EN 60044-2:1999/A1:2000
(Amendment)Instrument transformers - Part 2: Inductive voltage transformers
- BACK
- 26-Oct-2000
- 31-Jul-2003
- 17.220.20
- 89/336/EEC
- CLC/TC 38
Instrument transformers - Part 2: Inductive voltage transformers
EN following parallel vote * Superseded by EN 61869-3:2011
Messwandler - Teil 2: Induktive Spannungswandler
Transformateurs de mesure - Partie 2: Transformateurs inductifs de tension
Merilni transformatorji - 2. del: Induktivni napetostnik (IEC 6004-2:1997/A1:2000)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-marec-2001
Merilni transformatorji - 2. del: Induktivni napetostnik (IEC 6004-2:1997/A1:2000)
Instrument transformers -- Part 2: Inductive voltage transformers
Messwandler -- Teil 2: Induktive Spannungswandler
Transformateurs de mesure -- Partie 2: Transformateurs inductifs de tension
Ta slovenski standard je istoveten z: EN 60044-2:1999/A1:2000
ICS:
17.220.20 0HUMHQMHHOHNWULþQLKLQ Measurement of electrical
PDJQHWQLKYHOLþLQ and magnetic quantities
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
SI
...
This May Also Interest You
IEC 61869-99:2022 contains the glossary of specific terminology and definitions used in the field of instrument transformers within the various parts of the series. Unless it is otherwise specified, in this document all periodic electrical quantities are understood to be RMS values.
- Standard56 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 61869-13:2021 is a product standard and covers only additional requirements for stand-alone merging units (SAMUs) used for AC applications having rated frequencies from 15 Hz to 100 Hz. The digital output format specification is not covered by this document; it is standardized in IEC 61869-9 as an application of IEC 61850, which specifies the power utility communication architecture. This document covers SAMUs having standardized analogue inputs (for example: 1 A, 5 A, 3,25 V / √3 or 100 V / √3) provided by instrument transformers compliant with relevant product standards (e.g. IEC 61869-2 to IEC 61869-5, IEC 61869-7, IEC 61869-8, IEC 61869-10, IEC 61869-11, IEC 60044-1 to IEC 60044-6, IEC 60185, IEC 60186, IEEE C57.13), and aims to convert them to the digital output compliant with IEC 61869-9. Other input and output types are outside the scope of this document. Appropriate SAMU functionality can be combined with switchgear controller functionality defined in IEC 62271-3 or other IED functionality defined in IEC 60255 (all parts). Cyber security requirements are outside the scope of this document and are covered by the IEC 62351 series. IEC 61869-13:2021 is to be used in conjunction with IEC 61869-9:2016, Digital interface for instrument transformers, and IEC 618696:2016, Additional general requirements for low-power instrument transformers, which, in turn, are based on IEC 61869-1:2007, General requirements.
- Standard74 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 61869-9:2016(E) is a product family standard applicable to instrument transformers with digital output. The product standard is composed of IEC 61869-1 and IEC 61869-6, in addition to this standard and the relevant product specific standards in the IEC 61869 series (Part 7, Part 8, Part 12, Part 13, Part 14, and Part 15). This standard defines requirements for digital communications of instrument transformer measurements. It is based on the IEC 61850 series, UCA international users group document Implementation guideline for digital interface to instrument transformers using IEC 61850-9-2, and the relevant parts of IEC 60044-8 that are replaced by this standard. It includes additional improvements including the IEC 61588 network based time synchronization. This first edition replaces the corresponding specific requirements previously contained in IEC 60044-8, published in 2002. This International Standard contains specific requirements for electronic low power instrument transformers (LPIT) having a digital output. However, the reader is encouraged to use its most recent edition. This publication contains an attached file in the form of a .xml file. This file is intended to be used as a complement and does not form an integral part of the publication.
- Standard64 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard64 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Jul-2019
- 04-Jul-2022
- 17.220.20
- 2004/108/EC
- 2004/108/EU
- 2006/95/EC
- 2014/35/EU
- M/511
- CLC/TC 38
IEC 61869-15:2018 provides all requirements specific to voltage transformers to be used in DC applications (DCVTs), whatever the technology used. The output signal can be analogue or digital. It is applicable to newly manufactured voltage transformers used for measuring, protection and/or control applications in DC power systems with a rated voltage above 1,5 kV. This document covers passive voltage dividers as well as active voltage transformers, used for measurement, control and protection. The general configuration of a single-pole low-power instrument transformer is described in Figure 601 of IEC 61869-6:2016. IEC 61869-15:2018 applies to voltage transformers (VT) intended to be used in DC applications with the following functions: • measure DC voltage (with significant harmonics); • withstand DC voltage. Two main technologies of DC converters exist today: LCC and VSC • Line-commutated converters (LCC) are based on thyristor converters. They are characterized by a single direction of current flow, and a voltage polarity reversal possibility. Significant voltage and current harmonics exist up to frequencies of about 3 kHz to 4 kHz. • Voltage source converters (VSC) are based on transistor converters. They are characterized by a bi-directional current flow and a single voltage polarity. Voltage and current harmonics exist up to frequencies of about 20 kHz.
