Cardiovascular implants — Endovascular devices — Part 2: Vascular stents

ISO 25539-2:2008 specifies requirements for vascular stents, based upon current medical knowledge. With regard to safety, it gives requirements for intended performance, design attributes, materials, design evaluation, manufacturing, sterilization packaging and information supplied by the manufacturer. It should be considered as a supplement to ISO 14630, which specifies general requirements for the performance of non-active surgical implants. The scope of ISO 25539-2:2008 includes vascular stents used to treat vascular lesions or stenoses, or other vascular abnormalities. These devices might or might not incorporate surface modifications of the stent such as drug and/or other coatings. Stents covered with materials that significantly modify the permeability of the uncovered stent are within the scope of ISO 25539-1:2003. The stent design might dictate the need to address functional requirements identified in both ISO 25539-1:2003 and ISO 25539-2:2008. Delivery systems are included in ISO 25539-2:2008 if they comprise an integral component of the deployment of the vascular stent. Some pharmacological aspects of drug eluting stents are addressed in ISO 25539-2:2008, but this document is not comprehensive with respect to the pharmacological evaluation of drug eluting stents. With the exception of sterilization, ISO 25539-2:2008 does not address requirements for the evaluation of animal tissue products.

Implants cardiovasculaires — Dispositifs endovasculaires — Partie 2: Stents vasculaires

L'ISO 25539-2:2008 spécifie les exigences relatives aux stents vasculaires selon les connaissances médicales actuelles. En ce qui concerne la sécurité, elle donne les exigences relatives aux performances attendues, aux caractéristiques de conception, aux matériaux, à l'évaluation de la conception, à la fabrication, à la stérilisation, à l'emballage et aux informations fournies par le fabricant. Il convient de la considérer comme un complément à l'ISO 14630 qui spécifie les exigences générales relatives aux performances des implants chirurgicaux non actifs. Le domaine d'application de l'ISO 25539-2:2008 inclut les stents utilisés dans le traitement des lésions vasculaires ou sténoses, ou d'autres anomalies vasculaires. Ces dispositifs peuvent comprendre ou non, des modifications de surface du stent telles qu'un revêtement renfermant ou non un médicament. Les stents recouverts de matériaux qui modifient sensiblement l'étanchéité du stent nu sont compris dans le domaine d'application de l'ISO 25539-1:2003. La conception des stents peut rendre nécessaire d'analyser les exigences fonctionnelles identifiées à la fois dans l'ISO 25539-1:2003 et dans l'ISO 25539-2:2008. Les systèmes d'injection sont inclus dans l'ISO 25539-2:2008 s'ils comprennent un composant intégral du déploiement du stent vasculaire. Certains aspects pharmacologiques des stents à élution de médicaments sont traités dans l'ISO 25539-2:2008, mais celle-ci ne détaille pas l'évaluation pharmacologique de ce type de stent. À l'exception de la stérilisation, l'ISO 25539-2:2008 ne traite pas les exigences relatives à l'évaluation des produits de tissus animaux.

General Information

Status
Withdrawn
Publication Date
25-Aug-2008
Withdrawal Date
25-Aug-2008
Current Stage
9599 - Withdrawal of International Standard
Completion Date
05-Dec-2012
Ref Project

Relations

Buy Standard

Standard
ISO 25539-2:2008 - Cardiovascular implants -- Endovascular devices
English language
93 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 25539-2:2008 - Implants cardiovasculaires -- Dispositifs endovasculaires
French language
105 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 25539-2
First edition
2008-09-01


Cardiovascular implants — Endovascular
devices —
Part 2:
Vascular stents
Implants cardiovasculaires — Dispositifs endovasculaires —
Partie 2: Endoprothèses vasculaires




Reference number
ISO 25539-2:2008(E)
©
ISO 2008

---------------------- Page: 1 ----------------------
ISO 25539-2:2008(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.


COPYRIGHT PROTECTED DOCUMENT


©  ISO 2008
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland

ii © ISO 2008 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 25539-2:2008(E)
Contents Page
Foreword. iv
Introduction . v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions. 2
4 General requirements. 4
4.1 Classification. 4
4.2 Size. 5
4.3 Intended clinical use designation . 5
5 Intended performance . 5
6 Design attributes. 5
6.1 General. 5
6.2 Delivery system and stent system . 6
6.3 Implant . 6
7 Materials . 7
8 Design evaluation . 8
8.1 General. 8
8.2 Sampling. 8
8.3 Conditioning of test samples . 9
8.4 Reporting . 9
8.5 Delivery system and stent system . 10
8.6 Stent . 15
8.7 Preclinical in vivo evaluation. 24
8.8 Clinical evaluation . 28
9 Post market surveillance . 31
10 Manufacturing . 32
11 Sterilization. 32
11.1 Products supplied sterile. 32
11.2 Products supplied non-sterile . 32
11.3 Sterilization residuals. 32
12 Packaging . 32
12.1 Protection from damage in storage and transport. 32
12.2 Marking . 33
12.3 Information supplied by the manufacturer . 34
Annex A (informative) Attributes of endovascular devices — Vascular stents — Technical and
clinical considerations . 36
Annex B (informative) Bench and analytical tests. 42
Annex C (informative) Definitions of reportable clinical events. 45
Annex D (informative) Test methods. 48
Annex E (informative) Supplement to fatigue durability test analytical approach. 86
Bibliography . 89

