Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables

This document specifies requirements for, and constructions and dimensions of, single core cables, rated voltage U0 / U = 300 /300 V, of the following type: Unscreened (0,5 mm2 to 2,5 mm2 single core) These cables are rated for occasional thermal stresses causing ageing equivalent to continuous operational life at a temperature of 105 °C. For standard cables, this is determined by the acceptance test defined in EN 50305, using accelerated long-term (5 000 h) thermal ageing indicating a 125 °C/20 000 h temperature index. If the customer were to require lifetime predictions, this would be demonstrated based on the temperature index of the product as supplied by the manufacturer. The maximum temperature for short circuit conditions is 160 °C based on duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Level 3 of EN 45545 1 and EN 45545 2. EN 50306-2:2020 is expected to be used in conjunction with EN 50306-1:2020, General requirements.

Bahnanwendungen - Kabel und Leitungen für Schienenfahrzeuge mit verbessertem Verhalten im Brandfall - Reduzierte Isolierwanddicken - Teil 2: Einadrige Kabel und Leitungen

Dieses Dokument legt Anforderungen, Aufbau und Maße von einadrigen Kabeln und Leitungen mit einer Nennspannung von U0/U = 300/300 V für folgende Bauarten fest: Ungeschirmt (0,5 mm2 bis 2,5 mm2 einadrig). Diese Kabel und Leitungen sind für gelegentliche Wärmebeanspruchung ausgelegt, die zu einer Werkstoffalterung führt, die dem des Dauerbetriebs bei 105 °C entspricht. Für Standardkabel und -leitungen wird dies durch die in EN 50305 festgelegte Prüfung nachgewiesen, wobei eine beschleunigte thermische Langzeitalterung (5 000 h) verwendet wird, die einen Temperaturindex von 125 °C / 20 000 h anzeigt. Würde der Kunde Lebensdauervorhersagen verlangen, würde dies anhand des vom Hersteller gelieferten Temperaturindex des Produkts demonstriert werden. Die höchste zulässige Temperatur unter Kurzschlussbedingungen, bezogen auf eine Dauer von 5 s, beträgt 160 °C. Diese Kabel und Leitungen verfügen im Brandfall über besondere Leistungsmerkmale hinsichtlich der zulässigen Brandfortleitung (Flammenausbreitung) und der zulässigen Entwicklung von Rauch und toxischen Gasen. Diese Anforderungen wurden festgelegt, um zu ermöglichen, dass die Kabel und Leitungen die Anforderungen der Gefährdungsstufe 3 nach EN 45545-1 und EN 45545-2 erfüllen. EN 50306-2:2020 wird voraussichtlich in Verbindung mit EN 50306-1:2020, „Allgemeine Anforderungen“, verwendet werden.

Applications ferroviaires - Câbles pour matériel roulant ferroviaire ayant des performances particulières de comportement au feu - Isolation mince - Partie 2: Câbles monoconducteurs

Le présent document définit les exigences constructives et dimensionnelles des câbles monoconducteurs, de tension assignée U0 / U = 300 V/300 V, du type suivant: Non blindé (conducteur de 0,5 mm2 à 2,5 mm2) Ces câbles sont conçus pour résister à des contraintes thermiques occasionnelles provoquant un vieillissement thermique équivalent à celui résultant d’un fonctionnement continu à 105 °C. Pour les câbles normalisés, cette température est déterminée par l’essai d’acceptation décrit dans l’EN 50305, qui consiste à appliquer un vieillissement thermique accéléré de longue durée (5 000 h) indiquant un indice de température de 125 °C/20 000 h. Si le client exigeait des prédictions de durée de vie, ces prédictions seraient fondées sur l’indice de température du produit tel que fourni par le fabricant. La température maximale admissible en cas de court-circuit est de 160 °C pendant 5 s. Lorsqu'ils sont soumis au feu, les câbles présentent des caractéristiques de performance particulières quant aux valeurs maximales admissibles relatives à la propagation de la flamme et l'émission de fumées et de gaz toxiques. Ces exigences permettent aux câbles de satisfaire au niveau de risque 3 de l’EN 45545-1 et de l’EN 45545-2. L’EN 50306-2:2020 est prévu pour être utilisée conjointement avec l’EN 50306-1:2020, Exigences générales.

Železniške naprave - Kabli v železniških vozilih s posebno požarno odpornostjo - Tanka stena - 2. del: Enožilni kabli

General Information

Status
Published
Publication Date
19-Mar-2020
Withdrawal Date
29-Dec-2022
Technical Committee
Drafting Committee
Current Stage
6060 - Document made available - Publishing
Start Date
20-Mar-2020
Due Date
04-Dec-2020
Completion Date
20-Mar-2020

Relations

Buy Standard

Standard
EN 50306-2:2020
English language
17 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 50306-2:2020
01-junij-2020
Nadomešča:
SIST EN 50306-2:2003
Železniške naprave - Kabli v železniških vozilih s posebno požarno odpornostjo -
Tanka stena - 2. del: Enožilni kabli
Railway applications - Railway rolling stock cables having special fire performance - Thin
wall - Part 2: Single core cables
Bahnanwendungen - Kabel und Leitungen für Schienenfahrzeuge mit verbessertem
Verhalten im Brandfall - Reduzierte Isolierwanddicken - Teil 2: Einadrige Kabel und
Leitungen
Applications ferroviaires - Câbles pour matériel roulant ferroviaire ayant des
performances particulières de comportement au feu - Isolation mince - Partie 2: Câbles
monoconducteurs
Ta slovenski standard je istoveten z: EN 50306-2:2020
ICS:
13.220.40 Sposobnost vžiga in Ignitability and burning
obnašanje materialov in behaviour of materials and
proizvodov pri gorenju products
29.060.20 Kabli Cables
45.060.01 Železniška vozila na splošno Railway rolling stock in
general
SIST EN 50306-2:2020 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 50306-2:2020

---------------------- Page: 2 ----------------------
SIST EN 50306-2:2020


EUROPEAN STANDARD EN 50306-2

NORME EUROPÉENNE

EUROPÄISCHE NORM
March 2020
ICS 13.220.40; 29.060.20; 45.060.01 Supersedes EN 50306-2:2002 and all of its amendments
and corrigenda (if any)
English Version
Railway applications - Railway rolling stock cables having
special fire performance - Thin wall - Part 2: Single core cables
Applications ferroviaires - Câbles pour matériel roulant Bahnanwendungen - Kabel und Leitungen für
ferroviaire ayant des performances particulières de Schienenfahrzeuge mit verbessertem Verhalten im
comportement au feu - Isolation mince - Partie 2: Câbles Brandfall - Reduzierte Isolierwanddicken - Teil 2: Einadrige
monoconducteurs Kabel und Leitungen
This European Standard was approved by CENELEC on 2019-12-30. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2020 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 50306-2:2020 E

---------------------- Page: 3 ----------------------
SIST EN 50306-2:2020
EN 50306-2:2020 (E)

Contents Page
European foreword .3
Introduction .4
1 Scope .5
2 Normative references .5
3 Terms and definitions .6
4 Single-core cables .6
4.1 General .6
4.2 Marking and code designation .6
4.2.1 Marking of cable .6
4.2.2 Code Designation .
...