FprEN IEC 63203-401-1:2026
(Main)Wearable electronic devices and technologies - Part 401-1: Devices and systems: functional elements - Measurement method of the stretchable resistive strain sensor
- Status
- Not Published
- Publication Date
- 03-Mar-2027
- Technical Committee
- CLC/SR 124 - Wearable Electronic Devices and Technologies
- Current Stage
- 5020 - Vote circulated - Formal Approval
- Start Date
- 23-Oct-2026
- Due Date
- 23-Oct-2026
- Completion Date
- 23-Oct-2026
FprEN IEC 63203-401-1:2026 is a CLC document based on IEC 63203-401-1 for wearable electronic devices and technologies. It specifies a measurement method for stretchable resistive strain sensors, including how to determine the linear area, strain limits, and gauge factor for sensors that undergo large deformations. The document is aimed at engineers, test laboratories, and suppliers who need a common way to measure and compare sensor-device performance.
What does FprEN IEC 63203-401-1:2026 specify?
FprEN IEC 63203-401-1:2026 specifies how to measure stretchable resistive strain sensors for large deformations. The focus is on sensor devices, not sensor materials, and the method is not intended for conventional thin-metal-film strain gauges.
The document is organized into clauses on scope, normative references, terms and definitions, test environments, test specimen, test equipment, test procedure, and report, followed by a bibliography. That structure tells the reader where to find the test conditions, how to run the measurement, and what to record at the end.
What are the key requirements of FprEN IEC 63203-401-1:2026?
FprEN IEC 63203-401-1:2026 is built around a controlled tensile test that relates strain to both mechanical response and resistance change. In practice, the user measures the sensor under defined conditions, identifies the usable linear range, and reports the result in a consistent format.
Test environment and specimen preparation
Clause 4 requires the test to be carried out at 23 °C ± 2 °C and 50 % ± 10 % relative humidity, matching ISO 291 class 2. This matters because stretchable materials and resistance measurements can shift with temperature and humidity.
Clause 5 requires the sensor device to have at least one terminal or lead wire for resistance measurement and an externally visible marking of the gauge length. The sensor may be a standalone device or may be integrated on the object being measured, so the same method can be used for both product forms.
Clause 5 also warns that the conductive filler network must not be changed irreversibly by stretching. In practice, that means the test must avoid overextension and repeated stretching beyond the sensor’s limit, because permanent changes can invalidate the result.
Test equipment
Clause 6 allows either a horizontal or vertical tensile testing machine, provided the sensor can be deformed longitudinally in a controlled way. For linear-area testing, the machine must be able to measure the elastic deformation area, because the method depends on knowing where reversible behavior ends.
Clause 6 requires a resistance measurement device using either a 2-terminal or 4-terminal method. If the resistance is below 1 kΩ, the 4-terminal method is recommended, which helps reduce measurement error. If response characteristics are being measured, the device needs data recording, with time resolution agreed between the user and supplier.
Clause 6 also requires a non-invasive way to measure gauge length change. A certified ruler or mechanical extensometer is the normal choice, while optical methods such as laser, interference light, camera systems, or digital image correlation can be used when higher accuracy is needed.
How the linear area, strain limit, and gauge factor are determined
Clause 7 says to measure both the stress-strain (S-S) curve and the resistance-versus-strain curve. The mechanical linear region comes from the straight-line part of the S-S curve, and the electrical linear region comes from the straight-line part of the resistance curve.
Clause 7 defines the strain limit from the point where the curve departs from linear behavior by 1.0 %, unless user and supplier agree otherwise. The document then takes the narrower of the mechanical and electrical linear regions as the sensor’s linear area, and the smaller of the two strain limits as the sensor’s strain limit.
Clause 7 also uses the slope in the electrically linear region as the gauge factor. In practice, this gives the user one sensitivity value tied to the part of the curve where the sensor behaves predictably.