© ISO 2008 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 25539-2:2008(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 25539-2 was prepared by Technical Committee ISO/TC 150, Implants for surgery, Subcommittee SC 2,
Cardiovascular implants and extracorporeal systems.
ISO 25539 consists of the following parts, under the general title Cardiovascular implants — Endovascular
devices:
⎯ Part 1: Endovascular prostheses
⎯ Part 2: Vascular stents

iv © ISO 2008 – All rights reserved

---------------------- Page: 4 ----------------------
ISO 25539-2:2008(E)
Introduction
This part of ISO 25539 has been prepared in order to provide minimum requirements for endovascular
devices and the methods of test that will enable their evaluation. It is the second part of a proposed three-part
standard. ISO 25539-1 addresses endovascular prostheses and ISO 25539-3 will address vena cava filters.
ISO/TS 15539, from which this part of ISO 25539 is derived, serves as a rationale for the requirements of this
document. The Technical Specification ISO/TS 15539 was developed by first identifying the design
requirements for these devices and listing the potential device and clinical failure modes. Tests were then
identified to address each of the failure modes. The requirements provided in this part of ISO 25539 are based
on that assessment.


© ISO 2008 – All rights reserved v

---------------------- Page: 5 ----------------------
INTERNATIONAL STANDARD ISO 25539-2:2008(E)

Cardiovascular implants — Endovascular devices —
Part 2:
Vascular stents
1 Scope
1.1 This part of ISO 25539 specifies requirements for vascular stents, based upon current medical
knowledge. With regard to safety, it gives requirements for intended performance, design attributes, materials,
design evaluation, manufacturing, sterilization, packaging and information supplied by the manufacturer. It
should be considered as a supplement to ISO 14630, which specifies general requirements for the
performance of non-active surgical implants.
NOTE Due to the variations in the design of implants covered by this part of ISO 25539 and in some cases due to the
relatively recent development of some of these implants (e.g. bioabsorbable stents, polymeric stents), acceptable
standardized in vitro tests and clinical results are not always available. As further scientific and clinical data become
available, appropriate revision of this document will be necessary.
1.2 The scope of this part of ISO 25539 includes vascular stents used to treat vascular lesions or stenoses,
or other vascular abnormalities. These devices might or might not incorporate surface modifications of the
stent such as drug and/or other coatings. Stents covered with materials that significantly modify the
permeability of the uncovered stent are within the scope of ISO 25539-1. The stent design might dictate the
need to address functional requirements identified in both ISO 25539-1 and this part of ISO 25539.
1.3 Delivery systems are included in this part of ISO 25539 if they comprise an integral component of the
deployment of the vascular stent.
1.4 Procedures and devices used prior to the introduction of the vascular stent, such as balloon angioplasty
devices, are excluded from the scope of this part of ISO 25539.
1.5 Some pharmacological aspects of drug eluting stents are addressed in this part of ISO 25539, but this
document is not comprehensive with respect to the pharmacological evaluation of drug eluting stents.
1.6 Degradation and other time-dependent aspects of bioabsorbable and polymeric stents and coatings are
not addressed by this part of ISO 25539.
1.7 With the exception of sterilization, this part of ISO 25539 does not address requirements for the
evaluation of animal tissue products.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 10993 (all parts), Biological evaluation of medical devices
ISO 11135-1, Sterilization of health care products — Ethylene oxide — Part 1: Requirements for development,
validation and routine control of a sterilization process for medical devices
© ISO 2008 – All rights reserved 1

---------------------- Page: 6 ----------------------
ISO 25539-2:2008(E)
ISO 11137-1, Sterilization of health care products — Radiation — Part 1: Requirements for development,
validation and routine control of a sterilization process for medical devices
ISO 11607 (both parts), Packaging for terminally sterilized medical devices
ISO 14155 (both parts), Clinical investigation of medical devices for human subjects
ISO 14160, Sterilization of single-use medical devices incorporating materials of animal origin — Validation
and routine control of sterilization by liquid chemical sterilants
ISO 14630, Non-active surgical implants — General requirements
ISO 14937, Sterilization of health care products — General requirements for characterization of a sterilizing
agent and the development, validation and routine control of a sterilization process
ISO 14971, Medical devices — Application of risk management to medical devices
ISO 17665-1, Sterilization of health care products — Moist heat — Part 1: Requirements for the development,
validation and routine control of a sterilization process for medical devices
3 Terms and definitions
For the purposes of this document, the terms and definitions in ISO 14630 and the following apply.
NOTE Bench and analytical tests are described in Annex B. Reportable clinical events are defined in Annex C.
3.1
balloon-assisted deployment
use of a balloon to facilitate the complete deployment (or expansion) of a self-expanding stent
3.2
balloon winging
cross-sectional shape of the balloon when deflated which can cause problems during withdrawal
NOTE Examples include stent migration, damage to host vessel or balloon, and inability to remove the balloon.
3.3
delivery system
system or mechanism used to deliver the stent to the targeted position and to deploy the stent
NOTE The delivery system is removed after stent placement. Examples of delivery systems include balloon catheters
or mechanically activated systems.
3.4
determine
to quantitatively appraise or analyse
NOTE Also see evaluate (3.8).
3.5
dogboning
dumbbell-shaped balloon observed during stent deployment when the unconstrained ends of the balloon
expand beyond the dilated stent outer diameter
2 © ISO 2008 – All rights reserved

