” or “nodal points” where the flow of people, vehicle movement
or freight converges. These locations may already be control points for other purposes, such as weigh-
stations or customs.
Figure 1 — Flowchart for detection of inadvertent movement or illicit trafficking of radioactive
material
4.2 Training requirements for border agents, inspectors and first responders
It is recommended that the agencies in charge of performing the monitoring for inadvertent movement
or illicit trafficking of radioactive material develop an operating procedure or tactical response plan
that describes the roles and responsibilities of the personnel involved in these activities. In addition, a
description of the type of response that the personnel follow based on the instruments’ measurement
results may also be part of the operating procedure. Training may be required to ensure that the
operating procedures are followed and that the users of instruments understand the functionality and
limitations of the instrumentation.
The monitoring and detection of inadvertent movement or illicit trafficking of radioactive materials
requires specialized training and basic technical knowledge. In the event that front-line officers are
unable to conduct an initial radiological hazard assessment, or recognize that they require assistance,
they should inform their duty supervisor. This individual should contact a pre-designated radiological
advisor. Suggested duties of the radiological advisor are listed in Reference [4] Annex III, and should
be contained in the State’s tactical response plan. This individual should automatically be deployed to
the scene if inadvertent movement or illicit trafficking of radioactive material incident is encountered.
However, it is appropriate to seek advice from the radiological advisor on the management of routine
incidents when there is any doubt or ambiguity in making the initial hazard assessment.
To minimize the potential for harmful radiation exposure and/or a serious incident, border agents,
inspectors and first responders tasked with the monitoring and detection of radioactive materials
should, as a minimum, have basic requisite training consisting of but not limited to
a) basic concepts on physics and types of radiation,
b) radioactivity and radiation hazards,
c) general awareness/familiarization as per Reference [1] subclause 313(a),
d) radiation protection and safety as per Reference [1] subclause 313(c),
e) radiation monitoring processes, detection and measurement skills, including theory of operation
for instruments on hand, routine checking (testing), maintenance, etc.,
f) risk and situation assessment, and
g) response to a radiation alarm.
Training shall be provided by an accredited individual; and shall be updated as required over the period
of employment. Personnel should receive a certificate, or record of training, upon successful completion.
Records of training shall be retained by the employer for the duration of the trainee’s employment, or
as required by regulatory authorities.
4.3 Monitoring instruments
4.3.1 General
There are different types of instruments that can be used for monitoring and detection of inadvertent
movement and illicit trafficking of radioactive material, these include
a) personal radiation devices,
b) hand-held instruments,
c) hand-held radionuclide identification devices (RIDs),
d) installed radiation portal monitors with or without spectrometry capabilities (SRPMs or RPMs) ,
e) backpack-type radiation detectors (BRDs),
f) mobile systems,
g) active interrogation, and
h) imaging systems.
As for most radiation detectors, manufacturers’ recommendations should be followed. The general
climatic, electromagnetic and mechanical performance requirements and methods of tests
requirements can address from Reference [8]. The data format used in the detection of illicit trafficking
of radioactive material should refer to Reference [9]. The guidance and recommendations for radiation
sources used in illicit trafficking detection are described in Reference [10].
Generally, the instrument is not used for routine measurements, and while some instrument
manufacturers provide recommendations for periodic calibrations, general guidance on appropriate
performance maintenance is lacking. Annual laboratory calibration intervals may not be practical or
appropriate for monitoring and detection of inadvertent movement and illicit trafficking of radioactive
material that are not covered by regulations. It is typically recommended that instrument calibration
be carried out annually by a qualified individual or maintenance facility. The period of calibration can
be adjusted based on the instrument performance and the user capabilities. (See Reference [11] [12]
[13] [14] [15] [16]).
The general characteristics, applications, requirements, and operation for each type of instruments are
listed in the subclauses below.
4.3.2 Personal radiation devices
4.3.2.1 General characteristics
These devices are small, lightweight devices used to detect the presence of radioactive material and to
inform the user about radiation levels. These devices, roughly the size of a mobile phone, which can be
worn on a belt or carried in a pocket for hands-free operation and alert the operator to the presence of
radioactive materials. Because of their small size, these devices are ideally suited for use by individual
law or border enforcement officers and first responders, for example front-line officer, fire fighters,
without requiring extensive training. Some of these devices can also provide radionuclide identification
capabilities.
There are different types of personal radiation devices. Even if similar in appearance these devices are
required to meet different types of requirements. These may include
a) personal radiation detectors (PRDs),
b) spectroscopy-based personal radiation detectors (SPRDs),
c) electronic personal dosimeters (EPDs),
d) extended range personal radiation detectors (ER-PRDs), and
e) personal emergency radiation detectors (PERDs).
A PRD is a small, lightweight, robust device, which alerts the wearer to radiation levels above
background from gamma-ray and X-ray radiation, and in some cases for neutrons. The SPRDs have the
same capabilities as the PRDs, but in addition have radionuclide identification capabilities. EPDs are
designed to be worn on workers in planned radiation exposure situations to measure the individual
dose. The ER-PRDs are dual detector instruments that extend the measurement range of a PRD without
losing the low dose rate sensitivity. PERDs are designed to measure the individual dose. These devices
can display radiation dose and dose rate. Its alarm function can work if the dose or dose rate exceeds a
pre-set threshold and can be used as a tool for responder dose monitoring.
4.3.2.2 Operation
PRDs, ER-PRDs and SPRDs are commonly used for monitoring for inadvertent movement and illicit
trafficking of radioactive materials. PRDs should be worn on the body, ideally the torso, in a pocket, on
a lanyard or belt or similar secured method. A self-testing feature should verify proper operation of the
instrument (including battery charge level) before usage. False alarms, i.e. alarms without radioactive
materials present, occur occasionally due to the fluctuations in background. When the alarm-threshold
is set properly, false alarms should occur not more than once per day. There is always a trade-off between
detection sensitivity and false alarms. Radiation triggering innocent alarms may be detected on an
occasional basis. This is due to the fact that many objects including, for example foodstuffs, dinnerware,
tiles, concrete, fertilizer, ice melt, sand, cat litter, etc., contain small quantities of radioactive material
such as potassium, radium, thorium or uranium. Also, persons who have undergone radiation therapy
or diagnosis may be sources of radiation. In some cases when the treatment or test was recently carried
out, the levels of radiation can be high.
