EN 50083-7:1996
(Main)Cable networks for television signals, sound signals and interactive services - Part 7: System performance
Cable networks for television signals, sound signals and interactive services - Part 7: System performance
This standard is applicable to any cabled distribution system (including individual receiving systems) having a coaxial cable output and primarily intended for television and sound signals operating between about 30 MHz and 1750 MHz. This standard lays down the basic methods of measurement of the operational characteristics of cabled distribution systems having coaxial cable outputs in order to assess the performance of those systems and their performance limits. All requirements refer to the performance limits which shall be obtained between the input(s) to the headend or headends and any system outlet when terminated in a resistance equal to the nominal load impedance of the system, unless otherwise specified. Where system outlets are not used, the above applies at the susbcriber's end of the susbcriber's feeder. NOTE 1: Methods of measurement described in this standard are considered as basic. However, any equivalent method that ensures at least the same accuracy may be used. NOTE 2: If the system operator wishes to subdivide the system into a number of parts, the accumulation of degradations should not exceed the figures given below. NOTE 3: An extension of the frequency range to that from 5 MHz to 2050 MHz(3000 MHz) will be considered for future work
Kabelnetze für Fernsehsignale, Tonsignale und interaktive Dienste - Teil 7: Systemanforderungen
Réseaux de distribution par câbles pour signaux de télévision, signaux de radiodiffusion sonore et services interactifs - Partie 7: Caractéristiques des systèmes
Cabled distribution systems for television and sound signals -- Part 7: System performance
General Information
- Status
- Withdrawn
- Publication Date
- 21-Apr-1996
- Withdrawal Date
- 31-Aug-1996
- Technical Committee
- CLC/TC 209 - Cable networks for television signals, sound signals and interactive services
- Drafting Committee
- IEC/TC 100 - IEC_TC_100
- Parallel Committee
- IEC/TC 100 - IEC_TC_100
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Apr-2011
- Completion Date
- 01-Apr-2011
Relations
- Effective Date
- 28-Jan-2023
- Effective Date
- 29-Jan-2023
Frequently Asked Questions
EN 50083-7:1996 is a standard published by CLC. Its full title is "Cable networks for television signals, sound signals and interactive services - Part 7: System performance". This standard covers: This standard is applicable to any cabled distribution system (including individual receiving systems) having a coaxial cable output and primarily intended for television and sound signals operating between about 30 MHz and 1750 MHz. This standard lays down the basic methods of measurement of the operational characteristics of cabled distribution systems having coaxial cable outputs in order to assess the performance of those systems and their performance limits. All requirements refer to the performance limits which shall be obtained between the input(s) to the headend or headends and any system outlet when terminated in a resistance equal to the nominal load impedance of the system, unless otherwise specified. Where system outlets are not used, the above applies at the susbcriber's end of the susbcriber's feeder. NOTE 1: Methods of measurement described in this standard are considered as basic. However, any equivalent method that ensures at least the same accuracy may be used. NOTE 2: If the system operator wishes to subdivide the system into a number of parts, the accumulation of degradations should not exceed the figures given below. NOTE 3: An extension of the frequency range to that from 5 MHz to 2050 MHz(3000 MHz) will be considered for future work
This standard is applicable to any cabled distribution system (including individual receiving systems) having a coaxial cable output and primarily intended for television and sound signals operating between about 30 MHz and 1750 MHz. This standard lays down the basic methods of measurement of the operational characteristics of cabled distribution systems having coaxial cable outputs in order to assess the performance of those systems and their performance limits. All requirements refer to the performance limits which shall be obtained between the input(s) to the headend or headends and any system outlet when terminated in a resistance equal to the nominal load impedance of the system, unless otherwise specified. Where system outlets are not used, the above applies at the susbcriber's end of the susbcriber's feeder. NOTE 1: Methods of measurement described in this standard are considered as basic. However, any equivalent method that ensures at least the same accuracy may be used. NOTE 2: If the system operator wishes to subdivide the system into a number of parts, the accumulation of degradations should not exceed the figures given below. NOTE 3: An extension of the frequency range to that from 5 MHz to 2050 MHz(3000 MHz) will be considered for future work
EN 50083-7:1996 is classified under the following ICS (International Classification for Standards) categories: 33.060.40 - Cabled distribution systems. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 50083-7:1996 has the following relationships with other standards: It is inter standard links to EN 60728-1:2008, EN 50083-7:1996/A1:2000. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 50083-7:1996 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-1999
Cabled distribution systems for television and sound signals -- Part 7: System
performance
Cable networks for television signals, sound signals and interactive services -- Part 7:
System performance
Kabelnetze für Fernsehsignale, Tonsignale und interaktive Dienste -- Teil 7:
Systemanforderungen
Réseaux de distribution par câbles pour signaux de télévision, signaux de radiodiffusion
sonore et services interactifs -- Partie 7: Caractéristiques des systèmes
Ta slovenski standard je istoveten z: EN 50083-7:1996
ICS:
33.060.40 Kabelski razdelilni sistemi Cabled distribution systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...