Abstract

IEC 60730-2-24:2026 applies to automatic displacement electrical controls
- for use in, on, or in association with appliances for household and similar use;
NOTE 1 Through this document, the word "control" means "displacement electrical control".
EXAMPLE 1 Displacement electrical controls used in electrical pressure cookers with gross volume up to 25 l, with working pressure over 4 kPa and less than 150 kPa.
- that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC;
- used in, on, or in association with equipment that use electricity;
- that are mechanically or electrically operated, responsive to change of position of point of action.
NOTE 2 Requirements for manual switches not forming part of an automatic control are covered in IEC 61058‑1‑1.
This document applies to
- inherent safety of automatic electro-mechanical displacement electrical controls;
- functional safety of automatic electro-mechanical displacement electrical controls;
- the operating values, operating times, and operating sequences where such are associated with equipment safety;
- displacement electrical controls having temperature sensing element(s), in which cases additional requirements can be considered to be necessary. Requirements for temperature sensing controls are included in IEC 60730-2-9.
This document specifies the requirements for construction, operation and testing of automatic displacement electrical controls used in, on, or in association with equipment.
This document does not
- apply to automatic electronic controls;
- take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer applies.
NOTE 3 For more information about guidance to the application of displacement electrical controls, see Annex AA.
This part 2-24 is intended to be used in conjunction with IEC 60730-1. It was established on the basis of the sixth edition of that standard (2022). Consideration may be given to future editions of, or amendments to, IEC 60730‑1. This part 2-24 supplements or modifies the corresponding clauses in IEC 60730-1, so as to convert that publication into the IEC standard: Particular requirements for displacement electrical controls. Where this part 2-24 states "addition", "modification" or "replacement", the relevant require­ment, test specification or explanatory matter in Part 1 should be adapted accordingly. Where no change is necessary, part 2-24 indicates that the relevant clause or subclause applies.

Status
Published
Publication Date
26-May-2026
Current Stage
PPUB - Publication issued - 60 Publication
Start Date
27-May-2026
Due Date
08-May-2026
Completion Date
08-May-2026

Buy Documents

Standard

IEC 60730-2-24:2026 - Automatic electrical controls - Part 2-24: Particular requirements for displacement electrical controls

ISBN:978-2-8327-1192-7
Release Date:27-May-2026
English language (23 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

IEC 60730-2-24:2026 EXV - Automatic electrical controls - Part 2-24: Particular requirements for displacement electrical controls

ISBN:978-2-8327-1274-0
Release Date:27-May-2026
English language (295 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

IEC 60730-2-24:2026 - Dispositifs de commande électrique automatiques - Partie 2-24: Exigences particulieres pour les dispositifs de commande électriques de déplacement

ISBN:978-2-8327-1192-7
Release Date:27-May-2026
French language (23 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

iec60730-2-24{ed1.0}en - IEC 60730-2-24:2026 - Automatic electrical controls - Part 2-24: Particular requirements for displacement electrical controls

ISBN:978-2-8327-1192-7
Release Date:27-May-2026
English and French language (46 pages)
sale 15% off
Preview
sale 15% off
Preview

IEC 60730-2-24:2026 is an IEC International Standard for automatic displacement electrical controls used in, on, or in association with household and similar appliances and other equipment that use electricity. It specifies construction, operation, and test requirements for AC or DC controls that respond to movement of the point of action, and it is intended to be used with IEC 60730-1:2022.

What does IEC 60730-2-24:2026 specify?

IEC 60730-2-24:2026 sets particular requirements for automatic displacement electrical controls, which this document simply calls “control”. The standard covers electro-mechanical controls, their inherent safety, their functional safety, and the operating values, operating times, and operating sequences that matter for equipment safety.

The scope includes controls with a rated voltage up to 690 V AC or 600 V DC, and it includes controls for appliances for household and similar use. An example given in the scope is a displacement electrical control used in an electrical pressure cooker.

IEC 60730-2-24:2026 does not apply to automatic electronic controls. It also excludes manual switches that are not part of an automatic control, which are covered by IEC 61058-1-1.

The document is organized into clauses 1 to 26, starting with scope, normative references, and terms and definitions, then moving through general requirements, marking and technical information, safety construction, insulation coordination, component requirements, testing, endurance, mechanical strength, heat/fire/tracking, EMC, and abnormal operation. It also includes annexes that add guidance or specialized requirements for markings, pollution, glow-wire and tracking tests, software, DC supply cases, thermistors, SELV/PELV, test source impedances, and application guidance.

AnnexWhat it covers
AIndelibility of markings
FPollution and pollution degree in the micro-environment
GGlow-wire test, proof tracking test, and ball pressure test
HSoftware-related requirements, including fault control and functional safety
IDC supplied controls for non-stationary applications
JThermistors and controls using thermistors
NDifferent source impedances, test application, and installation classification
PSELV and PELV requirements
AAGuidance for applying displacement electrical controls

What are the key requirements of IEC 60730-2-24:2026?

IEC 60730-2-24:2026 combines marking, construction, insulation, component, and test requirements so that a displacement electrical control can be specified and verified as a safety-related part of equipment. In practice, it tells designers what must be declared, how the control must be built, and how it is checked in testing.

Identification, marking, and test information

Clause 5 requires the manufacturer to provide technical information by marking, documentation, or declaration, depending on the item. The information includes the manufacturer identity, type reference, rated voltage and supply nature, purpose of the control, construction type, load type, enclosure protection, terminal identification, mounting method, earthing method, operating values, ageing period, pollution degree, battery details, and other declared limits.

This matters because the control cannot be assessed correctly unless the user, lab, or certifier knows how it is intended to be installed and operated. Table 1 is the central declaration list used to decide what must appear on the product or in the documentation.

Clause 5.3 limits the Class II symbol to Class II controls, and Clause 5.4 gives specific marking expectations for terminals, installation, servicing, batteries, and special conductors. Clause A covers how markings are checked for indelibility.

Protection against electric shock, earthing, and terminals

Clauses 6 and 7 require adequate protection against accidental contact with live parts, including rules for actuating members, covers, capacitors, and battery-operated controls with a user-accessible mains input. Accessible conductive parts in Class I controls must be properly earthed, and Class II and Class III constructions have their own protection rules.

Clauses 8 and 10 cover terminals, terminations, threaded parts, and current-carrying connections. The control must clamp conductors reliably, maintain continuity, withstand normal use, and keep connection integrity under mounting or servicing.

In practice, these clauses determine how wiring is landed, which conductor types are permitted, how earthing is identified, and what mechanical robustness is needed at terminals. That is important for installers and for product safety reviews.

Construction, actions, software, and protective functions

Clause 9 covers the control’s physical construction, actuation, mounting, cord attachment, openings, servicing, software, and protective control functions. It includes requirements for controls using software, remotely actuated control functions, remote reset action, and smart enabled controls with external communication.

The standard also distinguishes action types such as full disconnection, micro-disconnection, micro-interruption, trip-free mechanisms, reset-by-tool actions, ageing-dependent actions, and electronic disconnection on operation. Those action types matter because the intended safety behavior must be declared and then tested against the right operating mode.

For controls using software, Annex H expands on architecture, fault/error control, error avoidance, memory tests, access to data exchange, and functional safety. This is the part that helps engineers decide what software measures and diagnostics are needed when the control is not purely electromechanical.

Insulation, components, and fault assessment

Clause 11 sets requirements for creepage distances, clearances, and distances through solid insulation. It ties the design to voltage, material group, pollution degree, and rated impulse voltage, and it says creepage distance must not be less than the associated clearance.

Clauses 12 and 13 cover components and fault assessment on electronic circuits. Transformers, switch mode power supplies, capacitors, fuses, varistors, thermistors, relays, and other components are checked in the context of safety, and the electronic circuit must be assessed for inherent safety and functional safety.

For design work, this means the control cannot be treated as a generic electronic assembly. The component choices and failure analysis must support the safety function, especially where a fault could create overheating, unsafe disconnection behavior, or loss of protective action.

Environmental, endurance, mechanical, and EMC tests

Clauses 14 to 16 cover moisture and dust resistance, humid conditions, touch current, insulation resistance, electric strength, and heating. Clause 17 addresses manufacturing deviation and drift for type 2 actions, and Clause 18 covers transportation, storage, and temperature stress.

Clauses 19 to 22 test endurance, mechanical strength, heat/fire/tracking resistance, and corrosion resistance. Clause 19 is especially important for repeated operation because it applies electrical, thermal, and mechanical cycling, including special tests for automatic actions and remote reset functions.

Clauses 23 to 25 cover electromagnetic compatibility (EMC) emission and immunity, including conducted and radiated emission, surge, electrical fast transient, radio-frequency electromagnetic field, electrostatic discharge, power-frequency magnetic fields, and voltage dips and interruptions. Clause 26 adds abnormal operation tests such as blocked output, overload, and battery short-circuit conditions.

