EN 61076-3-114:2009
(Main)Connectors for electronic equipment - Product requirements - Part 3-114: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 11 related to IEC 61076-3-106 - Bayonet coupling type
Connectors for electronic equipment - Product requirements - Part 3-114: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 11 related to IEC 61076-3-106 - Bayonet coupling type
IEC 61076-3-114:2009 covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-5, and IEC 60603-7-7 to IP65 and IP67 ratings, according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms and a variety of different mounting configurations and termination types which are detailed in IEC 60603-7.
Steckverbinder für elektronische Einrichtungen - Produktanforderungen - Teil 3-114: Rechteckige Steckverbinder - Bauartspezifikation für Schutzgehäuse für die Anwendung mit 8-poligen geschirmten und ungeschirmten Steckverbindern für Frequenzen bis 600 MHz für industrielle Umgebungen zur Aufnahme der Schnittstelle der Reihe IEC 60603-7 - Ausführung 11 zu IEC 61076-3-106 - Bajonettausführung
Connecteurs pour équipement électroniques - Exigences de produits - Partie 3-114: Connecteurs rectangulaires - Spécification particulière pour boîtiers de protection utilisés avec des connecteurs blindés et non blindés à 8 voies pour des fréquences inférieures ou égales à 600 MHz dans des environnements industriels incorporant l’interface série CEI 60603-7 - Variante 11 liée à la CEI 61076-3-106 - Type d’accouplement à baïonnette
La CEI 61076-3-114:2009 couvre les boîtiers de protection pour améliorer les connecteurs 8 voies blindés et non blindés existants utilisant l'interface décrite dans la CEI 60603-7-2, la CEI 60603-7-3, la CEI 60603-7-4, la CEI 60603-7-5 et la CEI 60603-7-7 pour les caractéristiques IP65 et IP67 conformément à la CEI 60529, utilisés dans les environnements industriels. Les boîtiers couvrent différents mécanismes de verrouillage et une variété de configurations de montage et de types de sortie qui sont détaillés dans la CEI 60603-7.
Konektorji za elektronsko opremo - Zahteve za izdelek - 3-114. del: Pravokotni konektorji - Zaščitna ohišja za 8-redne zaslonjene in nezaslonjene konektorje za frekvence do 600 MHz, za industrijska okolja, z vgrajenim vmesnikom po IEC 60603-7 - Različica 11 v povezavi z IEC 61076-3-106 - Tip z bajonetnim sklapljanjem (IEC 61076-3-114:2009)
General Information
- Status
- Published
- Publication Date
- 06-Aug-2009
- Withdrawal Date
- 30-Jun-2012
- Technical Committee
- CLC/SR 48B - Connectors
- Drafting Committee
- IEC/SC 48B - IEC_SC_48B
- Parallel Committee
- IEC/SC 48B - IEC_SC_48B
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 07-Aug-2009
- Completion Date
- 07-Aug-2009
Overview
EN 61076-3-114:2009 (IEC 61076-3-114:2009) specifies detail requirements for protective housings used to upgrade existing 8‑way shielded and unshielded rectangular connectors (IEC 60603‑7 series interface) to industrial environmental protection levels IP65 and IP67 (per IEC 60529). The standard addresses the Variant 11 (bayonet coupling) related to IEC 61076‑3‑106 and applies to connectors for data transmission up to 600 MHz in industrial environments.
Key topics and technical requirements
- Scope and interface compatibility
- Housings designed for IEC 60603‑7 series 8‑way connector interfaces (shielded/unshielded).
- Variant 11 bayonet coupling type for fixed and free connector configurations.
- Environmental protection
- Sealing and enclosure requirements to achieve IP65 / IP67 ingress protection ratings.
- Mechanical and dimensional details
- Dimensional drawings and mounting information for fixed and free connectors, caps, and bayonet coupling.
- Termination and mounting options aligned with IEC 60603‑7.
