Electromagnetic compatibility (EMC) - Part 4-3 : Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

IEC 61000-4-3:2020 is applicable to the immunity requirements of electrical and electronic equipment to radiated electromagnetic energy. It establishes test levels and the required test procedures. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to radiated, radio-frequency electromagnetic fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against RF electromagnetic fields from RF sources not in close proximity to the EUT. The test environment is specified in Clause 6. NOTE 1 As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. TC 77 and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular immunity tests for their products. NOTE 2 Immunity testing against RF sources in close proximity to the EUT is defined in IEC 61000-4-39. Particular considerations are devoted to the protection against radio-frequency emissions from digital radiotelephones and other RF emitting devices. NOTE 3 Test methods are defined in this part for evaluating the effect that electromagnetic radiation has on the equipment concerned. The simulation and measurement of electromagnetic radiation is not adequately exact for quantitative determination of effects. The test methods defined in this basic document have the primary objective of establishing an adequate reproducibility of testing configuration and repeatability of test results at various test facilities. This document is an independent test method. It is not possible to use other test methods as substitutes for claiming compliance with this document. This fourth edition cancels and replaces the third edition published in 2006, Amendment 1:2007 and Amendment 2:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - testing using multiple test signals has been described; - additional information on EUT and cable layout has been added; - the upper frequency limitation has been removed to take account of new services; - the characterization of the field as well as the checking of power amplifier linearity of the immunity chain are specified.

Elektromagnetische Verträglichkeit (EMV) - Teil 4-3: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen hochfrequente elektromagnetische Felder

Compatibilité électromagnétique (CEM) - Partie 4-3 : Techniques d'essai et de mesure - Essai d'immunité aux champs électromagnétiques rayonnés aux fréquences radioélectriques

IEC 61000-4-3:2020 traite des exigences d'immunité des matériels électriques et électroniques à l'énergie électromagnétique rayonnée. Elle définit les niveaux d'essai et les procédures d'essai exigés. Le présent document a pour objet d'établir une référence commune d'évaluation des performances en matière d’immunité des matériels électriques et électroniques soumis à des champs électromagnétiques aux fréquences radioélectriques. La méthode d'essai documentée dans la présente partie de l’IEC 61000 décrit une méthode cohérente d’évaluation de l'immunité d'un équipement ou d'un système aux champs électromagnétiques à fréquences radioélectriques générés par des sources de rayonnement aux fréquences radioélectriques qui ne se trouvent pas à proximité immédiate de l’EUT. L’environnement d’essai est spécifié à l’Article 6. NOTE 1 Comme cela est décrit dans le Guide IEC 107, cette publication est une publication fondamentale en CEM destinée à être utilisée par les comités de produits de l’IEC. Comme cela est également indiqué dans le Guide 107, les comités de produits de l’IEC sont responsables de déterminer s’il convient d’appliquer ou non la présente norme d’essai d’immunité et, si c’est le cas, ils sont responsables de déterminer les niveaux d’essai et les critères de performance appropriés. Le comité d’études 77 et ses sous-comités sont prêts à coopérer avec les comités de produits à l’évaluation de la valeur des essais d’immunité particuliers pour leurs produits. NOTE 2 Les essais d’immunité aux sources de rayonnement aux fréquences radioélectriques à proximité de l’EUT sont définis dans l’IEC 61000-4-39. Des considérations particulières sont consacrées à la protection contre les émissions aux fréquences radioélectriques des radiotéléphones numériques et d'autres dispositifs d'émission RF. NOTE 3 La présente partie définit des méthodes d'essai pour évaluer l'incidence des rayonnements électromagnétiques sur le matériel concerné. La simulation et le mesurage des rayonnements électromagnétiques ne sont pas suffisamment exacts pour déterminer quantitativement les effets. Les méthodes d'essai définies dans le présent document fondamental ont été principalement mises au point pour obtenir une bonne reproductibilité de la configuration des essais et une bonne répétabilité des résultats d’essai sur différentes installations d'essai. Le présent document présente une méthode d'essai indépendante. Il n'est pas possible d'utiliser d'autres méthodes d'essai comme variantes pour se conformer au présent document. Cette quatrième édition annule et remplace la troisième édition parue en 2006, l'Amendement 1:2007 et l'Amendement 2:2010. Cette édition constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente.
description des essais qui utilisent des signaux d’essai multiples;
ajout d’informations supplémentaires sur l’EUT et la disposition des câbles;
la limitation en matière de fréquences supérieures a été supprimée pour tenir compte des nouveaux services;
la caractérisation du champ ainsi que la vérification de la linéarité de l’amplificateur de puissance de la chaîne d'immunité sont spécifiées.

Elektromagnetna združljivost (EMC) - 4-3. del: Preskusne in merilne tehnike - Preskušanje odpornosti proti sevanim radiofrekvenčnim elektromagnetnim poljem

General Information

Status
Published
Publication Date
29-Oct-2020
Current Stage
6060 - Document made available - Publishing
Start Date
30-Oct-2020
Completion Date
30-Oct-2020

Relations

Overview

EN IEC 61000-4-3:2020 (equivalent to EN IEC 61000-4-3:2020 / IEC 61000-4-3 Edition 4.0) is the international test method for radiated, radio‑frequency electromagnetic field immunity of electrical and electronic equipment. It defines common reference test procedures, test environments and test levels to evaluate how an equipment under test (EUT) performs when exposed to radiated RF electromagnetic fields from sources that are not in close proximity. This edition is a technical revision that supersedes earlier 2006 versions and amendments.

