IEC 60998-2-3:2002
(Main)Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units
Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units
This standard applies to connecting devices with insulation piercing clamping units primarily suitable for connecting insulated unprepared conductors. In the connecting operation the insulation of the conductor is pierced, bored through, cut through, removed, displaced or made ineffective in some other manner at the point or points of contact. This Part 2-1 is intended to be used in conjunction with IEC 60998-1. It was established on the basis of the second edition (2002) of that standard. This second edition cancels and replaces the first edition published in 1991 and constitutes a technical revision. The contents of the corrigendum of November 2006 have been included in this copy.
Dispositifs de connexion pour circuits basse tension pour usage domestique et analogue - Partie 2-3: Règles particulières pour dispositifs de connexion en tant que parties séparées avec organes de serrage à perçage d'isolant
Cette norme s'applique aux dispositifs de connexion avec organes de serrage à perçage d'isolant principalement appropriés au raccordement de conducteurs isolés sans préparation. Lors de l'opération de raccordement, l'isolation du conducteur est percée, transpercée, découpée, enlevée, déplacée ou rendue inopérante d'une autre façon à l'endroit du ou des points de contact. La présente Partie 2-1 est destinée à être utilisée conjointement avec la CEI 60998-1. Elle a été établie sur la base de la deuxième édition (2002) de cette norme. Cette deuxième édition annule et remplace la première édition parue en 1991, dont elle constitue une révision technique. Le contenu du corrigendum de novembre 2006 a été pris en considération dans cet exemplaire.
General Information
- Status
- Published
- Publication Date
- 17-Dec-2002
- Technical Committee
- TC 23 - Electrical accessories
- Current Stage
- PPUB - Publication issued
- Start Date
- 18-Dec-2002
- Completion Date
- 31-Jan-2003
Relations
- Effective Date
- 05-Sep-2023
Overview
IEC 60998-2-3:2002 is an international standard published by the International Electrotechnical Commission (IEC) that specifies particular requirements for connecting devices with insulation-piercing clamping units. These connecting devices are designed for low-voltage circuits primarily used in household and similar applications. The standard addresses devices that connect insulated, unprepared conductors by piercing, removing, or otherwise effectively bypassing the conductor insulation at the points of contact, ensuring secure and reliable electrical connections.
This part (2-3) of IEC 60998 complements the general requirements established in IEC 60998-1 and reflects a technical revision replacing the first edition from 1991. The 2002 edition incorporates amendments, including corrigenda from 2006, to maintain consistency and enhance safety and performance requirements.
Key Topics
Scope and Application
IEC 60998-2-3 covers connecting devices as separate entities featuring insulation-piercing clamping units. The standard focuses on devices suitable for unprepared insulated conductor connections in low-voltage household circuits.Construction and Performance Requirements
Detailed requirements include mechanical construction, electrical performance, resistance to aging, moisture, ingress of solids and water, and thermal endurance. Attention is given to insulation resistance, dielectric strength, and mechanical robustness.Safety and Protection
The standard specifies protective measures against electric shock, including criteria for insulation and metal parts to prevent hazard during installation and use.Testing Procedures
IEC 60998-2-3 outlines test sequences and sampling methods to verify compliance, such as temperature rise tests, mechanical strength, insulation resistance, and resistance to environmental factors including heat and humidity.Marking and Classification
Requirements include clear marking of rated connecting capacity and conductor compatibility, enabling proper identification and correct application.Conductor Compatibility
The standard gives tables correlating rated connecting capacity with conductor sizes, including the relationship between cross-sectional mm² and North American Wire Gauge (AWG) sizes, ensuring global applicability.Electromagnetic Compatibility (EMC)
Provisions ensure that connecting devices meet electromagnetic emission and immunity requirements for safe household and industrial operation.
Applications
IEC 60998-2-3 applies primarily to:
- Electrical connectors in household low-voltage circuits where insulation-piercing units facilitate quick and reliable conductor connections without prior stripping of insulation.
- Installation in domestic environments and similar low-voltage applications requiring safety, reliability, and ease of use.
- Devices used by electricians and professionals needing standardized, tested components for wiring installations in residences, commercial buildings, and small industrial settings.
- Systems requiring compliance with international electrical safety and performance standards to assure quality and reduce risk of electric shock or fire.
By adhering to IEC 60998-2-3, manufacturers ensure that their insulation-piercing connecting devices deliver consistent performance, fit into the global market, and provide end-users with reliable and safe electrification solutions.
Related Standards
- IEC 60998-1: General requirements for connecting devices for low-voltage circuits for household and similar purposes. This standard sets baseline general provisions, and IEC 60998-2-3 builds upon these for devices with insulation-piercing clamping units.