- Electrical and transmission characteristics
- Requirements covering clearance/creepage, voltage proof, contact resistance, input‑to‑output resistance and resistance unbalance.
- Derating guidance and mating cycles with power applied (connector life and performance).
- Testing and qualification
- Comprehensive test schedule: climatic categories, dynamic and mechanical tests, contact resistance measurement arrangements, and preconditioning.
- Test groups and procedures (P, AP, BP, CP, DP, EP) to verify sealing, mechanical integrity and transmission performance.
- Accessories
- Caps for fixed and free connector variants and details of their dimensions and sealing features.
Practical applications and users
EN 61076-3-114 is valuable for:
- Connector and housing manufacturers designing industrial-grade rectangular connector housings with bayonet coupling.
- Panel builders and system integrators who need to upgrade standard 8‑way connectors to IP65/IP67 environmental protection.
- Automation and industrial Ethernet designers specifying connectors for sensors, actuators, field devices and control cabinets operating up to 600 MHz.
- Product engineers and procurement teams seeking compliance and test evidence for ruggedised connector assemblies in harsh industrial environments.
Related standards (for specification and testing)
- IEC 60603‑7 series (8‑way connector interfaces)
- IEC 60529 (IP Code for degrees of protection)
- IEC 61076‑3‑106 (related variant specifications)
- IEC 60068 / IEC 60512 series (environmental and connector test methods)
Using EN 61076-3-114:2009 helps ensure compatible, tested protective housings that deliver IP65/IP67 protection and reliable electrical and mechanical performance for 8‑way industrial connector assemblies.
Frequently Asked Questions
EN 61076-3-114:2009 is a standard published by CLC. Its full title is "Connectors for electronic equipment - Product requirements - Part 3-114: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 11 related to IEC 61076-3-106 - Bayonet coupling type". This standard covers: IEC 61076-3-114:2009 covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-5, and IEC 60603-7-7 to IP65 and IP67 ratings, according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms and a variety of different mounting configurations and termination types which are detailed in IEC 60603-7.
IEC 61076-3-114:2009 covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-5, and IEC 60603-7-7 to IP65 and IP67 ratings, according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms and a variety of different mounting configurations and termination types which are detailed in IEC 60603-7.
EN 61076-3-114:2009 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 61076-3-114:2009 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-oktober-2009
.RQHNWRUML]DHOHNWURQVNRRSUHPR=DKWHYH]DL]GHOHNGHO3UDYRNRWQL
NRQHNWRUML=DãþLWQDRKLãMD]DUHGQH]DVORQMHQHLQQH]DVORQMHQHNRQHNWRUMH]D
IUHNYHQFHGR0+]]DLQGXVWULMVNDRNROMD]YJUDMHQLPYPHVQLNRPSR,(&
5D]OLþLFDYSRYH]DYL],(&7LS]EDMRQHWQLPVNODSOMDQMHP
,(&
Connectors for electronic equipment - Product requirements - Part 3-114: Rectangular
connectors - Protective housings for use with 8-way shielded and unshielded connectors
for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7
series interface - Variant 11 related to IEC 61076-3-106 - Bayonet coupling type (IEC
61076-3-114:2009)
Steckverbinder für elektronische Einrichtungen - Produktanforderungen - Teil 3-114:
Rechteckige Steckverbinder - Schutzgehäuse für die Anwendung mit 8-poligen
geschirmten und ungeschirmten Steckverbindern für Frequenzen bis 600 MHz für
industrielle Umgebungen zur Aufnahme der Schnittstelle der Reihe IEC 60603-7 -
Ausführung 11 zu IEC 61076-3-106 - Bajonettausführung (IEC 61076-3-114:2009)
Connecteurs pour équipement électroniques - Exigences de produits - Partie 3-114:
Connecteurs rectangulaires - Boîtiers de protection utilisés avec des connecteurs blindés
et non blindés 8 voies pour des fréquences inférieures ou égales à 600 MHz dans des
environnements industriels incorporant l’interface série 60603-7 - Variante 11 liée à la
CEI 61076-3-106 - Type d’accouplement à baïonnette (CEI 61076-3-114:2009)
Ta slovenski standard je istoveten z: EN 61076-3-114:2009
ICS:
31.220.10 9WLþLLQYWLþQLFHNRQHNWRUML Plug-and-socket devices.