4.3.2.3 Calibration and routine checking
Most personal radiation devices go through a self-checking routine when turned on. For its continued
ability to detect radiation, a personal radiation device should be checked on a daily basis or prior to
use, if possible. Functionality tests may be performed on these devices to assure proper response.
This may be done by placing the instrument near a low activity radioactive check source or naturally
occurring radioactive materials (NORM) (see Annex C) and observing its response to the radiation.
Manufacturers’ recommendations should be followed. Appropriate check sources (see Reference [14]),
with sufficient output to produce a significant reading on the instruments used, are very useful.
Like most radiation detectors, it is recommended that EPDs be regularly calibrated (as required by the
national regulatory authority).
4.3.2.4 Minimum performance requirements and test methods
PRDs shall meet the performance requirements described in IEC 62401, SPRDs in IEC 62618 and EPDs
in IEC 61526 and IEC 62387. These documents also describe the associated test methods.
4.3.3 Hand-held instruments
4.3.3.1 General characteristics
Hand-held instruments provide greater sensitivity of detection compared to PRDs, but they are heavier
and usually more expensive. For example, they would be chosen
a) when a suspicion of illicit trafficking already exists based on intelligence reports,
b) to localize a source,
c) to measure the dose rate, and
d) to identify the radionuclide.
Hand-held instruments are small, battery-powered radiation detection instruments that measure
the ambient background level and then calculate an alarm-threshold based on a sigma level above
background. Thus, these instruments can compensate for variations in the background level when
turned on, or on command. These instruments continuously make short time measurements of
the radiation level and compare the results to the alarm-threshold. The hand-held instruments
can effectively search pedestrians, packages, cargo, and motor vehicles at a close distance. These
instruments can alert the user to unexpected levels of radiation present in the background.
The most significant difference between the hand-held instruments and installed portal monitors is
the human factor that strongly influences the ability of a hand-held instrument to detect radioactive
materials in the field when placed at a close distance and moved at a slow speed. If the officer does not
move the instrument at a slow enough speed and in close enough proximity to any radioactive material
that is present, it may not be detected.
The hand-held instruments can be placed nearer to the radioactive material where the dose rate is
higher, thus yielding higher sensitivity to the radiation signature. To achieve that sensitivity, border
agents, inspectors and first responders shall be trained in the proper technique to conduct effective
searches, and the training should be repeated periodically.
Hand-held instruments are designed to measure one or more of photon, alpha, beta or neutron
radiations. For interdiction and detection activities, the most common type is the hand-held instruments
with gamma detection capabilities, and in some cases with neutron detection. Hand-held instruments
with alpha and beta detectors are mostly used for detection of radioactive contamination. These may
be used by agencies to clear people or packages that are potentially contaminated with radioactive
materials.
4.3.3.2 Operation
Hand-held instruments can be used either as the primary search instruments or as second-stage search
instruments for installed radiation portal monitors. This type of instruments is used to facilitate the
localisation of radiation sources by providing an alarm and/or a frequency dependent alarm indication
on dose rate or count rate.
4.3.3.3 Calibration and routine testing
A hand-held instrument should be source checked daily or prior to use, if possible, for its continued
ability to detect radiation. This may be done by placement of the instrument near a radiation check
source and observing a repeatable radiation level.
Like most radiation detectors that provide dose rate measurements, it is recommended that these
instruments be calibrated periodically (as required by the national regulatory authority).
4.3.3.4 Minimum performance requirements and test methods
Hand-held instruments shall meet the performance requirements of one of the following standards:
— contamination meters covered by IEC 60325;
— highly sensitive gamma detectors covered by IEC 62533;
— highly sensitive neutron detectors covered by IEC 62534.
These documents also describe the associated test methods.
4.3.4 Hand-held radionuclide identification devices (RIDs)
4.3.4.1 General characteristics
RIDs are hand-held, battery-powered devices used for in field radionuclide identification of radioactive
materials by non-experts. These instruments provide self-calibration and gain stabilization based on
137 40
an internal or external source (e.g. Cs, K).
Most of the radionuclides encountered at borders can be identified by instruments capable of identifying
gamma-ray energy peaks between 60 keV and at least 1,5 MeV (in most cases a maximum range
232 232
of 3 MeV is recommended for the identification of U or Th). These devices use scintillator or solid-
state detectors (such as sodium iodine (NaI(Tl)), high purity germanium (HPGe), etc.) to discriminate
different gamma-ray energies emitted by radioactive nuclides (i.e. radionuclides).
These devices can provide a radiation exposure or dose rate display, as they are equipped with several
detectors that may include a Geiger-Muller (GM) tube. Some of these devices are also equipped with a
neutron detector.
A library of common radionuclides (and in some cases the number of gamma-ray lines for a given
radionuclide) stored within the RID’s CPU allows the devices to identify the radionuclides found with
a high level confidence. Compilation, editing, optimizing and testing of the radionuclide libraries used
are essential and should be carefully programmed by the developer or an expert user. The radionuclide
library should be tailored to the radionuclides commonly encountered at a given location. These
devices provide a message when radiation is detected, the radionuclide is not in the library, or when the
counting statistics are poor.
For the purpose of this document, the term radioactive materials may be used in reference to nuclear
materials, industrial radionuclides, medical radionuclides and NORMs, for example
233 235 238 239 241
a) Nuclear materials: U, U, U, Pu, Pu,
57 60 75 90 133 137 152 192 203 226 241 238
b) Industrial radionuclides: Co, Co, Se, Sr, Ba, Cs, Eu, Ir, Hg, Ra, Am, Pu,
Cf,
18 22 51 67 99 99m 103 201 123 125 131 133 111
c) Medical radionuclides:
...