For manufacturers and test labs, these clauses define the test plan that proves the control survives normal service and foreseeable faults. For buyers, they indicate whether a control has been checked for the conditions that usually drive field failures.

What terms does IEC 60730-2-24:2026 define?

IEC 60730-2-24:2026 defines the vocabulary needed to specify displacement electrical controls consistently. The terms below are central to the standard.

  • Displacement electrical control - a control responsive to a change of position of the point of action, which is the control type covered by this part.
  • Type 2 action - an action class used where the operating value, operating time, or operating sequence is part of the safety function and must be assessed for deviation and drift.
  • Full disconnection - an action that opens the circuit completely when operated.
  • Micro-disconnection - an action that separates contacts by a smaller, defined disconnection behavior used where the safety function permits it.
  • Safety extra-low voltage (SELV) - a low-voltage circuit designed so that protection against electric shock is provided by the circuit arrangement itself.
  • Protective extra-low voltage (PELV) - a low-voltage circuit with protective arrangements that differ from SELV but still address electric shock protection.
  • Smart enabled control - a control with external communication features that must still preserve its protective functions.
  • Functional safety - the part of safety that depends on the correct response of the control and its related protective behavior.

Who uses IEC 60730-2-24:2026?

IEC 60730-2-24:2026 is used by control designers, appliance manufacturers, test laboratories, certification bodies, quality managers, and procurement teams working with household and similar electrical equipment. It is especially relevant where the control is electro-mechanical, software-assisted, remotely resettable, or part of a protective function.

Engineers use it to choose the control type, define mounting and wiring, and set the required operating behavior. Quality and compliance teams use it to plan marking checks, type testing, endurance testing, and EMC verification. Buyers use it to judge whether a control is the right safety standard for the application they are sourcing.

Which standards are used with IEC 60730-2-24:2026?

IEC 60730-2-24:2026 is built on IEC 60730-1:2022 and refers to a set of IEC, CISPR, and related standards for general safety, insulation coordination, components, wiring, and EMC testing.

  • IEC 60730-1:2022 - the base general requirements that this part supplements and modifies.
  • IEC 61058-1-1 - manual switches not forming part of an automatic control.
  • IEC 60730-2-9 - temperature sensing controls.
  • IEC 60038, IEC 60085, IEC 60068-2-75, IEC 60099-1:1991 - standard voltages, insulation thermal classification, hammer testing, and surge arrester-related information.
  • IEC 60112:2020, IEC 60127 (all parts), IEC 60269 (all parts), IEC 60227-1, IEC 60245-1 - tracking index testing, fuses, and cable requirements.
  • IEC 60335-1:2020, IEC 60384-14 - household appliance safety context and capacitor requirements.
  • IEC 60664-1, IEC 60664-4 - insulation coordination, clearance, creepage, and impulse-voltage guidance.
  • IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-4-20, IEC 61000-4-21, IEC 61000-4-22, CISPR 14-1, CISPR 32, IEC 61000-6-3, IEC 61000-6-4 - EMC immunity and emission test methods and limits.
  • IEC 61051-1, IEC 61051-2 - varistor requirements.

What does the IEC 60730-2-24:2026 document contain?

IEC 60730-2-24:2026 contains detailed marking rules, definitions, constructional requirements, and a large test programme rather than a short performance description. It includes tables for technical declarations, insulation values, EMC limits, and operating conditions, plus figures for travel distances, test fixtures, and measurement setups.

The document also includes test procedures for marking indelibility, creepage and clearance measurements, touch current, electric strength, heating, endurance, mechanical strength, glow-wire, proof tracking, ball pressure, and abnormal operation. Those procedures are what laboratories follow when they verify a control for design approval, certification, or type testing.

Figures 101 to 103 describe the displacement positions, travel distances, and an example test fixture for displacement electrical controls. Annex H, Annex I, and Annex J add specialized content for software, non-stationary DC supply cases, and thermistor-based controls, so the standard can be applied to a wide range of control designs without changing its core safety model.

Buy Documents

Standard

IEC 60730-2-24:2026 - Automatic electrical controls - Part 2-24: Particular requirements for displacement electrical controls

ISBN:978-2-8327-1192-7
Release Date:27-May-2026
English language (23 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

IEC 60730-2-24:2026 EXV - Automatic electrical controls - Part 2-24: Particular requirements for displacement electrical controls

ISBN:978-2-8327-1274-0
Release Date:27-May-2026
English language (295 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

IEC 60730-2-24:2026 - Dispositifs de commande électrique automatiques - Partie 2-24: Exigences particulieres pour les dispositifs de commande électriques de déplacement

ISBN:978-2-8327-1192-7
Release Date:27-May-2026
French language (23 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

iec60730-2-24{ed1.0}en - IEC 60730-2-24:2026 - Automatic electrical controls - Part 2-24: Particular requirements for displacement electrical controls

ISBN:978-2-8327-1192-7
Release Date:27-May-2026
English and French language (46 pages)
sale 15% off
Preview
sale 15% off
Preview

Frequently Asked Questions

IEC 60730-2-24:2026 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Automatic electrical controls - Part 2-24: Particular requirements for displacement electrical controls". This standard covers: IEC 60730-2-24:2026 applies to automatic displacement electrical controls - for use in, on, or in association with appliances for household and similar use; NOTE 1 Through this document, the word "control" means "displacement electrical control". EXAMPLE 1 Displacement electrical controls used in electrical pressure cookers with gross volume up to 25 l, with working pressure over 4 kPa and less than 150 kPa. - that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC; - used in, on, or in association with equipment that use electricity; - that are mechanically or electrically operated, responsive to change of position of point of action. NOTE 2 Requirements for manual switches not forming part of an automatic control are covered in IEC 61058‑1‑1. This document applies to - inherent safety of automatic electro-mechanical displacement electrical controls; - functional safety of automatic electro-mechanical displacement electrical controls; - the operating values, operating times, and operating sequences where such are associated with equipment safety; - displacement electrical controls having temperature sensing element(s), in which cases additional requirements can be considered to be necessary. Requirements for temperature sensing controls are included in IEC 60730-2-9. This document specifies the requirements for construction, operation and testing of automatic displacement electrical controls used in, on, or in association with equipment. This document does not - apply to automatic electronic controls; - take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer applies. NOTE 3 For more information about guidance to the application of displacement electrical controls, see Annex AA. This part 2-24 is intended to be used in conjunction with IEC 60730-1. It was established on the basis of the sixth edition of that standard (2022). Consideration may be given to future editions of, or amendments to, IEC 60730‑1. This part 2-24 supplements or modifies the corresponding clauses in IEC 60730-1, so as to convert that publication into the IEC standard: Particular requirements for displacement electrical controls. Where this part 2-24 states "addition", "modification" or "replacement", the relevant require­ment, test specification or explanatory matter in Part 1 should be adapted accordingly. Where no change is necessary, part 2-24 indicates that the relevant clause or subclause applies.

IEC 60730-2-24:2026 applies to automatic displacement electrical controls - for use in, on, or in association with appliances for household and similar use; NOTE 1 Through this document, the word "control" means "displacement electrical control". EXAMPLE 1 Displacement electrical controls used in electrical pressure cookers with gross volume up to 25 l, with working pressure over 4 kPa and less than 150 kPa. - that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC; - used in, on, or in association with equipment that use electricity; - that are mechanically or electrically operated, responsive to change of position of point of action. NOTE 2 Requirements for manual switches not forming part of an automatic control are covered in IEC 61058‑1‑1. This document applies to - inherent safety of automatic electro-mechanical displacement electrical controls; - functional safety of automatic electro-mechanical displacement electrical controls; - the operating values, operating times, and operating sequences where such are associated with equipment safety; - displacement electrical controls having temperature sensing element(s), in which cases additional requirements can be considered to be necessary. Requirements for temperature sensing controls are included in IEC 60730-2-9. This document specifies the requirements for construction, operation and testing of automatic displacement electrical controls used in, on, or in association with equipment. This document does not - apply to automatic electronic controls; - take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer applies. NOTE 3 For more information about guidance to the application of displacement electrical controls, see Annex AA. This part 2-24 is intended to be used in conjunction with IEC 60730-1. It was established on the basis of the sixth edition of that standard (2022). Consideration may be given to future editions of, or amendments to, IEC 60730‑1. This part 2-24 supplements or modifies the corresponding clauses in IEC 60730-1, so as to convert that publication into the IEC standard: Particular requirements for displacement electrical controls. Where this part 2-24 states "addition", "modification" or "replacement", the relevant require­ment, test specification or explanatory matter in Part 1 should be adapted accordingly. Where no change is necessary, part 2-24 indicates that the relevant clause or subclause applies.