- IEC 60364 series: Covers electrical installations in buildings, providing additional safety and design requirements relevant to connectors specified in IEC 60998 series.
- IEC 60529: Defines degrees of protection provided by enclosures (IP Code), relevant for evaluating ingress resistance in connectors.
- ISO/IEC Directives, Part 2: Outline preparation and maintenance of international standards ensuring compatibility of norm development.
- ISO 9001: Although not electrical-specific, this quality management standard supports manufacturing and compliance processes associated with IEC 60998 devices.
Keywords: IEC 60998-2-3, insulation-piercing clamping units, connecting devices, low-voltage circuits, household electrical connectors, conductor connection, electrical safety standards, IEC standards, low-voltage connection devices, international electrotechnical standard, electrical installation safety.
IEC 60998-2-3:2002 - Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units
Frequently Asked Questions
IEC 60998-2-3:2002 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units". This standard covers: This standard applies to connecting devices with insulation piercing clamping units primarily suitable for connecting insulated unprepared conductors. In the connecting operation the insulation of the conductor is pierced, bored through, cut through, removed, displaced or made ineffective in some other manner at the point or points of contact. This Part 2-1 is intended to be used in conjunction with IEC 60998-1. It was established on the basis of the second edition (2002) of that standard. This second edition cancels and replaces the first edition published in 1991 and constitutes a technical revision. The contents of the corrigendum of November 2006 have been included in this copy.
This standard applies to connecting devices with insulation piercing clamping units primarily suitable for connecting insulated unprepared conductors. In the connecting operation the insulation of the conductor is pierced, bored through, cut through, removed, displaced or made ineffective in some other manner at the point or points of contact. This Part 2-1 is intended to be used in conjunction with IEC 60998-1. It was established on the basis of the second edition (2002) of that standard. This second edition cancels and replaces the first edition published in 1991 and constitutes a technical revision. The contents of the corrigendum of November 2006 have been included in this copy.
IEC 60998-2-3:2002 is classified under the following ICS (International Classification for Standards) categories: 29.120.20 - Connecting devices. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 60998-2-3:2002 has the following relationships with other standards: It is inter standard links to IEC 60998-2-3:2002/COR1:2006. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC 60998-2-3:2002 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
IEC 60998-2-3 ®
Edition 2.0 2002-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connecting devices for low-voltage circuits for household and similar
purposes –
Part 2-3: Particular requirements for connecting devices as separate entities
with insulation-piercing clamping units
Dispositifs de connexion pour circuits basse tension pour usage domestique et
analogue –
Partie 2-3: Règles particulières pour dispositifs de connexion en tant que parties
séparées avec organes de serrage à perçage d'isolant
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
ƒ Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
ƒ Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
ƒ Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
ƒ Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 60998-2-3 ®
Edition 2.0 2002-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connecting devices for low-voltage circuits for household and similar
purposes –
Part 2-3: Particular requirements for connecting devices as separate entities
with insulation-piercing clamping units
Dispositifs de connexion pour circuits basse tension pour usage domestique et
analogue –
Partie 2-3: Règles particulières pour dispositifs de connexion en tant que
parties séparées avec organes de serrage à perçage d'isolant
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
S
CODE PRIX
ICS 29.120.20 ISBN 2-8318-6779-7
– 2 – 60998-2-3 © CEI:2002
SOMMAIRE
AVANT-PROPOS . 4
1 Domaine d'application. 8
2 Références normatives . 8
3 Définitions . 8
4 Généralités .10
5 Notes générales sur les essais .10
6 Caractéristiques principales.10
7 Classification .10
8 Marquage .12
9 Protection contre les chocs électriques .12
10 Raccordement des conducteurs .14
11 Construction .22
12 Résistance au vieillissement, à l'humidité, à la pénétration des corps solides
étrangers et à la pénétration nuisible de l'eau.22
13 Résistance d'isolement et rigidité diélectrique.24
14 Résistance mécanique.24
15 Echauffement et performances électriques .24
16 Résistance à la chaleur.28
17 Distances d'isolement dans l'air et lignes de fuite .28
18 Résistance de la matière isolante à la chaleur anormale et au feu .30
19 Résistance de la matière isolante aux courants de cheminement .30
20 Prescriptions CEM .30
Annexes.36
Annexe AA (normative) Séquences d'essais et lots d’échantillons.38
Annexe BB (informative) Relations approximatives entre les sections de conducteurs
en mm² et les tailles «American Wire Gauge» (AWG) utilisées en Amérique du Nord .40