NORME ISO
INTERNATIONALE 22188
Deuxième édition
2023-08
Surveillance des mouvements non
déclarés et des trafics illicites de
matière radioactive
Monitoring for inadvertent movement and illicit trafficking of
radioactive material
Numéro de référence
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2023
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii
Sommaire Page
Avant propos .iv
Introduction . vi
1 Domaine d’application . 1
2 Références normatives .1
3 Termes et définitions . 2
4 Surveillance . . 5
4.1 Vue d’ensemble . 5
4.2 Exigences de formation pour les agents frontaliers, les inspecteurs et les premiers
intervenants . 7
4.3 Instruments de surveillance . 7
4.3.1 Généralités . 7
4.3.2 Instruments individuels de détection du rayonnement . 8
4.3.3 Instruments portables . 9
4.3.4 Dispositifs portables d’identification des radionucléides (RID) . 11
4.3.5 Portiques de détection des rayonnements installés .12
4.3.6 Systèmes mobiles . 14
4.3.7 Détecteurs de rayonnement de type sac à dos .15
4.3.8 Systèmes d’imagerie et d’interrogation actives . 15
5 Surveillance des rayonnements aux postes de contrôle .16
5.1 Généralités . 16
5.2 Considérations importantes . 16
5.3 Vérification . . 17
5.4 Localisation . 17
5.5 Identification . 17
5.6 Techniques de recherche, intervention opérationnelle et suivi . 17
6 Cyberassurance pour les instruments de surveillance .17
6.1 Généralités . 17
6.2 Bonnes pratiques fondées sur les risques . 18
6.3 Aspects opérationnels . 18
Annexe A (informative) Alarmes et niveaux seuils.20
Annexe B (informative) Dispositifs et radionucléides pouvant faire l’objet d’un trafic .24
Annexe C (informative) Exemples de matières radioactives naturelles .25
Bibliographie .26
iii
Avant propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier, de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document
a été rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2
(voir www.iso.org/directives).
L’ISO attire l’attention sur le fait que la mise en application du présent document peut entraîner
l’utilisation d’un ou de plusieurs brevets. L’ISO ne prend pas position quant à la preuve, à la validité et
à l’applicabilité de tout droit de propriété revendiqué à cet égard. À la date de publication du présent
document, l’ISO n’avait pas reçu notification qu’un ou plusieurs brevets pouvaient être nécessaires à sa
mise en application. Toutefois, il y a lieu d’avertir les responsables de la mise en application du présent
document que des informations plus récentes sont susceptibles de figurer dans la base de données de
brevets, disponible à l’adresse www.iso.org/brevets. L’ISO ne saurait être tenue pour responsable de ne
pas avoir identifié de tels droits de brevets.
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion
de l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles
techniques au commerce (OTC), voir www.iso.org/avant-propos.
Le présent document a été élaboré par le comité technique ISO/TC 85, Énergie nucléaire, technologies
nucléaires, et radioprotection, sous-comité SC 2, Radioprotection.
Cette deuxième édition annule et remplace la première édition (ISO 22188:2004), qui a fait l’objet d’une
révision technique.
Les principales modifications sont les suivantes:
— mise à jour de l’introduction, compte tenu de l’évolution constante de la technologie;
— mise à jour de l’Article 2;
— la première édition contenait 14 termes et définitions (ISO 22188:2004). Conformément aux normes
applicables et aux documents techniques de l’AIEA,
— les termes suivants ont été supprimés: 3.1 maîtrise des matières radioactives, 3.9 non-
prolifération, 3.10 protection physique, 3.12 réponse, 3.13 garanties et 3.14 matières nucléaires
spéciales;
— les termes suivants ont été ajoutés: 3.1 source de vérification, 3.2 autorité compétente,
3.3 sécurité informatique, 3.9 matière nucléaire, 3.10 contamination radioactive, 3.11 matière
radioactive, 3.12 surveillance radiologique, 3.13 radionucléide, 3.15 menace, 3.16 évaluation de
la menace et 3.17 niveau seuil. Le nombre de termes et de définitions est désormais de 17;
— conformément au titre de la norme, le terme «instruments» figurant dans le titre de l’Article 4 a été
supprimé. À l’origine, la première édition (ISO 22188:2004) répertoriait quatre types d’instruments:
iv
les instruments de poche, les instruments portables, les instruments installés et les identificateurs
de radionucléides. Dans cette deuxième édition, le nombre de types d’instruments est passé à 7.
Il s’agit notamment des instruments individuels de détection du rayonnement, des instruments
portables, des dispositifs portables d’identification des radionucléides, des portiques de détection
des rayonnements installés, des détecteurs de rayonnement de type sac à dos, des systèmes mobiles
et des systèmes d’imagerie et d’interrogation actifs. Pour chaque instrument, les caractéristiques
générales, son fonctionnement, son étalonnage et son essai de bon fonctionnement en routine, ses
exigences minimales de performance et ses méthodes d’essai sont présentées. Les références aux
normes IEC couvrant les exigences de performance pour ces types d’instruments ont été ajoutées et
les exigences énumérées dans le présent document ont été supprimées;
— le présent document s’intéresse essentiellement à la surveillance radiologique des frontières d’un
point de vue technique et opérationnel. Il convient que les décisions d’établir ou non une surveillance
radiologique des frontières et le choix du moment ou des lieux où établir cette surveillance résultent
d’une stratégie réglementaire nationale globale visant la maîtrise des matières radioactives. Par
conséquent, les exigences en matière de formation pour les agents frontaliers, les inspecteurs et les
premiers intervenants ont été ajoutées (voir 4.2);
— les systèmes de surveillance des rayonnements, en particulier ceux qui sont en réseau, connectés à
Internet ou qui utilisent des services sur le cloud, sont vulnérables à toute une série de cybermenaces.