IEC 60730-2-24:2026 is classified under the following ICS (International Classification for Standards) categories: 97.120 - Automatic controls for household use. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 60730-2-24:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.2 Definitions of types of control according to purpose
  • 3.4 Definitions relating to disconnection and interruption
  • 3.8 Definitions relating to component parts of controls
  • 3.8.3 actuating member
  • 4 General
  • 5 Required technical information
  • 6 Purpose of control D or E
  • 16 Temperature limits of mounting surfaces (T ) 16.5, C
  • 19.3.1 Maximum temperature of mounting surface (T ) if it is more than
  • 20 K above T
  • 18 Not applicable
  • 19 Not applicable
  • 33 Type 2 action 3.4.106 D or E
  • 9.4.3 H.17
  • 43 Not applicable
  • 48 Not applicable
  • 50 Not applicable
  • 51 Not applicable
  • 52 Not applicable
  • 53 Not applicable
  • 54 Not applicable
  • 56 Not applicable
  • 60 Not applicable
  • 61 Not applicable
  • 62 Not applicable
  • 65 Not applicable
  • 66 Not applicable
  • 75 Not applicable
  • 76 Not applicable
  • 77 Not applicable
  • 78 Not applicable
  • 79 Not applicable
  • 80 Not applicable
  • 81 Not applicable
  • 82 Not applicable
  • 83 Not applicable
  • 84 Not applicable
  • 86 Not applicable
  • 6 Protection against electric shock
  • 7 Provision for protective earthing
  • 8 Terminals and terminations
  • 9 Constructional requirements
  • 10 Threaded parts and connections
  • 11 Creepage distances, clearances and distances through solid insulation
  • 12 Components
  • 13 Fault assessment on electronic circuits
  • 14 Moisture and dust resistance
  • 15 Electric strength and insulation resistance
  • 16 Heating
  • 17 Manufacturing deviation and drift
  • 18 Environmental stress
  • 19 Endurance
  • 19.1 General requirements
  • 19.3 Thermal conditions for the tests
  • 19.4 Manual and mechanical conditions for the tests
  • 19.14 Evaluation of compliance
  • 19.15 Test for particular purpose controls
  • 20 Mechanical strength
  • 20.2 Impact resistance
  • 20.3 Free-standing controls
  • 20.4 In-line cord controls
  • 20.5 Pull-cord actuated controls
  • 20.6 Foot actuated controls
  • 20.8 Flexing – test
  • 20.9 Cord anchorages – test
  • 21 Resistance to heat, fire and tracking
  • 22 Resistance to corrosion
  • 23 Electromagnetic compatibility (EMC) requirements – Emission
  • 24 Normal operation
  • 25 Electromagnetic compatibility (EMC) requirements – Immunity
  • 26 Abnormal operation tests
  • Annex H
  • Annex AA
  • Bibliography

1 Scope

This clause of Part 1 is replaced by the following:

This part of IEC 60730 applies to automatic displacement electrical controls - for use in, on, or in association with appliances for household and similar use; NOTE 1 Through this document, the word "control" means "displacement electrical control". EXAMPLE 1 Displacement electrical controls used in electrical pressure cookers with gross volume up to 25 l, with working pressure over 4 kPa and less than 150 kPa.

  • that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC;
  • used in, on, or in association with equipment that use electricity;
  • that are mechanically or electrically operated, responsive to change of position of point of action.

NOTE 2 Requirements for manual switches not forming part of an automatic control are covered in IEC 61058-1-1. This document applies to - inherent safety of automatic electro-mechanical displacement electrical controls; - functional safety of automatic electro-mechanical displacement electrical controls; - the operating values, operating times, and operating sequences where such are associated with equipment safety; - displacement electrical controls having temperature sensing element(s), in which cases additional requirements can be considered to be necessary. Requirements for temperature sensing controls are included in IEC 60730-2-9.

This document specifies the requirements for construction, operation and testing of automatic displacement electrical controls used in, on, or in association with equipment. This document does not - apply to automatic electronic controls; - take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer applies.

NOTE 3 For more information about guidance to the application of displacement electrical controls, see Annex AA.

2 Normative references

This clause of Part 1 is applicable.

3 Terms and definitions

This clause of Part 1 is applicable except as follows:

3.2 Definitions of types of control according to purpose

Additional definitions:

3.2.101 displacement electrical control automatic control where the displacement of point of action occurs through the displacement of the container due to pressure change Note 1 to entry: The container is an inner pot in the case of rice cooker. Note 2 to entry: The displacement electrical control is considered an operating control with a type 2 action and normally a protective control is provided on the end product to prevent a hazard, therefore there is no need to verify the robustness of the self-locking mechanism.

3.2.102 position limiter displacement electrical control which is intended to keep a position below one particular value during normal operating conditions and which may have provision for setting by the endproduct manufacturer Note 1 to entry: A position limiter can be manual reset type.

3.2.103 position regulator cycling displacement electrical control, which is intended to keep a position between two particular values under normal operating conditions and which may have provision for setting by the end-product manufacturer

3.4 Definitions relating to disconnection and interruption

Additional definitions:

3.4.101 free position P f initial state of the point of action of the displacement electrical control Note 1 to entry: P is indicated as the position of 0 displacement in Figure 101. f Note 2 to entry: In general, free position is at located position. 3.4.102 disconnection position P d position where the contact is disconnected from the circuit by the action mechanism under the external force Note 1 to entry: P is indicated in Figure 101.

d 3.4.103 self-locking position P s position in which the self-locking mechanism just operates while the displacement can continue to increase when the contact is disconnected

3.4.104 limit position P

farthest position of the action mechanism of the displacement electrical control that can be reached under external force where the action mechanism can recover to the free position when the external force is released Note 1 to entry: P is indicated in Figure 101.

3.4.105 reset position P r position of the action mechanism where the disconnected contact will be re-connected when the displacement is reduced Note 1 to entry: P is indicated in Figure 101.

r 3.4.106 disconnection travel distance distance between free position and disconnection position 3.4.107 self-locking travel distance distance between disconnection position and self-locking position 3.4.108 limit travel distance distance between free position and limit position 3.4.109 reset travel distance distance between free position and reset position 3.4.110 point of action point on the displacement electrical control at which the displacement is made

3.8 Definitions relating to component parts of controls

3.8.3 actuating member

Additional note:

Note 101 to entry: In Clause 19 of this document, the term "actuating member" includes that part which is mechanically moved, pulled, pushed or turned to cause initiation of a control action.

4 General

This clause of Part 1 is applicable except as follows:

4.3.4.5.1 Additional paragraph:

For the displacement electrical controls designed with two or more sensing positions for multiple functions, the relevant tests shall be applied to the individual sensing position, one at a time.

5 Required technical information

This clause of Part 1 is applicable except as follows:

Table 1 – Required technical information and methods of providing these information Information Clause or subclause Method Modifications:

3.2, 4.3.4.2, 4.3.4.5,

6 Purpose of control D or E

19.15, 3.2.101, 3.2.102

16 Temperature limits of mounting surfaces (T ) 16.5, C

s

19.3.1 Maximum temperature of mounting surface (T ) if it is more than

smax

20 K above T

19.15.101 max 19.15.102 NOTE 1 If the displacement electrical control is intended for installation mode 2, the temperature of mounting post as shown in AA.1 Figure AA.2 is taken as T .

s

18 Not applicable

19 Not applicable

20 Number of automatic cycles (A) for each automatic action. 13.1.3.3, - Minimum 6 000 cycles for disconnection action Table 14, - Minimum 30 cycles for self-locking mechanmism 19.7.6, 19.8.4, NOTE 2 For controls having more than one automatic action, a different value can be declared for each.

19.15.101

33 Type 2 action 3.4.106 D or E

9.4.3 H.17

43 Not applicable

48 Not applicable

50 Not applicable

51 Not applicable

52 Not applicable

53 Not applicable

54 Not applicable

56 Not applicable

60 Not applicable

61 Not applicable

62 Not applicable

65 Not applicable

66 Not applicable

75 Not applicable

76 Not applicable

77 Not applicable

78 Not applicable

79 Not applicable

80 Not applicable

81 Not applicable

Information Clause or subclause Method

82 Not applicable

83 Not applicable

84 Not applicable

86 Not applicable

Additional items:

101 Free position (P ) 3.4.101, f 9.1.4, D or E Figure 101, H.17.5.1

102 3.4.106, Disconnection travel distance 9.4.3, D or E Figure 101, Figure 102 103 Self-locking travel distance 3.4.107, 19.15.102, D or E Figure 101 104 Limit travel distance 3.4.108, 19.15.101, D or E Figure 101

105 3.4.109, Reset travel distance D or E Figure 101

Procedures of limit travel distance endurance test 19.15 X 107 Operation speed of the operation mechanism used for accelerated 19.15 X speed testing during the endurance test 108 Maximum hold on time of the limit travel distance 19.15 X 109 End product manufacturer's responsibility AA.1 D or E 110 Maximum ambient temperature of the displacement electrical AA.4.2 D or E control 111 Limit of force applicable to the displacement electrical control 9.4.3 X d Not applicable e Not applicable g Not applicable k Not applicable Additional notes:

The disconnection travel distance is set according to the requirements of users.

