EN 50053-1:1987
(Main)Requirements for the selection, installation and use of electrostatic spraying equipment for flammable materials - Part 1: Hand-held electrostatic paint spray guns with an energy limit of 0,24 mJ and their associated apparatus
Requirements for the selection, installation and use of electrostatic spraying equipment for flammable materials - Part 1: Hand-held electrostatic paint spray guns with an energy limit of 0,24 mJ and their associated apparatus
This European Standard gives requirements for the selection, installation and safe use of hand-held electrostatic spray guns with an energy limit of 0,24 mJ and their associated apparatus complying with EN 50 050, which may cause an explosive atmosphere when spraying flammable liquid. This European Standard considers only the hazards that are specific to the electrostatic characteristics of the electrostatic spraying process. For other aspects such as classification of hazardous areas (e.g. classification into zones), selection, installation and use of electrical equipment in hazardous areas, health hazards (e.g. toxic and skin effects, electric shock), cleaning of paint spraying areas, fire hazard from external sources, storage and handling of flammable liquids, national regulations apply
Bestimmungen für die Auswahl, Errichtung und Anwendung elektrostatischer Sprühanlagen für brennbare Sprühstoffe - Teil 1: Elektrostatische Handsprüheinrichtungen für flüssige Sprühstoffe mit einer Energiegrenze von 0,24 mJ sowie Zubehör
Règles de sélection, d'installation et d'utilisation d'un équipement de projection électrostatique pour produits inflammables - Partie 1: Pistolets manuels de projection électrostatique de peinture avec une énergie limite de 0,24 mJ et leur matériel associé
Requirements for the selection, installation and use of electrostatic spraying equipment for flammable spraying materials - Part 1: Hand held electrostatic paint spray guns with an energy limit of O.24 mJ and their associated apparatus
General Information
- Status
- Withdrawn
- Publication Date
- 03-Mar-1987
- Withdrawal Date
- 31-Mar-2004
- Technical Committee
- CLC/TC 31 - Electrical apparatus for explosive atmospheres - General requirements
- Drafting Committee
- CLC/SC 31-8 - Electrostatic painting and finishing equipment
- Parallel Committee
- IEC/TC 31 - Electrical apparatus for potentially explosive atmospheres
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Apr-2004
- Completion Date
- 01-Apr-2004
- Directive
- Not Harmonized79/196/EEC - Electrical apparatus for use in explosive atmospheres using certain modes of protectionOJ Ref: L 257, L 257, L 257, L 257, L 257, L 257, L 257, L OJ Date: 20-Sep-1997
Not Harmonized97/53/EC - Electrical apparatus for use in explosive atmospheres using certain modes of protectionOJ Ref: L 257, L 257, L 257, L 257, L 257, L 257, L 257, L OJ Date: 20-Sep-1997
Relations
- Referred By
EN 1953:1998+A1:2009 - Atomising and spraying equipment for coating materials - Safety requirements - Effective Date
- 09-Feb-2026
Frequently Asked Questions
EN 50053-1:1987 is a standard published by CLC. Its full title is "Requirements for the selection, installation and use of electrostatic spraying equipment for flammable materials - Part 1: Hand-held electrostatic paint spray guns with an energy limit of 0,24 mJ and their associated apparatus". This standard covers: This European Standard gives requirements for the selection, installation and safe use of hand-held electrostatic spray guns with an energy limit of 0,24 mJ and their associated apparatus complying with EN 50 050, which may cause an explosive atmosphere when spraying flammable liquid. This European Standard considers only the hazards that are specific to the electrostatic characteristics of the electrostatic spraying process. For other aspects such as classification of hazardous areas (e.g. classification into zones), selection, installation and use of electrical equipment in hazardous areas, health hazards (e.g. toxic and skin effects, electric shock), cleaning of paint spraying areas, fire hazard from external sources, storage and handling of flammable liquids, national regulations apply
This European Standard gives requirements for the selection, installation and safe use of hand-held electrostatic spray guns with an energy limit of 0,24 mJ and their associated apparatus complying with EN 50 050, which may cause an explosive atmosphere when spraying flammable liquid. This European Standard considers only the hazards that are specific to the electrostatic characteristics of the electrostatic spraying process. For other aspects such as classification of hazardous areas (e.g. classification into zones), selection, installation and use of electrical equipment in hazardous areas, health hazards (e.g. toxic and skin effects, electric shock), cleaning of paint spraying areas, fire hazard from external sources, storage and handling of flammable liquids, national regulations apply
EN 50053-1:1987 has the following relationships with other standards: It is inter standard links to EN 1953:1998+A1:2009. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 50053-1:1987 is associated with the following European legislation: EU Directives/Regulations: 79/196/EEC, 97/53/EC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 50053-1:1987 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-1996
Requirements for the selection, installation and use of electrostatic spraying
equipment for flammable spraying materials - Part 1: Hand held electrostatic paint
spray guns with an energy limit of O.24 mJ and their associated apparatus
Requirements for the selection, installation and use of electrostatic spraying equipment
for flammable materials -- Part 1: Hand-held electrostatic paint spray guns with an
energy limit of 0,24 mJ and their associated apparatus
Bestimmungen für die Auswahl, Errichtung und Anwendung elektrostatischer
Sprühanlagen für brennbare Sprühstoffe -- Teil 1: Elektrostatische
Handsprüheinrichtungen für flüssige Sprühstoffe mit einer Energiegrenze von 0,24 mJ
sowie Zubehör
Règles de sélection, d'installation et d'utilisation d'un équipement de projection
électrostatique pour produits inflammables -- Partie 1: Pistolets manuels de projection
électrostatique de peinture avec une énergie limite de 0,24 mJ et leur matériel associé
Ta slovenski s
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...