Figure 101 – Appareil d'essai .30
Figure 102 – Exemple de point de mesure .32
Figure 103 – Exemple de DCPI .34
Tableau 101 – Capacité de connexion assignée et conducteurs raccordables .14
Tableau 102 – Diamètre nominal du filetage.16
Tableau 103 – Relations entre la masse, la hauteur et la section des conducteurs.20
Tableau 104 – Relations entre la force de traction et la section.20
Tableau AA.1 – Nombre de lots d’échantillons et séquences d’essai .38
Tableau BB.1 – Taille de fil, mm² vs. AWG.40
Tableau BB.2 – Capacité de connexion assignée et conducteurs raccordables .42
60998-2-3 © IEC:2002 – 3 –
CONTENTS
FOREWORD . 5
1 Scope. 9
2 Normative references . 9
3 Definitions . 9
4 General .11
5 General notes on tests .11
6 Main characteristics .11
7 Classification.11
8 Marking .13
9 Protection against electric shock .13
10 Connection of conductors.15
11 Construction.23
12 Resistance to ageing, to humid conditions, to ingress of solid foreign objects and to
harmful ingress of water .23
13 Insulation resistance and electric strength.25
14 Mechanical strength .25
15 Temperature rise and electrical performances .25
16 Resistance to heat .29
17 Clearances and creepage distances .29
18 Resistance of insulating material to abnormal heat and fire .31
19 Resistance of insulating material to tracking.31
20 EMC requirements.31
Annexes.37
Annex A A (normative) Number of sets of samples to be submitted to the tests.39
Annex B B (informative) Approximate relationship between conductors of cross-sectional
areas in mm² and American Wire Gauge (AWG) sizes as used in North America.41
Figure 101 – Test apparatus .31
Figure 102 – Example of test-points .33
Figure 103 – Example of ICPDs .35
Table 101 – Rated connecting capacity and connectable conductors.15
Table 102 – Nominal diameter of thread.17
Table 103 – Relationship between mass, height and cross-sectional area of conductors .21
Table 104 – Relationship between pull force and cross-sectional area .21
Table AA.1 – Number of sets of samples and test sequences.39
Table BB.1 – Wire size, mm² versus AWG.41
Table BB.2 – Rated connecting capacity and connectable conductors.43
– 4 – 60998-2-3 © CEI:2002
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
___________
DISPOSITIFS DE CONNEXION POUR CIRCUITS BASSE
TENSION POUR USAGE DOMESTIQUE ET ANALOGUE –
Partie 2-3: Règles particulières pour dispositifs de connexion
en tant que parties séparées avec organes de serrage
à perçage d'isolant
AVANT-PROPOS
1) La CEI (Commission Électrotechnique Internationale) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes
internationales. Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national
intéressé par le sujet traité peut participer. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement
avec l'Organisation Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les
deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, spécifications techniques, rapports techniques ou guides et agréés comme tels par les
Comités nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 60998-2-3 a été établie par le sous-comité 23F: Dispositifs de
connexion, du comité d'études 23 de la CEI: Petit appareillage.
Cette deuxième édition annule et remplace la première édition parue en 1991, dont elle
constitue une révision technique.
Le texte de cette norme est issu des documents suivants:
FDIS RVD
23F/144/FDIS 23F/150/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
Cette publication a été rédigée selon les Directives ISO/CEI, Partie 2.
60998-2-3 © IEC:2002 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
___________
CONNECTING DEVICES FOR LOW-VOLTAGE CIRCUITS
FOR HOUSEHOLD AND SIMILAR PURPOSES –
Part 2-3: Particular requirements for connecting
devices as separate entities with
insulation-piercing clamping units
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International
Organization for Standardization (ISO) in accordance with conditions determined by agreement between the
two organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60998-2-2 has been prepared by subcommittee 23F: Connecting
devices, of IEC technical committee 23: Electrical accessories.
This second edition cancels and replaces the first edition published in 1991, and constitutes
a technical revision.
The text of this standard is based on the following documents:
FDIS RVD
23F/144/FDIS 23F/150/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
– 6 – 60998-2-3 © CEI:2002
La présente norme constitue la Partie 2-3 de la série CEI 60998, publiée sous le titre général
Dispositifs de connexion pour circuits basse tension pour usage domestique et analogue.
Cette série se compose de la Partie 1, consacrée aux règles générales, et d’un certain
nombre de Parties 2, qui donnent les règles particulières.
Au moment de la publication de la présente partie, les parties suivantes sont déjà publiées:
Partie 1: Règles générales
Partie 2-1: Règles particulières pour dispositifs de connexion en tant que parties séparées
avec organes de serrage à vis
Partie 2-2: Règles particulières pour dispositifs de connexion en tant que parties séparées
avec organes de serrage sans vis
Partie 2-3: Règles particulières pour dispositifs de connexion en tant que parties séparées
avec organes de serrage à perçage d’isolant
Partie 2-4: Règles particulières pour dispositifs de connexion par épissure
Partie 2-5: Règles particulières pour les boîtes de connexion (jonction et/ou dérivation) pour
bornes ou dispositifs de connexion.
