Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 1: Nickel-cadmium

IEC 61951-1:2013 specifies marking, designation, dimensions, tests and requirements for portable sealed nickel-cadmium small prismatic, cylindrical and button rechargeable single cells, suitable for use in any orientation. This third edition cancels and replaces the second edition (2003) and its amendment 1 (2005) of which it constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - addition of several new cell sizes; - introduction of a new cell type J; - creation of Annex A (informative): Capacity of batteries measurement.

Sekundärzellen und -batterien mit alkalischen oder anderen nichtsäurehaltigen Elektrolyten - Tragbare wiederaufladbare gasdichte Zellen und Batterien - Teil 1: Nickel-Cadmium

Accumulateurs alcalins et autres accumulateurs à électrolyte non acide - Accumulateurs étanches pour applications portables - Partie 1: Nickel-cadmium

L'IEC 61951-1:2017 spécifie le marquage, la désignation, les dimensions, les essais et les exigences applicables aux éléments et batteries d’accumulateurs parallélépipédiques, cylindriques et boutons, étanches, au nickel-cadmium, pouvant être utilisés dans toutes les orientations, pour applications portables. Cette édition inclut les modifications techniques majeures suivantes par rapport à l’édition précédente: - ajout du type de batterie; - révision de la Figure 3 (6.1.3.1); - ajout de la note "picot facultatif" au contact positif; - modification de la position de la ligne de repère du picot aux surfaces planes du contact positif (B et G).

Sekundarni členi in baterije z alkalnimi ali drugimi nekislinskimi elektroliti - Sekundarni hermetični členi in baterije za prenosne naprave - 1. del: Nikelj-kadmij

IEC 61951-1:2013 določa označevanje, določanje, dimenzije, preskuse in zahteve za majhne posamezne prenosne ponovno polnljive hermetične nikelj-kadmijeve prizmatične, cilindrične in gumbaste celice, ki se uporabljajo pri vsaki orientaciji. Ta tretja izdaja razveljavlja in nadomešča drugo izdajo (2003) in njeno dopolnilo 1 (2005), ter predstavlja tehnično popravljeno izdajo. Ta izdaja vključuje naslednje pomembne tehnične spremembe glede na prejšnjo izdajo:   – dodane so nove velikosti celic, – predstavitev novega tipa celice J, – oblikovanje dodatka A (informativno): Zmogljivost merjenja baterij.

General Information

Status
Published
Publication Date
18-May-2017
Withdrawal Date
10-Apr-2020
Current Stage
6060 - Document made available - Publishing
Start Date
19-May-2017
Completion Date
19-May-2017

Relations

Buy Standard

Standard
EN 61951-1:2018
English language
43 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61951-1:2018
01-maj-2018
1DGRPHãþD
SIST EN 61951-1:2014
6HNXQGDUQLþOHQLLQEDWHULMH]DONDOQLPLDOLGUXJLPLQHNLVOLQVNLPLHOHNWUROLWL
6HNXQGDUQLKHUPHWLþQLþOHQLLQEDWHULMH]DSUHQRVQHQDSUDYHGHO1LNHOMNDGPLM
Secondary cells and batteries containing alkaline or other non-acid electrolytes -
Secondary sealed cells and batteries for portable applications - Part 1: Nickel cadmium
Akkumulatoren und Batterien mit alkalischen oder anderen nichtsäurehaltigen
Elektrolyten - Tragbare wiederaufladbare gasdichte Einzelzellen - Teil 1: Nickel-
Cadmium
Accumulateurs alcalins et autres accumulateurs à électrolyte non acide - Accumulateurs
étanches pour applications portables - Partie 1: Nickel cadmium
Ta slovenski standard je istoveten z: EN 61951-1:2017
ICS:
29.220.30 $ONDOQLVHNXQGDUQLþOHQLLQ Alkaline secondary cells and
EDWHULMH batteries
SIST EN 61951-1:2018 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61951-1:2018

---------------------- Page: 2 ----------------------

SIST EN 61951-1:2018


EUROPEAN STANDARD EN 61951-1

NORME EUROPÉENNE

EUROPÄISCHE NORM
May 2017
ICS 29.220.30 Supersedes EN 61951-1:2014
English Version
Secondary cells and batteries containing alkaline or other non-
acid electrolytes - Secondary sealed cells and batteries for
portable applications - Part 1: Nickel-cadmium
(IEC 61951-1:2017)
Accumulateurs alcalins et autres accumulateurs à Akkumulatoren und Batterien mit alkalischen oder anderen
électrolyte non acide - Accumulateurs étanches pour nichtsäurehaltigen Elektrolyten - Tragbare wiederaufladbare
applications portables - Partie 1: Nickel-cadmium gasdichte Einzelzellen - Teil 1: Nickel-Cadmium
(IEC 61951-1:2017) (IEC 61951-1:2017)
This European Standard was approved by CENELEC on 2017-04-11. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 61951-1:2017 E

---------------------- Page: 3 ----------------------

SIST EN 61951-1:2018
EN 61951-1:2017
European foreword
The text of document 21A/622/FDIS, future edition 4 of IEC 61951-1, prepared by SC 21A "Secondary
cells and batteries containing alkaline or other non-acid electrolytes" of IEC/TC 21 "Secondary cells
and batteries" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
EN 61951-1:2017.

The following dates are fixed:
• latest date by which the document has to be (dop) 2018-01-11
implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2020-04-11
• latest date by which the national
standards conflicting with the
document have to be withdrawn

This document supersedes EN 61951-1:2014.

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.

Endorsement notice
The text of the International Standard IEC 61951-1:2017 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:

IEC 60051 Series NOTE Harmonized as EN 60051 Series.
IEC 60086 Series NOTE Harmonized as EN 60086 Series.
IEC 61434 NOTE Harmonized as EN 61434.
2

---------------------- Page: 4 ----------------------

SIST EN 61951-1:2018
EN 61951-1:2017
Annex ZA
(normative)

Normative references
...

Questions, Comments and Discussion