Connectors
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 61076-3-114
NORME EUROPÉENNE
August 2009
EUROPÄISCHE NORM
ICS 31.220.10
English version
Connectors for electronic equipment -
Product requirements -
Part 3-114: Rectangular connectors -
Detail specification for protective housings for use with 8-way shielded
and unshielded connectors for frequencies up to 600 MHz for industrial environments
incorporating the IEC 60603-7 series interface -
Variant 11 related to IEC 61076-3-106 -
Bayonet coupling type
(IEC 61076-3-114:2009)
Connecteurs Steckverbinder
pour équipement électroniques - für elektronische Einrichtungen -
Exigences de produits - Produktanforderungen -
Partie 3-114: Connecteurs rectangulaires - Teil 3-114: Rechteckige Steckverbinder -
Spécification particulière pour boîtiers Bauartspezifikation für Schutzgehäuse
de protection utilisés avec für die Anwendung mit 8-poligen geschirmten
des connecteurs blindés et non blindés und ungeschirmten Steckverbindern
à 8 voies pour des fréquences für Frequenzen bis 600 MHz für industrielle
inférieures ou égales à 600 MHz dans des Umgebungen zur Aufnahme der Schnittstelle
environnements industriels incorporant der Reihe IEC 60603-7 -
l’interface série CEI 60603-7 - Ausführung 11 zu IEC 61076-3-106 -
Variante 11 liée à la CEI 61076-3-106 - Bajonettausführung
Type d’accouplement à baïonnette (IEC 61076-3-114:2009)
(CEI 61076-3-114:2009)
This European Standard was approved by CENELEC on 2009-07-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: Avenue Marnix 17, B - 1000 Brussels
© 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61076-3-114:2009 E
Foreword
The text of document 48B/1995/FDIS, future edition 1 of IEC 61076-3-114, prepared by SC 48B,
Connectors, of IEC TC 48, Electromechanical components and mechanical structures for electronic
equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as
EN 61076-3-114 on 2009-07-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
(dop) 2010-04-01
national standard or by endorsement
– latest date by which the national standards conflicting
(dow) 2012-07-01
with the EN have to be withdrawn
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61076-3-114:2009 was approved by CENELEC as a European
Standard without any modification.
__________
- 3 - EN 61076-3-114:2009
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
IEC 60050-581 2008 International Electrotechnical Vocabulary - -
(IEV) -
Part 581: Electromechanical components for
electronic equipment
1) 2)
IEC 60068-1 - Environmental testing - EN 60068-1 1994
Part 1: General and guidance
1) 2)
IEC 60068-2-14 - Environmental testing - EN 60068-2-14 2009
Part 2-14: Tests - Test N: Change of
temperature
1) 2)
IEC 60068-2-30 - Environmental testing - EN 60068-2-30 2005
Part 2-30: Tests - Test Db: Damp heat, cyclic
(12 h + 12 h cycle)
1) 2)
IEC 60512-1 - Connectors for electronic equipment - Tests EN 60512-1 2001
and measurements -
Part 1: General
1) 2)
IEC 60512-1-100 - Connectors for electronic equipment - Tests EN 60512-1-100 2006
and measurements -
Part 1-100: General - Applicable publications
1) 2)
IEC 60529 - Degrees of protection provided by enclosures EN 60529 1991
(IP Code) + corr. May 1993
1)
IEC 60603-7 - Connectors for electronic equipment - - -
Part 7: Detail specification for 8-way,
unshielded, free and fixed connectors
1)
IEC 60603-7-2 - Connectors for electronic equipment - - -
Part 7-2: Detail specification for 8-way,
unshielded, free and fixed connectors, for data
transmissions with frequencies up to 100 MHz
1)
IEC 60603-7-3 - Connectors for electronic equipment - - -
Part 7-3: Detail specification for 8-way,
shielded, free and fixed connectors, for data
transmission with frequencies up to 100 MHz
1) 2)
IEC 60603-7-4 - Connectors for electronic equipment - EN 60603-7-4 2005
Part 7-4: Detail specification for 8-way,
unshielded, free and fixed connectors, for data
transmissions with frequencies up to 250 MHz
1)
Undated reference.