The informative text in Clause 7 notes that response delay, creep, and hysteresis can occur in this type of sensor. The document recommends treating these effects in the same way as errors are treated for metal thin-film strain gauges, and suggests keeping later testing within 50 % or less of the strain limit.
What terms does FprEN IEC 63203-401-1:2026 define?
FprEN IEC 63203-401-1:2026 defines a small set of terms that matter for interpretation of the test method.
- Gauge factor - the ratio of resistance change to original resistance, divided by engineering strain along the stretching axis; it expresses sensor sensitivity.
- Gauge length - the length of the strain-sensing area in the measurement direction; it defines the active sensing span.
- Stretchable resistive strain sensor - a sensor that uses resistance change in a conductive material dispersed in a stretchable polymer; it is the device type this method measures.
- Mechanical linear region - the part of the stress-strain behavior that remains straight within the method’s error criterion; it marks reversible mechanical use.
- Electrical linear region - the part of the resistance-versus-strain behavior that remains straight within the method’s error criterion; it marks the range where output tracks strain predictably.
- Strain limit - the smaller of the mechanical and electrical limits; it is the practical upper boundary for the test range.
Who uses FprEN IEC 63203-401-1:2026?
FprEN IEC 63203-401-1:2026 is used by wearables engineers, sensor developers, test laboratories, quality teams, and suppliers of electronic components and wearable systems. They use it to verify sensor behavior, compare products, set test conditions, and document linear range, strain limit, and gauge factor in a common way.
What changed in FprEN IEC 63203-401-1:2026 from the previous edition?
FprEN IEC 63203-401-1:2026 is identified as identical to prEN IEC 63203-401-1:2025. The introduction says that ED2 is a fundamental review of the test method and that it was revised to resolve earlier confusion between evaluation of sensor devices and evaluation of sensor materials.
Which standards are used with FprEN IEC 63203-401-1:2026?
FprEN IEC 63203-401-1:2026 cites ISO 291:2008 as a normative reference, and uses it to set the standard atmosphere for conditioning and testing. The bibliography also points to IEC 63203-101-1:2021 for terminology in wearable electronic devices and technologies, and ASTM E251-92 for metallic bonded resistance strain gage performance characteristics.
What does the FprEN IEC 63203-401-1:2026 document contain?
FprEN IEC 63203-401-1:2026 contains the test environment, specimen requirements, equipment requirements, test procedure, and report items needed to measure a stretchable resistive strain sensor. It includes two example figures showing typical sensor construction, with substrate, sensing material, electrode, lead wire, sensing area, and gauge length.
The procedure explains how to build the S-S curve, how to identify the mechanical and electrical linear regions, and how to determine the strain limits and gauge factor. The informative part discusses response delay, creep, and hysteresis, which are important when judging real sensor behavior under repeated deformation.
The report clause lists the results that should be recorded: sensor identification, environment, mechanical and electrical linear regions and strain limits, overall linear range and strain limit, and gauge factor. That makes the document useful for testing, comparison, and technical reporting.
Relations
- Effective Date
- 12-Dec-2023
Frequently Asked Questions
FprEN IEC 63203-401-1:2026 is a draft published by CLC. Its full title is "Wearable electronic devices and technologies - Part 401-1: Devices and systems: functional elements - Measurement method of the stretchable resistive strain sensor". This standard covers: Wearable electronic devices and technologies - Part 401-1: Devices and systems: functional elements - Measurement method of the stretchable resistive strain sensor
Wearable electronic devices and technologies - Part 401-1: Devices and systems: functional elements - Measurement method of the stretchable resistive strain sensor
FprEN IEC 63203-401-1:2026 is classified under the following ICS (International Classification for Standards) categories: 31.020 - Electronic components in general. The ICS classification helps identify the subject area and facilitates finding related standards.