- Standard38 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard38 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Jul-2019
- 04-Jul-2022
- 17.220.20
- 2004/108/EC
- 2004/108/EU
- CLC/TC 38
IEC 61869-11:2017 is a product standard and covers only additional requirements for low-power passive voltage transformers (passive LPVT). The product standard for low-power passive voltage transformers is composed of IEC 61869-1, along with IEC 61869-6 and this document with specific requirements. This document is applicable to newly manufactured low-power passive voltage transformers with analogue output having rated frequencies from 15 Hz to 100 Hz for use with electrical measuring instruments or electrical protective devices. This document covers low-power passive voltage transformers used for measurement or protection and low-power passive voltage transformers used for both measurement and protection. Low-power passive voltage transformers have analogue output only (for digital output or for technology using any kind of active electronic components refer to future IEC 61869-7). Such low-power passive voltage transformers can include the secondary signal cable (transmitting cable). The secondary voltage of the low-power passive voltage transformer is proportional to the primary voltage. Derivative output signals are not within the scope of this document. This first edition of IEC 61869-11, together with IEC 61869-1 and IEC 61869-6, cancels and replaces the relevant clauses or subclauses of the first edition of IEC 60044-7, published in 1999 and the first edition of IEC 60044-8, published in 2002. This edition constitutes a technical revision.
- Standard36 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard36 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 61869-10:2017 is a product standard and covers only additional requirements for low-power passive current transformers. The product standard for low-power passive current transformers comprises IEC 61869-1, together with IEC 61869-6 and this document with specific requirements. This document is applicable to newly manufactured low-power passive current transformers with analogue output for use with electrical measuring instruments or electrical protective devices having a rated frequency from 15 Hz to 100 Hz. This document covers low-power passive current transformers used for measurement or protection and multi-purpose low-power passive current transformers used for both measurement and protection. This first edition of IEC 61869-10, together with IEC 61869-1, IEC 61869-6, IEC 61869-8 and IEC 61869-9, cancels and replaces the first edition of IEC 60044-8, published in 2002. This edition constitutes a technical revision. The technical changes concern IEC TC 38's decision to restructure the whole set of stand-alone standards in the IEC 60044 series and transform it into a new set of standards composed of general requirements documents and specific requirements documents.
- Standard45 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard45 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 62689-2:2016 describes electric phenomena and electric system behaviour during faults, according to the most widely diffused distribution system architecture and to fault typologies, to define the functional requirements for fault passage indicators (FPI) and distribution substation units (DSU) (including their current and/or voltage sensors), which are, respectively, a device or a device/combination of devices and/or of functions able to detect faults and provide indications about their localization. By localization of the fault is meant the fault position with respect to the FPI/DSU installation point on the network (upstream or downstream from the FPI/DSU's location) or the direction of the fault current flowing through the FPI itself. The fault localization may be obtained - directly from the FPI/DSU, or - from a central system using information from more FPIs or DSUs, considering the features and the operating conditions of the electric system where the FPIs/DSUs are installed. This part of IEC 62689 is therefore aimed at helping users in the appropriate choice of FPIs/DSUs (or of a system based on FPI/DSU information) properly operating in their networks, considering adopted solutions and operation rules (defined by tradition and/or depending on possible constraints concerning continuity and quality of voltage supply defined by a national regulator), and also taking into account complexity of the apparatus and consequent cost. This part of IEC 62689 is mainly focused on system behaviour during faults, which is the "core" of FPI/DSU fault detection capability classes described in IEC 62689-1, where all requirements are specified in detail.
- Standard52 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 61869-6:2016(E) is a product family standard and covers only additional general requirements for low-power instrument transformers (LPIT) used for a.c. applications having rated frequencies from 15 Hz to 100 Hz covering MV, HV and EHV or used for d.c. applications. This product standard is based on IEC 61869-1:2007, in addition to the relevant product specific standard. This part of IEC 61869 does not cover the specification for the digital output format of instrument transformers. This part of IEC 61869 defines the errors in case of analogue or digital output. The other characteristics of the digital interface for instrument transformers are standardised in IEC 61869-9 as an application of the standards, the IEC 61850 series, which details layered substation communication architecture. This part of IEC 61869 considers additional requirements concerning bandwidth. General Requirements; however, the reader is encouraged to use its most recent edition. This first edition of IEC 61869-6 cancels and replaces the relevant parts of IEC 60044-7, published in 1999, and of IEC 60044-8, published in 2002. This publication is to be read in conjunction with IEC 61869-1:2007
- Standard91 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard91 pagesEnglish languagesale 10% offe-Library read for×1 day
- 22-Dec-2016
- 22-Dec-2019
- 17.220.20
- 2004/108/EC
- 2004/108/EU
- 2006/95/EC
- CLC/TC 38
IEC 62689-1:2016 defines the minimum requirements (therefore performances) and consequent classification and tests (with the exception of functional and communication ones) for fault passage indicators (FPIs) and distribution substation units (DSUs) (including their current and/or voltage sensors), which are, respectively, a device or a device/combination of devices and/or functions able to detect faults and provide indications about their localization.
- Standard90 pagesEnglish languagesale 10% offe-Library read for×1 day
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for×1 day
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion