Pneumatic fluid power — Five-port directional control valves — Part 1: Mounting interface surfaces without electrical connector — Technical Corrigendum 1

This part of ISO 5599 specifies the requirements for a mounting interface surface without electrical connector for fiveport pneumatic directional control valves, for use at a maximum rated pressure of [ 1)]. It gives
— dimensions and tolerances of the interface features,
— port identification, and
— identification of the result of control-mechanism actuation.
It is not applicable to the functional characteristics of interfaces.

Transmissions pneumatiques — Distributeurs à cinq orifices principaux — Partie 1: Plans de pose sans connecteur électrique — Rectificatif technique 1

Fluidna tehnika - Pnevmatika - Petpotni ventili - 1. del: Priključne površine brez električnih priključkov - Popravek

Ta del standarda ISO 5599 določa zahteve za priključno površino brez električnega priključka za petpotne pnevmatske ventile za uporabo pri največjem nazivnem tlaku [ 1)]. Vsebuje
– dimenzije in odstopanja za lastnosti vmesnika,
– opredelitev vhodov in
– opredelitev rezultata proženja nadzornega mehanizma.
Ne uporablja se za funkcijske značilnosti vmesnikov.

General Information

Status
Published
Publication Date
16-Jan-2007
Current Stage
6060 - International Standard published
Start Date
17-Jan-2007
Completion Date
12-Feb-2026

Relations

Effective Date
06-Jun-2022
Effective Date
12-May-2008
Effective Date
15-Apr-2008
Corrigendum

ISO 5599-1:2002/Cor 1:2014

English language
1 pages
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

Institut za varilstvo d.o.o. (Welding Institute)

Slovenia's leading welding institute since 1952. ISO 3834, EN 1090, pressure equipment certification, NDT personnel, welder qualification. Only IIW Au

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

ISO 5599-1:2001/Cor 1:2007 is a corrigendum published by the International Organization for Standardization (ISO). Its full title is "Pneumatic fluid power — Five-port directional control valves — Part 1: Mounting interface surfaces without electrical connector — Technical Corrigendum 1". This standard covers: This part of ISO 5599 specifies the requirements for a mounting interface surface without electrical connector for fiveport pneumatic directional control valves, for use at a maximum rated pressure of [ 1)]. It gives — dimensions and tolerances of the interface features, — port identification, and — identification of the result of control-mechanism actuation. It is not applicable to the functional characteristics of interfaces.

This part of ISO 5599 specifies the requirements for a mounting interface surface without electrical connector for fiveport pneumatic directional control valves, for use at a maximum rated pressure of [ 1)]. It gives — dimensions and tolerances of the interface features, — port identification, and — identification of the result of control-mechanism actuation. It is not applicable to the functional characteristics of interfaces.

ISO 5599-1:2001/Cor 1:2007 is classified under the following ICS (International Classification for Standards) categories: 23.100.50 - Control components. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 5599-1:2001/Cor 1:2007 has the following relationships with other standards: It is inter standard links to ISO 5599-1:2001; is excused to SIST ISO 5599-1:2002, ISO 5599-1:2001. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ISO 5599-1:2001/Cor 1:2007 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Transmissions pneumatiques - Distributeurs à cinq orifices principaux - Partie 1: Plans de pose sans connecteur électriquePneumatic fluid power - Five-port directional control valves - Part 1: Mounting interface surfaces without electrical connector23.100.50Krmilni sestavni deliControl componentsICS:Ta slovenski standard je istoveten z:ISO 5599-1:2001/Cor 1:2007SIST ISO 5599-1:2002/Cor 1:2014en,fr01-januar-2014SIST ISO 5599-1:2002/Cor 1:2014SLOVENSKI
STANDARD
ICS
23.100.50 Ref. No. ISO 5599-1:2001/Cor.1:2007(E)©
ISO 2007 – All rights reserved Published in Switzerland
INTERNATIONAL STANDARD ISO 5599-1:2001 TECHNICAL CORRIGENDUM 1 Published 2007-02-01 INTERNATIONAL ORGANIZATION FOR STANDARDIZATION •
• ORGANISATION INTERNATIONALE DE NORMALISATION
Pneumatic fluid p
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...