IEC 60189-3:2007
(Main)Low-frequency cables and wires with PVC insulation and PVC sheath - Part 3: Equipment wires with solid or stranded conductor wires, PVC insulated, in singles, pairs and triples
Low-frequency cables and wires with PVC insulation and PVC sheath - Part 3: Equipment wires with solid or stranded conductor wires, PVC insulated, in singles, pairs and triples
is applicable to equipment wires with solid or stranded conductor, polyvinyl chloride (PVC) insulated, in singles, pairs and triples to be used for internal wiring of telecommunication equipment, industrial and consumer electronic equipment.
General Information
Overview
IEC 60189-3:2007 - part of the IEC 60189 series - is the international standard for PVC-insulated equipment wires (singles, pairs and triples) used for internal wiring of telecommunication, industrial and consumer electronic equipment. This fourth edition (2007) defines construction, material, mechanical, thermal and electrical requirements for low-frequency wires with PVC insulation and PVC sheath.
Key topics and technical requirements
- Scope: Applies to solid or stranded conductors, PVC insulated, in single, paired or triple configurations for internal equipment wiring.
- Conductor material & type:
- Annealed copper in accordance with IEC 60028; very small gauges (0.12 mm, 0.15 mm diameters and 0.035 mm2 area) may be copper alloy.
- Solid (single strand) or stranded (concentric or bunching) conductors permitted.
- Conductor finish: plain or tinned.
- Joints allowed only when necessary; joint breaking strength must be ≥ 85% of unjointed conductor. Joints in complete stranded conductors are not permitted.
- Insulation:
- Material: PVC (polyvinyl chloride or vinyl‑chloride/vinyl‑acetate copolymers).
- Thickness: minimum values defined in Annex A; maximum insulated wire diameter calculated per Annex C.
- Insulation must fit closely without adhering to conductor; stripping must be possible without damage.
- Colour and identification:
- Colours follow IEC 60304 standard colours; two-colour marking (rings/helices) rules and minimum marking dimensions specified.
- Note: YELLOW‑GREEN reserved for protective earth.
- Assembly:
- Configurations: single, pair or triple; maximum lay length for twisted pairs/triples ≤ 120 mm.
- Tests and performance:
- Mechanical: conductor elongation, insulation physical integrity.
- Thermal and climatic: insulation shrinkage after overheating, cold bend, heat shock.
- Fire/climate: resistance to flame propagation.
- Electrical: conductor resistance (IEC 60028), dielectric strength, insulation resistance.
- Delivery: on reels or coils with suitable protection.
Applications and who uses this standard
- Cable and wire manufacturers for product design and quality control.
- OEMs and equipment designers (telecommunications, consumer electronics, industrial controls) specifying internal wiring.
- Procurement and compliance teams writing technical specifications and acceptance tests.
- Test laboratories and certification bodies conducting mechanical, thermal and electrical verification.
Related standards
- IEC 60189-1 (general test and measuring methods)
- IEC 60028 (copper resistance standards)
- IEC 60304 (standard colours for insulation)
- IEC 60344, IEC 60649, ISO 105 (referenced for calculation methods and colour fastness)
Keywords: IEC 60189-3, PVC insulated wires, equipment wires, low-frequency cables, internal wiring, conductor specifications, wire colour codes, electrical testing.
Standards Content (Sample)
INTERNATIONAL IEC
STANDARD 60189-3
Fourth edition
2007-05
Low-frequency cables and wires
with PVC insulation and PVC sheath –
Part 3:
Equipment wires with solid or stranded
conductor wires, PVC insulated, in singles,
pairs and triples
Reference number
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
INTERNATIONAL IEC
STANDARD 60189-3
Fourth edition
2007-05
Low-frequency cables and wires
with PVC insulation and PVC sheath –
Part 3:
Equipment wires with solid or stranded
conductor wires, PVC insulated, in singles,
pairs and triples
PRICE CODE
Commission Electrotechnique Internationale M
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue
– 2 – 60189-3 © IEC:2007(E)
CONTENTS
FOREWORD.3
1 Scope.5
2 Normative references .5
3 Terms and definitions .5
4 Wire construction and dimensions .5
4.1 Conductor .5
4.1.1 Conductor material .5
4.1.2 Type of conductor.6
4.1.3 Conductor finish .6
4.1.4 Conductor dimensions .6
4.1.5 Continuity of conductor.6
4.2 Insulation .6
4.2.1 insulation material .6
4.2.2 Insulation thickness .6
4.2.3 Application of the insulation.6
4.2.4 Colour of insulation.7
4.3 Twisting of insulated conductors.8
4.4 Identification of insulated conductors.8
4.5 Delivery.8
5 Mechanical requirements.8
5.1 Conductor .8
5.2 Insulation .9
6 Thermal stability and climatic requirements .9
6.1 Measurement of insulation shrinkage after over-heating of conductor.9
6.2 Resistance to flame propagation .10
6.3 Cold bend test.10
6.4 Heat shock test .10
7 Electrical requirements .10
7.1 Electrical resistance of conductor .10
7.2 Dielectric strength .10
7.3 Insulation resistance .10
Annex A (normative) Single equipment wires .11
Annex B (normative) Equipment wires in pairs and triples .12
Annex C (normative) Calculation of the maximum diameter of insulated conductors.13
Figure 1 – Construction.8
60189-3 © IEC:2007(E) – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
LOW-FREQUENCY CABLES AND WIRES
WITH PVC INSULATION AND PVC SHEATH –
Part 3: Equipment wires with solid or stranded conductor wires,
PVC insulated, in singles, pairs and triples
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60189-3 has been prepared by subcommittee 46C: Wires and
symmetrical cables, of IEC technical committee 46: Cables, wires, waveguides, r.f.
