Electromagnetic compatibility (EMC) - Part 5-9: Installation and mitigation guidelines - System-level susceptibility assessments for HEMP and HPEM

IEC/TS 61000-5-9:2009(E) is to present a methodology to assess the impact of High-altitude Electromagnetic Pulse (HEMP) and High Power Electromagnetic (HPEM) environments on electronic systems. In this context a system refers to a collection of sub-systems, equipment and components brought together to perform a function. The techniques associated with this methodology and their advantages and disadvantages will be presented along with examples of how the techniques can be applied to evaluate the susceptibility of electronic systems such as those found in installations. This work is closely related to the evaluation of EMC system level susceptibility. The purpose of IEC/TS 61000-5-9:2009 is to provide information on available methods for the assessment of system-level susceptibility as a result of HEMP and HPEM environments. The advantages and disadvantages of the methods will be discussed along with examples of how the techniques should be employed. Typical systems have external connections, wired or wireless, and the assessment of these are included within this specification. IEC/TS 61000-5-9:2009 gives general guidance. It does not cover safety issues nor does it conflict with ITU-T efforts concerning the protection of telecommunications equipment. IEC/TS 61000-5-9:2009 has the status of a basic EMC publication in accordance with IEC Guide 107.

General Information

Status
Published
Publication Date
07-Jul-2009
Current Stage
PPUB - Publication issued
Start Date
31-Oct-2009
Completion Date
08-Jul-2009
Ref Project

Buy Standard

Technical specification
IEC TS 61000-5-9:2009 - Electromagnetic compatibility (EMC) - Part 5-9: Installation and mitigation guidelines - System-level susceptibility assessments for HEMP and HPEM
English language
66 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


IEC/TS 61000-5-9 ®
Edition 1.0 2009-07
TECHNICAL
SPECIFICATION
BASIC EMC PUBLICATION
Electromagnetic compatibility (EMC) –
Part 5-9: Installation and mitigation guidelines – System-level susceptibility
assessments for HEMP and HPEM
IEC/TS 61000-5-9:2009(E)
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC/TS 61000-5-9 ®
Edition 1.0 2009-07
TECHNICAL
SPECIFICATION
BASIC EMC PUBLICATION
Electromagnetic compatibility (EMC) –
Part 5-9: Installation and mitigation guidelines – System-level susceptibility
assessments for HEMP and HPEM
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
XB
ICS 33.100.20 ISBN 978-2-88910-396-6
– 2 – TS 61000-5-9 © IEC:2009(E)
CONTENTS
FOREWORD.5
INTRODUCTION.7
1 Scope.8
2 Normative references .8
3 Terms and definitions .9
4 General .11
4.1 Introduction .11
4.2 Systems and subsystems .12
5 Interaction mechanisms and protection methods .13
5.1 General .13
5.2 Front-door coupling .13
5.3 Back-door coupling.13
5.4 Protection methods .14
6 Description of overall assessment methodology .14
6.1 Methodology.14
6.2 Subsystems and equipment characterization phase.16
6.3 System analysis phase.17
6.4 System test phase.17
6.4.1 General .17
6.4.2 Low-level tests .18
6.4.3 High-level testing.18
6.5 Susceptibility assessment phase .20
6.6 The use of reverberation chambers to characterise immunity .20
Annex A (informative) Classification of effect .24
Annex B (informative) Good measurement practice.27
Annex C (informative) Computational electromagnetics .30
Annex D (informative) System level assessment – HEMP .33
Annex E (informative) System level assessment – HPEM .35
Annex F (informative) Limitations.39
Annex G (informative) Detailed description of low-level techniques.42
Annex H (informative) Detailed description of high-level test techniques .54
Annex I (informative) Data processing and analysis .61
Bibliography.66

Figure 1 – Example system architecture .
Figure 2 – Example of radiated HPEM at high frequencies [3].14
Figure 3 – Methodology flowchart .15
Figure 4 – Reverberation chamber results: all effects.21
Figure 5 – Reverberation chamber results: susceptibilities.22
Figure 6 – Frequency spectrum of several HPEM sources .23
Figure A.1 – Classification of effect.24
Figure B.1 – Effect of adding ferrites to connecting cable: swept frequency example .27

TS 61000-5-9 © IEC:2009(E) – 3 –
Figure B.2 – Effect of adding ferrite to connecting cable: reverberation chamber
example.28
Figure B.3 – Effect of adding ferrite to connecting cable: transient example (time
domain) .28
Figure B.4 – Effect of adding ferrite to connecting cable: transient example (frequency
domain) .29
Figure E.1 – Steps taken in the system assessment .36
Figure E.2 – Maximum free-space separation distances.38
Figure E.3 – Critical regions for permanent damage.38
Figure G.1 – Electromagnetic interaction sequence diagram for a facility illuminated by
an external antenna .43
Figure G.2 – Illustration of the difference of a directed, narrow-beam antenna exciting
the facility with a spot beam, along with a plane wave providing illumination to the
entire facility .45
Figure G.3 – Measurement equipment and configuration for measuring transient
responses in a buried facility, as reported by [G-6] .47
Figure G.4 – Example of a measured transient cable current (a) and the resulting
spectral magnitude, as computed by a Fourier transform (b) .48
Figure G.5 – Plots of the analytical pulser output open circuit voltage waveform (a)
and spectral magnitude (b), which are used as reference for computing the transfer
function T .48
sc
Figure G.6 – The radiated E-field from the IRA at a distance of 6 meters for the
analytical pulser excitation (a) and the resulting spectral magnitude (b).49
Figure G.7 – The spectral magnitude of the computed transfer function T (a) and the
sc
corresponding transient transfer function (b).49
Figure G.8 – The spectral magnitude of the computed transfer function T (a) and the
ec
corresponding transient transfer function (b).50
Figure G.9 – LLCW reference field measurement.51
Figure G.10 – LLCW induced current measurement .51
Figure G.11 – Typical magnitude-only transfer function.52
Figure H.1 – Microwave injection testing of a low noise amplifier, LNA [H-2]. LNA at
the tip of the arrow.54
Figure H.2 – Aircraft testing at the Swedish Microwave Test Facility, MTF [H-3] .55
Figure H.3 – Measured shielding effectiveness of an equipment compared to the MTF
test frequencies (dashed bars) [3].56
Figure H.4 – Reverberation chamber .58
Figure I.1 – Prediction of induced current using magnitude-only transfer functions [I-1] .61
Figure I.2 – IEC 61000-2-9 HEMP Waveform .62
Figure I.3 – Convolution process.62
Figure I.4 – Predicted induced current .63
Figure I.5 – Comparison of transfer function predictions with simulator measurements .64
Figure I.6 – Extrapolation of measured transients .65

– 4 – TS 61000-5-9 © IEC:2009(E)
Table A.1 – Categorisation of effect by criticality.25
Table A.2 – Categorisation of effect duration .26
Table A.3 – Combination of criticality level and duration category.26
Table I.1 – Comparison of transfer function predictions and simulator measured
currents .63

TS 61000-5-9 © IEC:2009(E) – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
ELECTROMAGNETIC COMPATIBILITY (EMC) –

Part 5-9: Installation and mitigation guidelines –
System-level susceptibility assessments for HEMP and HPEM

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for inte
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.