La sécurité informatique de ces systèmes vise à maintenir l’intégrité, l’accessibilité, l’authenticité et,
le cas échéant, la confidentialité des données et du contrôle des instruments. Il convient que les
utilisateurs finaux demandent conseil aux autorités nationales en matière de sécurité informatique
pour assurer la continuité des activités et la fiabilité des services et systèmes de surveillance des
rayonnements. Un nouvel Article 6 a été ajouté pour traiter cette question;
— certaines parties de l’Annexe A et la totalité des Annexes B et C ont été intégrées dans le texte des
Articles 4 et 5 du document révisé. L’Annexe D a été supprimée et des références aux normes IEC
applicables ont été données pour les exigences de performance et les méthodes d’essai. L’Annexe A
a été réécrite et simplifiée sous le titre Alarmes et niveaux de seuil. Une nouvelle Annexe B a été
ajoutée pour dresser la liste des dispositifs et radionucléides susceptibles de faire l’objet d’un trafic.
Des exemples de matières radioactives naturelles figurent à l’Annexe C;
— mise à jour de la Bibliographie.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes
se trouve à l’adresse www.iso.org/fr/members.html.
v
Introduction
Le système de base de données sur les incidents et les cas de trafic (ITDB) de l’Agence internationale
de l’énergie atomique (AIEA) enregistre depuis 1995 les incidents liés aux mouvements non déclarés
et aux trafics illicites de matières nucléaires et autres matières radioactives. Bien que le nombre
d’incidents signalés fluctue dans le temps, ceux liés aux trafics ou à des utilisations malveillantes
restent préoccupants. Un petit nombre de ces incidents signalés concerne des saisies de matières
nucléaires potentiellement utilisables en tant qu’armes, mais la majorité concerne des activités non
autorisées, notamment le vol ou la disparition de matières radioactives et la détection de marchandises
manufacturées contaminées. Parmi ces exemples, il est possible de citer l’incorporation involontaire de
matières radioactives dans de l’acier recyclé, la manipulation de sources radioactives perdues par des
personnes non averties et le vol délibéré de matières radioactives.
Le risque radiologique potentiel pour les travailleurs, le public en général et l’environnement, engendré
par des matières radioactives détournées, ajoute une menace supplémentaire aux mouvements non
déclarés et aux trafics illicites. Il s’est trouvé des cas où la perte de maîtrise des matières radioactives a
conduit à des conséquences graves, voire mortelles. La détection de matières radioactives aux passages
de frontières, comme dans les ports maritimes, les aéroports et à l’intérieur des différents pays,
par exemple aux postes de contrôle, est donc une question importante.
Le présent document traite des aspects procéduraux de la détection de matières radioactives.
Ces aspects comportent les techniques de recherche, de localisation et éventuellement d’identification
des substances radioactives. Des lignes directrices de création de programmes de formation appropriés
et de maintenance des équipements sont également considérées comme un aspect pertinent de l’étude.
Les instruments utilisés dans le processus sont définis par des exigences minimales pour rendre
applicables les modes opératoires recommandés. Il s’agit notamment des instruments individuels
de détection du rayonnement, des instruments portables, des dispositifs portables d’identification
des radionucléides, des portiques de détection des rayonnements installés, des détecteurs de
rayonnement de type sac à dos, des systèmes mobiles et des systèmes d’imagerie et d’interrogation
actives. Les spécifications relatives aux exigences minimales de performance et aux méthodes d’essai
pour l’instrumentation sont couvertes par d’autres normes existantes, qui sont énumérées dans le
paragraphe de références normatives.
En raison des progrès constants réalisés dans le domaine des équipements de surveillance des radiations
aux frontières, on présume qu’elles peuvent représenter un consensus sur les spécifications minimales
réalisables à l’heure actuelle. Le présent document devrait permettre une utilisation et une exploitation
plus efficaces de l’équipement existant, faciliter la communication transfrontalière et encourager les
activités visant à détecter les mouvements non déclarés et les trafics illicites de matières radioactives
et à y riposter. Les avantages qui en seront tirés contribueront aux efforts déployés pour contrer la
prolifération des armes nucléaires et accroître la protection contre les rayonnements. Un manque de
normalisation peut retarder la mise en œuvre des activités prévues, notamment si certains paramètres,
comme le niveau seuil, ne font pas l’objet d’un accord international. Les documents techniques publiés
par l’AIEA dans ce domaine fournissent un ensemble de spécifications techniques qui peuvent être
utilisées pour les essais de conception, la qualification et l’achat d’équipements de surveillance des
radiations aux frontières. Ils constituent une base de recommandation pour des spécifications et des
procédures justifiables et convenues, voir les Références [1], [2], [3], [4], [5], [6] et [7].
vi
NORME INTERNATIONALE ISO 22188:2023(F)
Surveillance des mouvements non déclarés et des trafics
illicites de matière radioactive
1 Domaine d’application
Le présent document spécifie des méthodes et moyens de surveillance des mouvements non déclarés
et des trafics illicites de matière radioactive. Il fournit des lignes directrices d’utilisation d’instruments
fixes et mobiles, par exemple des instruments portables, qui permettent de rechercher les signatures
de rayonnement de matières radioactives. Il insiste particulièrement sur les aspects opérationnels,
c’est-à-dire les exigences établies pour la surveillance de la circulation et des marchandises, surtout
au niveau des passages de frontières. Bien que le terme frontière soit fréquemment utilisé dans le
présent document, il convient d’indiquer qu’il désigne ici non seulement les frontières terrestres
internationales, mais également les ports maritimes, les aéroports et endroits similaires où l’on contrôle
des marchandises ou des personnes. Le présent document ne traite pas spécifiquement la question de la
détection des matières radioactives au niveau des installations de recyclage bien qu’il soit reconnu que
des mouvements transfrontaliers de métaux à recycler interviennent et que la surveillance de métaux
de rebut puisse se faire aux frontières d’un État.