---------------------- Page: 7 ----------------------
ISO 25539-2:2008(E)
3.6
coating
organic or inorganic material, other than living cells, intentionally applied by a manufacturer to a substrate
NOTE This coating can be intended to be permanent or temporary, and can be applied to the external and/or internal
surface.
3.7
drug content
amount of drug present on the surface(s) of a coating, as part of a coating or within the stent
3.8
evaluate
to qualitatively appraise or analyse
NOTE Also see determine (3.4).
3.9
lumen reduction
reduction of diameter or cross sectional area as observed by imaging
3.10
reportable clinical events
complications, failures or device-related observations, including all adverse events and adverse device effects,
that might be observed with clinical use of the stent system
NOTE Examples are listed in Annex C. These events might not have clinical significance and might not be
attributable to the device.
3.11
stent configuration
stent shape (e.g. cylindrical, tapered, flared, coiled, segmented, bifurcated)
3.12
stent outer surface area
contact area between the stent and the vessel
3.13
stent-free surface area
percentage of surface area of cylinder formed by the implant frame, which is not covered by implant material
3.14
stent system
vascular stent and its delivery system or a vascular stent mounted on the delivery balloon as specified in the
instructions for use (IFU)
3.15
vascular stent
stent
implant
transluminally placed balloon-expandable or self-expanding implant, which is used to treat vascular lesions by
providing a mechanical support after deployment to maintain or restore vessel integrity
NOTE 1 Stents can or cannot incorporate surface modifications of the stent such as drug and/or other coatings.
NOTE 2 The following stent types are within the Scope of this part of ISO 25539.
3.15.1
articulated stent
stent constructed of segments with distinct connections
© ISO 2008 – All rights reserved 3

---------------------- Page: 8 ----------------------
ISO 25539-2:2008(E)
3.15.2
bare stent
stent without a coating or covering
NOTE Bare stents can be constructed of single or multiple materials.
3.15.3
bioabsorbable stent
stent that is designed to be a temporary structure without requiring explantation
3.15.4
balloon-expandable stent
stent where the diameter is increased from its pre-deployed size to its post-deployed size with the aid of a
balloon catheter
3.15.5
coated stent
stent with a surface layer of an additional material(s) that does not provide significant (e.g. more than 5 %)
structural support or appreciably reduce the permeability or stent-free surface area of the bare stent
3.15.6
composite stent
stent consisting of more than one material or material compound that provides significant (e.g. more than 5 %)
overall structural support upon deployment
3.15.7
covered stent
stent covered with an additional material(s) that appreciably reduces the permeability and/or eliminates the
stent-free surface area of the bare stent
NOTE Covered stents are within the Scope of ISO 25539-1. The stent design might dictate the need to address
functional requirements identified in both parts 1 and 2 of ISO 25539.
3.15.8
drug eluting stent
DES
stent that delivers a drug(s) over time
3.15.9
self-expanding stent
stent where the diameter increases from its pre-deployed size to its post-deployed size when released from
the delivery mechanism in absence of balloon inflation or other mechanical assistance
NOTE Self-expanding stents are within the scope of ISO 25539-1. The stent design might dictate the need to
address functional requirements identified in both parts 1 and 2 of ISO 25539.
4 General requirements
4.1 Classification
A stent shall be designated by its configuration (see 3.11), type (see 3.15), materials of construction, and any
surface modifications, coatings, and/or drugs.
4 © ISO 2008 – All rights reserved

---------------------- Page: 9 ----------------------
ISO 25539-2:2008(E)
4.2 Size
The size of a stent shall be designated by the following characteristics:
a) external diameter;
1) self-expanding:
i) unconstrained external diameter of the device, expressed in millimetres;
ii) intended vessel lumen diameter range, expressed in millimetres;
2) balloon expandable: range of intended expanded internal diameters;
b) minimum and maximum usable length, expressed in millimetres or centimetres.
4.3 Intended clinical use designation
The intended clinical use shall be designated by one or more of the following:
a) abdominal aorta;
b) arterio-venous shunt for vascular access;
c) carotid;
d) coronary;
e) femoral;
f) iliac;
g) popliteal;
h) renal;
i) thoracic aorta;
j) thoraco-abdominal aorta;
k) tibial;
l) other arterial vessels to be specified;
m) other venous vessels to be specified.
5 Intended performance
The requirements for intended performance of ISO 14630 shall apply.
6 Design attributes
6.1 General
The requirements for design attributes of ISO 14630 apply. In addition, the following shall be taken into
account:
a) oxidation-potential, the possibility of crevice corrosion, passivation over the relevant parts;
b) fretting, galvanic and pitting corrosion;
© ISO 2008 – All rights reserved 5

---------------------- Page: 10 ----------------------
ISO 25539-2:2008(E)
c) interface between implant and body:
1) fixation hooks if present;
2) relative movement between stent and tissue;
3) forces exerted by the stent on the surrounding tissue;
4) forces required to deform the stent if the deformation is permanent;
d) expected ingrowth, penetration, perforation, tilting and migration; introduction and delivery systems.
[15]
NOTE These additional items are adapted from Clause 5 of EN 12006-3:1998 .
The design attributes for vascular stents (with or without delivery system) are listed in Table A.2 with reference
to the test sections for the evaluation of the design (Clause 8). It is recognised that not all tests identified in a
category will be necessary or practical for any given stent and/or delivery system. The tests considered and
the rationale for selection and/or waiving of tests shall be recorded.
6.2 Delivery system and stent system
The design attributes to meet the intended performance of the delivery system shall additionally take into
account at least the following:
a) the ability of the system to permit consistent, accurate and safe access to the intended location;
b) the ability of the system to permit consistent, accurate and safe deployment of the stent;
c) the ability of the system to permit consistent and safe withdrawal of the delivery system;
d) the compliance of the system with the requirements of ISO 10993-1 and appropriate other parts of the
ISO 10993 series of International Standards (biocompatibility);
e) the ability of the system to minimise blood loss (haemostasis);
f) the visibility of the system under fluoroscopy or other technologies.
6.3 Implant
6.3.1 Stent
The design attributes to meet the intended performance of the stent shall additionally take into account at
least the following:
a) the ability of the stent to be consistently, accurately and safely deployed;
b) the ability of the stent to ensure effective fixation and apposition in the intended location within the
vasculature;
c) the ability of the stent to maintain adequate integrity;
d) the consistency of the stent dimensions and its design for compatibility for use in specified vessel
diameters;
e) the ability of the stent to maintain adequate blood flow through the lumen (patency);
f) the compatibility of the stent with exposure to magnetic resonance imaging (MRI) fields;
6 © ISO 2008 – All rights reserved