The reset travel distance is set according to the requirements of users.

It includes the number of cycles for limit travel distance test. The number of cycles for disconnection position action and self-locking position action are identified in requirement 20.

6 Protection against electric shock

This clause of Part 1 is applicable.

7 Provision for protective earthing

This clause of Part 1 is applicable.

8 Terminals and terminations

This clause of Part 1 is applicable.

9 Constructional requirements

This clause of Part 1 is applicable except as follows.

9.3.4 Setting by the manufacturer

Additional note:

NOTE 101 The method that a screw is sealed permanently by gluing or similar means is considered as acceptable. Additional subclause:

9.3.101 Displacement electrical controls with integrated protective function The displacement electrical control with integrated protective function shall be evaluated as a protective control. The position limiter contains protective functions. For the position limiter, once the displacement of the point of action reaches the self-locking travel distance, it shall not be reconnected, even if the applied external force decreases or disappears, unless it is reset manually.

Compliance is checked by the following test.

...

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 Definitions relating to ratings, voltages, currents, frequencies, and wattages
  • 3.1.1 rated voltage, current, frequency or wattage
  • 3.1.2 rated voltage, current, frequency or wattage range
  • 3.1.3 working voltage
  • 3.1.4 extra-low voltage
  • 3.1.5 safety extra-low voltage
  • 3.1.6 safety isolating transformer
  • 3.1.7 isolated limited secondary circuit
  • 3.1.8 pilot duty
  • 3.1.9 transient overvoltage
  • 3.1.10 rated impulse voltage
  • 3.1.11 overvoltage category
  • 3.1.12 SELV system
  • 3.1.13 PELV system
  • 3.2 Definitions of types of control according to purpose
  • 3.2.1 electrical control
  • 3.2.2 manual control
  • 3.2.3 automatic control
  • 3.2.4 sensing control
  • 3.2.5 thermostat
  • 3.2.6 temperature limiter
  • 3.2.7 thermal cut-out
  • 3.2.8 energy regulator
  • 3.2.9 time-based control
  • 3.2.10 electrically operated control
  • 3.2.11 timer
  • 3.2.12 time switch
  • 3.2.13 electrically operated valve
  • 3.2.14 electrically operated mechanism
  • 3.2.15 operating control
  • 3.2.16 protective control
  • 3.2.17 multipurpose control
  • 3.2.18 multifunctional control
  • 3.2.19 system
  • 3.3 Definitions relating to the function of controls
  • 3.3.1 initiation
  • 3.3.2 transmission
  • 3.3.3 operation
  • 3.3.4 automatic action
  • 3.3.5 slow-make slow-break automatic action
  • 3.3.6 manual action
  • 3.3.7 actuation
  • 3.3.8 located position
  • 3.3.9 intermediate position
  • 3.3.10 activating quantity
  • 3.3.11 operating value
  • 3.3.12 operating time
  • 3.3.13 operating sequence
  • 3.3.14 response value
  • 3.3.15 trip-free
  • 3.3.16 setting
  • 3.3.17 setting by the control manufacturer
  • 3.3.18 setting by the equipment manufacturer
  • 3.3.19 setting by the installer
  • 3.3.20 setting by the user
  • 3.3.21 set point
  • 3.3.22 adjustable set point
  • 3.3.23 duty cycle
  • 3.3.24 cycle of contact operation
  • 3.3.25 operating differential
  • 3.3.26 adjustable differential
  • 3.3.27 fixed differential
  • 3.3.28 maximum working pressure
  • 3.3.29 maximum temperature
  • 3.3.30 remotely actuated control function
  • 3.3.31 safety shut-down
  • 3.3.32 mounting surface temperature
  • 3.3.33 touch current
  • 3.4 Definitions relating to disconnection and interruption
  • 3.4.1 all-pole disconnection
  • 3.4.2 full disconnection
  • 3.4.3 micro-disconnection
  • 3.4.4 micro-interruption
  • 3.4.5 OFF position
  • 3.4.6 electronic disconnection
  • 3.5 Definitions of types of control according to construction
  • 3.5.1 integrated control

1 Scope

This part of IEC 60730 applies to automatic displacement electrical controls - for use in, on, or in association with appliances for household and similar use; NOTE 1 Through this document, the word "control" means "displacement electrical control". EXAMPLE 1 Displacement electrical controls used in electrical pressure cookers with gross volume up to 25 l, with working pressure over 4 kPa and less than 150 kPa.

  • that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC;
  • used in, on, or in association with equipment that use electricity;
  • that are mechanically or electrically operated, responsive to change of position of point of action.

NOTE 2 Requirements for manual switches not forming part of an automatic control are covered in IEC 61058-1-1. This document applies to - inherent safety of automatic electro-mechanical displacement electrical controls; - functional safety of automatic electro-mechanical displacement electrical controls; - the operating values, operating times, and operating sequences where such are associated with equipment safety; - displacement electrical controls having temperature sensing element(s), in which cases additional requirements can be considered to be necessary. Requirements for temperature sensing controls are included in IEC 60730-2-9.

This document specifies the requirements for construction, operation and testing of automatic displacement electrical controls used in, on, or in association with equipment. This document does not - apply to automatic electronic controls; - take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer applies.

NOTE 3 For more information about guidance to the application of displacement electrical controls, see Annex AA.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

IEC 60038, IEC standard voltages IEC 60065:2014, Audio, video and similar electronic apparatus – Safety requirements IEC 60068-2-75, Environmental testing – Part 2-75: Tests – Test Eh: Hammer tests IEC 60085, Electrical insulation – Thermal evaluation and designation

IEC 60099-1:1991, Surge arresters – Part 1: Non-linear resistor type gapped surge arresters

for a.c. systems IEC 60112:2020, Method for the determination of the proof and the comparative tracking indices of solid insulating materials IEC 60127 (all parts), Miniature fuses IEC 60227-1, Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V – Part 1: General requirements IEC 60245-1, Rubber insulated cables – Rated voltages up to and including 450/750 V – Part 1:

General requirements IEC 60269 (all parts), Low-voltage fuses IEC 60335-1:2020, Household and similar electrical appliances – Safety – Part 1: General requirements IEC 60384-14, Fixed capacitors for use in electronic equipment – Part 14: Sectional specification – Fixed capacitors for electromagnetic interference suppression and connection to the supply mains IEC 60384-16, Fixed capacitors for use in electronic equipment – Part 16: Sectional specification – Fixed metallized polypropylene film dielectric DC capacitors IEC 60384-17, Fixed capacitors for use in electronic equipment – Part 17: Sectional specification – Fixed metallized polypropylene film dielectric AC and pulse capacitors IEC 60417, Graphical symbols for use on equipment IEC 60423, Conduit systems for cable management – Outside diameters of conduits for electrical installations and threads for conduits and fittings

IEC 60529:1989, Degrees of protection provided by enclosures (IP code) IEC 60529:1989/AMD1:1999 IEC 60529:1989/AMD2:2013 IEC 60539 (all parts), Directly heated negative temperature coefficient thermistors

IEC 60664-1:2007 , Insulation coordination for equipment within low-voltage systems – Part 1:

Principles, requirements and tests IEC TR 60664-2 (all parts), Insulation coordination for equipment within low-voltage systems IEC 60664-3:2016, Insulation coordination for equipment within low-voltage systems – Part 3:

Use of coating, potting or moulding for protection against pollution IEC 60664-4, Insulation coordination for equipment within low-voltage systems – Part 4:

Consideration of high-frequency voltage stress

Withdrawn.

Withdrawn.

