EN 60901:1996/FprA6:2014/prAA:2016
(Amendment)Single-capped fluorescent lamps - Performance specifications
Single-capped fluorescent lamps - Performance specifications
2016-01-19: If the vote is accepted update directive information in mother standard.
To be merged with PR=24530
Einseitig gesockelte Leuchtstofflampen - Anforderungen an die Arbeitsweise
Lampes à fluorescence à culot unique - Prescriptions de performances
Fluorescenčne sijalke z enim vznožkom - Specifikacije lastnosti
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-2017
)OXRUHVFHQþQHVLMDONH]HQLPY]QRåNRP6SHFLILNDFLMHODVWQRVWL
Single-capped fluorescent lamps - Performance specifications
Einseitig gesockelte Leuchtstofflampen - Anforderungen an die Arbeitsweise
Lampes à fluorescence à culot unique - Prescriptions de performances
Ta slovenski standard je istoveten z: EN 60901:1996/FprA6:2014/prAA:2016
ICS:
29.140.30 )OXRUHVFHQþQHVLMDONH6LMDONH Fluorescent lamps.
Discharge lamps
SIST EN en
60901:2001/FprA6:2014/oprAA:2017
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD DRAFT
EN 60901:1996/
NORME EUROPÉENNE
FprA6:2014
EUROPÄISCHE NORM
FprAA
December 2016
ICS 29.140.30
English Version
Single-capped fluorescent lamps - Performance specifications
Lampes à fluorescence à culot unique - Prescriptions de Einseitig gesockelte Leuchtstofflampen - Anforderungen an
performances die Arbeitsweise
This draft amendment FprAA, if approved, will modify the European Standard ; it is submitted to CENELEC members for enquiry.
Deadline for CENELEC: 2017-03-10.
It has been drawn up by CLC/TC 34A.
If this draft becomes an amendment, CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.
This draft amendment was established by CENELEC in three official versions (English, French, German).
A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to
the CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Project: 58957 Ref. No. EN 60901:1996/FprA6:2014/prAA:2016 E
1 European foreword
2 This draft amendment to the draft European Standard EN 60901:1996/FprA6:2014/prAA:2016 was
3 prepared by CLC/TC 34A, Lamps. It contains common modifications to IEC 60901:1996/A6:2014 and
4 is submitted to Enquiry.
5 If approved, this draft amendment will be merged together with EN 60901:1996/FprA6:2014 and both
6 drafts will be published as one single document, i.e. EN 60901:1996/A6:201X (based on
7 IEC 60901:1996/A6:2014, modified), with the implementation dates of this prAA.
8 The following dates are proposed:
– latest date by which the existence of this document has to be (doa) dor + 6 months
announced at national level
– latest date by which this document has to be implemented at (dop) dor + 12 months
national level by publication of an identical
national standard or by endorsement
– latest date by which the national standards conflicting with this (dow) dor + 36 months
document have to be withdrawn (to be confirmed or
modified when voting)
9 Clauses, subclauses, notes, tables, figures and annexes which are additional to those in
10 IEC 60901:1996/A6:2014 are prefixed “Z”.
11 This document has been prepared under a mandate given to CENELEC by the European Commission
12 and the European Free Trade Association, and supports essential requirements of EU Directive(s).
13 For the relationship with EU Directive(s) see informative Annexes ZZ, which are an integral part of this
14 document.
15 This standard provides test methods related to parameters as prescribed by EC Regulation 245/2009,
16 and EU Regulation 874/2012 while conformity assessment (sampling, conformity procedures as well
17 as limits) for market surveillance are specified in the text of the above Regulations.
18 Text of prAA to EN 60901:1996/FprA6:2014
19 CONTENTS Add the following annexes:
20 Annex ZA (normative) Normative references to international publications with
21 their corresponding European publications
22 Annex ZZA (informative) Relationship between this European Standard and the
23 requirements of Commission Regulation (EC) No 245/2009
24 Annex ZZB (informative) Relationship between this European Standard and the
25 requirements of Commission Regulation (EU) No 874/2012
27 1.2.Z1 Add the following subclause before 1.3
28 1.2.Z1 Overall statement
29 Where a Commission Regulation specifies limits for parameters these limits shall be
30 used instead of the limits specified in this standard.
31 3.Z1 After 1.4.12 add new definitions 1.4.Z1 up to 1.4.Z3:
32 1.4.Z1
33 efficacy
34 ‘luminous efficacy of a source’, ‘light source efficacy’ or ‘lamp efficacy’ (η )
source
35 quotient of the luminous flux emitted (Ф) by the power consumed by the source
36 (P ). η = Ф / P . Unit: lm/W
source source source
37 Note 1 to entry: The power dissipated by auxiliary equipment such as ballasts is not included in the
38 power consumed by the source.
39 [SOURCE: Regulation 245/2009 Annex II, 1.a)]
40 1.4.Z2
41 lamp lumen maintenance factor (LLMF)
42 ratio of the luminous flux emitted by the lamp at a given time in its life to the initial
43 luminous flux
44 [SOURCE: Regulation 245/2009 Annex II, 1.b)]
45 1.4.Z3
46 lamp survival factor (LSF)
47 fraction of the total number of lamps which continue to operate at a given time under
48 defined conditions and switching frequency
49 [SOURCE: Regulation 245/2009 Annex II, 1.c)]
50 1.5.7 Before the text in 1.5.7, add a new header 1.5.7.Z1
51 1.5.7.Z1 General
52 After 1.5.7.Z1 add new subclauses 1.5.7.Z2 and 1.5.7.Z3
53 1.5.7.Z2 Chromaticity, Colour Temperature and Colour Rendering Index
54 The chromaticity coordinates and correlated colour temperature of an individual lamp
55 shall be calculated according to CIE 15 from a measurement made under the
56 conditions of Annex B.
57 The colour rendering index of an individual lamp shall be calculated according to
58 CIE 13.3 from a measurement made under the conditions of Annex B.
59 1.5.7.Z3 Efficacy
60 The efficacy of an individual lamp shall be calculated from a measurement of luminous
61 flux and power according to the conditions of Annex B.
62 1.5.8 Replace 1.5.8 with new subclauses 1.5.8.Z1 and 1.5.8. Z2
63 1.5.8.Z1 Lamp lumen maintenance factor
64 The lamp lumen maintenance factor of an individual lamp shall be calculated from
65 measurements of its luminous flux made at appropriate times according to the
66 conditions of Annex B. Lamp operation between these measurements shall be as
67 prescribed in Annex C.
68 1.5.8.Z2 Lamp survival
69 The survival of an individual lamp shall be determined by operating lamps under the
70 conditions prescribed in Annex C until the lamp fails to remain alight or delivers low
71 light output (in case of doubt, low light output refers to noticeably less than 50 % of
72 rated light output).
73 1.5.Z1 After 1.5.10 add a new subclause 1.5.Z1
74 1.5.Z1 Mercury content
75 The average mercury content shall be measured in accordance with the CV AAS
76 method as described in EN 62321-4. Lamp sample preparation shall be in accordance
77 with E
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.