EN 50267-2-1:1998
(Main)Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas
Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas
EN 50267-2-1 specifies the procedure for the determination of the amount of halogen acid gas, other than hydrofluoric acid, evolved during the combustion of compounds based on halogenated polymers, and compounds containing halogenated additives, taken from cable constructions. For reasons of accuracy this method is not recommended for use where the amount of halogen acid evolved is less than 5mg/g of the sample taken. This method is not suitable for defining comppounds or materials described as zero-halogen or halogen-free. For such compounds or materials, and all compounds or materials containing less than 5 mg/g halogen acid equivalent, it is recommended to use the method specified in EN 50267-2-2
Allgemeine Prüfverfahren für das Verhalten von Kabeln und isolierten Leitungen im Brandfall - Prüfung der bei der Verbrennung der Werkstoffe von Kabeln und isolierten Leitungen entstehenden Gase - Teil 2-1: Prüfverfahren - Bestimmung des Gehaltes an Halogenwasserstoffsäure
Méthodes d'essai communes aux câbles soumis au feu - Essais sur les gaz émis lors de la combustion d'un matériau prélevé sur un câble - Partie 2-1: Procédures - Détermination de la quantité de gaz acides halogénés
Prescrit une méthode pour la détermination de la quantité de gaz acide halogéné, autre que l'acide fluorhydrique, émis durant la combustion de mélanges à base de polymère halogénés et de mélanges contenant des additifs halogénés prélevés sur un câble. L'utilisation de cete méthode n'est pas recommandée lorsque la quantité d'acide halogéné émis est inférieure à 5 mg/g d'échantillon prélevé. A le statut d'une publication fondamentale de sécurité conformément au Guide 104.
Splošne metode za preskušanje kablov v požarnih razmerah - Ugotavljanje nastajanja plinov pri gorenju kabelskih materialov - 2-1. del: Postopki - Ugotavljanje količine plina halogenske kisline
General Information
- Status
- Withdrawn
- Publication Date
- 16-Jun-1998
- Withdrawal Date
- 29-Feb-2000
- Technical Committee
- CLC/TC 20 - Electric cables
- Drafting Committee
- IEC/TC 20 - IEC_TC_20
- Parallel Committee
- IEC/TC 20 - IEC_TC_20
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 27-Jan-2017
- Due Date
- 27-Jan-2017
- Completion Date
- 27-Jan-2017
Relations
- Effective Date
- 29-Jan-2023
- Effective Date
- 29-Jan-2023
Get Certified
Connect with accredited certification bodies for this standard

NSF International
Global independent organization facilitating standards development and certification.

UL Solutions
Global safety science company with testing, inspection and certification.
CEPREI Certification Center (Guangzhou Saibao)
Pioneer of third-party certification, subsidiary of Electronic Fifth Research Institute.
Sponsored listings
Frequently Asked Questions
EN 50267-2-1:1998 is a standard published by CLC. Its full title is "Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas". This standard covers: EN 50267-2-1 specifies the procedure for the determination of the amount of halogen acid gas, other than hydrofluoric acid, evolved during the combustion of compounds based on halogenated polymers, and compounds containing halogenated additives, taken from cable constructions. For reasons of accuracy this method is not recommended for use where the amount of halogen acid evolved is less than 5mg/g of the sample taken. This method is not suitable for defining comppounds or materials described as zero-halogen or halogen-free. For such compounds or materials, and all compounds or materials containing less than 5 mg/g halogen acid equivalent, it is recommended to use the method specified in EN 50267-2-2
EN 50267-2-1 specifies the procedure for the determination of the amount of halogen acid gas, other than hydrofluoric acid, evolved during the combustion of compounds based on halogenated polymers, and compounds containing halogenated additives, taken from cable constructions. For reasons of accuracy this method is not recommended for use where the amount of halogen acid evolved is less than 5mg/g of the sample taken. This method is not suitable for defining comppounds or materials described as zero-halogen or halogen-free. For such compounds or materials, and all compounds or materials containing less than 5 mg/g halogen acid equivalent, it is recommended to use the method specified in EN 50267-2-2
EN 50267-2-1:1998 is classified under the following ICS (International Classification for Standards) categories: 13.220.40 - Ignitability and burning behaviour of materials and products; 29.060.20 - Cables. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 50267-2-1:1998 has the following relationships with other standards: It is inter standard links to EN 60754-2:2014, EN 60754-1:2014. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 50267-2-1:1998 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 50267-2-1:1998 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-julij-1999
6SORãQHPHWRGH]DSUHVNXãDQMHNDEORYYSRåDUQLKUD]PHUDK8JRWDYOMDQMH
QDVWDMDQMDSOLQRYSULJRUHQMXNDEHOVNLKPDWHULDORYGHO3RVWRSNL
8JRWDYOMDQMHNROLþLQHSOLQDKDORJHQVNHNLVOLQH
Common test methods for cables under fire conditions - Tests on gases evolved during
combustion of materials from cables - Part 2-1: Procedures - Determination of the
amount of halogen acid gas
Allgemeine Prüfverfahren für das Verhalten von Kabeln und isolierten Leitungen im
Brandfall - Prüfung der bei der Verbrennung der Werkstoffe von Kabeln und isolierten
Leitungen entstehenden Gase - Teil 2-1: Prüfverfahren - Bestim
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...