IEC 60695-2-10, Fire hazard testing – Part 2-10: Glowing/hot-wire based test methods – Glow-wire apparatus and common test procedure IEC 60695-2-11:2021, Fire hazard testing – Part 2-11: Glowing/hot-wire based test methods – Glow-wire flammability test method for end-products (GWEPT) IEC 60695-10-2, Fire hazard testing – Part 10-2: Abnormal heat – Ball pressure test method IEC 60738 (all parts), Thermistors – Directly heated positive temperature coefficient IEC 60747-5-5, Semiconductor devices – Part 5-5: Optoelectronic devices – Photocouplers IEC 60884-1, Plugs and socket-outlets for household and similar purposes – Part 1: General requirements IEC 60884-2-5:2017, Plugs and socket-outlets for household and similar purposes – Part 2-5:

Particular requirements for adaptors IEC 60998-2-2, Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units IEC 60998-2-3, Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units IEC 60999-1, Connecting devices – Electrical copper conductors – Safety requirements for screw-type and screwless-type clamping units – Part 1: General requirements and particular 2 2 up to 35 mm (included) requirements for clamping units for conductors from 0,2 mm IEC 61000-3-2, Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) IEC 61000-3-3, Electromagnetic compatibility (EMC) – Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection IEC 61000-3-11, Electromagnetic compatibility (EMC) – Part 3-11: Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems – Equipment with rated current ≤ 75 A and subject to conditional connection IEC 61000-3-12, Electromagnetic compatibility (EMC) – Part 3-12: Limits – Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase IEC 61000-4-2:2008, Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test IEC 61000-4-3, Electromagnetic compatibility (EMC) – Part 4-3: Testing and measurement techniques – Radiated, radio-frequency, electromagnetic field immunity test IEC 61000-4-4, Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test

IEC 61000-4-5:2014, Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test IEC 61000-4-5:2014/AMD1:2017 IEC 61000-4-6, Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields IEC 61000-4-8, Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement techniques – Power frequency magnetic field immunity test IEC 61000-4-11, Electromagnetic compatibility (EMC) – Part 4-11: Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests for equipment with current up to 16 A per phase IEC 61000-4-13:2002, Electromagnetic compatibility (EMC) – Part 4-13: Testing and measurement techniques – Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests IEC 61000-4-13:2002 /AMD1:2009 IEC 61000-4-13:2002 /AMD2:2015 IEC 61000-4-20, Electromagnetic compatibility (EMC) – Part 4-20: Testing and measurement techniques – Emission and immunity testing in transverse electromagnetic (TEM) waveguides IEC 61000-4-21, Electromagnetic compatibility (EMC) – Part 4-21: Testing and measurement techniques – Reverberation chamber test methods IEC 61000-4-22, Electromagnetic compatibility (EMC) – Part 4-22: Testing and measurement techniques – Radiated emissions and immunity measurements in fully anechoic rooms (FARs) IEC 61000-4-28, Electromagnetic compatibility (EMC) – Part 4-28: Testing and measurement techniques – Variation of power frequency, immunity test for equipment with input current not exceeding 16A per phase IEC 61000-6-1:2016, Electromagnetic compatibility (EMC) – Part 6-1: Generic standards – Immunity standard for residential, commercial and light-industrial environments IEC 61000-6-2:2016, Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity standard for industrial environments IEC 61000-6-3:2020, Electromagnetic compatibility (EMC) – Part 6-3: Generic standards – Emission standard for equipment in residential environments IEC 61000-6-4:2018, Electromagnetic compatibility (EMC) – Part 6-4: Generic standards – Emission standard for industrial environments IEC 61051-1, Varistors for use in electronic equipment – Part 1: Generic specification IEC 61051-2, Varistors for use in electronic equipment – Part 2: Sectional specification for surge suppression varistors IEC 61051-2-2, Varistors for use in electronic equipment – Part 2: Blank detail specification for zinc oxide surge suppression varistors. Assessment level E IEC 61210, Connecting devices – Flat quick-connect terminations for electrical copper conductors – Safety requirements

IEC 61249 (all parts), Materials for printed boards and other interconnecting structures IEC 61558-2-6, Safety of transformers, reactors, power supply units and combinations thereof − Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers for general applications IEC 61558-2-16, Safety of transformers, reactors, power supply units and combinations thereof − Part 2-16: Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units for general applications IEC 61810-3, Electromechanical elementary relays – Part 3: Replays with forcibly guided (mechanically linked) contacts IEC 62151, Safety of equipment electrically connected to a telecommunication network IEC 62319 (all parts), Polymeric thermistors – Directly heated positive step function temperature coefficient IEC 62326 (all parts), Printed boards IEC 62368-1, Audio/video, information and communication technology equipment – Part 1:

Safety requirements IEC 63044 (all parts), Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) CISPR 11, Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics – Limits and methods of measurement CISPR 14-1:2020, Electromagnetic compatibility – Requirements for household appliances, electric tools and similar apparatus – Part 1: Emission CISPR 32:2015, Electromagnetic compatibility of multimedia equipment – Emission requirements CISPR 32:2015/AMD1:2019 ISO 4046-4:2016, Paper, board, pulps and related terms − Vocabulary − Part 4: Paper and board grades and converted products ISO 7637-2:2011, Road vehicles – Electrical disturbances from conduction and coupling – Part 2:

Electrical transient conduction along supply lines only ISO 7637-3:2016, Road vehicles – Electrical disturbances from conduction and coupling – Part 3:

Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines ISO 16484 (all parts), Building automation and control systems (BACS)

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses:

- IEC Electropedia: available at http://www.electropedia.org/ - ISO Online browsing platform: available at http://www.iso.org/obp NOTE Where the terms "voltage" and "current" are used, they imply the RMS values, unless otherwise specified.

3.1 Definitions relating to ratings, voltages, currents, frequencies, and wattages

3.1.1 rated voltage, current, frequency or wattage

voltage, current, frequency or wattage assigned to a control by the manufacturer Note 1 to entry: For three phase supply, the rated voltage is the line-to-line voltage.

3.1.2 rated voltage, current, frequency or wattage range

voltage, current, frequency or wattage ranges assigned to the control by the manufacturer and expressed by lower and upper values

3.1.3 working voltage

highest RMS value of the AC or DC voltage across any particular insulation which can occur when the equipment is supplied at rated voltage Note 1 to entry: Transient overvoltages are disregarded.

Note 2 to entry: Open-circuit conditions and normal operating conditions are taken into account.

3.1.4 extra-low voltage

ELV voltage not exceeding the maximum values of 50 V AC (RMS), 70,7 V AC (peak) or 120 V DC (ripple-free) between conductors and between conductors and earth which is permitted to be maintained indefinitely under normal and single-fault conditions Note 1 to entry: Ripple-free is conventionally defined as an RMS ripple voltage of not more than 10 % of the DC component.

Note 2 to entry: The use of ELV other than in SELV system or PELV system is not a protective measure against electric shock, this is in line with IEC 61140:2016.

3.1.5 safety extra-low voltage

protective extra-low voltage SELV/PELV voltage for use in SELV system or PELV system between simultaneously accessible part(s) and between any accessible part and earth, not exceeding the limits of 30 V AC (RMS), 42,4 V AC (peak) or 60 V DC (ripple free) under normal and single-fault condition, which is provided by an independent source (such as motor generators, and batteries) or when obtained from higher voltage is obtained by a safety isolating transformer or a converter with separate windings providing equivalent insulation Note 1 to entry: The voltage limits are based on the assumption that the safety isolating transformer is supplied at its rated voltage. For the purpose of the output test in 12.2.1, the secondary output voltage limit shall be increased as specified in 19.2.2.

Note 2 to entry: Transformers used in converters that have separate windings and provide equivalent insulation are covered under IEC 61558-2-6 and IEC 61558-2-16.

Note 3 to entry: SELV/PELV limits are defined regardless of any special condition which may occur in installation. Different requirements may be specified in the relevant electrical installation standards (e.g. IEC 60364 series) or in the applicable local regulations.

Note 4 to entry: Ripple-free is conventionally defined as an RMS ripple voltage of not more than 10 % of the DC component.

Note 5 to entry: SELV/PELV limits may be different in other product or system standards. In case a control is declared exclusively for use in applications governed by a different standard, the limits set by the application standard apply (e.g. controls to be used exclusively in household appliances according IEC 60335 set of standards or connected to HBES/BACS systems according to IEC 63044-3 accept different SELV voltage limits).

3.1.6 safety isolating transformer

transformer, the input winding of which is electrically separated from the output winding by an insulation at least equivalent to double insulation or reinforced insulation, and which is intended to supply safety extra-low voltage circuits

3.1.7 isolated limited secondary circuit

circuit from an isolated secondary winding of a transformer having a maximum capacity of 100 VA and an open-circuit secondary voltage rating not exceeding 1 000 V

3.1.8 pilot duty

class of operation in which the ultimate electrical load is controlled by an auxiliary means such as a relay or contactor

3.1.9 transient overvoltage

overvoltage with a duration of a few milliseconds or less, oscillatory or non-oscillatory, usually highly damped Note 1 to entry: Transient overvoltages may be immediately followed by temporary overvoltages. In such cases the two overvoltages are considered as separate events.

Note 2 to entry: IEC 60071-1 defines three types of transient overvoltages, namely slow-front overvoltages, fastfront overvoltages and very fast-front overvoltages according to their time to peak, tail or total duration, and possible superimposed oscillations.