---------------------- Page: 11 ----------------------
ISO 25539-2:2008(E)
g) the compliance of the stent with the requirements of ISO 10993-1 and appropriate other parts of the
ISO 10993 series of International Standards (biocompatibility);
h) the visibility of the stent under fluoroscopy or other technologies.
6.3.2 Coating
The design attributes to meet the intended performance of the coating shall additionally take into account at
least the following:
a) the ability of the coating to maintain adequate integrity over time according to design specifications
(e.g. freedom from significant delamination, flaps and bare spots);
b) the appropriate interaction between the coating and the stent (e.g. coating influenced corrosion of the
substrate);
c) the ability of the coating to maintain adequate resistance to unintended particulate generation;
d) the conformance of the coating dimensions and other coating parameters (e.g. porosity, density,
distribution) to the design requirements;
e) the effect of MRI on the coating of a coated stent (e.g. heating).
6.3.3 Drug
The design attributes to meet the intended performance of the stent if the coating is a drug or if a drug is
incorporated into the stent or coating shall additionally take into account at least the following:
a) the ability to reproducibly apply the desired drug type and amount to the stent;
b) the ability to release the desired amount of drug over the specified amount of time;
c) the conformance of the residual drug quantity to design specifications;
d) the freedom of the drug(s) from deleterious impurity and degradant levels at manufacture and with
storage;
e) the appropriate interaction between the drug and the coating and/or the stent to which the drug is applied;
f) the effect of MRI on the drug of a drug-eluting stent (e.g. heating).
7 Materials
The requirements for materials of ISO 14630 apply. Additional testing specific to certain materials (e.g. metals,
polymers, drugs) shall be performed to determine the appropriateness of the material for use in the design.
For example, Nitinol materials dependent on shape memory properties shall be subjected to testing in order to
assess transformation properties. In addition, for drug-eluting stents drug identity testing shall be performed,
including the identification of impurities and degradants. Electro-chemical potentials of differing metals (stents,
guidewires, other accessory devices) might require additional types of testing.
© ISO 2008 – All rights reserved 7

---------------------- Page: 12 ----------------------
ISO 25539-2:2008(E)
8 Design evaluation
8.1 General
The requirements for design evaluation of ISO 14630 apply. A risk assessment shall be carried out and the
requirements of ISO 14971 shall apply.
Justification shall be provided for the properties not measured.
NOTE 1 All testing might not be appropriate for all stent system designs.
It is impossible to take into consideration all future and emerging technologies. The stent systems based on
these new technologies will need to be evaluated following the basic requirements of this part of ISO 25539.
Testing beyond the scope of this part of ISO 25539 might also be necessary in order to characterize these
stent systems. Consideration shall be given to the failure modes of the stent systems and their effects on the
performance of the implant in identifying the appropriate testing.
Whenever changes are made in materials, construction, configuration, application or processing methods, an
appropriate analysis of the potential impact of the change on the failure modes and performance of the stent
system shall be performed. Appropriate testing shall be conducted as deemed necessary.
The use of a control device for comparison should be considered in the evaluation of certain design attributes.
If overlapping of stents can be anticipated in clinical use (e.g. superficial femoral artery, coronary), integrity of
the stent under study in overlapping configurations should be evaluated, unless justification can be provided
for testing of individual stents. If overlapping with a different device is specifically indicated, testing should
include evaluation with the indicated device.
Testing to establish the labelled shelf-life shall be conducted by repeating appropriate tests. Justification for
the selection of tests shall be provided. For drug eluting stents, real time and accelerated testing conditions
should be used to define drug attributes for product shelf life.
1) [35] [36]
NOTE 2 Additional guidance for stability testing of drug products can be found in ICH Q1A (R2), ICH Q1B , and
[37]
ICH Q1D .
8.2 Sampling
A sampling plan shall be utilized which will ensure that adequate representation of the data has been obtained
for each parameter measured. The design characteristics of the stent (including any drugs and/or coatings),
delivery system and stent system shall be verified to be representative of the devices to be released for
distribution, including all sizes, configurations and components.
The sampling shall fully represent the range of device designs and might not necessarily require the testing of
each size. The stent sizes selected for testing shall represent the worst case combination(s) of diameter and
length for each test. A rationale shall be provided for sample selection. It might be necessary to conduct an
assessment to identify the size(s) of the device with the greatest potential for failure.
Sampling shall ensure adequate representation of the expected variability in the manufacture of devices.
For those tests with specified confidence and reliability parameters, the sample size shall have a statistical
basis. For all tests, the number of samples shall be justified.

1) International Conference on Harmonisation guidelines.
8 © ISO 2008 – All rights reserved

---------------------- Page: 13 ----------------------
ISO 25539-2:2008(E)
8.3 Conditioning of test samples
All samples shall be subj
...

