Abstract

This part of the IEC 61851 series, together with [IEC 61851-1 Ed. 3] and [IEC 61851-23 Ed 2.0]1, gives the requirements for DC electric vehicle charging stations with an Automated connection device (ACD) for conductive connection to the vehicle, with a rated supply voltage up to 1 000 V AC or up to 1 500 V DC and a rated output voltage up to 1 500 V DC. NOTE 1 This standard includes information on EV for conductive connection, but limited to the necessary content for describing the power and signalling interface. This part specifies the DC charging systems with an Automated connection device based on - system A described in Annex AA of [IEC 61851-23 Ed 2.0]. - system B described in Annex BB of [IEC 61851-23 Ed 2.0]. - system C described in Annex CC of [IEC 61851-23 Ed 2.0]. EMC requirements for DC EV charging stations are defined in [IEC 61851-21-2 Ed. 1 CDV]. This standard provides the general requirements for the control communication between a DC EV charging station and an EV. The requirements for digital communication between DC EV charging station and electric vehicle for control of DC charging are defined in [ISO15118-20 DIS] and [IEC 61851-24 Ed 2.0 CD]. This part only applies to Automatic couplers of category 2: using an electro-mechanical interface defined by [EN50696] for Systems described in Annex CC and Annex KK. System A, B are under consideration. This part does not apply for Automatic coupler of category 1: using a vehicle coupler defined by IEC 62196-2 or IEC 62196-3. This standard does not cover all safety aspects related to maintenance. Non-regulated DC EV supply equipment is not covered by this edition

Status
Published
Publication Date
13-Aug-2026
Withdrawal Date
10-Oct-2022
Current Stage
6060 - Document made available - Publishing
Start Date
14-Aug-2026
Due Date
14-Aug-2026
Completion Date
14-Aug-2026

Buy Documents

Standard

EN IEC 61851-23-1:2026 - BARVE

English language (147 pages)
Preview
Preview
e-Library read for
×1 day

EN IEC 61851-23-1:2026 is a CENELEC European Standard for DC electric vehicle supply equipment with an Automated connection device (ACD). It specifies the conductive charging interface, control communication, protection functions, construction rules, and test methods for ACD-based DC charging systems. The standard is aimed at EVSE designers, vehicle engineers, safety specialists, test laboratories, and buyers who need a common technical basis for matching equipment.

What does EN IEC 61851-23-1:2026 specify?

EN IEC 61851-23-1:2026 covers DC EV supply equipment with an ACD for conductive connection to the vehicle, with rated supply voltage up to 1 000 V AC or 1 500 V DC and rated output voltage up to 1 500 V DC. It applies to category 2 automatic couplers and focuses on the power and signalling interface needed for automatic mating, charging, and disconnection.

The document is organized into Clauses 1 to 16, plus Clauses 101, 102, and 201 for added requirements and test methods. Its annexes separate the different system cases, communication processes, test methods, and design considerations.

AnnexTypeWhat it covers
AANormativeSystem A EV supply equipment; marked not applicable in this part
BBNormativeSystem B EV supply equipment with an automated connection device
CCNormativeSystem C EV supply equipment with an automated connection device
DDInformativeBidirectional power transfer control
EENormativeTest load impedance verification
FFNormativeMulti-side B separated EV supply equipment
GGInformativeCommunication and energy transfer process between the EV supply equipment and the EV
HHInformativeTouch current and touch impulse current
AAAInformativeConsiderations when a road vehicle is interconnected with an off-board charger
BBBNormativeSystem C with 3 contacts automatic coupler

What are the key requirements of EN IEC 61851-23-1:2026?

EN IEC 61851-23-1:2026 sets the interface, safety, and control rules for ACD-based DC charging and then adds annex-specific sequences for system B, system C, and the 3-contact variant. In practice, it tells the designer when the charger may move, when it may energize, how it must communicate, and how it must shut down.