[SOURCE: IEC 60050-614:2016, 614-03-14]

3.1.10 rated impulse voltage

impulse withstand voltage assigned by the manufacturer to the equipment or to a part of it, characterizing the specified withstand capability of its insulation against overvoltages Note 1 to entry: The term rated impulse voltage is the same as impulse withstand voltage given in IEC 60664-1 overvoltage category.

3.1.11 overvoltage category

numeral defining a transient overvoltage condition Note 1 to entry: Overvoltage categories I, II, III, and IV are used. See Annex D. [SOURCE: IEC 60050-581:2008, 581-21-02, modified − Note 1 to entry has been added]

3.1.12 SELV system

electrical system in which the voltage cannot exceed the values in 3.1.5:

  • under normal conditions, and
  • under single fault conditions, including protective earth faults in other electric circuits [SOURCE: IEC 60050-826:2004, 826-12-31; modified − "the value of extra-low voltage" has been changed to "the values in 3.1.5" and Note 1 to entry has been deleted]

3.1.13 PELV system

electrical system in which the voltage cannot exceed the values in 3.1.5:

  • under normal conditions, and
  • under single fault conditions, except protective earth faults in other electric circuits [SOURCE: IEC 60050-826:2004, 826-12-32; modified − "the value of extra-low voltage" has been changed to "the values in 3.1.5" and Note 1 to entry has been deleted]

3.2 Definitions of types of control according to purpose

3.2.1 electrical control

device used in, on or in association with an equipment for the purpose of varying or modifying the output from such equipment, and which embodies the aspects of initiation, transmission and operation Note 1 to entry: Hereinafter, electrical control is referred to as "control". Note 2 to entry: At least one of these aspects shall be electrical or electronic.

3.2.2 manual control

control in which the initiation is by actuation and in which the transmission and the operation are both direct and without any intentional time delay

3.2.3 automatic control

control in which at least one aspect is non-manual

3.2.4 sensing control

automatic control in which initiation is by an element sensitive to the particular activating quantity declared, for example, temperature, current, humidity, light, liquid level, position, pressure or velocity

...

Contents

  • 1 Domaine d'application
  • 2 Références normatives
  • 3 Termes et définitions
  • 3.2 Définitions des différents types de dispositifs de commande en fonction de
  • 3.4 Définitions relatives aux coupures et interruptions de circuit
  • 3.8 Définitions concernant les éléments constituants des dispositifs de commande
  • 3.8.3 organe de manœuvre
  • 4 Généralités
  • 5 Informations techniques exigées
  • 6 Fonction du dispositif de commande D ou E
  • 16 Limites de température des surfaces de montage (T ) 16.5, C
  • 19.3.1 Température maximale de la surface de montage (T ) si elle est
  • 18 Non applicable
  • 19 Non applicable
  • 33 Action de type 2 3.4.106 D ou E
  • 9.4.3 H.17
  • 43 Non applicable
  • 48 Non applicable
  • 50 Non applicable
  • 51 Non applicable
  • 52 Non applicable
  • 53 Non applicable
  • 54 Non applicable
  • 56 Non applicable
  • 60 Non applicable
  • 61 Non applicable
  • 62 Non applicable
  • 65 Non applicable
  • 66 Non applicable
  • 75 Non applicable
  • 76 Non applicable
  • 77 Non applicable
  • 78 Non applicable
  • 79 Non applicable
  • 80 Non applicable
  • 81 Non applicable
  • 82 Non applicable
  • 83 Non applicable
  • 84 Non applicable
  • 86 Non applicable
  • 6 Protection contre les chocs électriques
  • 7 Dispositions en vue de la mise à la terre de protection
  • 8 Bornes et connexions
  • 9 Exigences de construction
  • 10 Parties filetées et connexions
  • 11 Lignes de fuite, distances dans l'air et distances à travers l'isolation solide
  • 12 Éléments constituants
  • 13 Évaluation des pannes sur les circuits électroniques
  • 14 Résistance à l'humidité et à la poussière
  • 15 Résistance d'isolement et rigidité diélectrique
  • 16 Échauffements
  • 17 Tolérances de fabrication et dérive
  • 18 Contraintes climatiques
  • 19 Endurance
  • 19.1 Exigences générales
  • 19.3 Conditions thermiques pour les essais
  • 19.4 Conditions manuelles et mécaniques des essais
  • 19.14 Évaluation de la conformité
  • 19.15 Essai pour les dispositifs de commande à usages particuliers
  • 20 Résistance mécanique
  • 20.2 Résistance aux chocs
  • 20.3 Dispositifs de commande séparés
  • 20.4 Dispositifs de commande intercalés dans un câble souple
  • 20.5 Dispositifs de commande à traction
  • 20.6 Dispositifs de commande au pied
  • 20.8 Essai de flexion
  • 20.9 Essai des dispositifs d'arrêt de traction et de torsion
  • 21 Résistance à la chaleur, au feu et aux courants de cheminement
  • 22 Résistance à la corrosion
  • 23 Exigences de compatibilité électromagnétique (CEM) – Émission
  • 24 Fonctionnement normal
  • 25 Exigences de compatibilité électromagnétique (CEM) – Immunité
  • 26 Essais en fonctionnement anormal
  • Annexe H
  • Annexe AA
  • Bibliographie

1 Domaine d'application

L'article de la Partie 1 est remplacé par le suivant:

La présente partie de l'IEC 60730 s'applique aux dispositifs de commande électrique de déplacement automatiques - destinés à être utilisés dans, sur, ou avec des appareils domestiques et à usage analogue; NOTE 1 Dans le présent document, le terme "dispositif de commande" signifie "dispositif de commande électrique de déplacement".

EXEMPLE 1 Dispositifs de commande électrique de déplacement utilisés dans les autocuiseurs électriques dont le volume brut atteint 25 l et dont la pression de service est supérieure à 4 kPa et inférieure à 150 kPa. - en courant alternatif et en courant continu dont la tension assignée ne dépasse pas 690 V en courant alternatif ou 600 V en courant continu; - utilisés dans, sur ou avec un matériel électrique; - à fonctionnement mécanique ou électrique, en réponse à un changement de position du point d'action.

NOTE 2 Les exigences pour les interrupteurs manuels ne faisant pas partie d'un dispositif de commande automatique sont couverts par l'IEC 61058-1-1.

Le présent document s'applique:

  • à la sécurité intrinsèque des dispositifs de commande électrique de déplacement électromécaniques automatiques;
  • à la sécurité fonctionnelle des dispositifs de commande électrique de déplacement électromécaniques automatiques;
  • aux valeurs de fonctionnement, aux temps de fonctionnement et aux séquences de fonctionnement dans la mesure où ils interviennent dans la sécurité du matériel;
  • aux dispositifs de commande électrique de déplacement dotés de dispositifs thermosensibles, auquel cas des exigences supplémentaires peuvent s'avérer nécessaires. Les exigences relatives aux dispositifs de commande thermosensibles sont incluses dans l'IEC 60730-2-9.

Le présent document spécifie les exigences de construction, de fonctionnement et d'essai des dispositifs de commande électrique de déplacement automatiques utilisés dans, sur ou en association avec un matériel.

Le présent document:

- ne s'applique pas aux dispositifs de commande automatique; - ne prend pas en considération la valeur de réponse d'une action automatique d'un dispositif de commande lorsqu'elle est influencée par la méthode de montage du dispositif de commande dans le matériel. Dans les cas où une telle valeur de réponse est importante du point de vue de la protection de l'utilisateur ou de l'environnement, la valeur spécifiée dans la norme particulière du matériel ou déterminée par le fabricant s'applique. NOTE 3 Pour plus d'informations sur l'application des dispositifs de commande électrique de déplacement, voir l'Annexe AA.

2 Références normatives

L'article de la Partie 1 s'applique.

