Safety in electroheat installations - Part 6: Specifications for safety in industrial microwave heating equipment

IEC 60519-6:2011 is applicable to equipment using microwave energy alone or in combination with other kinds of energy for industrial heating of materials. This part is applicable to industrial microwave heating equipment operating in the frequency range 300 MHz to 300 GHz. This third edition cancels and replaces the second edition published in 2002 and constitutes a technical revision. The significant changes with respect to the previous edition are as follows: - the third edition of IEC 60519-1:2003 has been taken into account (the structure of clauses was adapted to it as far as practicable); - some definitions are modified or brought into line with IEC 60050-841:2004; - clauses on abnormal operation, access openings, microwave enclosure and barriers are added; - the microwave leakage measurements are in a normative Annex A; - an informative Annex B on the rationales for microwave exposure and leakage limits is added; - Bibliography is added.

Sicherheit in Elektrowärmeanlagen – Teil 6: Sicherheitsanforderungen für industrielle Mikrowellen-Erwärmungseinrichtungen

Sécurité dans les installations électrothermiques - Partie 6: Spécifications pour les installations de chauffage industriel à hyperfréquences

La CEI 60519-6:2011 est applicable aux installations qui utilisent l'énergie à hyperfréquences, seule ou en combinaison avec d'autres formes d'énergie pour le chauffage industriel des matériaux. La présente partie est applicable aux installations électrothermiques industrielles fonctionnant dans la plage de fréquences comprises entre 300 MHz et 300 GHz. Cette troisième édition annule et remplace la deuxième édition parue en 2002, dont elle constitue une révision technique. Les modifications techniques significatives par rapport à l'édition précédente sont les suivantes: - la troisième édition de la CEI 60519-1:2003 a été prise en compte (la structure des articles a été adaptée à celle-ci dans la mesure du possible); - certaines définitions ont été modifiées ou alignées avec la CEI 60050-841:2004; - des articles concernant un fonctionnement anormal, les ouvertures d'accès, l'enceinte hyperfréquences et les barrages ont été ajoutés; - les mesures de la fuite d'hyperfréquences se trouvent dans une Annexe normative A; - une Annexe informative B concernant les justifications des limites d'exposition aux hyperfréquences et des fuites d'hyperfréquences a été ajoutée; - une bibliographie a été ajoutée.

Varnost pri električnih grelnih inštalacijah - 6. del: Specifikacije za varnost pri industrijski opremi za mikrovalovno ogrevanje (IEC 60519-6:2011)

Ta del IEC 60519 velja za opremo, ki uporablja samo mikrovalovno energijo ali v kombinaciji z drugimi vrstami energije za industrijsko ogrevanje materialov. Ta del velja za industrijsko opremo za mikrovalovno ogrevanje, ki deluje v frekvenčnem razponu od 300 MHz do 300 GHz. OPOMBA 1: Ker je valovna dolžina zgornjega konca mikrovalovnega pasu pri 300 GHz zelo kratka in je potrebna posebna merilna oprema za merjenje uhajanja v spodnjem koncu pasu, velja specifikacija za merjenje izpusta mikrovalov v dodatku A samo za frekvence ISM med 800 MHz in 6 GHz. Osrednje frekvence teh so 2,45 GHz in 5,8 GHz na splošno in v nekaterih regijah med 896 MHz in 918 MHz. Za tako mikrovalovno opremo velja IEC 62311. Za druge mikrovalovne frekvence se lahko uporabljajo osnovne omejitve, obravnavane v informativnem dodatku B ali v smernicah ICNIRP (glej bibliografijo). Ta del ne velja za aparate za gospodinjsko ali podobno uporabo (zajete v IEC 60335-2-25), gospodarsko uporabo (zajete v IEC 60335-2-90) ali laboratorijsko uporabo (zajete v 61010-2-010).

General Information

Status
Published
Publication Date
21-Apr-2011
Withdrawal Date
02-Mar-2014
Current Stage
6060 - Document made available - Publishing
Start Date
22-Apr-2011
Completion Date
22-Apr-2011

Relations

Buy Standard

Standard
EN 60519-6:2011
English language
31 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-junij-2011
1DGRPHãþD
SIST EN 60519-6:2003
9DUQRVWSULHOHNWULþQLKJUHOQLKLQãWDODFLMDKGHO6SHFLILNDFLMH]DYDUQRVWSUL
LQGXVWULMVNLRSUHPL]DPLNURYDORYQRRJUHYDQMH ,(&
Safety in electroheat installations - Part 6: Specifications for safety in industrial
microwave heating equipment (IEC 60519-6:2011)
Lichtbogenschweißeinrichtungen - Teil 6: Schweißstromquellen mit begrenzter
Einschaltdauer (IEC 60519-6:2011)
Sécurité dans les installations électrothermiques - Partie 6: Spécifications pour les
installations de chauffage industriel à hyperfréquences (CEI 60519-6:2011)
Ta slovenski standard je istoveten z: EN 60519-6:2011
ICS:
25.180.10 (OHNWULþQHSHþL Electric furnaces
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 60519-6
NORME EUROPÉENNE
April 2011
EUROPÄISCHE NORM
ICS 25.180.10 Supersedes EN 60519-6:2002

