Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty

This part of CISPR 16-4 specifies the method of applying Measurement Instrumentation Uncertainty (MIU) when determining compliance with CISPR disturbance limits. The material is also relevant to any EMC test when interpretation of the results and conclusions reached will be impacted by the uncertainty of the measurement instrumentation used during testing. NOTE In accordance with IEC Guide 107, CISPR 16-4-2 is a basic EMC standard for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of the EMC standard. CISPR and its sub-committees are prepared to co-operate with technical committees and product committees in the evaluation of the applicability of this standard for specific products. The annexes contain the background material used in providing the amount of MIU found in generating the CISPR values shown in Clauses 4 through 8 and hence provide valuable background material for those needing both initial and further information on MIU and how to take individual uncertainties in the measurement chain into account. The annexes, however, are not intended to be a tutorial or user manual or to be copied when making uncertainty calculations. For that purpose, the references shown in the bibliography, or other widely
recognized documents, may be used. Measurement instrumentation specifications are given in the CISPR 16-1 series, while the methods of measurement are covered in the CISPR 16-2 series. Further information and background on CISPR and radio disturbances is given in CISPR 16-3. The other parts of the
CISPR 16-4 series contain further information on uncertainties in general, statistics and limit modelling. See the introduction of this part for more information on the background and on the content of the CISPR 16-4 series.

Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 4-2: Unsicherheiten, Statistik und Modelle zur Ableitung von Grenzwerten (Störmodell) - Messgeräte-Unsicherheit

Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Partie 4-2: Incertitudes, statistiques et modélisation des limites - Incertitudes de mesure de l'instrumentation

Specifikacija za merilne naprave in metode za merjenje radijskih motenj in odpornosti - 4-2. del: Modeliranje negotovosti, statistike in mejnih vrednosti - Negotovost merilnih instrumentov - Dopolnilo A1

Ta del CISPR 16-4 določa metodo za uporabo negotovosti merilnih instrumentov (MIU) pri določanju skladnosti z mejami motenj po CISPR. Gradivo je pomembno tudi za vse preskuse EMC, pri katerih na razlago rezultatov in zaključke vpliva negotovost merilnih instrumentov, uporabljenih med preskušanjem.
OPOMBA: V skladu z Vodilom IEC 107 je CISPR 16-4-2 osnovni standard EMC, ki ga uporabljajo odbori za proizvode IEC. Kot je navedeno v Vodilu 107, so odbori za proizvode odgovorni za določevanje uporabe tega standarda EMC. CISPR in njegovi pododbori so pripravljeni sodelovati s tehničnimi odbori in odbori za proizvode pri ocenjevanju uporabnosti tega standarda za določene proizvode. Dodatki vsebujejo temeljno gradivo, ki se uporablja pri podajanju velikosti MIU, ugotovljene pri nastajanju vrednosti CISPR, prikazanih v točkah od 4 do 8, in so zato koristno temeljno gradivo za tiste, ki potrebujejo začetne in nadaljnje informacije o MIU in informacije o tem, kako v verigi meritev upoštevati posamezne negotovosti. Dodatki niso mišljeni kot priročniki za vajo ali uporabo ali za kopiranje pri izračunavanju negotovosti. V ta namen se lahko uporabljajo reference, navedene v bibliografiji, ali drugi splošno priznani dokumenti.
Specifikacije merilnih instrumentov so podane v seriji CISPR 16-1, merilne metode pa zajema serija CISPR 16-2. Nadaljnje informacije in ozadje o CISPR in radijskih motnjah so navedeni v CISPR 16-3. Drugi deli serije CISPR 16-4 vsebujejo več informacij o negotovosti na splošno, statistiki in modeliranju mejnih vrednosti. Za več informacij o ozadju in o vsebini serije CISPR 16-4 glejte uvod tega dela.

General Information

Status
Published
Publication Date
24-Jul-2014
Withdrawal Date
20-Mar-2017
Current Stage
6060 - Document made available - Publishing
Start Date
25-Jul-2014
Completion Date
25-Jul-2014

Relations

Overview

EN 55016-4-2:2011/A1:2014 (CISPR 16-4-2:2011/A1:2014) is a CLC/CENELEC amendment that specifies how to quantify measurement instrumentation uncertainty for radio disturbance and immunity measuring apparatus and methods. It is part of the CISPR 16 series addressing uncertainties, statistics and limit modelling for electromagnetic compatibility (EMC) measurements. Amendment A1 (2014) adds method-specific guidance - notably for conducted disturbance measurements using a coupling/decoupling network for emission (CDNE) - and expands uncertainty budgets and rationale for input quantities.