Key topics and technical requirements

  • Test objective and scope: A basic EMC publication intended as a reference for product committees; product committees decide the applicability and performance criteria for their products.
  • Test environment and equipment: Specification of test facilities (anechoic chambers, open-area test sites), instrumentation, antennas and the Uniform Field Area (UFA) requirements (Clause 6).
  • Test levels and frequency ranges: Guidance for selecting test levels and frequency ranges appropriate to product types and exposure scenarios.
  • Test setup and EUT layout: Detailed rules for arranging table-top, floor-standing and human‑body‑mounted equipment, plus cable layout and routing to ensure reproducible results.
  • Test procedures and execution: Step sizes, laboratory reference conditions (climatic and electromagnetic), and evaluation of results.
  • Multiple-signal testing: Procedures for testing with concurrent RF signals and guidance on intermodulation and power requirements.
  • Amplifier linearity and field characterization: Requirements to check power amplifier linearity, limit harmonics and verify the actual field delivered to the EUT.
  • Measurement uncertainty and probe calibration: Annexes provide uncertainty budgeting, E‑field probe calibration methods and chamber validation.
  • Informative annexes: Practical guidance (antenna types, anechoic chamber use, large EUT setups, testing rationale for digital radio emissions, etc.).
  • Independent test method: The standard is prescriptive; other methods cannot be substituted when claiming compliance.

Practical applications

  • Designing and validating consumer, industrial and medical products for immunity to ambient RF fields.
  • Establishing repeatable test programs in EMC laboratories (anechoic chambers, OATS).
  • Defining manufacturer compliance evidence for product committees and regulatory submissions.
  • Assessing susceptibility to emissions from mobile radios, RF transmitters and digital radiotelephony.
  • Troubleshooting immunity issues by reproducing field exposure and verifying mitigation measures (shielding, grounding, filtering).

Who should use this standard

  • EMC test engineers and accredited test laboratories
  • Product design and compliance engineers
  • Manufacturers planning market access in regions recognizing EN/IEC standards
  • Regulatory bodies and product committees defining immunity requirements

Related standards

  • IEC 61000-4 series (general EMC testing framework)
  • IEC 61000-4-6 (conducted RF immunity)
  • IEC 61000-4-39 (close-proximity RF immunity)
  • IEC 61000-4-20 / 4-21 / 4-22 and CISPR 16-1-4 (measurement and instrumentation references)

Keywords: EMC, IEC 61000-4-3, radiated immunity, RF electromagnetic field immunity test, uniform field area, anechoic chamber, EUT, amplifier linearity, probe calibration, multiple-signal testing.

Standard
EN IEC 61000-4-3:2021 - BARVE
English language
84 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Frequently Asked Questions

EN IEC 61000-4-3:2020 is a standard published by CLC. Its full title is "Electromagnetic compatibility (EMC) - Part 4-3 : Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test". This standard covers: IEC 61000-4-3:2020 is applicable to the immunity requirements of electrical and electronic equipment to radiated electromagnetic energy. It establishes test levels and the required test procedures. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to radiated, radio-frequency electromagnetic fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against RF electromagnetic fields from RF sources not in close proximity to the EUT. The test environment is specified in Clause 6. NOTE 1 As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. TC 77 and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular immunity tests for their products. NOTE 2 Immunity testing against RF sources in close proximity to the EUT is defined in IEC 61000-4-39. Particular considerations are devoted to the protection against radio-frequency emissions from digital radiotelephones and other RF emitting devices. NOTE 3 Test methods are defined in this part for evaluating the effect that electromagnetic radiation has on the equipment concerned. The simulation and measurement of electromagnetic radiation is not adequately exact for quantitative determination of effects. The test methods defined in this basic document have the primary objective of establishing an adequate reproducibility of testing configuration and repeatability of test results at various test facilities. This document is an independent test method. It is not possible to use other test methods as substitutes for claiming compliance with this document. This fourth edition cancels and replaces the third edition published in 2006, Amendment 1:2007 and Amendment 2:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - testing using multiple test signals has been described; - additional information on EUT and cable layout has been added; - the upper frequency limitation has been removed to take account of new services; - the characterization of the field as well as the checking of power amplifier linearity of the immunity chain are specified.

IEC 61000-4-3:2020 is applicable to the immunity requirements of electrical and electronic equipment to radiated electromagnetic energy. It establishes test levels and the required test procedures. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to radiated, radio-frequency electromagnetic fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against RF electromagnetic fields from RF sources not in close proximity to the EUT. The test environment is specified in Clause 6. NOTE 1 As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. TC 77 and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular immunity tests for their products. NOTE 2 Immunity testing against RF sources in close proximity to the EUT is defined in IEC 61000-4-39. Particular considerations are devoted to the protection against radio-frequency emissions from digital radiotelephones and other RF emitting devices. NOTE 3 Test methods are defined in this part for evaluating the effect that electromagnetic radiation has on the equipment concerned. The simulation and measurement of electromagnetic radiation is not adequately exact for quantitative determination of effects. The test methods defined in this basic document have the primary objective of establishing an adequate reproducibility of testing configuration and repeatability of test results at various test facilities. This document is an independent test method. It is not possible to use other test methods as substitutes for claiming compliance with this document. This fourth edition cancels and replaces the third edition published in 2006, Amendment 1:2007 and Amendment 2:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - testing using multiple test signals has been described; - additional information on EUT and cable layout has been added; - the upper frequency limitation has been removed to take account of new services; - the characterization of the field as well as the checking of power amplifier linearity of the immunity chain are specified.

EN IEC 61000-4-3:2020 is classified under the following ICS (International Classification for Standards) categories: 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.

EN IEC 61000-4-3:2020 has the following relationships with other standards: It is inter standard links to EN 61000-4-3:2006/A1:2008, EN 61000-4-3:2006, EN 61000-4-3:2006/IS1:2009, EN 61000-4-3:2006/A2:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN IEC 61000-4-3:2020 is associated with the following European legislation: EU Directives/Regulations: 2014/30/EU; Standardization Mandates: M/490. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase EN IEC 61000-4-3:2020 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.