La présente Partie 2-3 est destinée à être utilisée conjointement avec la CEI 60998-1. Elle a
été établie sur la base de la deuxième édition (2002) de cette norme.
Elle complète et modifie les articles correspondants de la CEI 60998-1 de façon à la
transformer en norme CEI: Règles particulières pour dispositifs de connexion en tant que
parties séparées avec organes de serrage à perçage d’isolant.
Lorsqu'un paragraphe particulier de la Partie 1 n'est pas mentionné dans cette Partie 2-3, ce
paragraphe s'applique pour autant qu'il est raisonnable. Lorsque la présente norme spécifie
«addition», «modification» ou «remplacement», la prescription, la modalité d'essai ou le
commentaire correspondant de la Partie 1 doit être adapté en conséquence.
Dans la présente norme, les caractères d'imprimerie suivants sont employés:
• Prescriptions proprement dites: caractères romains.
• Modalités d'essais: caractères italiques.
• Commentaires: petits caractères romains.
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant 2010.
A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
Le contenu du corrigendum de novembre 2006 a été pris en considération dans cet
exemplaire.
60998-2-3 © IEC:2002 – 7 –
This standard constitutes Part 2-3 of the IEC 60998 series, published under the general title
Connecting devices for low voltage circuits for household and similar purposes. This series
consists of Part 1, devoted to general requirements, and various Parts 2, devoted to particular
requirements.
At the moment of the publication of this part, the following parts had already been published.
Part 1: General requirements
Part 2-1: Particular requirements for connecting devices as separate entities with screw-
type clamping units
Part 2-2: Particular requirements for connecting devices as separate entities with
screwless-type clamping units
Part 2-3: Particular requirements for connecting devices as separate entities with insulation
piercing clamping units
Part 2-4: Particular requirements for twist-on connecting devices
Part 2-5: Particular requirements for connecting boxes (junction and/or tapping) for
terminals or connecting devices
This Part 2-3 is intended to be used in conjunction with IEC 60998-1. It was established on
the basis of the second edition (2002) of that standard.
It supplements or modifies the corresponding clauses in IEC 60998-1, so as to convert that
publication into the IEC standard: Particular requirements for connecting devices as separate
entities with insulation piercing clamping units.
Where a particular subclause of Part 1 is not mentioned in this Part 2-2, that subclause
applies as far as is reasonable. Where this standard states “addition”, “modification” or
“replacement”, the relevant requirements, test specification or explanatory matter in Part 1
should be adapted accordingly.
In this standard, the following print types are used:
• requirements proper: in roman type.
• test specifications: in italic type.
• explanatory matter: in smaller roman type.
The committee has decided that the contents of this publication will remain unchanged until 2010.
At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
The contents of the corrigendum of November 2006 have been included in this copy.
– 8 – 60998-2-3 © CEI:2002
DISPOSITIFS DE CONNEXION POUR CIRCUITS BASSE
TENSION POUR USAGE DOMESTIQUE ET ANALOGUE –
Partie 2-3: Règles particulières pour dispositifs de connexion
en tant que parties séparées avec organes de serrage
à perçage d'isolant
1 Domaine d'application
L'article de la Partie 1 est applicable à l'exception de ce qui suit:
Addition:
Cette norme s'applique aux dispositifs de connexion avec organes de serrage à perçage
d'isolant principalement appropriés au raccordement de conducteurs isolés sans préparation.
Lors de l'opération de raccordement, l'isolation du conducteur est percée, transpercée,
découpée, enlevée, déplacée ou rendue inopérante d'une autre façon à l'endroit du ou des
points de contact.
NOTE Dans la suite du texte les dispositifs de connexion avec organes de serrage à perçage d'isolant sont
appelés DCPI (dispositifs de connexion à perçage d'isolant).
2 Références normatives
L'article de la Partie 1 est applicable à l'exception de ce qui suit:
Addition:
CEI 60227 (toutes les parties), Conducteurs et câbles isolés au polychlorure de vinyle, de
tension nominale au plus égale à 450/750 V
CEI 60245 (toutes les parties), Conducteurs et câbles isolés au caoutchouc
3 Définitions
L'article de la Partie 1 est applicable à l'exception de ce qui suit:
Définitions supplémentaires:
3.101
dispositifs de connexion à perçage d'isolant
DCPI
dispositif de connexion pour le raccordement et la déconnexion ultérieure éventuelle d'un
conducteur ou l'interconnexion de deux conducteurs ou plus, la connexion étant réalisée par
perçage, transpercement, découpage, enlèvement ou déplacement, ou en rendant inopérante
d'une autre façon l'isolation du ou des conducteurs sans dénudage préalable.