Key topics and technical requirements

  • Scope: Measurement instrumentation uncertainty for radio disturbance and immunity apparatus (aligned with CISPR 16-4-2).
  • New abbreviation: CDNE - coupling decoupling network for emission measurement.
  • Measurand (CDNE, 30–300 MHz): asymmetric (common‑mode) disturbance voltage referred to reference ground, expressed in dB(µV).
  • Input quantities to consider (examples listed explicitly):
    • Receiver reading and related receiver corrections (sine‑wave voltage accuracy, pulse amplitude and repetition response, noise-floor proximity)
    • Cable attenuation between CDNE and receiver
    • CDNE Voltage Division Factor (VDF) and VDF frequency interpolation error
    • CDNE impedance and mismatch effects (CDNE‑receiver)
    • Effects of ambient disturbances, grounding, and environment
  • Uncertainty budget: Amendment provides a worked uncertainty budget (Table B.7) for conducted measurements with assigned distributions and standard uncertainties; example result: expanded uncertainty U(V) = 2 u(V) = 3.79 dB for the given case.
  • Rationale and modelling: Detailed explanations (B.8) justify assumed distributions (normal, triangular, rectangular, U-shaped) and numerical estimates based on calibration reports and component tolerances.

Practical applications

  • Ensures repeatable, traceable EMC test results for compliance with regulatory and product standards.
  • Used by:
    • EMC test laboratories and accreditation bodies preparing uncertainty budgets
    • Compliance engineers and product manufacturers performing conducted emissions testing (30–300 MHz)
    • Test-equipment and CDNE manufacturers documenting calibration and VDF uncertainty
    • Standards committees and auditors assessing measurement quality and reporting consistency

Benefits and SEO keywords

This amendment helps laboratories produce robust measurement uncertainty estimates for conducted disturbance testing using CDNE, improving comparability of EMC test reports and compliance decisions. Keywords: EN 55016-4-2, CISPR 16-4-2, measurement instrumentation uncertainty, EMC measurement uncertainty, CDNE, conducted emissions, uncertainty budget, calibration, receiver corrections.

Related standards

  • CISPR 16-1-2 and CISPR 16-2-1 (referenced for measurement conditions and environment)
  • Other parts of CISPR 16 for EMC measurement apparatus and statistical methods

For authoritative application, consult the full EN 55016-4-2:2011/A1:2014 publication and accompanying CISPR guidance.

Amendment
EN 55016-4-2:2011/A1:2014
English language
7 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2014
Specifikacija za merilne naprave in metode za merjenje radijskih motenj in
odpornosti - 4-2. del: Modeliranje negotovosti, statistike in mejnih vrednosti -
Negotovost merilnih instrumentov - Dopolnilo A1
Specification for radio disturbance and immunity measuring apparatus and methods --
Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation
uncertainty
Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur
Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil
4-2: Unsicherheiten, Statistik und Modelle zur Ableitung von Grenzwerten (Störmodell) -
Messgeräte-Unsicherheit
Spécifications des méthodes et des appareils de mesure des perturbations
radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 4-2:
Incertitudes, statistiques et modélisation des limites - Incertitudes de mesure de
l'instrumentation
Ta slovenski standard je istoveten z: EN 55016-4-2:2011/A1:2014
ICS:
17.220.20 0HUMHQMHHOHNWULþQLKLQ Measurement of electrical
PDJQHWQLKYHOLþLQ and magnetic quantities
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 55016-4-2:2011/A1

NORME EUROPÉENNE
EUROPÄISCHE NORM
July 2014
ICS 33.100.10; 33.100.20
English Version
Specification for radio disturbance and immunity measuring
apparatus and methods - Part 4-2: Uncertainties, statistics and
limit modelling - Measurement instrumentation uncertainty
(CISPR 16-4-2:2011/A1:2014)
Spécifications des méthodes et des appareils de mesure Anforderungen an Geräte und Einrichtungen sowie
des perturbations radioélectriques et de l'immunité aux Festlegung der Verfahren zur Messung der hochfrequenten
perturbations radioélectriques - Partie 4-2: Incertitudes, Störaussendung (Funkstörungen) und Störfestigkeit -
statistiques et modélisation des limites - Incertitudes de Teil 4-2: Unsicherheiten, Statistik und Modelle zur Ableitung
mesure de l'instrumentation von Grenzwerten (Störmodell) - Messgeräte-Unsicherheit
(CISPR 16-4-2:2011/A1:2014) (CISPR 16-4-2:2011/A1:2014)
This amendment A1 modifies the European Standard EN 55016-4-2:2011; it was approved by CENELEC on 2014-03-21. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 55016-4-2:2011/A1:2014 E

Foreword
The text of document CISPR/A/1049/FDIS, future CISPR 16-4-2:2011/A1, prepared by CISPR SC A
“Radio-interference measurements and statistical methods” of CISPR “International special committee
on radio interference” was submitted to the IEC-CENELEC parallel vote and approved by CENELEC
as EN 55016-4-2:2011/A1:2014.
The following dates are fixed:
– latest date by which the document has to be implemented at (dop) 2014-11-01
national level by publication of an identical national
standard or by endorsement
– latest date by which the national standards conflicting with (dow) 2017-03-21
the document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard CISPR 16-4-2:2011/A1:2014 was approved by CENELEC as a
European Standard without any modification.