2)
Valid edition at date of issue.
Publication Year Title EN/HD Year
1)
IEC 60603-7-5 - Connectors for electronic equipment - - -
Part 7-5: Detail specification for 8-way,
shielded, free and fixed connectors, for data
transmissions with frequencies up to 250 MHz
1) 2)
IEC 60603-7-7 - Connectors for electronic equipment - EN 60603-7-7 2006
Part 7-7: Detail specification for 8-way,
shielded, free and fixed connectors for data
transmission with frequencies up to 600 MHz
1) 2)
IEC 60664-1 - Insulation coordination for equipment within EN 60664-1 2007
low-voltage systems -
Part 1: Principles, requirements and tests
IEC 61076-1 2006 Connectors for electronic equipment - EN 61076-1 2006
Product requirements -
Part 1: Generic specification
IEC 61156 Series Multicore and symmetrical pair/quad cables - -
for digital communications
1)
IEC 61156-2 - Multicore and symmetrical pair/quad cables - -
for digital communications -
Part 2: Horizontal floor wiring - Sectional
specification
1)
IEC 61156-3 - Multicore and symmetrical pair/quad cables - -
for digital communications -
Part 3: Work area cable - Sectional
specification
1)
IEC 61156-4 - Multicore and symmetrical pair/quad cables - -
for digital communications -
Part 4: Riser cables - Sectional specification
IEC 61076-3-114 ®
Edition 1.0 2009-04
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electronic equipment – Product requirements –
Part 3-114: Rectangular connectors – Detail specification for protective housings
for use with 8-way shielded and unshielded connectors for frequencies up to
600 MHz for industrial environments incorporating the IEC 60603-7 series
interface – Variant 11 related to IEC 61076-3-106 – Bayonet coupling type
Connecteurs pour équipements électroniques – Exigences de produit –
Partie 3-114: Connecteurs rectangulaires – Spécification particulière pour
boîtiers de protection utilisés avec des connecteurs blindés et non blindés
à 8 voies pour des fréquences inférieures ou égales à 600 MHz dans des
environnements industriels incorporant l’interface série CEI 60603-7 –
Variante 11 liée à la CEI 61076-3-106 – Type d’accouplement à baïonnette
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
T
CODE PRIX
ICS 31.220.10 ISBN 2-8318-1038-6
– 2 – 61076-3-114 © IEC:2009
CONTENTS
FOREWORD.4
INTRODUCTION.6
1 General data .7
1.1 Scope.7
1.2 Normative references .7
2 Terms and definitions .8
3 Dimensional information .8
3.1 Common features .8
3.2 General .9
3.3 Contact arrangement of all connector types.9
3.4 IP65 and IP67 sealing .9
3.5 Industrial IEC 60603-7 variant 11 – Bayonet coupling.9
3.5.1 Industrial IEC 60603-7 variant 11, fixed connectors .9
3.5.2 Industrial IEC 60603-7 variant 11, free connectors .10
3.6 Termination and mounting information.11
3.7 General .11
3.8 Mounting information for variant 11, fixed connector.11
3.9 Cap for fixed connector .12
3.10 Cap for free connector.13
4 Gauges .13
4.1 Connectors, IEC 60603-7 interface.13
5 Characteristics .13
5.1 Climatic category.13
5.2 Electrical .14
5.2.1 Clearance and creepage distances.14
5.2.2 Voltage proof.14
5.2.3 Current-derating diagram.14
5.2.4 Mating cycles with power applied.15
5.2.5 Initial contact resistance .15
5.2.6 Input-to-output resistance.15
5.2.7 Resistance unbalance .15
5.2.8 Initial insulation resistance .16
5.3 Transmission characteristics .16
5.3.1 General .16
5.3.2 Mechanical operation .16
5.3.3 Effectiveness of connector coupling devices transversal.16
