Mating dimensions between differential pressure (type) measuring instruments and flanged-on shut-off devices up to 413 bar (41,3 MPa)

Applicable to differential pressure (type) measuring instruments (instrument) with a shut-off device (manifold) directly bolted on to them.

Anschlussmaße zwischen Wirkdruck-Messgeräten und angeflanschten Absperrorgangen bis 413 bar (41,3 MPa)

Dimensions des raccords entre les instruments de mesure à différentiel de pression et les dispositifs d'arrêt sur bride allant jusqu'à 413 bar (41,3 MPa)

S'applique aux instruments de mesure de pression différentielle (type) équipés directement dun appareil de coupure (collecteur) boulonné.

Mating dimensions between differential pressure (type) measuring instruments and flanged-on shut-off devices up to 413 bar (41, 3 MPa) (IEC 61518:2001) / Note: Includes Corrigendum of Februar 2002

General Information

Status
Published
Publication Date
20-Mar-2001
Withdrawal Date
31-Dec-2003
Drafting Committee
IEC/SC 65B - IEC_SC_65B
Parallel Committee
IEC/SC 65B - IEC_SC_65B
Current Stage
6060 - Document made available - Publishing
Start Date
21-Mar-2001
Completion Date
21-Mar-2001

Overview

EN 61518:2001 (CLC adoption of IEC 61518:2001, including Corrigendum Feb 2002) specifies the mating dimensions between differential pressure (type) measuring instruments and flanged‑on shut‑off devices (manifolds) for service up to 413 bar (41.3 MPa). The standard applies where a differential‑pressure instrument is fitted with a shut‑off device that is directly bolted to the instrument, defining the mechanical interface to ensure interchangeability and safe operation.

Key topics and requirements

  • Scope and applicability: Defines the interface limits for differential pressure measuring instruments with flanged‑on shut‑off devices up to 413 bar.
  • Mating dimensions: Specifies the geometric relationships and dimensional requirements for the instrument/manifold mating surfaces to ensure correct fit‑up and alignment.
  • Flange interface features: Covers flange faces, bolt‑hole patterns and position relationships necessary for direct bolting of shut‑off devices to instruments (pressure class up to 413 bar).
  • Compatibility and interchangeability: Ensures instruments and manifolds from different manufacturers will mechanically mate when built to the standard.
  • Mounting and sealing considerations: Addresses the interface features that affect sealing performance and mechanical load transfer (e.g., alignment, contact surfaces).
  • Reference to corrigendum: Incorporates amendments published in the February 2002 corrigendum to IEC 61518:2001.

(Note: EN 61518:2001 defines mechanical interface requirements; it does not replace detailed pressure‑rating, material selection, or local installation rules.)

Applications

  • Instrument manufacturers and manifold (shut‑off device) designers use EN 61518 to design mechanical interfaces that are interchangeable across suppliers.
  • Process and instrumentation engineers in oil & gas, petrochemical, power generation, and industrial process control use the standard to specify compatible differential pressure transmitters and manifolds for high‑pressure service (up to 413 bar).
  • Procurement and maintenance teams rely on the standard to ensure replacement parts and retrofits will fit without custom machining or modification.
  • Calibration and test laboratories benefit from consistent mounting interfaces for reliable test setups.

Related standards

  • IEC 61518:2001 (original international publication) - identical technical content.
  • Corrigendum IEC 61518 (Feb 2002) - incorporated corrections.
  • Complementary standards may cover pressure instrument performance, process connections and flange design (refer to applicable ISO/ASME or industry specifications for pressure ratings, materials and testing).

Keywords: EN 61518:2001, IEC 61518, mating dimensions, differential pressure measuring instruments, flanged‑on shut‑off devices, manifold, 413 bar, instrument‑manifold compatibility, pressure instrumentation standard.

Frequently Asked Questions

EN 61518:2001 is a standard published by CLC. Its full title is "Mating dimensions between differential pressure (type) measuring instruments and flanged-on shut-off devices up to 413 bar (41,3 MPa)". This standard covers: Applicable to differential pressure (type) measuring instruments (instrument) with a shut-off device (manifold) directly bolted on to them.

Applicable to differential pressure (type) measuring instruments (instrument) with a shut-off device (manifold) directly bolted on to them.

EN 61518:2001 is classified under the following ICS (International Classification for Standards) categories: 23.060 - Valves. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 61518:2001 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Mating dimensions between differential pressure (type) measuring instruments and flanged-on shut-off devices up to 413 bar (41, 3 MPa) (IEC 61518:2001) / Note: Includes Corrigendum of Februar 2002Anschlussmaße zwischen Wirkdruck-Messgeräten und angeflanschten Absperrorgangen bis 413 bar (41,3 MPa)Dimensions des raccords entre les instruments de mesure à différentiel de pression et les dispositifs d'arrêt sur bride allant jusqu'à 413 bar (41,3 MPa)Mating dimensions between differential pressure (type) measuring instruments and fla
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...