FprEN IEC 63203-401-1:2026 has the following relationships with other standards: It is inter standard links to EN IEC 63203-401-1:2023. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
FprEN IEC 63203-401-1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
91 Introduction
92 Generally, strain sensors (strain gauges) utilize changes in the electrical resistance of a thin 93 copper-nickel alloy coating formed on a polymer film such as PET film. The strain sensor is 94 bonded to the object to be measured, and the strain in the strain sensor caused by the strain in 95 the object to be measured is detected as a change in resistance of the thin metal film. 96 As is obvious from the sensor’s material and structure, the object to be measured is mainly a 97 high elastic modulus member such as a metal material, the amount of strain detected is very 98 small, and the resistance change that is the output is also small. Therefore, it is common to 99 detect resistance changes as voltage changes using a Wheatstone bridge circuit, without 100 directly measuring resistance values. In the range where the relationship between strain change 101 and resistance value change is linear, the proportionality constant between the two is called 102 the gauge factor. Several existing standards are known for gauge factor measurement and are 103 listed in Bibliography.
104 On the other hand, the strain sensor covered by this standard utilizes the change in resistance 105 caused by the deformation of a conductive material in which conductive filler is dispersed in a 106 stretchable polymer material (such as an elastomer).
107 However, compared to the strain sensor using thin metal film described above, the target strain 108 range and resistance value change range are significantly different, so new testing methods for 109 this type of strain sensor are needed. ED1 of this standard was published with unresolved 110 technical issues such as the confusion between evaluation of sensor devices and evaluation of 111 sensor materials.
112 In ED2, the test method has been fundamentally reviewed and revised as a measurement 113 method for sensor devices.
oSIST prEN IEC 63203-401-1:2026
116 WEARABLE ELECTRONIC DEVICES AND TECHNOLOGIES –
118 Part 401-1: Devices and systems: functional elements – 119 Measurement method of the stretchable resistive strain sensor
123 1 Scope 124 This part of IEC 63203-401 specifies a measurement method of the linear area and strain limits 125 and gauge factor of stretchable resistive strain sensors for large deformations. This standard 126 primarily targets strain sensors that undergo large deformations and utilize resistance changes 127 in conductive films made of conductive particles or organic elastic polymers. This is not a 128 measurement method for strain sensor materials. Furthermore, it cannot be applied to 129 conventional strain gauges that utilize resistance changes in thin metal films. 130 2 Normative references 131 The following documents are referred to in the text in such a way that some or all of their content 132 constitutes requirements of this document. For dated references, only the edition cited applies. 133 For undated references, the latest edition of the referenced document (including any 134 amendments) applies.
135 ISO 291:2008, Plastics – Standard atmospheres for conditioning and testing 136 3 Terms and definitions 137 For the purposes of this document, the following terms and definitions apply. 138 ISO and IEC maintain terminology databases for use in standardization at the following 139 addresses:
140 • IEC Electropedia: available at https://www.electropedia.org/ 141 • ISO Online browsing platform: available at https://www.iso.org/obp 142 3.1 143 gauge factor 144 G F 145 ratio of the change in electrical resistance divided by the original resistance ( R , resistance in 0 146 the undeformed configuration) to engineering strain (e) along the axis of the stretching 147 Note 1 to entry: Gauge factor is expressed as G = (R – R )/R・e, , where R is the initial resistance in the 0 0 0 F 148 undeformed configuration, R is the electrical resistance in the deformed configuration, and e is the tensile strain. 149 [SOURCE: IEC 62047-22:2014, 3.1.1 Error! Reference source not found. modified – "along 150 the axis of the stretching" has been added to the definition, and, in the note to entry, "where R 151 is the electrical resistance in the deformed configuration" has been replaced with "where R is 0 152 the initial resistance in the undeformed configuration, R is the electrical resistance in the 153 deformed configuration, and e is the tensile strain".]
oSIST prEN IEC 63203-401-1:2026
154 3.2 155 gauge length 156 length of the strain-sensing area of a stretchable strain sensor in the direction of the 157 measurement axis
...