Le présent document s’applique:
— aux organismes de réglementation et aux autres autorités compétentes qui souhaitent obtenir des
recommandations sur la mise en œuvre des plans d’action de lutte contre le trafic illicite;
— les organismes chargés de l’application de la loi, par exemple les gardes-frontières, afin d’obtenir des
lignes directrices sur les procédures de contrôle recommandées;
— aux fabricants d’équipements afin de comprendre les exigences minimales découlant des nécessités
opérationnelles conformément au présent document;
— aux utilisateurs finaux d’équipements de détection de rayonnements applicables au présent
document.
2 Références normatives
Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie de leur
contenu, des exigences du présent document. Pour les références datées, seule l’édition citée s’applique.
Pour les références non datées, la dernière édition du document de référence s’applique (y compris les
éventuels amendements).
IEC 60325, Instrumentation pour la radioprotection — Contaminamètres et moniteurs de contamination
alpha, bêta et alpha/bêta (énergie des bêta > 60 keV)
IEC 61526, Instrumentation pour la radioprotection — Mesure des équivalents de dose individuels H (10)
p
et H (0,07) pour les rayonnements X, gamma, neutron et bêta — Appareils de mesure à lecture directe de
p
l’équivalent de dose individuel
IEC 62244, Instrumentation pour la radioprotection — Portiques de détection des rayonnements (RPM)
installés pour la détection du trafic illicite de matières radioactives et nucléaires
IEC 62327, Instrumentation pour la radioprotection — Instruments portables pour la détection et
l’identification des radionucléides et pour l’estimation du débit d’équivalent de dose ambiant pour le
rayonnement de photons
IEC 62387, Instrumentation pour la radioprotection — Systèmes dosimétriques avec détecteurs intégrés
passifs pour le contrôle radiologique individuel, du lieu de travail et de l’environnement des rayonnements
photoniques et bêta
IEC 62401, Instrumentation pour la radioprotection — Dispositifs individuels d’alarme aux rayonnements
pour la détection du trafic illicite des matières radioactives
IEC 62484, Instrumentation pour la radioprotection — Portiques spectrométriques de détection des
rayonnements (SRPMs) utilisés pour la détection et l’identification du trafic illicite des matières radioactives
IEC 62533, Instrumentation pour la radioprotection — Instruments portables de haute sensibilité pour la
détermination photonique de matières radioactives
IEC 62534, Instrumentation pour la radioprotection — Instruments portables de haute sensibilité pour la
détection neutronique de matières radioactives
IEC 62618, Instrumentation pour la radioprotection — Détecteurs individuels spectroscopiques d’alarme
aux rayonnements (SPRD) pour la détection du trafic illicite des matières radioactives
IEC 62694, Instrumentation pour la radioprotection — Détecteur de rayonnement de type sac-à-dos (BRD)
pour la détection du trafic illicite des matières radioactives
IEC 62945, Instrumentation pour la radioprotection — Mesure des performances d’imagerie des systèmes
de contrôle de sécurité utilisant la tomographie par ordinateur (CT) à rayons X
IEC 62963, Instrumentation pour la radioprotection — Systèmes d’inspection par tomographie aux rayons
x par ordinateur (CT) des liquides en bouteille ou en canette
IEC 63085, Instrumentation pour la radioprotection — Système d’identification spectrale des liquides dans
des récipients transparents et semi-transparents (systèmes Raman)
IEC 63121, Instrumentation pour la radioprotection — Systèmes mobiles montés sur véhicules pour la
détection du trafic illicite des matières radioactives
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s’appliquent.
L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en
normalisation, consultables aux adresses suivantes:
— ISO Online browsing platform: disponible à l’adresse https:// www .iso .org/ obp
— IEC Electropedia: disponible à l’adresse https:// www .electropedia .org/
3.1
source de vérification
source radioactive, pas nécessairement étalonnée, qui est utilisée pour confirmer le bon fonctionnement
continu d’un instrument conçu pour détecter les rayonnements photoniques ou particulaires
3.2
autorité compétente
toute autorité ou tout organisme désigné ou autrement reconnu comme tel à toute fin visée par le
Règlement de transport
[SOURCE: IAEA Nuclear Safety and Security Glossary: édition 2022 (provisoire). Vienne: IAEA, 2022.
248 p]
Note 1 à l'article: Cette expression est utilisée uniquement dans le contexte du Règlement de transport par souci
de cohérence avec la terminologie utilisée dans le domaine plus large de la réglementation du transport de
marchandises dangereuses. Dans les autres cas, il convient d’utiliser l’expression «organisme de réglementation»,
qui est essentiellement synonyme d’autorité compétente.
3.3
sécurité informatique
aspect particulier de la sécurité de l’information qui porte sur la protection des systèmes informatiques
contre les atteintes à l’intégrité
[SOURCE: IAEA Nuclear Safety and Security Glossary: édition 2022 (provisoire). Vienne: IAEA, 2022.
248 p]
3.4
détection
découverte de la présence de matière radioactive, fondée sur des mesures et sur l’interprétation de
résultats
3.5
limite de détection
plus petite valeur vraie du mesurande qui garantit une probabilité spécifiée d’être détecté par la
méthode de mesure
[SOURCE: ISO 12749-1:2020, 3.4.11]
3.6
taux de fausses alarmes
taux des alarmes qui ne sont pas provoquées par une source radioactive dans les conditions de bruit de
fond spécifiées
3.7
trafic illicite
tout mouvement intentionnel non autorisé de matières radioactives, en particulier au passage de
frontières nationales, dans le but de les vendre, de les utiliser, de poursuivre leur transfert ou de les
stocker illégalement
3.8
mouvement non déclaré
tout cas de réception, de possession, d’utilisation ou de transfert non autorisé et non intentionnel de
matières radioactives
3.9
matière nucléaire
238 233
plutonium à l’exception du plutonium dont la concentration isotopique en Pu dépasse 80 %, U,
235 233
uranium enrichi en U ou U, uranium contenant le mélange d’isotopes qui se trouve dans la
nature autrement que sous forme de minerai ou de résidu de minerai, et toute matière contenant un ou
plusieurs des éléments ou isotopes ci-dessus
[SOURCE: IAEA Nuclear Safety and Security Glossary: édition 2022 (provisoire). Vienne: IAEA, 2022.