NORME ISO
INTERNATIONALE 25539-2
Première édition
2008-09-01


Implants cardiovasculaires — Dispositifs
endovasculaires —
Partie 2:
Stents vasculaires
Cardiovascular implants — Endovascular devices —
Part 2: Vascular stents



Numéro de référence
ISO 25539-2:2008(F)
©
ISO 2008

---------------------- Page: 1 ----------------------
ISO 25539-2:2008(F)
PDF – Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier
peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence
autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées
acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute
responsabilité en la matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info
du fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir
l'exploitation de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation,
veuillez en informer le Secrétariat central à l'adresse donnée ci-dessous.


DOCUMENT PROTÉGÉ PAR COPYRIGHT


©  ISO 2008
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit
de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Version française parue en 2009
Publié en Suisse

ii © ISO 2008 – Tous droits réservés

---------------------- Page: 2 ----------------------
ISO 25539-2:2008(F)
Sommaire Page
Avant-propos. iv
Introduction . v
1 Domaine d'application. 1
2 Références normatives . 2
3 Termes et définitions. 2
4 Exigences générales . 5
4.1 Classification. 5
4.2 Taille. 5
4.3 Définition de l'utilisation clinique prévue. 5
5 Performances attendues. 6
6 Attributs de conception. 6
6.1 Généralités . 6
6.2 Système d'injection et ensemble stent/dispositif d'injection. 6
6.3 Implant . 7
7 Matériaux . 8
8 Évaluation de la conception . 8
8.1 Généralités . 8
8.2 Échantillonnage . 9
8.3 Préparation des échantillons d'essai . 9
8.4 Rapport . 9
8.5 Système d'injection et ensemble stent/dispositif d'injection. 10
8.6 Stent . 17
8.7 Évaluation préclinique in vivo. 27
8.8 Évaluation clinique . 31
9 Pharmacovigilance . 35
10 Fabrication. 35
11 Stérilisation . 35
11.1 Produits fournis stériles . 35
11.2 Produits fournis non stériles. 36
11.3 Résidus de stérilisation . 36
12 Emballage . 36
12.1 Protection contre les dommages lors du stockage et du transport. 36
12.2 Marquage . 37
12.3 Notice d'informations du fabricant . 38
Annexe A (informative) Caractéristiques des dispositifs endovasculaires — Stents vasculaires —
Considérations techniques et cliniques. 40
Annexe B (informative) Essais in vitro et essais analytiques. 49
Annexe C (informative) Définition des événements cliniques à déclaration obligatoire. 53
Annexe D (informative) Méthodes d'essai . 56
Annexe E (informative) Informations complémentaires sur l'approche analytique employée lors
de l'essai de durabilité à la fatigue. 98
Bibliographie . 101

© ISO 2008 – Tous droits réservés iii

---------------------- Page: 3 ----------------------
ISO 25539-2:2008(F)
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée
aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du
comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec
la Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,
Partie 2.
La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur
publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres
votants.
L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de
droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne
pas avoir identifié de tels droits de propriété et averti de leur existence.
L'ISO 25539-2 a été élaborée par le comité technique ISO/TC 150, Implants chirurgicaux, sous-comité SC 2,
Implants cardiovasculaires et circuits extra-corporels.
L'ISO 25539 comprend les parties suivantes, présentées sous le titre général Implants cardiovasculaires —
Dispositifs endovasculaires:
⎯ Partie 1: Prothèses endovasculaires
⎯ Partie 2: Stents vasculaires
iv © ISO 2008 – Tous droits réservés

---------------------- Page: 4 ----------------------
ISO 25539-2:2008(F)
Introduction
La présente partie de l'ISO 25539 a été préparée afin de définir les exigences minimales relatives aux
dispositifs endovasculaires et aux méthodes d'essai qui permettront leur évaluation. Il s'agit de la deuxième
partie d'une norme proposée en trois parties. L'ISO 25539-1 traite des prothèses endovasculaires et
l'ISO 25539-3 traitera des filtres à veine cave. L'ISO/TS 15539, à partir de laquelle cette partie a été dérivée,
sert de justification aux exigences du présent document. L'ISO/TS 15539 a été élaborée d'abord en identifiant
les exigences de conception applicables à ces dispositifs et en énumérant les modes de défaillance cliniques
potentiels, tant matériels que cliniques. Des essais ont ensuite été identifiés pour traiter chaque mode de
défaillance. Les exigences fournies dans la présente partie de l'ISO 25539 sont basées sur cette évaluation.

© ISO 2008 – Tous droits réservés v

---------------------- Page: 5 ----------------------
NORME INTERNATIONALE ISO 25539-2:2008(F)

