Interpretation Sheet 2 - Explosive atmospheres - Part 0: Equipment - General requirements

Feuille d'interprétation 2 - Atmosphères explosives - Partie 0: Matériel - Exigences générales

General Information

Status
Published
Publication Date
26-Jun-2019
Drafting Committee
WG 22 - TC 31/WG 22
Current Stage
PPUB - Publication issued
Start Date
27-Jun-2019
Completion Date
26-Jul-2019

Relations

Effective Date
05-Sep-2023
Standard

IEC 60079-0:2017/ISH2:2019 - Interpretation Sheet 2 - Explosive atmospheres - Part 0: Equipment - General requirements Released:6/27/2019

English and French language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Frequently Asked Questions

IEC 60079-0:2017/ISH2:2019 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Interpretation Sheet 2 - Explosive atmospheres - Part 0: Equipment - General requirements". This standard covers: Interpretation Sheet 2 - Explosive atmospheres - Part 0: Equipment - General requirements

Interpretation Sheet 2 - Explosive atmospheres - Part 0: Equipment - General requirements

IEC 60079-0:2017/ISH2:2019 is classified under the following ICS (International Classification for Standards) categories: 29.260.20 - Electrical apparatus for explosive atmospheres. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 60079-0:2017/ISH2:2019 has the following relationships with other standards: It is inter standard links to IEC 60079-0:2017. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase IEC 60079-0:2017/ISH2:2019 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of IEC standards.

Standards Content (Sample)


 IEC 2019
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
IEC 60079-0
Edition 7.0  2017-12
EXPLOSIVE ATMOSPHERES –
Part 0: Equipment – General requirements

INTERPRETATION SHEET 2
This interpretation sheet has been prepared by IEC technical committee 31: Equipment for
explosive atmospheres.
The text of this interpretation sheet is based on the following documents:
DISH Report on voting
31/1469/DISH 31/1486/RVDISH
Full information on the voting for the approval of this interpretation sheet can be found in the
report on voting indicated in the above table.

___________
Question:
How shall marking be shown for equipment covered by both the electrical and non-electrical
standards (IEC 60079 and ISO 80079 series)?
Answer:
Equipment which includes both an electrical part and a non-electrical part shall have
combined marking. For example:
Ex db h IIA T4 Gb
Ex h tb IIIC T135 °C Db
ICS 29.260.20
IEC 60079-0:2017-12/ISH2:2019-06(en-fr)

– 2 – IEC 60079-0:2017/ISH2:2019
 IEC 2019
It will be clearer for the user that the combined risk of the electrical part and the non-electrical
part, covered by a single certificate, has been assessed for the complete equipment, stating
one EPL, one equipment Group and one temperature class for Gas and the same for Dust
(but showing a maximum surface temperature instead of a temperature class). It is also noted
that Ex Components are not marked with either a temperature class (Group II) or a maximum
surface temperature (Group III).
For equipment where separate certificates have been prepared, with one for the electrical
parts, and one for the non-electrical parts, it is appropriate to have separate electrical and
non-electrical marking strings, each with its own associated certificate number.
NOTE Additional guidance on the marking of assemblies is given in IEC TS 60079-46.

 IEC 2019
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...