NOTE 1 L'enlèvement de la gaine du câble, si nécessaire, n'est pas considéré comme un dénudage préalable.
NOTE 2 Des exemples de DCPI sont donnés à la Figure 103.
60998-2-3 © IEC:2002 – 9 –
CONNECTING DEVICES FOR LOW-VOLTAGE CIRCUITS
FOR HOUSEHOLD AND SIMILAR PURPOSES –
Part 2-3: Particular requirements for connecting
devices as separate entities with
insulation-piercing clamping units
1 Scope
This clause of Part 1 is applicable except as follows:
Addition:
This standard applies to connecting devices with insulation piercing clamping units primarily
suitable for connecting insulated unprepared conductors.
In the connecting operation the insulation of the conductor is pierced, bored through, cut
through, removed, displaced or made ineffective in some other manner at the point or points
of contact.
NOTE In the text of this standard, connecting devices with insulation piercing clamping units are referred to
as IPCDs (insulation-piercing connecting devices).
2 Normative references
This clause of Part 1 is applicable except as follows:
Addition:
IEC 60227 (all parts), Polyvinyl chloride insulated cables of rated voltages up to and including
450/750 V
IEC 60245 (all parts), Rubber insulated cables
3 Definitions
This clause of Part 1 is applicable except as follows:
Additional definitions:
3.101
insulation-piercing connecting device
IPCD
connecting device for the connection and possible disconnection of one conductor or the
interconnection of two or more conductors, the connection being made by piercing, boring
through, cutting through, removing, displacing or making ineffective in some other manner the
insulation of the conductor(s) without previous stripping
NOTE 1 The removal of the sheath of the cable, if necessary, is not considered as a previous stripping.
NOTE 2 Examples of IPCDs are given in Figure 103.
– 10 – 60998-2-3 © CEI:2002
3.102
DCPI réutilisable
DCPI pouvant être utilisé plus d'une fois
3.103
DCPI non réutilisable
DCPI qui ne peut être utilisé qu'une fois
3.104
DCPI non démontable
DCPI ne pouvant être utilisé qu'une seule fois et dont l'enlèvement ne peut être fait qu'en
coupant le conducteur
4 Généralités
L'article de la Partie 1 est applicable.
5 Notes générales sur les essais
L'article de la Partie 1 est applicable à l'exception de ce qui suit:
5.3 Remplacement:
Les essais sont effectués dans l'ordre des séquences établies à l'annexe AA pour chaque lot.
5.4 Remplacement:
Le nombre d’échantillons neufs nécessaires pour les essais est réparti en lots dont le détail
est donné à l'annexe AA et la conformité à cette norme est établie si tous les essais sont
satisfaisants.
6 Caractéristiques principales
L'article de la Partie 1 est applicable.
7 Classification
L'article de la Partie 1 est applicable à l'exception de ce qui suit:
Paragraphes supplémentaires:
7.101 Classification selon la réutilisation et la démontabilité
– DCPI réutilisable;
– DCPI non réutilisable;
– DCPI non démontable.
7.102 Classification selon la méthode de raccordement
– avec un outil d'usage courant;
– avec un outil spécial;
– à la main.
60998-2-3 © IEC:2002 – 11 –
3.102
reusable IPCD
IPCD that can be used more than once
3.103
non reusable IPCD
IPCD that can be used only once
3.104
non-removable IPCD
PCD that can be used only once and can only be removed from the circuit by cutting the
conductors
4 General
This clause of Part 1 is applicable.
5 General notes on tests
This clause of Part 1 is applicable except as follows:
5.3 Replacement:
The tests are carried out in the sequence listed for each set in Annex AA.
5.4 Replacement:
The necessary number of new samples to be submitted to the tests is divided into sets as
detailed in annex AA and this standard is met if all tests are satisfied.
6 Main characteristics
This clause of Part 1 is applicable.
7 Classification
This clause of Part 1 is applicable except as follows:
Additional subclauses:
7.101 Classification according to reusability and removability
• reusable IPCD;
• non-reusable IPCD;
• non-removable IPCD.
7.102 Classification according to the method of making the connection
• with a general purpose tool;
• with a special tool;
• by hand.
– 12 – 60998-2-3 © CEI:2002
7.103 Classification selon le type de conducteur
– DCPI pour conducteurs massifs uniquement;
– DCPI pour conducteurs rigides (massifs ou câblés) uniquement;
– DCPI pour conducteurs souples uniquement;
– DCPI pour conducteurs rigides (massifs ou câblés) et souples.
7.104 Classification selon l'isolation du conducteur
– DCPI pour conducteurs conformes à la CEI 60227;
– DCPI pour conducteurs conformes à la CEI 60245;
– DCPI pour conducteurs spéciaux spécifiés par le constructeur.