3 Termes et définitions

L'article de la Partie 1 s'applique avec les exceptions suivantes:

3.2 Définitions des différents types de dispositifs de commande en fonction de

l'application Définitions supplémentaires:

3.2.101 dispositif de commande électrique de déplacement dispositif de commande automatique dans lequel le point d'action se déplace suite au déplacement du conteneur en raison d'une variation de pression Note 1 à l'article: Dans le cas d'un autocuiseur de riz, le conteneur est un contenant intérieur. Note 2 à l'article: Le dispositif de commande électrique de déplacement est considéré comme un dispositif de commande de fonctionnement avec une action de type 2. En principe, un dispositif de commande de protection est installé sur le produit final pour prévenir tout phénomène dangereux, par conséquent, il n'est pas nécessaire de vérifier la solidité du mécanisme de verrouillage automatique. 3.2.102 limiteur de position dispositif de commande électrique de déplacement destiné à maintenir une position en dessous d'une valeur particulière dans les conditions de fonctionnement normal et dont le réglage peut être réalisé par le fabricant du produit final Note 1 à l'article: Un limiteur de position peut être du type à réarmement manuel. 3.2.103 régulateur de position dispositif de commande électrique de déplacement à fonctionnement cyclique destiné à maintenir une position entre deux valeurs particulières dans les conditions de fonctionnement normal et dont le réglage peut être réalisé par le fabricant du produit final

3.4 Définitions relatives aux coupures et interruptions de circuit

Définitions supplémentaires:

3.4.101 position libre P f état initial du point d'action du dispositif de commande électrique de déplacement Note 1 à l'article: P est indiqué comme la position de déplacement 0 à la Figure 101. f Note 2 à l'article: En règle générale, la position libre se trouve à la position repérée. 3.4.102 position de déconnexion P d position à laquelle le contact est déconnecté du circuit par le mécanisme d'action sous l'effet d'une force externe Note 1 à l'article: P est indiqué à la Figure 101.

d 3.4.103 position de verrouillage automatique P s position dans laquelle le mécanisme de verrouillage automatique fonctionne, alors que le déplacement peut se poursuivre lorsque le contact est déconnecté

3.4.105 position limite P

position la plus éloignée du mécanisme d'action du dispositif de commande électrique de déplacement qui peut être atteinte sous l'effet d'une force externe, le mécanisme d'action pouvant revenir à la position libre lorsque la force externe est relâchée Note 1 à l'article: P est indiqué à la Figure 101.

3.4.105 position de réarmement P r position du mécanisme d'action dans laquelle le contact déconnecté est reconnecté lorsque le déplacement est réduit Note 1 à l'article: P est indiqué à la Figure 101.

r 3.4.106 distance de déplacement pour la déconnexion distance entre la position libre et la position de déconnexion 3.4.107 distance de déplacement pour le verrouillage automatique distance entre la position de déconnexion et la position de verrouillage automatique 3.4.108 distance de déplacement limite distance entre la position libre et la position limite 3.4.109 distance de déplacement pour le réarmement distance entre la position libre et la position de réarmement 3.4.110 point d'action point sur le dispositif de commande électrique de déplacement auquel le déplacement a lieu

3.8 Définitions concernant les éléments constituants des dispositifs de commande

3.8.3 organe de manœuvre

Note supplémentaire:

Note 101 à l'article: A l'Article 19 du présent document, le terme "organe de manœuvre" inclut la partie qui est mécaniquement déplacée, tirée, poussée ou tournée pour déclencher une action de commande.

4 Généralités

L'article de la Partie 1 s'applique avec l'exception suivante:

4.3.4.5.1 Alinéa supplémentaire:

Pour les dispositifs de commande électrique de déplacement conçus avec au moins deux positions de détection pour des fonctions multiples, les essais appropriés doivent être appliqués à chaque position de détection individuelle, une à la fois.

5 Informations techniques exigées

L'article de la Partie 1 s'applique avec les exceptions suivantes:

Tableau 1 – Informations techniques exigées et méthodes pour fournir ces informations Informations Article ou paragraphe Méthode Modifications:

3.2, 4.3.4.2, 4.3.4.5,

6 Fonction du dispositif de commande D ou E

19.15, 3.2.101, 3.2.102

16 Limites de température des surfaces de montage (T ) 16.5, C

s

19.3.1 Température maximale de la surface de montage (T ) si elle est

smax supérieure à 20 K au-dessus de T 19.15.101 max 19.15.102 NOTE 1 Si le dispositif de commande électrique de déplacement

est prévu pour le mode d'installation 2, la température du montant de AA.1 fixation indiquée à la Figure AA.2 est prise comme T .

s

18 Non applicable

19 Non applicable

20 Nombre de cycles automatiques (A) pour chaque action 13.1.3.3, automatique.

Tableau 14, - Au moins 6 000 cycles pour l'action de déconnexion 19.7.6, - Au moins 30 cycles pour le mécanisme de verrouillage 19.8.4, automatique 19.15.101 NOTE 2 Pour les dispositifs de commande à plusieurs actions automatiques, une valeur différente peut être déclarée pour chaque action.

33 Action de type 2 3.4.106 D ou E

9.4.3 H.17

43 Non applicable

48 Non applicable

50 Non applicable

51 Non applicable

52 Non applicable

53 Non applicable

54 Non applicable

56 Non applicable

60 Non applicable

61 Non applicable

62 Non applicable

65 Non applicable

66 Non applicable

75 Non applicable

76 Non applicable

77 Non applicable

78 Non applicable

79 Non applicable

80 Non applicable

Informations Article ou paragraphe Méthode

81 Non applicable

82 Non applicable

83 Non applicable

84 Non applicable

86 Non applicable

Points supplémentaires:

101 Position libre (P ) 3.4.101, f 9.1.4, D ou E Figure 101, H.17.5.1

102 3.4.106, Distance de déplacement pour la déconnexion 9.4.3, D ou E Figure 101, Figure 102 103 Distance de déplacement pour le verrouillage automatique 3.4.107, 19.15.102, D ou E Figure 101 104 Distance de déplacement limite 3.4.108, 19.15.101, D ou E Figure 101

105 3.4.109, Distance de déplacement pour le réarmement D ou E Figure 101 106 Procédures de l'essai d'endurance de la distance de déplacement 19.15 X

limite 107 Vitesse de manœuvre du mécanisme de manœuvre utilisé pour les 19.15 X essais à vitesse accélérée pendant l'essai d'endurance 108 Temps de maintien maximal de la distance de déplacement limite 19.15 X 109 Responsabilité du fabricant du produit final AA.1 D ou E 110 Température ambiante maximale du dispositif de commande AA.4.2 D ou E électrique de déplacement 111 Limite de la force applicable au dispositif de commande 9.4.3 X électrique de déplacement d Non applicable e Non applicable g Non applicable k Non applicable Notes supplémentaires:

La distance de déplacement pour la déconnexion est réglée en fonction des exigences des utilisateurs.

La distance de déplacement pour le réarmement est réglée en fonction des exigences des utilisateurs.

Cela inclut le nombre de cycles pour l'essai de distance de déplacement limite. Le nombre de cycles pour les actions position de déconnexion et position de verrouillage automatique sont identifiés dans l'exigence 20.

6 Protection contre les chocs électriques

L'article de la Partie 1 s'applique.

7 Dispositions en vue de la mise à la terre de protection

L'article de la Partie 1 s'applique.

8 Bornes et connexions

L'article de la Partie 1 s'applique.

9 Exigences de construction

L'article de la Partie 1 s'applique avec les exceptions suivantes.

9.3.4 Réglage par le fabricant

Note supplémentaire:

NOTE 101 La méthode selon laquelle une vis est scellée de façon permanente par collage ou par des moyens similaires est considérée comme acceptable.

Paragraphe supplémentaire:

9.3.101 Dispositifs de commande électrique de déplacement avec fonction de protection intégrée Le dispositif de commande de déplacement avec fonction de protection intégrée doit être évalué comme un dispositif de commande de protection. Le limiteur de position intègre des fonctions de protection. Pour le limiteur de position, dès que le déplacement du point d'action atteint la distance de déplacement pour le verrouillage automatique, il ne doit pas être reconnecté, même si la force externe appliquée diminue ou disparaît, sauf s'il est réarmé manuellement.

La conformité est vérifiée par l'essai suivant:

...