Implants cardiovasculaires — Dispositifs endovasculaires —
Partie 2:
Stents vasculaires
1 Domaine d'application
1.1 La présente partie de l'ISO 25539 spécifie les exigences relatives aux stents vasculaires selon les
connaissances médicales actuelles. En ce qui concerne la sécurité, elle donne les exigences relatives aux
performances attendues, aux caractéristiques de conception, aux matériaux, à l'évaluation de la conception, à
la fabrication, à la stérilisation, à l'emballage et aux informations fournies par le fabricant. Il convient de la
considérer comme un complément à l'ISO 14630 qui spécifie les exigences générales relatives aux
performances des implants chirurgicaux non actifs.
NOTE Les variations de conception des implants décrits dans la présente partie de l'ISO 25539, et dans certains cas,
les évolutions relativement récentes de certains implants (par exemple stents bioabsorbables, stents polymères), ont pour
conséquence qu'il n'existe pas toujours des essais in vitro normalisés adaptés et que des résultats cliniques ne sont pas
toujours disponibles. Au fur et à mesure que des données scientifiques et cliniques complémentaires deviendront
disponibles, il sera nécessaire de procéder à une révision appropriée du présent document.
1.2 Le domaine d'application de la présente partie de l'ISO 25539 inclut les stents utilisés dans le
traitement des lésions vasculaires ou sténoses, ou d'autres anomalies vasculaires. Ces dispositifs peuvent
comprendre ou non, des modifications de surface du stent telles qu'un revêtement renfermant ou non un
médicament. Les stents recouverts de matériaux qui modifient sensiblement l'étanchéité du stent nu sont
compris dans le domaine d'application de l'ISO 25539-1. La conception des stents peut rendre nécessaire
d'analyser les exigences fonctionnelles identifiées à la fois dans l'ISO 25539-1 et dans la présente partie de
l'ISO 25539.
1.3 Les systèmes d'injection sont inclus dans la présente partie de l'ISO 25539 s'ils comprennent un
composant intégral du déploiement du stent vasculaire.
1.4 Les modes opératoires et les dispositifs utilisés avant l'introduction du stent vasculaire, tels que les
dispositifs d'angioplastie transluminale percutanée, sont exclus du domaine d'application de la présente partie
de l'ISO 25539.
1.5 Certains aspects pharmacologiques des stents à élution de médicaments sont traités dans la présente
partie de l'ISO 25539, mais celle-ci ne détaille pas l'évaluation pharmacologique de ce type de stent.
1.6 La dégradation et d'autres aspects fonction du temps des stents bioabsorbables, des stents polymères
et des revêtements ne sont pas décrits par la présente partie de l'ISO 25539.
1.7 À l'exception de la stérilisation, la présente partie de l'ISO 25539 ne traite pas les exigences relatives à
l'évaluation des produits de tissus animaux.
© ISO 2008 – Tous droits réservés 1

---------------------- Page: 6 ----------------------
ISO 25539-2:2008(F)
2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent document. Pour les
références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition de la
publication à laquelle il est fait référence (y compris tous les amendements) s'applique.
ISO 10993 (toutes les parties), Évaluation biologique des dispositifs médicaux
ISO 11135-1, Stérilisation des produits de santé — Oxyde d'éthylène — Partie 1: Exigences de
développement, de validation et de contrôle de routine d'un processus de stérilisation pour des dispositifs
médicaux
ISO 11137-1, Stérilisation des produits de santé — Irradiation — Partie 1: Exigences relatives à la mise au
point, à la validation et au contrôle de routine d'un procédé de stérilisation pour les dispositifs médicaux
ISO 11607 (toutes les parties), Emballages des dispositifs médicaux stérilisés au stade terminal
ISO 14155 (toutes les parties), Investigation clinique des dispositifs médicaux pour sujets humains
ISO 14160, Stérilisation des dispositifs médicaux non réutilisables contenant des matières d'origine
animale — Validation et contrôle de routine de la stérilisation par agents stérilisants chimiques liquides
ISO 14630, Implants chirurgicaux non actifs — Exigences générales
ISO 14937, Stérilisation des produits de santé — Exigences générales pour la caractérisation d'un agent
stérilisant et pour le développement, la validation et la vérification de routine d'un processus de stérilisation
ISO 14971, Dispositifs médicaux — Application de la gestion des risques aux dispositifs médicaux
ISO 17665-1, Stérilisation des produits de santé — Chaleur humide — Partie 1: Exigences pour le
développement, la validation et le contrôle de routine d'un procédé de stérilisation des dispositifs médicaux
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions donnés dans l'ISO 14630 ainsi que les
suivants s'appliquent.
NOTE Les essais in vitro et les essais analytiques sont décrits dans l'Annexe B. Les événements cliniques à
déclaration obligatoire sont définis dans l'Annexe C.
3.1
déploiement assisté par ballonnet
usage d'un ballonnet pour faciliter le déploiement complet (ou expansion) d'un stent auto-expansible
3.2
défaut de repli du ballonnet
mauvais repli du ballonnet lors du dégonflage qui peut entraîner des problèmes au moment du retrait
NOTE Les exemples incluent la migration du stent, les dommages causés au vaisseau traité ou au ballonnet, et
l'incapacité à retirer le ballonnet.
3.3
système d'injection
système ou mécanisme utilisé pour amener le stent à l'endroit souhaité et le déployer
NOTE Le système d'injection est retiré après le déploiement du stent. Des exemples de systèmes d'injection incluent
les cathéters à ballonnet ou les systèmes activés mécaniquement.
2 © ISO 2008 – Tous droits réservés

---------------------- Page: 7 ----------------------
ISO 25539-2:2008(F)
3.4
déterminer
évaluer ou analyser quantitativement
NOTE Voir aussi évaluer (3.8).
3.5
«dogboning»
dilatation observée pendant le déploiement du ballonnet lorsque ses extrémités se gonflent en forme d'haltère
de part et d'autre du diamètre extérieur du stent
3.6
revêtement
matériau organique ou inorganique, autre que des cellules vivantes, appliqué volontairement à un substrat par
un fabricant
NOTE Ce revêtement peut être prévu pour être permanent ou temporaire, et peut être appliqué à la surface externe
et/ou interne.
3.7
concentration en médicament
quantité de médicament présente à la surface d'un revêtement, en tant que partie d'un revêtement ou dans le
stent
3.8
évaluer
évaluer ou analyser qualitativement
NOTE Voir aussi déterminer (3.4).
3.9
réduction de la lumière interne du vaisseau
réduction du diamètre ou de la section transversale d'un vaisseau telle qu'observée par imagerie
3.10
événement clinique à déclaration obligatoire
complication, défaillance ou observation relatives au dispositif, y compris tous les événements indésirables et
les effets indésirables du dispositif, pouvant être observés lors de l'utilisation clinique de l'ensemble
stent/dispositif d'injection
NOTE Des exemples sont cités dans l'Annexe C. Ces événements peuvent ne pas avoir de signification clinique et
peuvent ne pas être attribuables au dispositif.
3.11
configuration du stent
forme du stent (par exemple cylindrique, conique, évasé, spiralé, segmenté, bifurqué)
3.12
surface externe du stent
zone de contact entre le stent et le vaisseau
3.13
surface du vaisseau sans contact avec le stent
rapport entre la surface totale couverte par le stent et la surface de son maillage
3.14
ensemble stent/dispositif d'injection
ensemble du stent vasculaire et de son dispositif d'injection ou ensemble du stent vasculaire monté sur son
ballonnet d'injection comme spécifié dans les instructions d'utilisation
© ISO 2008 – Tous droits réservés 3