Application, control, and charging functions

  • Clause 5 classifies the ACD position as case D or case E. This matters because the moving part can be on the EV supply equipment or on the EV, and the later interface rules depend on that choice.
  • Clause 6 keeps the Mode 4 charging functions and adds ACD-specific checks such as continuity checking of the protective conductor, verification that the EV is properly connected, latching verification, control circuit supply integrity, user-initiated shutdown, voltage limitation, and shutdown of the DC EV supply equipment. For an implementation team, this means the charger must prove that the connection is safe before transfer starts and must stop in a controlled way when the session ends or a fault appears.
  • Clause 7 provides the basic communication interface, while the digital communication for DC charging is taken from ISO 15118-20 and IEC 61851-24. That means charging is controlled by messages, not only by contact state.

Safety, interface, and fault behavior

  • Clause 8 adds protection against electric shock, including basic insulation by air, protection by clearance standing surface, protection by obstacles, and protection by electro-sensitive equipment (ESPE). The practical point is that the physical layout, sensing, and discharge strategy around the live contacts must be verified, not assumed.
  • Clause 9 links the conductive interface to IEC 63407 for the relevant ACD cases and says the automatic couplers are not intended for breaking under load in normal operation. If disconnection under load can occur, the design must avoid hazardous conditions.
  • Clause 13 limits the short-circuit behavior of the DC connection during energy transfer, and Clause 14 says case D and case E equipment shall not provide automatic or remote reclosing of protective devices. Clause 15 adds an emergency switch according to ISO 13850 for case D and case E. In practice, the charger must stay safely open after a fault and give the operator a deliberate emergency stop path.

Construction, marking, verification, and ACD-specific control

  • Clause 12 covers enclosure protection, dielectric withstand, and insulation-bridging components, and it requires relevant surge protective devices to meet the stated DC withstand capability. This is the part used to check that the hardware can survive the electrical environment.
  • Clause 16 requires hazardous voltage marking around the ACD so it is recognizable before direct contact. For installers and integrators, that affects the visible safety layout around the coupler.
  • Clause 101 adds operating limits and ripple checks at side B, including current ripple, voltage ripple, and terminal temperature limits. Clause 102 gives the test setup and load conditions used to verify those behaviors.
  • Clause 201 requires pairing and position verification before a case D ACD moves, requires the ACD to return to home position after a session, blocks a new energy transfer session while the ACD is not at home, and requires emergency shutdown and return home on loss of actuator power or welded disconnection detection. That keeps the moving mechanism from creating a traffic or contact hazard.

Annex-specific system behavior

  • Annex BB gives the detailed control pilot circuit, U-state handling, forward power transfer, error shutdown, emergency shutdown, insulation checks, and inrush current testing for system B.
  • Annex CC gives the full process for system C, including normal start-up, normal shutdown, overvoltage handling, insulation resistance checks, and emergency shutdown timing.
  • Annex BBB adapts system C for a 3-contact automatic coupler, including wireless signaling, message mapping, ground level ACD behavior, and sequence tests for that architecture.

What terms does EN IEC 61851-23-1:2026 define?

EN IEC 61851-23-1:2026 defines the ACD terms that frame the moving parts, positions, and safety devices used in the charging process.

  • automated connection device (ACD) - the active device that makes the physical electromechanical connection without user interaction.
  • ACD counterpart - the passive mating part that works with the ACD to complete the connection.
  • automatic coupler - the system made up of the ACD and the ACD counterpart.
  • case D - a connection where the ACD is on the EV supply equipment.
  • case E - a connection where the ACD is on the EV.
  • ground level automated connection device (glACD) - an ACD located at ground level.
  • electro-sensitive protection equipment (ESPE) - sensing and control equipment used for protective tripping or presence sensing.
  • charging device status - the ACD state, described as home, moving, or end position.

Who uses EN IEC 61851-23-1:2026?

EN IEC 61851-23-1:2026 is used by people who design, integrate, test, or buy DC charging equipment with an ACD. It is relevant to EVSE manufacturers, vehicle OEMs, coupler and connector suppliers, safety engineers, and test laboratories.

In practice, these users apply it to define the interface, check compatibility between the EV and the charger, verify shutdown timing and insulation behavior, and confirm that the moving coupler, communication, and protective functions work together. Procurement and quality teams use it to specify what an ACD-based charging system must include before approval or acceptance.