English version
Safety in electroheat installations -
Part 6: Specifications for safety in industrial microwave heating
equipment
(IEC 60519-6:2011)
Sécurité dans les installations Lichtbogenschweißeinrichtungen -
électrothermiques - Teil 6: Schweißstromquellen mit
Partie 6: Spécifications pour les begrenzter Einschaltdauer
installations de chauffage industriel à (IEC 60519-6:2011)
hyperfréquences
(CEI 60519-6:2011)
This European Standard was approved by CENELEC on 2011-03-03. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60519-6:2011 E
Foreword
The text of document 27/704/CDV, future edition 3 of IEC 60519-6, prepared by IEC TC 27, Industrial
electroheating, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as
EN 60519-6 on 2011-03-03.
This European Standard supersedes EN 60519-6:2002.
The significant changes with respect to EN 60519-6:2002 are as follows:
– the third edition of EN 60519-1:2003 has been taken into account (the structure of clauses was
adapted to it as far as practicable);
– some definitions are modified or brought into line with IEC 60050-841:2004;
– clauses on abnormal operation, access openings, microwave enclosure and barriers are added;
– the microwave leakage measurements are in a normative Annex A;
– an informative Annex B on the rationales for microwave exposure and leakage limits is added;
– Bibliography is added.
This part of EN 60519 is to be used in conjunction with EN 60519-1:2003. It is intended to specify
particular requirements for industrial microwave heating equipment. This Part 6 supplements or modifies
the corresponding clauses of EN 60519-1, so as to convert it into an EN standard. Where a particular
sub-clause of Part 1 is not mentioned in this Part 6, that sub-clause applies as far as is reasonable.
Where this standard states "addition", modification" or "replacement", the relevant text of Part 1 is to be
adapted accordingly.
NOTE Sub-clauses and notes which are additional to those in Part 2 are numbered starting from 101, additional
items and annexes are lettered aa, bb or AA, BB, etc.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2011-12-03
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-03-03
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60519-6:2011 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60335-2-25 NOTE  Harmonized as EN 60335-2-25.
IEC 60335-2-90 NOTE  Harmonized as EN 60335-2-90.
IEC 61010-2-010 NOTE  Harmonized as EN 61010-2-010.
IEC 62311:2007 NOTE  Harmonized as EN 62311:2008 (modified)
__________
- 3 - EN 60519-6:2011
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year

IEC 60050-841 2004 International Electrotechnical Vocabulary - -
(IEV) -
Part 841: Industrial electroheat

1)
IEC 60519-1 2003 Safety in electroheat installations - EN 60519-1 2003
Part 1: General requirements
IEC 61307 - Industrial microwave heating installations - EN 61307 -
Test methods for the determination of power
output
IEC 60417-DB Graphical symbols for use on equipment - -
-
1)
EN 60519-1 is superseded by EN 60519-1:2011, which is based on IEC 60519-1:2010.

IEC 60519-6 ®
Edition 3.0 2011-01
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Safety in electroheat installations –
Part 6: Specifications for safety in industrial microwave heating equipment

Sécurité dans les installations électrothermiques –
Partie 6: Spécifications pour les installations de chauffage industriel à
hyperfréquences
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX U
ICS 25.180.10 ISBN 978-2-88912-322-3

– 2 – 60519-6 © IEC:2011
CONTENTS
FOREWORD . 3
INTRODUCTION . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 7
4 Classification of electroheat equipment according to voltage bands . 9
5 Classification of electroheat equipment according to frequency bands . 9
6 General requirements . 9
7 Isolation and switching . 12
8 Connection to the supply network and internal connections . 12
9 Protection against electric shock . 12
10 Protection against overcurrent . 12
11 Equipotential bonding . 12
12 Control circuits and control functions . 12
13 Protection against thermal influences . 13
14 Risk of fire and danger of explosion . 13
15 Marking, labelling and technical documentation . 14
16 Information on inspection and commissioning, and instructions for utilization and
maintenance of electroheat installations . 16
Annex AA (normative) Measurement of microwave leakage . 18
Annex BB (informative) Rationales for the microwave access barrier and associated
leakage tests . 22
Bibliography . 28

Figure 1 – Examples of warning labels . 15
Figure A.1 – Large microwave access barrier for conveyorised microwave heating
equipment . 19
Figure A.2 – Small microwave access barrier for conveyorised microwave heating
equipment . 20
Figure A.3 – Vertical-only microwave access barriers for conveyorised microwave
heating equipment . 21

Table 1 – Dimensional requirements on microwave access barriers . 11

60519-6 © IEC:2011 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
SAFETY IN ELECTROHEAT INSTALLATIONS –

Part 6: Specifications for safety in industrial
microwave heating equipment
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and
non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates
closely with the International Organization for Standardization (ISO) in accordance with conditions determined
by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publicati
...

Questions, Comments and Discussion