---------------------- Page: 8 ----------------------
ISO 25539-2:2008(F)
3.15
stent vasculaire
stent
implant
implant auto-expansible ou expansible sur ballonnet, mis en place par voie endovasculaire, utilisé dans le
traitement des lésions vasculaires pour maintenir ou restaurer l'intégrité des vaisseaux en leur assurant un
support mécanique
NOTE 1 Les stents peuvent ou non inclure des modifications de leur surface telles que des revêtements renfermant un
médicament et/ou d'autres types de revêtement.
NOTE 2 Les familles de stents suivantes font partie du domaine d'application de la présente partie de l'ISO 25539.
3.15.1
stent articulé
stent à cellules ouvertes
stent composé de segments à connexions distinctes
3.15.2
stent nu
stent sans revêtement ou non couvert
NOTE Les stents nus peuvent être composés d'un seul ou de plusieurs matériaux.
3.15.3
stent bioabsorbable
stent conçu pour être une structure temporaire qui n'exige pas d'explantation
3.15.4
stent expansible sur ballonnet
stent monté sur un ballonet dont le gonflement fait passer le stent d'une dimension prédéployée à une
dimension finale
3.15.5
stent enduit
stent revêtu en surface par un ou des matériaux additionnels qui ne modifient pas de façon significative (par
exemple plus de 5 %) le support fourni par la structure ou qui ne réduisent pas de façon appréciable
l'étanchéité du stent nu ou l'importance de la surface du vaisseau sans contact avec le stent
3.15.6
stent composite
stent constitué de plusieurs matériaux ou de matériaux composites qui participent de façon significative (par
exemple plus de 5 %) au support fourni par la structure lors du déploiement
3.15.7
stent couvert
stent couvert par un ou des matériaux additionnels qui réduisent sensiblement l'étanchéité et/ou suppriment
tout contact du stent avec la paroi du vaisseau
NOTE Les stents couverts font partie du domaine d'application de l'ISO 25539-1. Selon la conception des stents, il
peut s'avérer nécessaire d'analyser les exigences fonctionnelles identifiées à la fois dans l'ISO 25539-1 et dans
l'ISO 25539-2.
3.15.8
stent à élution de médicaments
SEM
stent qui relargue un ou des médicaments au cours du temps
4 © ISO 2008 – Tous droits réservés

---------------------- Page: 9 ----------------------
ISO 25539-2:2008(F)
3.15.9
stent auto-expansible
stent dont le diamètre passe de la dimension prédéployée à la dimension post-déployée lorsqu'il est libéré du
système d'injection sans nécessiter l'assistance d'un ballonnet de dilatation ou d'un autre moyen mécanique
NOTE Les stents auto-expansibles font partie du domaine d'application de l'ISO 25539-1. Selon la conception des
stents, il peut s'avérer nécessaire d'analyser les exigences fonctionnelles identifiées à la fois dans l'ISO 25539-1 et dans
l'ISO 25539-2.
4 Exigences générales
4.1 Classification
Un stent doit être défini par sa forme (voir 3.11), son type (voir 3.15), les matériaux qui le constituent et par
toute modification de surface, tous revêtements et/ou toute présence de médicaments.
4.2 Taille
La taille d'un stent doit être définie à partir des caractéristiques suivantes:
a) diamètre extérieur:
1) stent auto-expansible:
i) diamètre extérieur non contraint du dispositif, exprimé en millimètres;
ii) plage des diamètres de vaisseau (lumière interne) compatibles avec le stent, exprimés en
millimètres;
2) stent expansible sur ballonnet: plage des diamètres internes après expansion;
b) longueurs utiles minimale et maximale, exprimées en millimètres ou en centimètres.
4.3 Définition de l'utilisation clinique prévue
L'utilisation clinique prévue doit être définie par un ou plusieurs des éléments suivants:
a) aorte abdominale;
b) fistule artério-veineuse pour accès vasculaire;
c) carotide;
d) coronaire;
e) fémorale;
f) iliaque;
g) poplitée;
h) rénale;
i) aorte thoracique;
j) aorte thoraco-abdominale;
© ISO 2008 – Tous droits réservés 5