Which standards are used with EN IEC 61851-23-1:2026?

EN IEC 61851-23-1:2026 relies on a small group of charging, safety, installation, and communication standards.

Standard(s)What they contribute
EN IEC 61851-23 and EN IEC 61851-1Base EV conductive charging framework and shared requirements
IEC 61851-24 and ISO 15118-20Digital communication for DC charging control
IEC 63407Contact interface for the ACD and ACD counterpart
IEC 61851-21-2EMC requirements for DC EV charging equipment
IEC 60364-4-41 and IEC 60364-5-53Low-voltage protection, isolation, switching, control, and monitoring
IEC 60479-1 and IEC 60479-2Effects of current on humans and livestock, used for touch-current considerations
IEC 60529, IEC 61496, IEC 61643, IEC 62368-1Enclosure protection, ESPE, surge protection, and insulation-bridging component safety
ISO 5474-3, ISO 6469-3, ISO 13849-1, ISO 13850, ISO 13855, ISO 7010, ISO 15118-8Vehicle-side safety, risk assessment, emergency stop, safeguard positioning, signs, and wireless communication

What does the EN IEC 61851-23-1:2026 document contain?

EN IEC 61851-23-1:2026 contains the control-pilot circuits, state tables, sequence diagrams, and test setups needed to verify an ACD-based DC charging system. It uses figures and tables to show case D and case E connections, system C test setups, shutdown sequences, insulation checks, ripple limits, and ACD status behavior.

Annex BB and Annex CC provide the main sequence logic for charging and shutdown, while Annex BBB adds the 3-contact variant with wireless signaling and message mapping. Annex HH contains the touch-current and touch-impulse-current design verification method, and Annex AAA explains integration issues when the vehicle and off-board charger are designed under different standards.

Relations

Effective Date
28-Jul-2026
Effective Date
28-Jul-2026
Effective Date
28-Jul-2026
Effective Date
28-Jul-2026
Effective Date
28-Jul-2026
Effective Date
28-Jul-2026
Effective Date
28-Jul-2026
Effective Date
28-Jul-2026
Effective Date
28-Jul-2026
Effective Date
28-Jul-2026
Effective Date
28-Jul-2026
Effective Date
28-Jul-2026
Effective Date
28-Jul-2026
Effective Date
14-Jul-2026
Effective Date
10-Nov-2026

Buy Documents

Standard

EN IEC 61851-23-1:2026 - BARVE

English language (147 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

TÜV Rheinland

TÜV Rheinland is a leading international provider of technical services.

DAKKS Germany Verified

TÜV SÜD

TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.

DAKKS Germany Verified

DEKRA Certification Inc.

DEKRA US certification services.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

EN IEC 61851-23-1:2026 is a standard published by CLC. Its full title is "Electric vehicle conductive charging system - Part 23-1: DC electric vehicle supply equipment - Automated connection device". This standard covers: This part of the IEC 61851 series, together with [IEC 61851-1 Ed. 3] and [IEC 61851-23 Ed 2.0]1, gives the requirements for DC electric vehicle charging stations with an Automated connection device (ACD) for conductive connection to the vehicle, with a rated supply voltage up to 1 000 V AC or up to 1 500 V DC and a rated output voltage up to 1 500 V DC. NOTE 1 This standard includes information on EV for conductive connection, but limited to the necessary content for describing the power and signalling interface. This part specifies the DC charging systems with an Automated connection device based on - system A described in Annex AA of [IEC 61851-23 Ed 2.0]. - system B described in Annex BB of [IEC 61851-23 Ed 2.0]. - system C described in Annex CC of [IEC 61851-23 Ed 2.0]. EMC requirements for DC EV charging stations are defined in [IEC 61851-21-2 Ed. 1 CDV]. This standard provides the general requirements for the control communication between a DC EV charging station and an EV. The requirements for digital communication between DC EV charging station and electric vehicle for control of DC charging are defined in [ISO15118-20 DIS] and [IEC 61851-24 Ed 2.0 CD]. This part only applies to Automatic couplers of category 2: using an electro-mechanical interface defined by [EN50696] for Systems described in Annex CC and Annex KK. System A, B are under consideration. This part does not apply for Automatic coupler of category 1: using a vehicle coupler defined by IEC 62196-2 or IEC 62196-3. This standard does not cover all safety aspects related to maintenance. Non-regulated DC EV supply equipment is not covered by this edition