Standards Content (Sample)


SLOVENSKI STANDARD
01-januar-2021
Nadomešča:
SIST EN 61000-4-3:2006
SIST EN 61000-4-3:2006/A1:2008
SIST EN 61000-4-3:2006/A2:2011
SIST EN 61000-4-3:2006/IS1:2009
Elektromagnetna združljivost (EMC) - 4-3. del: Preskusne in merilne tehnike -
Preskušanje odpornosti proti sevanim radiofrekvenčnim elektromagnetnim poljem
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques -
Radiated, radiofrequency, electromagnetic field immunity test
Elektromagnetische Verträglichkeit (EMV) - Teil 4-3: Prüf- und Messverfahren - Prüfung
der Störfestigkeit gegen hochfrequente elektromagnetische Felder
Compatibilité électromagnétique (CEM) - Partie 4-3 : Techniques d'essai et de mesure -
Essai d'immunité aux champs électromagnétiques rayonnés aux fréquences
radioélectriques
Ta slovenski standard je istoveten z: EN IEC 61000-4-3:2020
ICS:
33.100.20 Imunost Immunity
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN IEC 61000-4-3

NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2020
ICS 33.100.20 Supersedes EN 61000-4-3:2006, EN 61000-4-
3:2006/IS1:2009 and all of its amendments and corrigenda
(if any)
English Version
Electromagnetic compatibility (EMC) - Part 4-3 : Testing and
measurement techniques - Radiated, radio-frequency,
electromagnetic field immunity test
(IEC 61000-4-3:2020)
Compatibilité électromagnétique (CEM) - Partie 4-3 : Elektromagnetische Verträglichkeit (EMV) - Teil 4-3: Prüf-
Techniques d'essai et de mesure - Essai d'immunité aux und Messverfahren - Prüfung der Störfestigkeit gegen
champs électromagnétiques rayonnés aux fréquences hochfrequente elektromagnetische Felder
radioélectriques (IEC 61000-4-3:2020)
(IEC 61000-4-3:2020)
This European Standard was approved by CENELEC on 2020-10-13. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2020 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 61000-4-3:2020 E

European foreword
The text of document 77B/830/FDIS, future edition 4 of IEC 61000-4-3, prepared by SC 77B "High
frequency phenomena" of IEC/TC 77 "Electromagnetic compatibility" was submitted to the IEC-
CENELEC parallel vote and approved by CENELEC as EN IEC 61000-4-3:2020.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2021-07-13
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2023-10-13
document have to be withdrawn
This document supersedes EN 61000-4-3:2006 and all of its amendments and corrigenda (if any).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association.
Endorsement notice
The text of the International Standard IEC 61000-4-3:2020 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards
indicated:
IEC 61000-4 series NOTE Harmonized as EN 61000-4 series
IEC 61000-4-6 NOTE Harmonized as EN 61000-4-6
IEC 61000-4-20:2010 NOTE Harmonized as EN 61000-4-20:2010 (not modified)
IEC 61000-4-21 NOTE Harmonized as EN 61000-4-21
IEC 61000-4-22 NOTE Harmonized as EN 61000-4-22
IEC 61000-4-39 NOTE Harmonized as EN 61000-4-39
CISPR 16-1-4 NOTE Harmonized as EN IEC 55016-1-4
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod), the
relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60050-161 - International Electrotechnical Vocabulary. - -
Chapter 161: Electromagnetic compatibility

IEC 61000-4-3 ®
Edition 4.0 2020-09
INTERNATIONAL
STANDARD
colour
inside
Electromagnetic compatibility (EMC) –

Part 4-3: Testing and measurement techniques – Radiated, radio-frequency

electromagnetic field immunity test

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
ICS 33.100.20 ISBN 978-2-8322-8678-4

– 2 – IEC 61000-4-3:2020 © IEC 2020
CONTENTS
FOREWORD . 6
INTRODUCTION . 8
1 Scope . 9
2 Normative references . 9
3 Terms, definitions and abbreviated terms . 9
3.1 Terms and definitions . 9
3.2 Abbreviated terms . 13
4 General . 14
5 Test levels and frequency ranges . 14
5.1 Selection of test level . 14
5.2 Test frequency ranges . 16
6 Test equipment . 17
6.1 Test instrumentation . 17
6.2 Description of the test facility . 17
6.3 Uniform field area (UFA) . 18
6.3.1 Characteristics of the UFA . 18
6.3.2 Constant field strength level setting method. 23
6.3.3 Constant power level setting method . 24
7 Test setup . 25
7.1 General . 25
7.2 Arrangement of table-top equipment . 26
7.3 Arrangement of floor-standing equipment . 28
7.4 Arrangement of wiring . 29
7.5 Arrangement of human body-mounted equipment . 30
8 Test procedure . 30
8.1 General . 30
8.2 Laboratory reference conditions . 30
8.2.1 General . 30
8.2.2 Climatic conditions . 30
8.2.3 Electromagnetic conditions . 30
8.3 Execution of the test . 30
8.4 Step sizes . 32
9 Evaluation of test results . 32
10 Test report . 32
Annex A (informative) Rationale for the choice of modulation for tests related to the
protection against RF emissions from digital radio services . 34
A.1 Summary of available modulation methods . 34
A.2 Experimental results . 35
A.3 Secondary modulation effects . 38
A.4 Conclusion . 38
Annex B (informative) Field generating antennas . 39
B.1 Biconical antenna . 39
B.2 Log-periodic antenna . 39
B.3 Combination antennas . 39
B.4 Horn antenna and double ridge wave guide antenna . 39