7.105 Classification selon le nombre d'âmes du conducteur à raccorder
– DCPI pour conducteurs unitaires;
– DCPI pour câbles à plusieurs âmes.
8 Marquage
L'article de la Partie 1 est applicable à l'exception de ce qui suit:
Paragraphes supplémentaires:
8.101 Le plus petit emballage doit porter les indications suivantes:
– l'indication que le DCPI n'est pas réutilisable ou n'est pas démontable (7.101) (l'absence
d'indication signifie que le DCPI est réutilisable);
– la méthode de raccordement et de démontage si nécessaire (par exemple le couple de
serrage des vis s'il est plus élevé que celui indiqué au Tableau 102);
– les combinaisons sections-types de conducteurs, pour lesquels le DCPI est conçu selon
les classifications indiquées en 7.103, 7.104 et 7.105 (méthode de raccordement selon
7.102 si nécessaire).
Le constructeur doit décrire les types de câbles et d'isolations compatibles avec son
système si la pression de contact doit être transmise à travers l'isolation du conducteur.
8.102 Le DCPI classifié selon 7.103 doit être marqué de la façon suivante:
– bornes déclarées pour des conducteurs massifs avec la lettre «s» ou les lettres «sol»;
– bornes déclarées pour des conducteurs rigides avec la lettre «r»;
– bornes déclarées pour des conducteurs souples avec la lettre «f»;
– pas de marquage nécessaire pour les bornes déclarées pour des conducteurs rigides
(massifs et/ou câblés) et des conducteurs souples
Ce marquage doit être visible en un endroit approprié sur le produit final ou sur la plus petite
unité d'emballage ou dans la documentation technique et/ou les catalogues.
9 Protection contre les chocs électriques
L'article de la Partie 1 est applicable.
60998-2-3 © IEC:2002 – 13 –
7.103 Classification according to conductor type
• IPCDs for rigid solid conductors only;
• IPCDs for rigid (solid or stranded) conductors only;
• IPCDs for flexible conductors only;
• IPCDs for rigid (solid and/or stranded) and flexible conductors.
7.104 Classification according to conductor insulation
• IPCDs for conductors according to IEC 60227;
• IPCDs for conductors according to IEC 60245;
• IPCDs for special conductors specified by the manufacturer.
7.105 Classification according to the number of cores
in the conductor to be connected
• IPCDs for one core conductors;
• IPCDs for multicore cables or cords.
8 Marking
This clause of Part 1 is applicable except as follows:
Additional subclauses:
8.101 The following shall be indicated on the smallest package unit:
• if the IPCD is non-reusable or non-removable (7.101) (absence of marking indicates
the IPCD is reusable);
• the connection and disconnection procedure, if necessary (for example, screw torque
values if higher than stated in Table 102);
• the combinations of cross-sectional areas and types of conductors according to the
classification of 7.103, 7.104 and 7.105 for which the IPCD is designed (method of
connection according to 7.102 if necessary).
The manufacturer shall describe the types of cable and of insulation suitable for his system
if the contact pressure is being transmitted through this conductor insulation.
8.102 IPCDs classified according to 7.103 shall be marked as follows:
• terminals declared for solid conductors with the letter(s) “s” or “sol”;
• terminals declared for rigid conductors with the letter “r”;
• terminals declared for flexible conductors with the letter “f”.
• terminals declared for rigid (solid and/or stranded) and flexible conductors need not be
marked.
This marking shall appear where it is practical on the end product or on the smallest package
unit or in technical information and/or catalogues.
9 Protection against electric shock
This clause of Part 1 is applicable.
– 14 – 60998-2-3 © CEI:2002
10 Raccordement des conducteurs
L'article de la Partie 1 est applicable à l'exception de ce qui suit:
Paragraphes supplémentaires:
10.101 Un DCPI doit accepter un ou plusieurs conducteurs non préparés de mêmes sections
ou de sections différentes, rigides (massifs ou câblés) et souples, selon la déclaration du
constructeur.
10.102 La relation entre la capacité de connexion assignée de l'organe de serrage et les
conducteurs raccordables ainsi que les données sur les diamètres des conducteurs sont
indiquées au Tableau 101.
Tableau 101 – Capacité de connexion assignée et conducteurs raccordables
Conducteurs raccordables et leurs diamètres théoriques
Capacité de
Métriques
connexion
Rigides Souples
assignée
Massifs Câblés
mm² mm² ø mm ø mm mm² ø mm
0,2 0,2 0,51 0,53 0,2 0,61
0,34 0,34 0,63 0,66 0,34 0,8
0,5 0,5 0,9 1,1 0,5 1,1
0,75 0,75 1,0 1,2 0,75 1,3
1,0 1,0 1,2 1,4 1,0 1,5
1,5 1,5 1,5 1,7 1,5 1,8
a
2,5 2,5 1,9 2,2 2,5 2,3
a
4,0 4,0 2,4 2,7 4,0 2,9
a
6,0 6,0 2,9 3,3 4,0 2,9
10,0 10,0 3,7 4,2 6,0 3,9
16,0 16,0 4,6 5,3 10,0 5,1
25,0 25,0 – 6,6 16,0 6,3
35,0 35,0 – 7,9 25,0 7,8
NOTE 1 La correspondance pour les conducteurs AWG est donnée dans le Tableau BB.2 de
l’Annexe BB.