This part of the IEC 61851 series, together with [IEC 61851-1 Ed. 3] and [IEC 61851-23 Ed 2.0]1, gives the requirements for DC electric vehicle charging stations with an Automated connection device (ACD) for conductive connection to the vehicle, with a rated supply voltage up to 1 000 V AC or up to 1 500 V DC and a rated output voltage up to 1 500 V DC. NOTE 1 This standard includes information on EV for conductive connection, but limited to the necessary content for describing the power and signalling interface. This part specifies the DC charging systems with an Automated connection device based on - system A described in Annex AA of [IEC 61851-23 Ed 2.0]. - system B described in Annex BB of [IEC 61851-23 Ed 2.0]. - system C described in Annex CC of [IEC 61851-23 Ed 2.0]. EMC requirements for DC EV charging stations are defined in [IEC 61851-21-2 Ed. 1 CDV]. This standard provides the general requirements for the control communication between a DC EV charging station and an EV. The requirements for digital communication between DC EV charging station and electric vehicle for control of DC charging are defined in [ISO15118-20 DIS] and [IEC 61851-24 Ed 2.0 CD]. This part only applies to Automatic couplers of category 2: using an electro-mechanical interface defined by [EN50696] for Systems described in Annex CC and Annex KK. System A, B are under consideration. This part does not apply for Automatic coupler of category 1: using a vehicle coupler defined by IEC 62196-2 or IEC 62196-3. This standard does not cover all safety aspects related to maintenance. Non-regulated DC EV supply equipment is not covered by this edition

EN IEC 61851-23-1:2026 is classified under the following ICS (International Classification for Standards) categories: 43.120 - Electric road vehicles. The ICS classification helps identify the subject area and facilitates finding related standards.

EN IEC 61851-23-1:2026 has the following relationships with other standards: It is inter standard links to EN IEC 61496-2:2020, EN IEC 62368-1:2024, EN IEC 61643-11:2025, EN IEC 61496-1:2020, EN IEC 61496-3:2019, ISO 6469-3:2021, EN IEC 61496-3:2025, EN IEC 61643-21:2026, EN IEC 61851-1:2019, IEC 60364-4-41:2005/AMD1:2017, IEC 60364-5-53:2019, HD 60364-4-41:2017, EN IEC 61851-24:2024, EN IEC 61851-23:2026, EN IEC 63407:2026. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN IEC 61851-23-1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 electric supply equipment
  • 3.7 General terms
  • 4 General requirements
  • 5 Classification
  • 6 Charging modes and functions
  • 7 Communications
  • 8 Protection against electric shock
  • 9 Conductive electrical interface requirements
  • 9.1 General
  • 9.4 Functional description of the universal interface
  • 9.5 Functional description of a DC interface
  • 9.6 Functional description of the combined interface
  • 9.7 Wiring of the neutral conductor
  • 10 Requirements for adaptors
  • 11 Cable assembly requirements
  • 12 EV supply equipment constructional requirements and tests
  • 12.4 IP degrees
  • 12.7 Dielectric withstand voltage
  • 13 Overload and short circuit protection
  • 14 Automatic reclosing of protective devices
  • 15 Emergency switching or disconnect (optional)
  • 16 Marking and instructions
  • 6 I × 4,8 %
  • 9 I × 7,2 %
  • Annex AA
  • Annex BB
  • Annex BB provides specific requirements for DC EV supply equipment by using an automatic
  • 1.1 A→B 1) Unmated, S1 closed, S2 normal open, S3 (if exist) open Mating
  • 1.2 B→C 1) Mated, U = 9 V Ready to charge
  • 2.1 C→B 1) Charging, U = 6 V EV terminates charging
  • 2.2 B→D1 1) EV supply equipment detects U change from 6 V (C) to 9 V (B) EV supply equipment
  • 3.1 C→D2 1) Charging, U = 6 V EV supply equipment
  • 3.2 D2→D1 1) EV detects U change from 6 V (C) to 1.5 V (D2) EV responses to the
  • 4.1 D1→A 1) Both EV and EV supply equipment confirm terminate charging Leaves working position
  • Annex CC
  • Annex CC provides specific requirements for DC EV supply equipment using an automatic
  • 5 EVSE_max
  • Annex DD
  • Annex EE
  • Annex FF
  • Annex GG
  • Annex HH
  • 5 EVSE_max
  • Bibliography