IEC 61000-4-3:2020 © IEC 2020 – 3 –
Annex C (informative) Use of anechoic chambers . 40
C.1 General anechoic chamber information . 40
C.2 Use of ferrite-lined chambers at frequencies above 1 GHz . 40
C.2.1 Problems caused by the use of ferrite-lined chambers for radiated field
immunity tests at frequencies above 1 GHz . 40
C.2.2 Solutions to reduce reflections . 41
Annex D (informative) Amplifier compression and non-linearity . 42
D.1 Objective of limiting amplifier distortion . 42
D.2 Possible problems caused by harmonics and saturation . 42
D.3 Limiting the harmonic content in the field . 42
D.4 Effect of linearity characteristic on the immunity test . 43
D.4.1 General . 43
D.4.2 Evaluation method of the linearity characteristic . 43
Annex E (informative) Guidance for product committees on the selection of test levels . 47
E.1 General . 47
E.2 Test levels related to general purposes . 47
E.3 Test levels related to the protection against RF emissions from digital radio
telephones . 48
E.4 Special measures for fixed transmitters. 49
Annex F (informative) Selection of test methods . 50
Annex G (informative) Cable layout details . 52
G.1 Intentions of EUT setup for radiated immunity test . 52
G.2 Cable in the field . 52
G.3 Cables leaving the test area . 52
G.4 Turning the EUT cabinets . 52
Annex H (informative)  Examples of test setups for large and heavy EUTs . 54
H.1 EUTs with bottom fed cables . 54
H.2 EUTs with overhead cables . 55
H.3 EUTs with multiple cables and AEs . 56
H.4 Large EUTs with side fed cables and multiple UFA windows . 57
Annex I (informative) Testing with multiple signals . 58
I.1 General . 58
I.2 Intermodulation . 58
I.3 Power requirements . 59
I.4 Level setting requirements . 60
I.5 Linearity and harmonics checks . 60
I.6 EUT performance criteria with multiple signals . 60
Annex J (informative) Measurement uncertainty due to test instrumentation . 61
J.1 General . 61
J.2 Uncertainty budgets for level setting . 61
J.2.1 Definition of the measurand . 61
J.2.2 MU contributors of the measurand . 61
J.2.3 Calculation examples for expanded uncertainty . 62
J.2.4 Explanation of terms . 63
J.3 Application . 64
J.4 Reference documents . 64
Annex K (informative) Calibration method for E-field probes . 65
K.1 Overview. 65

– 4 – IEC 61000-4-3:2020 © IEC 2020
K.2 Probe calibration requirements . 65
K.2.1 General . 65
K.2.2 Calibration frequency range . 65
K.2.3 Frequency steps . 65
K.2.4 Field strength . 66
K.3 Requirements for calibration instrumentation . 66
K.3.1 General . 66
K.3.2 Harmonics and spurious signals . 66
K.3.3 Linearity check for probe . 67
K.3.4 Determination of the gain of the standard horn antennas . 68
K.4 Field probe calibration in anechoic chambers . 69
K.4.1 Calibration environments . 69
K.4.2 Validation of anechoic chambers for field probe calibration . 69
K.4.3 Probe calibration procedure . 75
K.5 Other probe calibration environments and methods . 77
K.5.1 General . 77
K.5.2 Field probe calibration using TEM cells . 77
K.5.3 Field probe calibration using waveguide chambers . 78
K.5.4 Field probe calibration using open-ended waveguides . 79
K.5.5 Calibration of field probes by gain transfer method . 79
K.6 Reference documents . 79
Bibliography . 81

Figure 1 – Definition of the 80 % amplitude modulated (AM) test signal and the
waveshapes occurring . 16
Figure 2 – Example of suitable test facility . 18
Figure 3 – Level setting setup . 19
Figure 4 – Dimensions of sixteen-point uniform field area . 20
Figure 5 – Minimum UFA size having a fifth grid point in the centre . 21
Figure 6 – Measuring setup . 23
Figure 7 – Example of EUT setup and cable layout for table top EUT having a cable
that leaves the test setup . 26
Figure 8 – Example of EUT setup (top view) . 28
Figure C.1 – Multiple reflections in an existing small anechoic chamber . 41
Figure C.2 – Most of the reflected waves are eliminated (applies for top and side view) . 41
Figure D.1 – Amplifier linearity measurement setup . 44
Figure D.2 – Example of linearity curve . 45
Figure D.3 – Example of gain deviation . 45
Figure H.1 – Example of a test setup for EUT with bottom fed underground cables
(CMADs not shown) . 54
Figure H.2 – Example of a test setup for EUTs with overhead cables . 55
Figure H.3 – Example of a setup of EUTs with multiple cables and AEs . 56
Figure H.4 – Large EUTs with side fed cables and multiple UFAs . 57
Figure I.1 – Test frequencies f and f and intermodulation frequencies of the second
1 2
and third order . 58
Figure J.1 – Example of influences upon level setting . 62
Figure K.1 – Example of linearity for probe . 68

IEC 61000-4-3:2020 © IEC 2020 – 5 –
Figure K.2 – Setup for measuring net power to a transmitting device . 70
Figure K.3 – Test setup for chamber validation test. 72
Figure K.4 – Detail for measurement position ∆L . 72
Figure K.5 – Example of data adjustment . 73
Figure K.6 – Example of the test layout for antenna and probe . 74
Figure K.7 – Test setup for chamber validation test. 74
Figure K.8 – Example of alternative chamber validation data . 75
Figure K.9 – Field probe calibration layout . 76
Figure K.10 – Field probe calibration layout (top view) . 76
Figure K.11 – Cross-sectional view of a waveguide chamber . 78

Table 1 – Test levels . 15
Table 2 – Amplitude modulation characteristics at output of signal generator . 15
Table 3 – Requirements for uniform field area for application of full illumination and
partial illumination . 22
Table A.1 – Comparison of modulation methods . 35
Table A.2 – Relative interference levels . 36
Table A.3 – Relative immunity levels . 37
Table E.1 – Examples of test levels, associated protection distances and performance
criteria . 48
Table J.1 – Level setting process . 62
Table J.2 – Test process . 63
Table K.1 – Calibration field strength level . 66
Table K.2 – Example for the probe linearity check. 67