NOTE 2 Les diamètres des conducteurs rigides et souples les plus gros sont basés sur le
Tableau I de la CEI 60228 et de la CEI 60344 et pour les conducteurs AWG, sur les
Publications ASTM B172-71, ICEA S-19-81, ICEA S-66-524 et ICEA S-65-516.
a
Dimensions pour les conducteurs souples de classe 5 uniquement, conformes à la
CEI 60228A.
10.103 La déconnexion d'un conducteur d'un DCPI réutilisable ou non réutilisable doit
nécessiter une autre opération qu'une simple traction sur le conducteur uniquement. La
déconnexion doit impliquer une action délibérée à la main ou à l’aide d’un outil approprié.
La conformité est vérifiée par les essais décrits en 10.106 et 10.107.
10.104 Un DCPI doit être convenablement protégé contre les desserrages accidentels.
La conformité est vérifiée par examen et par les essais décrits en 10.106 et 10.107.
60998-2-3 © IEC:2002 – 15 –
10 Connection of conductors
This clause of Part 1 is applicable except as follows:
Additional subclauses:
10.101 An IPCD shall accept one or more unprepared conductors of the same or of different
nominal cross-sectional areas, rigid (solid or stranded) and flexible, as declared by the
manufacturer.
10.102 The relationship between the rated connecting capacity of clamping units and
connectable conductors as well as data on the diameters of conductors are given in
Table 101.
Table 101 – Rated connecting capacity and connectable conductors
Connectable conductors and their theoretical diameters
Rated
Metric
connecting
Rigid Flexible
capacity
Solid Stranded
mm² mm² ø mm ø mm mm² ø mm
0,2 0,2 0,51 0,53 0,2 0,61
0,34 0,34 0,63 0,66 0,34 0,8
0,5 0,5 0,9 1,1 0,5 1,1
0,75 0,75 1,0 1,2 0,75 1,3
1,0 1,0 1,2 1,4 1,0 1,5
1,5 1,5 1,5 1,7 1,5 1,8
a
2,5 2,5 1,9 2,2 2,5 2,3
a
4,0 4,0 2,4 2,7 4,0 2,9
a
6,0 6,0 2,9 3,3 4,0 2,9
10,0 10,0 3,7 4,2 6,0 3,9
16,0 16,0 4,6 5,3 10,0 5,1
25,0 25,0 - 6,6 16,0 6,3
35,0 35,0 - 7,9 25,0 7,8
NOTE 1 Correspondence with AWG is given in Table BB.2 in Annex BB.
NOTE 2 Diameters of the largest rigid and flexible conductors are based on Table 1 of
IEC 60228 and IEC 60344 and for AWG conductors, on ASTM B172-71, ICEA Publication
S-19-81, ICEA Publication S-66-524 and ICEA Publication S-65-516.
a
Dimensions for Class 5 flexible conductors only, according to IEC 60228A.
10.103 The disconnection of a conductor from a reusable or non-reusable IPCD shall require
an operation other than a pull on the conductor only. It shall be necessary to take deliberate
action to disconnect it by hand or with a suitable tool.
Compliance is checked by the tests of 10.106 and 10.107.
10.104 An IPCD shall be adequately locked against unintended loosening.
Compliance is checked by inspection and by the tests of 10.106 and 10.107.
– 16 – 60998-2-3 © CEI:2002
10.105 Si un DCPI comporte des vis pour le raccordement des conducteurs, l’essai suivant
doit être effectué avant chaque essai:
Les vis des DCPI réutilisables sont serrées et desserrées cinq fois au moyen d'un outil
approprié exerçant le couple indiqué dans la colonne correspondante du Tableau 102. Une
extrémité de conducteur neuve est utilisée après chaque desserrage de la vis.
Les vis des DCPI non réutilisables et non démontables sont serrées une fois au couple
indiqué dans la colonne appropriée du Tableau 102.
Des valeurs de couples plus élevées peuvent être utilisées sur recommandation du
constructeur du DCPI lorsque les informations correspondantes sont fournies.