---------------------- Page: 10 ----------------------
ISO 25539-2:2008(F)
k) tibiale;
l) autres vaisseaux artériels à spécifier;
m) autres vaisseaux veineux à spécifier.
5 Performances attendues
Les exigences relatives aux performances attendues de l'ISO 14630 doivent s'appliquer.
6 Attributs de conception
6.1 Généralités
Les exigences relatives aux caractéristiques de conception de l'ISO 14630 s'appliquent. De plus, les
exigences suivantes doivent être prises en compte:
a) potentiel d'oxydation, corrosion caverneuse, passivation des éléments correspondants;
b) corrosion par initiation de fissures dans la zone de frottement entre pièces soumises à des mouvements
de faible amplitude, corrosion galvanique, corrosion par piqûres;
c) interface entre l'implant et le corps humain:
1) crochets de fixation s'ils existent;
2) mouvement relatif entre le stent et les tissus;
3) forces exercées par le stent sur les tissus adjacents;
4) forces nécessaires pour déformer le stent de façon permanente;
d) potentiel de croissance à l'intérieur du stent, de pénétration, de perforation, de bascule et de migration;
systèmes d'introduction et de largage (systèmes d'injection).
[15]
NOTE Ces éléments additionnels sont adaptés de l'EN 12006-3:1998, Article 5 .
Les caractéristiques de conception des stents vasculaires (avec ou sans systèmes d'injection) sont données
dans le Tableau A.2 qui fait référence aux sections définissant les essais relatifs à l'évaluation de la
conception des dispositifs (Article 8). Il est admis que tous les essais identifiés dans une catégorie ne sont
pas nécessaires ou ne sont pas réalisables pour tous les stents et/ou pour tous les systèmes d'injection. Les
essais réalisés et la justification de leur choix ou de leur dispense doivent faire l'objet d'un enregistrement.
6.2 Système d'injection et ensemble stent/dispositif d'injection
Les caractéristiques de conception permettant de répondre aux performances attendues du système
d'injection doivent également prendre en compte, au moins les éléments suivants:
a) la capacité du système à assurer un accès fiable, précis et sûr au site d'implantation choisi;
b) la capacité du système à assurer un déploiement fiable, précis et sûr du stent;
c) la capacité du système à assurer un retrait fiable et sûr du système d'injection;
d) la conformité du système aux exigences de l'ISO 10993-1 et aux autres parties appropriées des autres
parties de la série de l'ISO 10993 (biocompatibilité);
6 © ISO 2008 – Tous droits réservés

---------------------- Page: 11 ----------------------
ISO 25539-2:2008(F)
e) la capacité du système à minimiser les pertes de sang (hémostase);
f) la visibilité du système sous fluoroscopie ou avec d'autres technologies de visualisation.
6.3 Implant
6.3.1 Stent
Les caractéristiques de conception permettant de répondre aux performances attendues du stent doivent
également prendre en compte au moins les éléments suivants:
a) la capacité du stent à être déployé de manière fiable, précise et sûre;
b) la capacité du stent à assurer une fixation et une apposition efficace à l'emplacement prévu dans le
système vasculaire;
c) la capacité du stent à conserver une intégrité appropriée;
d) la cohérence entre les dimensions du stent, sa conception et son usage dans les diamètres de vaisseau
spécifiés;
e) la capacité du stent à maintenir un flux sanguin approprié dans la lumière du vaisseau (perméabilité);
f) la compatibilité du stent à l'imagerie par résonance magnétique (IRM);
g) la conformité du stent aux exigences de l'ISO 10993-1 et aux autres parties appropriées de la série de
l'ISO 10993 (biocompatibilité);
h) la visibilité du stent sous fluoroscopie ou par l'utilisation d'autres technologies de visualisation.
6.3.2 Revêtement
Les caractéristiques de conception permettant de répondre aux performances attendues du revêtement
doivent également au moins prendre en compte les éléments suivants:
a) la capacité du revêtement à conserver au cours du temps une intégrité conforme aux spécifications de
conception (par exemple pas de délitage, décollement ou points non couverts significatifs);
b) l'absence d'interaction négative entre le revêtement et le stent (par exemple l'influence du revêtement sur
la corrosion du substrat);
c) la capacité du revêtement à conserver au cours du temps une résistance appropriée à la production de
particules non voulues;
d) la conformité des dimensions du revêtement et de ses autres paramètres (par exemple la porosité, la
densité, la distribution) aux exigences de la conception;
e) l'effet de l'IRM sur le revêtement d'un stent (par exemple l'échauffement).
6.3.3 Médicaments
Si le revêtement est un médicament ou si un médicament est incorporé au stent ou au revêtement, les
caractéristiques de conception permettant de répondre aux performances attendues du stent, doivent
également au moins prendre en compte les éléments suivants:
a) la capacité à appliquer de manière reproductible sur le stent le type et la quantité de médicament
souhaités;
© ISO 2008 – Tous droits réservés 7

---------------------- Page: 12 ----------------------
ISO 25539-2:2008(F)
b) la capacité à libérer la quantité souhaitée de médicament sur une durée de temps spécifiée;
c) la conformité de la quantité résiduelle de médicament aux spécifications de la conception;
d) l'absence, dans le ou les médicaments, de niveaux nocifs d'impuretés ou de produits de dégradation lors
de la fabrication et du stockage;
e) l'absence d'interaction négative entre le médicament et le revêtement et/ou le stent sur lequel est
appliqué le médicament;
f) l'effet de l'IRM sur le médicament d'un stent à élution de médicament (par exemple l'échauffement).
7 Matériaux
Les exigences de l'ISO 14630 relatives aux matériaux s'appliquent. Des essais complémentaires spécifiques
de certains matériaux (par exemple métaux, polymères, médicaments) doivent être réalisés afin de
déterminer si le matériau peut être utilisé pour la conception. Par exemple les matériaux à base de Nitinol
dotés d'une mémoire de forme doivent être soumis à des essais afin d'évaluer leurs propriétés de
transformation. De plus, en ce qui concerne les stents à élution de médicaments, des essais doivent être
réalisés pour identifier le médicament, y compris les impuretés et les produits de dégradation. Le potentiel
électrochimique des différents métaux (stents, guides et autres dispositifs auxiliaires) peut nécessiter des
essais complémentaires.
8 Évaluation de la
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.