– 6 – IEC 61000-4-3:2020 © IEC 2020
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
ELECTROMAGNETIC COMPATIBILITY (EMC) –

Part 4-3: Testing and measurement techniques –
Radiated, radio-frequency electromagnetic field immunity test

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC Publication(s)"). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61000-4-3 has been prepared by subcommittee 77B: High frequency
phenomena, of IEC technical committee 77: Electromagnetic compatibility.
It forms part 4-3 of IEC 61000. It has the status of a basic EMC publication in accordance with
IEC Guide 107.
This fourth edition cancels and replaces the third edition published in 2006, Amendment 1:2007
and Amendment 2:2010. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) testing using multiple test signals has been described;
b) additional information on EUT and cable layout has been added;
c) the upper frequency limitation has been removed to take account of new services;
d) the characterization of the field as well as the checking of power amplifier linearity of the
immunity chain are specified.
IEC 61000-4-3:2020 © IEC 2020 – 7 –
The text of this International Standard is based on the following documents:
FDIS Report on voting
77B/830/FDIS 77B/825/RVD
Full information on the voting for the approval of this International Standard can be found in the
report on voting indicated in the above table.
This document has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts in the IEC 61000 series, published under the general title Electromagnetic
compatibility (EMC), can be found on the IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
the specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct understanding
of its contents. Users should therefore print this document using a colour printer.

– 8 – IEC 61000-4-3:2020 © IEC 2020
INTRODUCTION
IEC 61000 is published in separate parts according to the following structure:
Part 1: General
General considerations (introduction, fundamental principles)
Definitions, terminology
Part 2: Environment
Description of the environment
Classification of the environment
Compatibility levels
Part 3: Limits
Emission limits
Immunity limits (in so far as they do not fall under the responsibility of the product
committees)
Part 4: Testing and measurement techniques
Measurement techniques
Testing techniques
Part 5: Installation and mitigation guidelines
Installation guidelines
Mitigation methods and devices
Part 6: Generic standards
Part 9: Miscellaneous
Each part is further subdivided into several parts, published either as international standards
or as technical specifications or technical reports, some of which have already been published
as sections. Others will be published with the part number followed by a dash and a second
number identifying the subdivision (example: IEC 61000-6-1).
This part is an international standard which gives immunity requirements and test procedures
related to radiated, radio-frequency, electromagnetic fields.

IEC 61000-4-3:2020 © IEC 2020 – 9 –
ELECTROMAGNETIC COMPATIBILITY (EMC) –

Part 4-3: Testing and measurement techniques –
Radiated, radio-frequency electromagnetic field immunity test

1 Scope
This part of IEC 61000 is applicable to the immunity requirements of electrical and electronic
equipment to radiated electromagnetic energy. It establishes test levels and the required test
procedures.
The object of this document is to establish a common reference for evaluating the immunity of
electrical and electronic equipment when subjected to radiated, radio-frequency
electromagnetic fields. The test method documented in this part of IEC 61000 describes a
consistent method to assess the immunity of an equipment or system against RF
electromagnetic fields from RF sources not in close proximity to the EUT. The test environment
is specified in Clause 6.
NOTE 1 As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC.
As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test
standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels
and performance criteria. TC 77 and its sub-committees are prepared to co-operate with product committees in the
evaluation of the value of particular immunity tests for their products.
NOTE 2 Immunity testing against RF sources in close proximity to the EUT is defined in IEC 61000-4-39.
Particular considerations are devoted to the protection against radio-frequency emissions from
digital radiotelephones and other RF emitting devices.
NOTE 3 Test methods are defined in this part for evaluating the effect that electromagnetic radiation has on the
equipment concerned. The simulation and measurement of electromagnetic radiation is not adequately exact for
quantitative determination of effects. The test methods defined in this basic document have the primary objective of
establishing an adequate reproducibility of testing configuration and repeatability of test results at various test
facilities.
This document is an independent test method. It is not possible to use other test methods as
substitutes for claiming compliance with this document.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60050-161, International Electrotechnical Vocabulary (IEV) – Part 161: Electromagnetic
compatibility (available at www.electropedia.org)
3 Terms, definitions and abbreviated terms
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60050-161 and the
following apply.
– 10 – IEC 61000-4-3:2020 © IEC 2020
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1.1
amplitude modulation
AM
modulation in which the amplitude of a periodic carrier is a given function, generally linear, of
the instantaneous values of the modulating signal
[SOURCE: IEC 60050-702:2016, 702-06-17]
3.1.2
anechoic chamber
shielded enclosure which is lined with radio-frequency absorbers to reduce reflections from the
internal surfaces
3.1.3
fully anechoic chamber
shielded enclosure whose internal surfaces are totally lined with anechoic material
3.1.4
semi-anechoic chamber
shielded enclosure in which all surfaces except the metal floor are covered with material that
absorbs electromagnetic energy (i.e. RF absorber) in the frequency range of interest
3.1.5
modified semi-anechoic chamber
semi-anechoic chamber which has additional absorbers installed on the ground plane
3.1.6
antenna
that part of a radio transmitting or receiving system which is designed to provide the required
coupling between a transmitter or a receiver and the medium in which the radio wave
propagates
Note 1 to entry: In practice, the terminals of the antenna or the points to be considered as the interface between
the antenna and the transmitter or receiver should be specified.
Note 2 to entry: If a transmitter or receiver is connected to its antenna by a feed line, the antenna may be considered
to be a transducer between the guided waves of the feed line and the radiated waves in space.
[SOURCE: IEC 60050-712:1992, 712-01-01]
3.1.7
balun
device for transforming an unbalanced voltage to a balanced voltage or vice versa
[SOURCE: IEC 60050-161:1990 161-04-34]
3.1.8
common mode absorption device
CMAD
device that may be applied on cables leaving the test area in radiated immunity tests to damp
resonances on cables
IEC 61000-4-3:2020 © IEC 2020 – 11 –
3.1.9
continuous wave
CW
sinusoidal electromagnetic wave, the successive oscillations of which are identical under
steady-state conditions, which can be interrupted or modulated to convey information
3.1.10
electromagnetic wave
wave characterized by the propagation of a time-varying electromagnetic field
Note 1 to entry: An electromagnetic wave is produced by variations of electric charges or of electric currents
[SOURCE: IEC 60050-705:1995, 705-01-09]
3.1.11
far field
that region of the electromagnetic field of an antenna wherein the predominant components of
the field are those which represent a propagation of energy and wherein the angular field
distribution is essentially independent of the distance from the antenna
Note 1 to entry: In the far field region, all the components of the electromagnetic field decrease in inverse proportion
to the distance from the antenna.
Note 2 to entry: For a broadside antenna having a maximum overall dimension D which is large compared to the
wavelength λ, the far field region is commonly taken to exist at distances greater than 2D /λ, from the antenna in the
direction of maximum radiation.
[SOURCE: IEC 60050-712:1992, 712-02-02, modified – the word "region" has been removed
from the term]
3.1.12
field strength
magnitude of the electromagnetic field at a given point
[SOURCE: IEC 60050-705:1995, 705-08-31, modified – the rest of the definition after "given
point" has been deleted.]
3.1.13
frequency band
continuous set of frequencies lying between two specified limiting frequencies
Note 1 to entry: A frequency band is characterized by two values which define its position in the frequency spectrum,
for instance its lower and upper limiting frequencies.
[SOURCE: IEC 60050-702:1992, 702-01-02]
3.1.14
full illumination method
test method in which the EUT being tested fits completely within the uniform field area (UFA)
Note 1 to entry: This test method may be applied for all test frequencies.
3.1.15
human body-mounted equipment
equipment which is intended for use when attached to or held in close proximity to the human
body.
Note 1 to entry: This term includes hand-held devices which are carried by people while in operation (e.g. pocket
devices) as well as electronic aid devices and implants.

