Medical electrical equipment - Part 2: Particular requirements for the safety of capacitor discharge X-ray generators

Establishes requirements applying to capacitor discharge X-ray generators for medical radiology in which electrical energy for loading of the X-ray tube is primarily stored at and switched in the high-voltage circuit. Its object is to ensure safety and to specify methods for demonstrating compliance with the safety requirements.

Medizinische elektrische Geräte - Teil 2: Besondere Festlegungen für die Sicherheit von Kondensatorgeneratoren

Appareils électromédicaux - Partie 2: Règles particulières de sécurité pour groupes radiogènes à décharge de condensateur

Etablit des prescriptions qui s'appliquent aux groupes radiogènes à décharge de condensateur pour la radiographie médicale dans lesquels l'énergie électrique est surtout emmagasinée dans un condensateur et commutée dans un circuit à haute tension. Son objet est d'assurer la sécurité et d'établir des méthodes pour la conformité avec les prescriptions de sécurité.

Medical electrical equipment - Part 2: Particular requirements for the safety of capacitor discharge X-ray generators (IEC 60601-2-15:1988)

General Information

Status
Withdrawn
Publication Date
20-Nov-1989
Withdrawal Date
31-Mar-2004
Drafting Committee
IEC/SC 62B - IEC_SC_62B
Parallel Committee
IEC/SC 62B - IEC_SC_62B
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Apr-2004
Completion Date
01-Apr-2004

Relations

Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Standardization document

HD 395.2.15 S1:1998

English language
40 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

HD 395.2.15 S1:1989 is a standardization document published by CLC. Its full title is "Medical electrical equipment - Part 2: Particular requirements for the safety of capacitor discharge X-ray generators". This standard covers: Establishes requirements applying to capacitor discharge X-ray generators for medical radiology in which electrical energy for loading of the X-ray tube is primarily stored at and switched in the high-voltage circuit. Its object is to ensure safety and to specify methods for demonstrating compliance with the safety requirements.

Establishes requirements applying to capacitor discharge X-ray generators for medical radiology in which electrical energy for loading of the X-ray tube is primarily stored at and switched in the high-voltage circuit. Its object is to ensure safety and to specify methods for demonstrating compliance with the safety requirements.

HD 395.2.15 S1:1989 has the following relationships with other standards: It is inter standard links to EN 60601-2-28:1993, EN 60601-2-32:1994, EN 60601-1-3:1994. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

HD 395.2.15 S1:1989 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...