248 p]
3.10
contamination radioactive
substances radioactives présentes sur les surfaces, dans les solides, dans les liquides ou dans les gaz
(y compris le corps humain), dont la présence est indésirable ou inattendue, ou processus aboutissant à
une telle présence
[SOURCE: ISO 12749-1:2020, 3.3.4]
3.11
matière radioactive
matière désignée en droit interne ou par un organisme de réglementation comme devant faire l’objet
d’un contrôle réglementaire en raison de sa radioactivité
[SOURCE: IAEA Nuclear Safety and Security Glossary: édition 2022 (provisoire). Vienne: IAEA, 2022.
248 p]
Note 1 à l'article: Cette définition est basée sur le sens réglementaire du terme radioactif, qu’il convient de ne pas
confondre avec le sens scientifique.
Note 2 à l'article: L’expression «substance radioactive» est aussi utilisée pour indiquer que c’est la définition
scientifique de radioactif qui s’applique, et non la définition réglementaire suggérée par l’expression
«matière radioactive».
3.12
surveillance radiologique
surveillance des rayonnements
mesure de la dose, du débit de dose ou de l’activité pour des raisons associées à l’évaluation ou au
contrôle de l’exposition à des rayonnements ou à des substances radioactives, et interprétation des
résultats
[SOURCE: ISO 12749-1:2020, 3.3.5]
Note 1 à l'article: Le terme général «dose» désigne l’équivalent de dose ambiant, sauf indication contraire dans le
présent document.
3.13
radionucléide
nucléide qui se trouve dans un état instable en raison d’un excès d’énergie interne et qui atteindra un
état stable en émettant un rayonnement
40 235 238 232
Note 1 à l'article: Les radionucléides sont soit naturels, comme le K, le U, le U, le Th et leurs produits de
désintégration, soit produits par activation ou par d’autres moyens artificiels.
[SOURCE: ISO 12749-1:2020, 3.1.8]
3.14
organisme de réglementation
autorité ou réseau d’autorités que le gouvernement d’un État a investie(s) du pouvoir juridique de
diriger le processus de réglementation, y compris de délivrer les autorisations, et donc de réglementer
la sûreté nucléaire, la sûreté radiologique, la sûreté des déchets radioactifs et la sûreté du transport
[SOURCE: IAEA Nuclear Safety and Security Glossary: édition 2022 (provisoire). Vienne: IAEA, 2022.
248 p]
3.15
menace
personne ou groupe de personnes ayant la motivation, l’intention et la capacité de commettre un acte
malveillant
[SOURCE: IAEA Nuclear Safety and Security Glossary: édition 2022 (provisoire). Vienne: IAEA, 2022.
248 p]
3.16
évaluation de la menace
évaluation de la menace (3.15), basée sur les renseignements disponibles, l’application du droit et des
informations de source ouverte, qui décrit la motivation, les intentions et les capacités de ces menaces
[SOURCE: IAEA Nuclear Safety and Security Glossary: édition 2022 (provisoire). Vienne: IAEA, 2022.
248 p]
3.17
niveau seuil
niveau d’une quantité mesurable (ou évaluable d’une quelque autre manière) tel que, si ce niveau est
dépassé, un phénomène se produit
[SOURCE: IAEA Nuclear Security glossary: édition 2020, projet. Vienne: AIEA, 2020. 60 p]
Note 1 à l'article: Le niveau seuil d’un instrument de détection est un niveau de la quantité mesurée (par
exemple du débit de dose) qui, s’il est dépassé, déclenche une alarme sur l’instrument. Ce niveau seuil est fixé par
l’utilisateur de l’instrument au niveau le plus bas qui pourrait indiquer une forme d’acte malveillant.
4 Surveillance
4.1 Vue d’ensemble
Le processus de détection de mouvements non déclarés et de trafics illicites de matières radioactives
est illustré par l’organigramme à la Figure 1. Il donne un aperçu des différents paragraphes du présent
document. Ce processus comporte les étapes principales suivantes:
a) évaluation stratégique de la nécessité de surveiller les frontières;
b) choix des instruments;
c) détermination des niveaux seuils;
d) évaluation des alarmes par vérification et localisation de la matière radioactive;
e) évaluation des matières radioactives trouvées.
Le présent document s’intéresse essentiellement à la surveillance radiologique des frontières d’un
point de vue technique et opérationnel. Il convient que les décisions d’établir ou non une surveillance
radiologique des frontières et le choix du moment ou des lieux où cette surveillance doit être établie
résultent d’une stratégie réglementaire nationale globale visant la maîtrise des matières radioactives.
L’un des facteurs essentiels de l’élaboration d’une stratégie nationale est l’évaluation de la menace.
Après évaluation des facteurs historiques, politiques, sociologiques, économiques et géographiques,
un État peut parvenir à une évaluation correcte du risque ou de la menace de trafics illicites ou de
mouvements non déclarés de matières radioactives permettant à ces dernières de franchir ses
frontières. Pour certains pays, dans certaines régions frontalières, une surveillance de ce type peut
être considérée comme une composante nécessaire de leur stratégie globale. Pour de nombreux
autres pays, le problème potentiel est si faible que la mise en œuvre d’une surveillance des frontières
ne serait pas considérée comme suffisamment rentable. Il est cependant admis que, dans certains cas,
une surveillance radiologique des frontières est mise en place davantage pour des raisons politiques
ou des motifs de tranquillité d’esprit du public qu’en raison d’une nécessité rationnelle fondée sur une
menace significative.