– 12 – IEC 61000-4-3:2020 © IEC 2020
3.1.16
intentional RF emitting device
device which radiates (transmits) an electromagnetic field intentionally
EXAMPLE: Digital mobile telephones and other radio devices.
3.1.17
intermodulation
interaction in non-linear device or transmission medium between the spectral components of
the input signal or signals producing new spectral components having frequencies equal to
linear combination with integral coefficients of the frequencies of the input spectral components
Note 1 to entry: Intermodulation can result from a single non-sinusoidal input signal or from several sinusoidal or
non-sinusoidal input signals applied to the same or to different inputs
[SOURCE: IEC 60050-161:2017, 161-06-20]
3.1.18
isotropic field probe
field sensor, whose detection properties are independent of direction of propagation and
polarization of an electromagnetic wave
[SOURCE: IEC 60050-731:1991, 731-03-08, modified – wording modified to apply to field
probe.]
3.1.19
maximum RMS value
highest short-term RMS value of a modulated RF signal during an observation time of one
modulation period
Note 1 to entry: The short-term RMS is evaluated over a single carrier cycle. For example, in Figure 1 b), the
maximum RMS voltage is: U = U /(2 × √2) = 1,8 V
maximum rms p-p
3.1.20
modulation factor
in linear amplitude modulation, the ratio, generally expressed as a percentage, of the difference
between the maximum and minimum amplitudes of the modulated signal to the sum of these
amplitudes, expressed as:
UU−
p-p,max p-p,min
m 100×
UU+
p-p,max p-p,min
SEE Table 2 and Figure 1.
[SOURCE: IEC 60050-702:1992, 702-06-19, modified – the formula has been added and the
note removed.]
3.1.21
non-constant envelope modulation
RF modulation scheme in which the amplitude of the carrier wave varies slowly in time
compared with the period of the carrier itself
EXAMPLE Conventional amplitude modulation and time division multiple access (TDMA).
3.1.22
partial illumination method
test method used when the EUT face cannot be illuminated at once using a single UFA
=
IEC 61000-4-3:2020 © IEC 2020 – 13 –
3.1.23
polarization
orientation of the electric field vector of a radiated field
3.1.24
reference ground plane
RGP
flat conductive surface that is at the same electric potential as the reference ground, which is
used as a common reference, and which contributes to a reproducible parasitic capacitance
with the surroundings of the equipment under test (EUT)
[SOURCE: IEC 60050-161:2014, 161-04-36, modified – notes have been deleted.]
3.1.25
shielded enclosure
screened room
mesh or sheet metallic housing designed expressly for the purpose of separating
electromagnetically the internal and the external environment
[SOURCE: IEC 60050-161:1990, 161-04-37]
3.1.26
time division multiple access
TDMA
multiple access technique in which the various terminals having access to a link are allotted
separate recurrent time intervals for transmission
[SOURCE: IEC 60050-725:1994, 725-14-12]
3.1.27
transceiver
transmitter-receiver
combination in a single unit of a radio transmitter and a radio receiver employing common circuit
components and usually the same antenna for both transmitting and receiving
[SOURCE: IEC 60050-713:1998, 713-08-02, modified – the note has been deleted.]
3.1.28
uniform field area
UFA
vertical plane in which field strength variations are acceptably small
SEE: 6.3.
3.2 Abbreviated terms
AE Auxillary equipment
AM Amplitude modulation
CMAD Common-mode absorption device
CW Continuous wave
DECT Digital enhanced cordless telecommunications
EM Elect
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