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.2 Definitions of types of control according to purpose
  • 3.4 Definitions relating to disconnection and interruption
  • 3.8 Definitions relating to component parts of controls
  • 3.8.3 actuating member
  • 4 General
  • 5 Required technical information
  • 6 Purpose of control D or E
  • 16 Temperature limits of mounting surfaces (T ) 16.5, C
  • 19.3.1 Maximum temperature of mounting surface (T ) if it is more than
  • 20 K above T
  • 18 Not applicable
  • 19 Not applicable
  • 33 Type 2 action 3.4.106 D or E
  • 9.4.3 H.17
  • 43 Not applicable
  • 48 Not applicable
  • 50 Not applicable
  • 51 Not applicable
  • 52 Not applicable
  • 53 Not applicable
  • 54 Not applicable
  • 56 Not applicable
  • 60 Not applicable
  • 61 Not applicable
  • 62 Not applicable
  • 65 Not applicable
  • 66 Not applicable
  • 75 Not applicable
  • 76 Not applicable
  • 77 Not applicable
  • 78 Not applicable
  • 79 Not applicable
  • 80 Not applicable
  • 81 Not applicable
  • 82 Not applicable
  • 83 Not applicable
  • 84 Not applicable
  • 86 Not applicable
  • 6 Protection against electric shock
  • 7 Provision for protective earthing
  • 8 Terminals and terminations
  • 9 Constructional requirements
  • 10 Threaded parts and connections
  • 11 Creepage distances, clearances and distances through solid insulation
  • 12 Components
  • 13 Fault assessment on electronic circuits
  • 14 Moisture and dust resistance
  • 15 Electric strength and insulation resistance
  • 16 Heating
  • 17 Manufacturing deviation and drift
  • 18 Environmental stress
  • 19 Endurance
  • 19.1 General requirements
  • 19.3 Thermal conditions for the tests
  • 19.4 Manual and mechanical conditions for the tests
  • 19.14 Evaluation of compliance
  • 19.15 Test for particular purpose controls
  • 20 Mechanical strength
  • 20.2 Impact resistance
  • 20.3 Free-standing controls
  • 20.4 In-line cord controls
  • 20.5 Pull-cord actuated controls
  • 20.6 Foot actuated controls
  • 20.8 Flexing – test
  • 20.9 Cord anchorages – test
  • 21 Resistance to heat, fire and tracking
  • 22 Resistance to corrosion
  • 23 Electromagnetic compatibility (EMC) requirements – Emission
  • 24 Normal operation
  • 25 Electromagnetic compatibility (EMC) requirements – Immunity
  • 26 Abnormal operation tests
  • Annex H
  • Annex AA
  • Bibliography

1 Scope

This clause of Part 1 is replaced by the following:

This part of IEC 60730 applies to automatic displacement electrical controls - for use in, on, or in association with appliances for household and similar use; NOTE 1 Through this document, the word "control" means "displacement electrical control". EXAMPLE 1 Displacement electrical controls used in electrical pressure cookers with gross volume up to 25 l, with working pressure over 4 kPa and less than 150 kPa.

  • that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC;
  • used in, on, or in association with equipment that use electricity;
  • that are mechanically or electrically operated, responsive to change of position of point of action.

NOTE 2 Requirements for manual switches not forming part of an automatic control are covered in IEC 61058-1-1. This document applies to - inherent safety of automatic electro-mechanical displacement electrical controls; - functional safety of automatic electro-mechanical displacement electrical controls; - the operating values, operating times, and operating sequences where such are associated with equipment safety; - displacement electrical controls having temperature sensing element(s), in which cases additional requirements can be considered to be necessary. Requirements for temperature sensing controls are included in IEC 60730-2-9.

This document specifies the requirements for construction, operation and testing of automatic displacement electrical controls used in, on, or in association with equipment. This document does not - apply to automatic electronic controls; - take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer applies.

NOTE 3 For more information about guidance to the application of displacement electrical controls, see Annex AA.

2 Normative references

This clause of Part 1 is applicable.

3 Terms and definitions

This clause of Part 1 is applicable except as follows:

3.2 Definitions of types of control according to purpose

Additional definitions:

3.2.101 displacement electrical control automatic control where the displacement of point of action occurs through the displacement of the container due to pressure change Note 1 to entry: The container is an inner pot in the case of rice cooker. Note 2 to entry: The displacement electrical control is considered an operating control with a type 2 action and normally a protective control is provided on the end product to prevent a hazard, therefore there is no need to verify the robustness of the self-locking mechanism.

3.2.102 position limiter displacement electrical control which is intended to keep a position below one particular value during normal operating conditions and which may have provision for setting by the endproduct manufacturer Note 1 to entry: A position limiter can be manual reset type.

3.2.103 position regulator cycling displacement electrical control, which is intended to keep a position between two particular values under normal operating conditions and which may have provision for setting by the end-product manufacturer

3.4 Definitions relating to disconnection and interruption

Additional definitions:

3.4.101 free position P f initial state of the point of action of the displacement electrical control Note 1 to entry: P is indicated as the position of 0 displacement in Figure 101. f Note 2 to entry: In general, free position is at located position. 3.4.102 disconnection position P d position where the contact is disconnected from the circuit by the action mechanism under the external force Note 1 to entry: P is indicated in Figure 101.

d 3.4.103 self-locking position P s position in which the self-locking mechanism just operates while the displacement can continue to increase when the contact is disconnected

3.4.104 limit position P

farthest position of the action mechanism of the displacement electrical control that can be reached under external force where the action mechanism can recover to the free position when the external force is released Note 1 to entry: P is indicated in Figure 101.

3.4.105 reset position P r position of the action mechanism where the disconnected contact will be re-connected when the displacement is reduced Note 1 to entry: P is indicated in Figure 101.

r 3.4.106 disconnection travel distance distance between free position and disconnection position 3.4.107 self-locking travel distance distance between disconnection position and self-locking position 3.4.108 limit travel distance distance between free position and limit position 3.4.109 reset travel distance distance between free position and reset position 3.4.110 point of action point on the displacement electrical control at which the displacement is made

3.8 Definitions relating to component parts of controls

3.8.3 actuating member

Additional note:

Note 101 to entry: In Clause 19 of this document, the term "actuating member" includes that part which is mechanically moved, pulled, pushed or turned to cause initiation of a control action.

4 General

This clause of Part 1 is applicable except as follows:

4.3.4.5.1 Additional paragraph:

For the displacement electrical controls designed with two or more sensing positions for multiple functions, the relevant tests shall be applied to the individual sensing position, one at a time.

5 Required technical information

This clause of Part 1 is applicable except as follows:

Table 1 – Required technical information and methods of providing these information Information Clause or subclause Method Modifications:

3.2, 4.3.4.2, 4.3.4.5,

6 Purpose of control D or E

19.15, 3.2.101, 3.2.102

16 Temperature limits of mounting surfaces (T ) 16.5, C

s

19.3.1 Maximum temperature of mounting surface (T ) if it is more than

smax

20 K above T

19.15.101 max 19.15.102 NOTE 1 If the displacement electrical control is intended for installation mode 2, the temperature of mounting post as shown in AA.1 Figure AA.2 is taken as T .

s

18 Not applicable

19 Not applicable

20 Number of automatic cycles (A) for each automatic action. 13.1.3.3, - Minimum 6 000 cycles for disconnection action Table 14, - Minimum 30 cycles for self-locking mechanmism 19.7.6, 19.8.4, NOTE 2 For controls having more than one automatic action, a different value can be declared for each.

19.15.101

33 Type 2 action 3.4.106 D or E

9.4.3 H.17

43 Not applicable

48 Not applicable

50 Not applicable

51 Not applicable

52 Not applicable

53 Not applicable

54 Not applicable

56 Not applicable

60 Not applicable

61 Not applicable

62 Not applicable

65 Not applicable

66 Not applicable

75 Not applicable

76 Not applicable

77 Not applicable

78 Not applicable

79 Not applicable

80 Not applicable

81 Not applicable

Information Clause or subclause Method

82 Not applicable

83 Not applicable

84 Not applicable

86 Not applicable

Additional items:

101 Free position (P ) 3.4.101, f 9.1.4, D or E Figure 101, H.17.5.1

102 3.4.106, Disconnection travel distance 9.4.3, D or E Figure 101, Figure 102 103 Self-locking travel distance 3.4.107, 19.15.102, D or E Figure 101 104 Limit travel distance 3.4.108, 19.15.101, D or E Figure 101

105 3.4.109, Reset travel distance D or E Figure 101

Procedures of limit travel distance endurance test 19.15 X 107 Operation speed of the operation mechanism used for accelerated 19.15 X speed testing during the endurance test 108 Maximum hold on time of the limit travel distance 19.15 X 109 End product manufacturer's responsibility AA.1 D or E 110 Maximum ambient temperature of the displacement electrical AA.4.2 D or E control 111 Limit of force applicable to the displacement electrical control 9.4.3 X d Not applicable e Not applicable g Not applicable k Not applicable Additional notes:

The disconnection travel distance is set according to the requirements of users.

The reset travel distance is set according to the requirements of users.

It includes the number of cycles for limit travel distance test. The number of cycles for disconnection position action and self-locking position action are identified in requirement 20.

6 Protection against electric shock

This clause of Part 1 is applicable.

7 Provision for protective earthing

This clause of Part 1 is applicable.

8 Terminals and terminations

This clause of Part 1 is applicable.

9 Constructional requirements

This clause of Part 1 is applicable except as follows.

9.3.4 Setting by the manufacturer

Additional note:

NOTE 101 The method that a screw is sealed permanently by gluing or similar means is considered as acceptable. Additional subclause:

9.3.101 Displacement electrical controls with integrated protective function The displacement electrical control with integrated protective function shall be evaluated as a protective control. The position limiter contains protective functions. For the position limiter, once the displacement of the point of action reaches the self-locking travel distance, it shall not be reconnected, even if the applied external force decreases or disappears, unless it is reset manually.

Compliance is checked by the following test.

...