S’il est déterminé qu’une surveillance des frontières est nécessaire, les résultats de l’analyse stratégique
aident également à déterminer les types d’instruments à utiliser et les endroits où il convient de les
déployer. Le processus de surveillance est optimal s’il est appliqué aux endroits où les chances sont les
plus grandes d’identifier et d’intercepter les trafics illicites ou les mouvements non déclarés de matières
radioactives. En termes généraux, ces endroits sont des «points de contrôle» ou «points nodaux»
où convergent les flux de personnes, de véhicules ou de marchandises. Ces endroits peuvent déjà
constituer des points de contrôle utilisés à d’autres fins tels que les postes de pesée ou les installations
douanières.
Figure 1 — Organigramme de détection de mouvements non déclarés ou de trafics illicites
de matières radioactives
4.2 Exigences de formation pour les agents frontaliers, les inspecteurs et les premiers
intervenants
Il est recommandé aux organismes chargés de la surveillance des mouvements non déclarés ou
des trafics illicites de matières radioactives d’élaborer une procédure d’exploitation ou un plan
d’intervention tactique décrivant les rôles et responsabilités du personnel impliqué dans ces activités.
En outre, une description du type d’intervention que le personnel doit suivre en fonction des résultats de
mesure des instruments peut également faire partie de la procédure d’exploitation. Une formation peut
être nécessaire pour s’assurer que les procédures d’exploitation sont respectées et que les utilisateurs
des instruments comprennent la fonctionnalité et les limites de l’instrumentation.
La surveillance et la détection des mouvements non déclarés ou des trafics illicites de matières
radioactives exigent une formation spécialisée et des connaissances techniques de base. Dans le
cas où les agents de terrain seraient dans l’impossibilité de mener une évaluation initiale du danger
radiologique ou s’ils reconnaissent avoir besoin d’assistance, il convient qu’ils en informent leur
responsable de permanence. Il convient alors que ce dernier prenne contact avec un conseiller en
mesures radiologiques désigné à l’avance. Les responsabilités envisageables pour le conseiller en
mesures radiologiques sont énumérées dans la Référence [4] de l’Annexe III et il convient qu’elles
figurent dans le plan d’intervention tactique de l’État. En cas d’incident lié à un mouvement non déclaré
ou un trafic illicite de matières radioactives, il convient que ce conseiller soit automatiquement envoyé
sur les lieux. Il est cependant recommandé de demander l’avis du conseiller en mesures radiologiques
concernant la gestion des incidents ordinaires en cas de doute quelconque ou d’ambiguïté dans la
conduite de l’évaluation initiale du danger.
Pour réduire le plus possible le risque d’exposition à des rayonnements nocifs et/ou d’incident grave,
il convient que les agents frontaliers, les inspecteurs et les premiers intervenants chargés de la
surveillance et de la détection des matières radioactives aient, au minimum, une formation de base
comprenant, entre autres, les domaines suivants:
a) notions de base sur la physique et les types de rayonnements;
b) dangers de la radioactivité et des rayonnements;
c) sensibilisation/familiarisation générale selon la Référence [1], paragraphe 313(a);
d) radioprotection et sûreté selon la Référence [1], paragraphe 313(c);
e) processus de surveillance des rayonnements, compétences en matière de détection et de mesure,
y compris la théorie du fonctionnement des instruments disponibles, les vérifications de routine
(essais), la maintenance, etc.;
f) évaluation des risques et des situations;
g) intervention en cas d’alarme de rayonnement.
La formation doit être dispensée par une personne accréditée et être actualisée si nécessaire au cours
de la période d’emploi. Il convient de fournir au personnel un certificat ou un dossier de formation
lorsqu’il l’a terminée avec succès. Les dossiers de formation doivent être conservés par l’employeur
pendant toute la durée de l’emploi du stagiaire, ou selon les exigences des autorités de régulation.
4.3 Instruments de surveillance
4.3.1 Généralités
Il existe différents types d’instruments qui peuvent être utilisés pour la surveillance et la détection des
mouvements non déclarés et des trafics illicites de matières radioactives:
a) instruments individuels de détection du rayonnement;
b) instruments portables;
c) les dispositifs portables d’identification des radionucléides (RID);
d) les portiques de détection des rayonnements installés, avec ou sans fonctionnalités de spectrométrie
(SRPM ou RPM);
e) les détecteurs de rayonnement de type sac à dos (BRD);
f) les systèmes mobiles;
g) l’interrogation active;
h) les systèmes d’imagerie.
Comme pour la plupart des détecteurs de rayonnements, il convient de suivre les recommandations
du fabricant. Les exigences générales en matière de performances climatiques, électromagnétiques
et mécaniques ainsi que les exigences relatives aux méthodes d’essai peuvent être abordées dans
la Référence [8]. Il convient que le format de données utilisé pour la détection du trafic illicite de
matières radioactives se réfère à la Référence [9]. Les documents d’orientation et les recommandations
relatives aux sources de rayonnement utilisées pour la détection du trafic illicite sont décrits dans la
Référence [10].
En règle générale, l’instrument n’est pas utilisé pour des mesures de routine, et bien que certains
fabricants fournissent des recommandations pour des étalonnages périodiques, il n’existe pas de
recommandations générales sur le maintien approprié des performances. Les intervalles annuels
d’étalonnage en laboratoire peuvent ne pas être pratiques ou appropriés pour la surveillance et la
détection des mouvements non déclarés et des trafics illicites de matières radioactives qui ne sont pas
couvertes par la réglementation. Il est généralement recommandé que l’étalonnage des instruments
soit effectué chaque année par une personne qualifiée ou une installation de maintenance. La période
d’étalonnage peut être ajustée en fonction des performances de l’instrument et des capacités de
l’utilisateur. (Voir Références [11], [12], [13], [14], [15], [16]).