標準規格EN IEC 61000-4-3:2020は、放射電磁エネルギーに対する電気および電子機器の耐性要件に適用されるものであり、テストレベルと必要なテスト手順を確立しています。この文書の目的は、放射された無線周波数電磁場の影響を受けた際に、電気および電子機器の耐性を評価するための共通の基準を確立することです。IEC 61000のこの部分に記載されているテスト方法は、エレクトロニクス機器またはシステムが近接していないRF源からのRF電磁場に対してどのように耐性を持つかを評価する一貫した方法を提供します。 本標準は、テスト環境を第6条において明確に規定しており、特に製品委員会の使用を意図した基本的なEMC出版物としての位置付けを持っています。IEC製品委員会はこの耐性テスト標準の適用の有無を判断し、適用する場合にはテストレベルや性能基準を決定する責任を負っています。これは、TC 77およびその下位委員会が製品に対する特定の耐性テストの評価において製品委員会と協力することを準備していることを示しています。 さらに、テスト手法は、関係する機器に対する電磁放射の影響を評価するために定義されており、特にデジタル無線電話や他のRF放射デバイスからの無線周波数放出に対する保護に配慮されています。これらのテスト方法は、テスト構成の再現性と各テスト施設におけるテスト結果の再現性を確保することを主な目的としています。なお、他のテスト方法を本規格の遵守を主張する代替手段として使用することはできませんので、標準の独立性が強調されています。 今回の改定版では、複数のテスト信号を用いたテストが記載されているほか、EUTおよびケーブルの配置に関する追加情報が提供されており、上限周波数制限が撤廃されています。この変更は新たなサービスを考慮したものであり、耐性チェーンの電力増幅器の線形性をチェックするためのフィールドの特性付けも規定されています。全体として、EN IEC 61000-4-3:2020は、電磁適合性(EMC)の重要な基準であり、関連業界のニーズに応じた最新の技術的変更を反映しています。

The EN IEC 61000-4-3:2020 standard serves as a critical benchmark for evaluating the electromagnetic compatibility (EMC) of electrical and electronic equipment in relation to radiated, radio-frequency electromagnetic fields. Its scope is specifically tailored to outline the immunity requirements and the essential test procedures necessary for assessing the performance of such equipment when exposed to radiated electromagnetic energy, thereby ensuring that these systems maintain operational integrity in their intended environments. One of the principal strengths of this standard lies in its establishment of a consistent testing methodology, which facilitates the assessment of an equipment or system’s immunity against RF electromagnetic fields emitted from sources beyond close proximity to the equipment under test (EUT). This detailed approach is invaluable for manufacturers and product committees, as it provides a common reference point for standardizing immunity tests and results across the industry. The document underscores the importance of reproducibility in test configurations and consistency in test outcomes across various test facilities. This focus on reproducibility enhances the reliability of the test results, thus fostering confidence in the performance capabilities of the equipment evaluated against the standards outlined in IEC 61000-4-3:2020. Additionally, the 2020 edition introduces significant revisions that enhance the standard’s relevance. Notable updates include the integration of multi-signal testing methods, additional guidance on EUT and cable layout, as well as the removal of frequency limitations, which acknowledges the expanding landscape of RF services. These improvements broaden the applicability of the standard and make it more adaptable to the rapidly evolving technology sector. The document further specifies that it is not feasible to leverage alternative testing methods to claim compliance with its provisions, establishing its authority and ensuring that evaluations align strictly with the defined parameters. As a comprehensive EMC publication, it plays a vital role in guiding product committees in the application of these immunity tests and the establishment of appropriate test levels and performance criteria. Overall, the EN IEC 61000-4-3:2020 standard is a pivotal resource for ensuring the resilience and reliability of electronic systems against electromagnetic interference, making it a relevant and strength-driven guideline for industry practitioners involved in electromagnetic compatibility testing.

Le document SIST EN IEC 61000-4-3:2021 constitue une référence essentielle pour l'évaluation de la compatibilité électromagnétique (CEM) des équipements électriques et électroniques face aux champs électromagnétiques rayonnés. Ce standard, applicable aux exigences de robustesse des équipements contre l'énergie électromagnétique rayonnée, définit des niveaux d'essai ainsi que les procédures nécessaires pour assurer une évaluation cohérente de l'immunité de ces dispositifs. Parmi les forces de ce standard, on note la mise en place d'une méthode d'essai uniforme visant à garantir que l'équipement ou le système puisse résister à des champs électromagnétiques radiofréquence (RF) émis par des sources situées à distance. Cela est particulièrement pertinent dans un contexte où les interférences électromagnétiques peuvent provenir d'une multitude de dispositifs RF non proches. Le document établit également un cadre pour les environnements de test, permettant de reproduire les conditions d'essai de manière fiable. Un autre aspect de la norme est son rôle en tant que publication de base en matière de CEM, comme indiqué dans le Guide IEC 107. Ce guide souligne la responsabilité des comités de produits de l'IEC dans la détermination de l'application de cette norme d'essai d'immunité et des niveaux de test appropriés. Cette standardisation permet de garantir que les tests sont menés selon des critères de performance rigoureux, renforçant ainsi la fiabilité des résultats obtenus. Les évolutions techniques apportées par cette quatrième édition, qui remplace la troisième édition de 2006, sont également significatives. Parmi ces changements, on trouve la description des tests utilisant plusieurs signaux de test, l'ajout d'informations sur la disposition des équipements sous test (EUT) et des câbles, ainsi que la suppression de la limite de fréquence supérieure pour mieux intégrer les nouveaux services. La caractérisation du champ et la vérification de la linéarité des amplificateurs de puissance dans la chaîne d'immunité sont également spécifiées, garantissant ainsi que les méthodes de test sont adaptées aux technologies émergentes. En somme, la norme EN IEC 61000-4-3:2020 joue un rôle crucial dans l'établissement des exigences d'immunité électromagnétique, en fournissant une base solide et standardisée pour les essais des équipements, garantissant leur fiabilité et leur conformité aux défis contemporains en matière de compatibilité électromagnétique.