Tableau 102 – Diamètre nominal du filetage
Couple
Nm
Diamètre nominal
II
V
I
du filetage III
IV
mm
Inférieur
Supé-
ou égal à
rieur à
0,1 0,1 –
– 1,6 0,05 –
1,6 2,0 0,1 – 0,2 0,2 –
2,0 2,8 0,2 – 0,4 0,4 –
2,8 3,0 0,25 – 0,5 0,5 –
3,0 3,2 0,3 – 0,6 0,6 –
3,2 3,6 0,4 – 0,8 0,8 –
3,6 4,1 0,7 1,2 1,2 1,2 1,2
4,1 4,7 0,8 1,2 1,8 1,8 1,8
4,7 5,3 0,8 1,4 2,0 2,0 2,0
5,3 6,0 1,2 1,8 2,5 3,0 3,0
6,0 8,0 2,5 2,5 3,5 6,0 4,0
8,0 10,0 – 3,5 4,0 10,0 6,0
10,0 12,0 – 4,0 – – 8,0
12,0 15,0 – 5,0 – – 10,0
La colonne I s'applique aux vis sans tête si la vis ne dépasse pas du trou lorsqu'elle est serrée et aux
autres vis qui ne peuvent pas être serrées au moyen d'un tournevis dont la lame est plus large que le
diamètre de la vis.
La colonne II s'applique aux vis qui peuvent être serrées au moyen d'un tournevis dont la lame est
plus large que le diamètre de la vis.
La colonne III s'applique aux vis qui sont serrées par d'autres moyens qu'un tournevis.
La colonne IV s'applique aux vis et aux écrous, autres que les écrous des organes de serrage à capot
taraudé, qui sont serrés par d'autres moyens qu'un tournevis.
La colonne V s'applique aux écrous des organes de serrage à capot taraudé qui sont serrés par
d'autres moyens qu'un tournevis.
60998-2-3 © IEC:2002 – 17 –
10.105 If an IPCD uses screws for wire connection, the following test shall be performed
before each test:
Screws of reusable IPCDs are tightened and loosened 5 times by means of an appropriate
tool applying the torque as stated in the corresponding column of Table 102. A new conductor
end is used each time the screw is loosened and subsequently re-tightened.
Screws of non-reusable and non-removable IPCDs are tightened once with the torque as
stated in the appropriate column of Table 102.
Higher values of torque may be used if so stated by the manufacturer of the IPCD, when the
relevant information is provided.
Table 102 – Nominal diameter of thread
Torque Nm
Nominal diameter
II
V
I
of thread III
IV
mm
Up to
Over and
including
0,1 0,1 –
– 1,6 0,05 –
1,6 2,0 0,1 – 0,2 0,2 –
2,0 2,8 0,2 – 0,4 0,4 –
2,8 3,0 0,25 – 0,5 0,5 –
3,0 3,2 0,3 – 0,6 0,6 –
3,2 3,6 0,4 – 0,8 0,8 –
3,6 4,1 0,7 1,2 1,2 1,2 1,2
4,1 4,7 0,8 1,2 1,8 1,8 1,8
4,7 5,3 0,8 1,4 2,0 2,0 2,0
5,3 6,0 1,2 1,8 2,5 3,0 3,0
6,0 8,0 2,5 2,5 3,5 6,0 4,0
8,0 10,0 – 3,5 4,0 10,0 6,0
10,0 12,0 – 4,0 – – 8,0
12,0 15,0 – 5,0 – – 10,0
Column I applies to screws without heads if the screw, when tightened, does not protrude from the
hole, and to other screws which cannot be tightened by means of a screwdriver with a blade wider
than the diameter of the screw.
Column II applies to screws which can be tightened by means of a screwdriver with a blade wider
than the diameter of the screw.
Column III applies to screws which are tightened by means other than a screwdriver.
Column IV applies to screws and nuts, other than nuts of mantle clamping units, which are tightened
by means other than a screwdriver.
Column V applies to nuts of mantle clamping units, which are tightened by means other than a
screwdriver.
– 18 – 60998-2-3 © CEI:2002
Pendant l'essai, un DCPI réutilisable ne doit pas subir de dommages le rendant inutilisable
pour un usage ultérieur tels que rupture des vis, détérioration des fentes des têtes, des
filetages, des rondelles ou des étriers.
La forme de la lame du tournevis d'essai doit correspondre à la tête de la vis à essayer. Les
vis doivent être serrées en appliquant le couple en une seule fois de façon continue et sans
à-coups.
10.106 Les DCPI à l'état neuf sont équipés de conducteurs unitaires des sections minimale
et maximale et du type déclarés par le constructeur et sont essayés dans l'appareil indiqué à
la Figure 101.
L'essai doit être effectué sur six échantillons: trois avec le conducteur de la section la plus
petite et trois avec le conducteur de la plus grosse section.
La longueur du con
...










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...