CISPR 16-4-2 ®
Edition 2.0 2014-02
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE

COMITÉ INTERNATIONAL SPÉCIAL DES PERTURBATIONS RADIOÉLECTRIQUES

BASIC EMC PUBLICATION
PUBLICATION FONDAMENTALE EN CEM

AMENDMENT 1
AMENDEMENT 1
Specification for radio disturbance and immunity measuring apparatus and

methods –
Part 4-2: Uncertainties, statistics and limit modelling – Measurement

instrumentation uncertainty
Spécifications des méthodes et des appareils de mesure des perturbations

radioélectriques et de l'immunité aux perturbations radioélectriques –

Partie 4-2: Incertitudes, statistiques et modélisation des limites – Incertitudes de

mesure de l’instrumentation
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX E
ICS 33.100.10; 33.100.20 ISBN 978-2-8322-1382-7

– 2 – CISPR 16-4-2 Amend.1  IEC:2014
FOREWORD
This amendment has been prepared by subcommittee A of CISPR: Radio-interference
measurements and statistical methods.
The text of this amendment is based on the following documents:
FDIS Report on voting
CISPR/A/1049/FDIS CISPR/A/1058/RVD

Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the stability date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

Frequently Asked Questions

EN 55016-4-2:2011/A1:2014 is a amendment published by CLC. Its full title is "Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty". This standard covers: This part of CISPR 16-4 specifies the method of applying Measurement Instrumentation Uncertainty (MIU) when determining compliance with CISPR disturbance limits. The material is also relevant to any EMC test when interpretation of the results and conclusions reached will be impacted by the uncertainty of the measurement instrumentation used during testing. NOTE In accordance with IEC Guide 107, CISPR 16-4-2 is a basic EMC standard for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of the EMC standard. CISPR and its sub-committees are prepared to co-operate with technical committees and product committees in the evaluation of the applicability of this standard for specific products. The annexes contain the background material used in providing the amount of MIU found in generating the CISPR values shown in Clauses 4 through 8 and hence provide valuable background material for those needing both initial and further information on MIU and how to take individual uncertainties in the measurement chain into account. The annexes, however, are not intended to be a tutorial or user manual or to be copied when making uncertainty calculations. For that purpose, the references shown in the bibliography, or other widely recognized documents, may be used. Measurement instrumentation specifications are given in the CISPR 16-1 series, while the methods of measurement are covered in the CISPR 16-2 series. Further information and background on CISPR and radio disturbances is given in CISPR 16-3. The other parts of the CISPR 16-4 series contain further information on uncertainties in general, statistics and limit modelling. See the introduction of this part for more information on the background and on the content of the CISPR 16-4 series.

This part of CISPR 16-4 specifies the method of applying Measurement Instrumentation Uncertainty (MIU) when determining compliance with CISPR disturbance limits. The material is also relevant to any EMC test when interpretation of the results and conclusions reached will be impacted by the uncertainty of the measurement instrumentation used during testing. NOTE In accordance with IEC Guide 107, CISPR 16-4-2 is a basic EMC standard for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of the EMC standard. CISPR and its sub-committees are prepared to co-operate with technical committees and product committees in the evaluation of the applicability of this standard for specific products. The annexes contain the background material used in providing the amount of MIU found in generating the CISPR values shown in Clauses 4 through 8 and hence provide valuable background material for those needing both initial and further information on MIU and how to take individual uncertainties in the measurement chain into account. The annexes, however, are not intended to be a tutorial or user manual or to be copied when making uncertainty calculations. For that purpose, the references shown in the bibliography, or other widely recognized documents, may be used. Measurement instrumentation specifications are given in the CISPR 16-1 series, while the methods of measurement are covered in the CISPR 16-2 series. Further information and background on CISPR and radio disturbances is given in CISPR 16-3. The other parts of the CISPR 16-4 series contain further information on uncertainties in general, statistics and limit modelling. See the introduction of this part for more information on the background and on the content of the CISPR 16-4 series.