Die Norm EN IEC 61000-4-3:2020 behandelt die elektromagnetische Verträglichkeit (EMC) und legt wichtige Immunitätsanforderungen für elektrische und elektronische Geräte gegenüber radiierter elektromagnetischer Energie fest. Sie bietet eine klare Grundlage für die Evaluierung der Immunität von Geräten, wenn sie spezifischen Anforderungen an radiierte, hochfrequente elektromagnetische Felder ausgesetzt sind. Der Anwendungsbereich dieser Norm umfasst die Festlegung von Testniveaus und Verfahren, die für die Durchführung von Immunitätstests notwendig sind. Insbesondere wird ein konsistenter Prüfansatz beschrieben, der sicherstellt, dass die Systeme gegenüber RF-emittierenden Quellen, die nicht in unmittelbarer Nähe zum Gerät unter Prüfung (EUT) sind, ausreichend geschützt sind. Dies trägt entscheidend zur Verbesserung der Produktzuverlässigkeit und zur Minimierung von Störungen in der Funktionalität bei. Ein herausragendes Merkmal dieser Norm ist die detaillierte Beschreibung der Testmethoden und des Prüfstandards, die für unterschiedliche Prüfungen aufgestellt werden. Die Norm stellt sicher, dass die Tests reproduzierbar sind und die Testergebnisse an verschiedenen Prüfstandorten konsistent bleiben. Dies gewährleistet nicht nur die Integrität der Tests, sondern unterstützt auch Hersteller und Produktkommissionen bei der Entwicklung sicherer und normgerechter Produkte. Ein weiterer wichtiger Punkt ist die Zusammenarbeit von TC 77 und seinen Unterausschüssen mit Produktkommissionen, um die Relevanz und den Wert spezifischer Immunitätstests zu bewerten. Diese Kooperation fördert die Anpassungsfähigkeit der Norm an neue Entwicklungen in der Technologie und sichert die Aktualität der Testleitlinien im Hinblick auf neu auftretende RF-Quellen und Technologien. Die Überarbeitung im Vergleich zur vorherigen Auflage bringt signifikante technische Änderungen, darunter die Beschreibung von Tests mit multiplen Prüfsignalen, zusätzliche Informationen zur Anordnung des EUT und der Kabel, sowie die Aufhebung der oberen Frequenzbegrenzung, um neue Dienste zu berücksichtigen. Dadurch wird die Norm relevanter im Kontext moderner Geräte, die in einer zunehmend vernetzten Welt operieren müssen. Insgesamt stellt die EN IEC 61000-4-3:2020 ein essentielles Dokument in der Normenlandschaft dar, das die Grundlage für die Gewährleistung der elektromagnetischen Verträglichkeit von Produkten bildet und somit einen entscheidenden Beitrag zur Verbesserung der technischen Sicherheit und Qualität in der Industrie leistet.

SIST EN IEC 61000-4-3:2021 표준은 전자기 호환성(EMC) 분야에서 전파, 전파 주파수 전자기 필드 면역 시험을 다루고 있습니다. 이 표준의 주요 범위는 전자 및 전기 장비가 방사된 전자기 에너지에 대한 면역 요구 사항을 설정하여, 일정한 시험 수준과 필요한 시험 절차를 수립하는 것입니다. 이를 통해 전자 및 전기 장비가 방사된 전파 전자기 필드에 노출되었을 때의 면역성을 평가하기 위한 공통 참조 기준이 마련됩니다. 이 표준의 강점 중 하나는 RF 전자기 필드에 대한 일관된 면역성 평가 방법을 제시한다는 점입니다. 이는 EUT(시험 대상 장비)와 가까운 거리에서의 RF 소스와는 별개로, 먼 거리에서 발생하는 RF 전자기 필드의 영향을 평가하도록 설계되었습니다. 시험 환경에 대한 규정은 6항에서 명확히 제시되어 있어, 여러 테스트 시설에서 재현성과 결과의 반복성을 보장하는 데 중점을 두고 있습니다. 특히, 이 표준은 제품 위원회가 면역 시험 표준의 적용 여부를 결정하고, 적용 시 적절한 시험 수준과 성능 기준을 설정하는 책임이 있음을 명시하여, EMC 분야의 일관된 적용을 장려합니다. 또한, RF 전원 근처에서의 면역 시험에 대한 정의는 IEC 61000-4-39에서 다루고 있어, RF 방출 장치에 대한 보호를 위한 특별한 고려사항도 포함하고 있습니다. 이 문서의 기술적 수정은 이전 판과의 명확한 차별성을 제공하며, 다수의 시험 신호를 사용하는 시험 방법의 설명과 EUT 및 케이블 배치에 대한 추가 정보 제공, 새로운 서비스에 대한 고려를 위해 상한 주파수 제한을 제거한 점이 특징적입니다. 또한, 면역 체인의 전력 증폭기 선형성을 확인하는 과정도 명확히 규정되어 있어, 필드의 특성화에 대한 명확한 기준을 제시하고 있습니다. 따라서 SIST EN IEC 61000-4-3:2021 표준은 전자기 호환성 관련 산업에서 필수적인 문서로 자리잡고 있으며, 제품의 RF 전자기 필드 면역성을 평가하는 데 중요한 역할을 하고 있습니다. 이 표준을 통해 사용자는 정확하고 신뢰할 수 있는 시험을 수행하여, 제품이 요구되는 EMC 기준을 충족하는지를 검증할 수 있습니다.