connectors, r.f. and microwave passive components and accessories.
This fourth edition cancels and replaces the third edition published in 1988 and amendment 1
(1989). This edition constitutes a technical revision.
This edition includes an update of the technical characteristics.
– 4 – 60189-3 © IEC:2007(E)
The text of this standard is based on the following documents:
FDIS Report on voting
46C/822/FDIS 46C/830/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
The list of all the parts of the IEC 60189 series, under the general title Low-frequency cables
and wires with PVC insulation and PVC sheath, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.
60189-3 © IEC:2007(E) – 5 –
LOW-FREQUENCY CABLES AND WIRES
WITH PVC INSULATION AND PVC SHEATH –
Part 3: Equipment wires with solid or stranded conductor wires,
PVC insulated, in singles, pairs and triples
1 Scope
This part of IEC 60189 is applicable to equipment wires with solid or stranded conductor,
polyvinyl chloride (PVC) insulated, in singles, pairs and triples to be used for internal wiring of
telecommunication equipment, industrial and consumer electronic equipment.
NOTE It is the responsibility of the manufacturer to establish quality assurance by quality control procedures which
will ensure that the product will meet the requirements of this standard. It is not intended that a complete testing
programme must be carried out on every length of conductor. When the purchaser wishes to specify acceptance
tests or other quality procedures, it is essential that agreement be reached between the purchaser and the
manufacturer by the time of ordering.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document ( including any amendments ) applies.
IEC 60028, International standard of resistance for copper
IEC 60189-1:2007, Low-frequency cables and wires with PVC insulation and PVC sheath –
Part 1: General test and measuring methods
IEC 60304, Standard colours for insulation for low-frequency cables and wires
IEC 60344, Guide to the calculation of resistance of plain
...
Frequently Asked Questions
IEC 60189-3:2007 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Low-frequency cables and wires with PVC insulation and PVC sheath - Part 3: Equipment wires with solid or stranded conductor wires, PVC insulated, in singles, pairs and triples". This standard covers: is applicable to equipment wires with solid or stranded conductor, polyvinyl chloride (PVC) insulated, in singles, pairs and triples to be used for internal wiring of telecommunication equipment, industrial and consumer electronic equipment.
is applicable to equipment wires with solid or stranded conductor, polyvinyl chloride (PVC) insulated, in singles, pairs and triples to be used for internal wiring of telecommunication equipment, industrial and consumer electronic equipment.
IEC 60189-3:2007 is classified under the following ICS (International Classification for Standards) categories: 29.060.10 - Wires; 29.060.20 - Cables. The ICS classification helps identify the subject area and facilitates finding related standards.
You can purchase IEC 60189-3:2007 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of IEC standards.
The article discusses the standard IEC 60189-3:2007, which pertains to low-frequency cables and wires with PVC insulation and PVC sheath. Specifically, it focuses on equipment wires with solid or stranded conductor wires that are PVC insulated. These wires are used for internal wiring in telecommunication equipment, as well as industrial and consumer electronic equipment.
기사 제목: IEC 60189-3:2007 - PVC 절연 및 PVC 외피를 가진 저주파 케이블 및 전선 - 제3부: 단일, 쌍 및 삼중 PVC 절연, 단선 또는 복선 도체로 된 장비 전선 기사 내용: 본 기사는 단선 또는 복선 도체, 폴리비닐 클로라이드(PVC) 절연된 장비 전선에 적용되며, 통신 장비, 산업용 및 가전용 전자 장비의 내부 배선에 사용된다.
記事のタイトル:IEC 60189-3:2007 - PVC絶縁およびPVC被覆を持つ低周波ケーブルとワイヤー - 第3部:単独、ペア、およびトリプルのソリッドまたはストランド導体ワイヤーの装置用ワイヤー 記事の内容:この記事では、ソリッドまたはストランド導体ワイヤーでPVC絶縁された装置用ワイヤーに焦点を当て、通信機器や産業および家電製品の内部配線に使用されるIEC 60189-3:2007の標準について説明しています。








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...