EN 55016-4-2:2011/A1:2014 is classified under the following ICS (International Classification for Standards) categories: 33.100.10 - Emission; 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 55016-4-2:2011/A1:2014 has the following relationships with other standards: It is inter standard links to EN 55016-4-2:2011. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 55016-4-2:2011/A1:2014 is associated with the following European legislation: EU Directives/Regulations: 2004/108/EC, 2004/108/EU, 2014/30/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase EN 55016-4-2:2011/A1:2014 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.

이 기사는 무선 교란 및 면역 측정 기기와 방법에 대한 명세인 EN 55016-4-2:2011/A1:2014에 대해 다루고 있다. 특히, 측정 기기의 불확실성(MIU)을 적용하는 방법을 명시하고 있다. 이러한 불확실성은 교란 한계를 준수하는지 여부를 결정하고, 시험 중에 사용되는 측정기의 불확실성이 결과의 해석과 결론에 영향을 미칠 수 있다는 점에서 중요하다. CISPR 16-4-2는 IEC의 제품 위원회가 사용할 수 있는 기본 EMC 표준임을 언급하고 있다. 또한, CISPR은 기술 위원회 및 제품 위원회와 협력하여 특정 제품에 대한 이 표준의 적용 가능성을 결정하는 데 도움을 줄 의사가 있다고 밝혔다. 이 기사의 부록은 4부에서 8부까지 표시된 CISPR 값 생성 시 발견된 MIU 양을 제공하는 데 사용된 배경 자료를 포함하고 있으며, 개별 불확실성을 고려하는 방법에 대해 초기 및 추가 정보를 필요로 하는 사람들에게 유용한 배경 자료를 제공한다. 그러나, 부록은 불확실성 계산 시 자습서나 사용자 매뉴얼로 사용하기 위해 의도되지 않았다. 이러한 목적으로는 참고문헌에 제시된 참조자료나 다른 널리 알려진 문서를 사용할 수 있다. CISPR 16-1 시리즈에서는 측정 기기의 사양이 제공되고, CISPR 16-2 시리즈에서는 측정 방법이 다루어진다. CISPR 및 무선 교란에 대한 자세한 정보와 배경은 CISPR 16-3에서 제공된다. CISPR 16-4의 다른 부분은 일반적인 불확실성, 통계 및 한계 모델링에 대한 자세한 정보를 제공한다. 이 부분의 소개에서 배경과 CISPR 16-4 시리즈의 내용에 대한 추가 정보를 참조하라.

この記事は、EN 55016-4-2:2011/A1:2014という無線の妨害や免疫を測定する装置と方法の仕様について述べています。特に、測定装置の不確かさ(MIU)を適用する方法について規定しています。この不確かさは、妨害制限を満たしているかどうかを判断するのに重要であり、テスト中に使用される測定装置の不確かさが結果の解釈や結論に影響を与える可能性があります。CISPR 16-4-2は、IECの製品委員会が使用する基本的なEMC標準であることが述べられています。また、CISPRは技術委員会や製品委員会と協力して、特定の製品におけるこの標準の適用可能性を判断する責任を持っていると述べています。付録には、4から8の節で示されたCISPRの値を生成する際に得られたMIUの量を提供するための背景資料が含まれており、測定チェーンの個々の不確かさを考慮する上で初期および追加情報が必要な方に価値のある背景資料を提供します。ただし、付録はチュートリアルやユーザーマニュアルとして使用することを意図されていません。その目的には、参考文献に示された文献または他の一般的に認識されている文書を使用することができます。測定装置の仕様はCISPR 16-1シリーズで、測定方法はCISPR 16-2シリーズで規定されています。CISPRと無線妨害に関する詳細な情報はCISPR 16-3に記載されています。CISPR 16-4シリーズの他の部分には、一般的な不確かさや統計、限界モデリングに関するさらなる情報が含まれています。この部分の導入部で、背景およびCISPR 16-4シリーズの内容についての追加情報については、本文を参照してください。

The article discusses the specification for radio disturbance and immunity measuring apparatus and methods, specifically focusing on Measurement Instrumentation Uncertainty (MIU). It states that MIU is important for determining compliance with disturbance limits and can impact the interpretation of test results. It also mentions that CISPR 16-4-2 is a basic EMC standard that can be used by product committees of the IEC, and CISPR is willing to cooperate with technical committees and product committees to determine the applicability of this standard for specific products. The annexes of the article provide background information on MIU and how to account for individual uncertainties in the measurement chain. However, the annexes are not intended to be used as a tutorial or user manual for uncertainty calculations. The article also references other CISPR standards for measurement instrumentation specifications, methods of measurement, and further information on uncertainties, statistics, and limit modelling.