Les caractéristiques générales, les applications, les exigences et le fonctionnement de chaque type
d’instrument sont énumérés dans les paragraphes ci-dessous.
4.3.2 Instruments individuels de détection du rayonnement
4.3.2.1 Caractéristiques générales
Ces dispositifs sont de petits dispositifs légers utilisés pour détecter la présence de matières radioactives
et pour informer l’utilisateur des niveaux de rayonnement. Ces dispositifs sont approximativement
de la taille d’un téléphone portable, ils peuvent être portés à la ceinture ou dans une poche pour une
utilisation mains libres et alerter l’opérateur en cas de présence de matières radioactives. En raison
de leur petite taille, ces dispositifs sont parfaitement adaptés à l’utilisation par des agents de l’autorité
ou des frontières et par les premiers intervenants, comme des agents de terrain ou des pompiers. De
plus, leur utilisation ne nécessite pas de formation approfondie. Certains de ces dispositifs peuvent
également permettre d’identifier des radionucléides.
Il existe différents types d’instruments individuels de détection du rayonnement. Même s’ils sont
similaires en apparence, ils doivent répondre à des types d’exigences différents. Ceux-ci peuvent inclure:
a) les détecteurs individuels de rayonnement (PRD);
b) les détecteurs individuels spectrométriques de rayonnement (SPRD);
c) les dosimètres individuels électroniques (EPD);
d) les détecteurs individuels de rayonnement à portée étendue (ER-PRD);
e) les détecteurs individuels de rayonnement d’urgence (PERD).
Un PRD est un dispositif petit, léger, robuste qui avertit son porteur de la présence de niveaux de
rayonnement supérieurs au bruit de fond provenant de rayonnements X et gamma, et dans certains cas
pour les neutrons. Les SPRD ont les mêmes fonctionnalités que les PRD, mais peuvent en plus identifier
les radionucléides. Les EPD sont conçus pour être portés par les travailleurs dans des situations
prévues d’exposition aux rayonnements, afin de mesurer leur dose individuelle. Les ER-PRD sont des
instruments à double détecteur qui étendent la plage de mesure d’un PRD sans perdre la sensibilité aux
faibles débits de dose. Les PERD sont conçus pour mesurer la dose individuelle. Ces dispositifs peuvent
afficher la dose de rayonnement et le débit de dose. Sa fonction d’alarme peut fonctionner si la dose ou
le débit de dose dépasse un seuil prédéfini et peut être utilisée comme outil de surveillance de la dose
délivrée aux intervenants.
4.3.2.2 Fonctionnement
Les PRD, ER-PRD et SPRD sont généralement utilisés pour surveiller les mouvements non déclarés et les
trafics illicites de matières radioactives. Il convient de porter les PRD sur le corps, idéalement sur le torse,
dans une poche, tenu par une cordelette, à la ceinture ou avec toute autre méthode sécurisée similaire.
Il convient qu’un système d’autotest permette de vérifier le bon fonctionnement de l’instrument (ainsi
que le niveau de charge de la batterie) avant utilisation. De fausses alarmes, c’est-à-dire des alarmes qui
surviennent en l’absence de matières radioactives, peuvent se produire occasionnellement en raison
de fluctuations du bruit de fond radioactif. Lorsque le seuil d’alarme est réglé correctement, il convient
qu’il ne se produise pas plus d’une fausse alarme par jour. Il existe toujours un compromis entre la
sensibilité de détection et les fausses alarmes. Occasionnellement, des rayonnements qui déclenchent
des alarmes innocentes peuvent être détectés. Cela tient au fait que de nombreux objets, tels que les
denrées alimentaires, la vaisselle, les tuiles, le béton, les engrais, la fonte des glaces, le sable, la litière
pour chats, etc., contiennent de petites quantités de matière radioactive du type potassium, radium,
thorium ou uranium. Par ailleurs, les personnes qui ont subi une radiothérapie ou un diagnostic peuvent
être source de rayonnement. Dans certains cas, lorsque le traitement ou le diagnostic a été effectué
récemment, les niveaux de radiation peuvent être élevés.
4.3.2.3 Étalonnage et vérification de routine
La plupart des instruments individuels de détection du rayonnement effectuent une autovérification
de routine à leur mise en marche. Pour pouvoir continuer à détecter les rayonnements, il convient
de vérifier un instrument individuel de détection du rayonnement quotidiennement ou avant son
utilisation, si possible. Des essais de fonctionnalité peuvent être effectués sur ces dispositifs pour
s’assurer qu’ils répondent correctement. Cela peut être effectué en plaçant l’instrument à proximité
d’une source de vérification de faible activité de rayonnement ou de matières radioactives naturelles
(MRN) (voir Annexe C) et en vérifiant sa réponse au rayonnement. Il convient de se conformer aux
recommandations du fabricant. Sources de vérification appropriées (voir Référence [14]), avec une
sortie suffisante pour permettre une lecture significative sur les instruments utilisés, sont très utiles.
Comme la plupart des détecteurs de rayonnements, il est recommandé d’étalonner régulièrement les
EPD (conformément aux exigences de l’autorité réglementaire nationale).
4.3.2.4 Exigences de performance minimale et méthodes d’essai
Les PRD doivent répondre aux exigences de performance décrites dans l’IEC 62401, les SPRD sont
couverts par l’IEC 62618 et les EPD sont couverts par l’IEC 61526 et l’IEC 62387. Ces documents
décrivent également les méthodes d’essai associées.
4.3.3 Instruments portables
4.3.3.1 Caractéristiques générales
Les instruments portables assurent une sensibilité de détection supérieure à celle des PRD, mais ils
sont plus lourds et généralement plus chers. Ils seraient par exemple choisis:
a) lorsqu’il existe déjà un soupçon de trafic illicite sur la base de rapports de r
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...