5.3.4 Effectiveness of connector coupling devices.16
5.3.5 Separation and engagement forces .16
6 Test schedule.16
6.1 General .16
6.2 Test procedures and measuring methods .17
6.3 Preconditioning .17
6.4 Wiring and mounting of specimens .17
6.4.1 Wiring.17
6.4.2 Mounting .17
6.5 Arrangement for contact resistance test .17
61076-3-114 © IEC:2009 – 3 –
6.6 Arrangement for dynamic stress tests (test phase AP2).17
6.7 Basic (minimum) test schedule .17
6.8 Full test schedule .17
6.8.1 Test preliminary group P.18
6.8.2 Test group P.18
6.8.3 Test group AP .19
6.8.4 Test group BP .20
6.8.5 Test group CP .21
6.8.6 Test group DP .21
6.8.7 Test group EP .21
Bibliography.22
Figure 1 – Variant 11, fixed connector .9
Figure 2 – Variant 11, free connector.10
Figure 3 – Variant 11 mounting .11
Figure 4 – Variant 11 cap for fixed connector.12
Figure 5 – Variant 11 cap for free connector .13
Figure 6 – Connector derating diagram .15
Table 1 – Dimensions of fixed connector, variant 11 .10
Table 2 – Dimensions of free connector, variant 11.11
Table 3 – Mounting information.11
Table 4 – Dimensions of cap for fixed connector variant 11.12
Table 5 – Dimensions of cap for free connector variant 11.13
Table 6 – Climatic categories – Selected values for environmental performance level A .14
Table 7 – .14
Table 8 – Test group P .18
Table 9 – Test group AP – Dynamic/climatic .19
Table 10 – Test group BP – Mechanical.20
Table 11 – Test group CP – Continuity.21
– 4 – 61076-3-114 © IEC:2009
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
CONNECTORS FOR ELECTRONIC EQUIPMENT –
PRODUCT REQUIREMENTS –
Part 3-114: Rectangular connectors – Detail specification for protective
housings for use with 8-way shielded and unshielded connectors
for frequencies up to 600 MHz for industrial environments
incorporating the IEC 60603-7 series interface –
Variant 11 related to IEC 61076-3-106 –
Bayonet coupling type
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national Electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
International Standard IEC 61076-3-114 has been prepared by subcommittee 48B:
Connectors, of IEC technical committee 48: Electromechanical components and mechanical
structures for electronic equipment.
This International Standard cancels and replaces IEC/PAS 61076-3-114 (2005).
61076-3-114 © IEC:2009 – 5 –
The text of this standard is based on the following documents:
FDIS Report on voting
48B/1995/FDIS 48B/2013/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
A list of all parts of IEC 61076 series, under the general title Connectors for electronic
equipment – Product requirements, can be found on the IEC website.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under http://webstore.iec.ch in the
data related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
– 6 – 61076-3-114 © IEC:2009
INTRODUCTION
Attention is drawn to the possibility that some of the elements of this document may be the
subject of patent rights. IEC shall not be held responsible for identifying any or all such patent
rights.
The International Electrotechnical Commission (IEC) draws attention to the fact that it is
claimed that compliance with this document may involve the use of a patent concerning
1)
Amphenol .
IEC takes no position concerning the evidence, validity and scope of this patent right.
The holder of this patent right has assured the IEC that he/s
...