INTRODUCTION The introduction and commercialisation of electric vehicles have been accelerated in the global market, responding to the global concerns on CO reduction and energy security. Concurrently,

the development of charging infrastructure for electric vehicles has also been expanding. As a complement to the DC EV supply equipment with a vehicle connector, DC supply equipment using an automated connection device is recognized as an alternative solution for electric vehicles, for example buses and trucks.

The international standardization of charging infrastructure with an automated connection device is indispensable for the diffusion of electric vehicles, and this document is developed for the manufacturers' convenience by providing general and basic requirements for DC EV supply equipment using an automatic conductive connection to the vehicle.

SIST EN IEC 61851-23-1:2026

1 Scope

This part of IEC 61851 provides the requirements for DC EV supply equipment with an automated connection device (ACD) for conductive connection to the vehicle, with a rated maximum voltage at side A of up to 1 000 V AC or up to 1 500 V DC and a rated maximum voltage at side B up to 1 500 V DC.

NOTE 1 This document includes information on EV for conductive connection but limited to the necessary content for describing the power and signalling interface.

This document specifies the DC EV supply equipment with an automated connection device based on - system B described in IEC 61851-23:2023, Annex BB, and - system C described in IEC 61851-23:2023, Annex CC.

The requirements for reverse power transfer (RPT) and bidirectional power transfer (BPT) are under consideration and are not specified in this document.

EMC requirements for DC EV supply equipment are defined in IEC 61851-21-2:2018. This document provides the general requirements for the control communication between a DC EV supply equipment and an EV.

The requirements for digital communication between DC EV supply equipment and electric vehicle for control of DC energy transfer are defined in ISO 15118-20:2022 and IEC 61851-24:2023.

This document only applies to automatic couplers of category 2, i.e. using an electromechanical interface: automatic coupler for an automated charging system according to IEC 63407.

This document does not apply to automatic coupler of category 1 as described in IEC TS 61851-27.

This document does not apply to automatic coupler of category 3 as described in IEC TS 61851-26.

This document does not cover all safety aspects related to maintenance. Requirements for systems not providing simple separation or protective separation between side A and side B are under consideration.

Requirements for EV supply equipment without control of current, voltage or power are under consideration.

EV supply equipment in compliance with this document are not intended to provide energy transfer to a single EV with - multiple vehicle connectors of the same EV supply equipment, or - multiple EV supply equipment.

NOTE 2 Requirements for EVs mated to an EV supply equipment are specified in the ISO 5474 series.

SIST EN IEC 61851-23-1:2026

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

IEC 60364-4-41:2005, Low-voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock IEC 60364-4-41:2005/AMD1:2017 IEC 60364-5-53:2019, Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Devices for protection for safety, isolation, switching, control and monitoring IEC 60364-5-53:2019/AMD2:2024 IEC 60479-1:2018, Effects of current on human beings and livestock - Part 1: General aspects IEC 60479-2:2019, Effects of current on human beings and livestock - Part 2: Special aspects IEC 60529, Degrees of protection provided by enclosures (IP Code) IEC 61496 (all parts), Safety of machinery - Electro-sensitive protective equipment IEC 61643 (all parts), Low-voltage surge protective devices IEC 61643-11, Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods IEC 61643-21, Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Requirements and testing methods IEC 61851-1:2017, Electric vehicle conductive charging system - Part 1: General requirements IEC 61851-23:2023, Electric vehicle conductive charging system - Part 23: DC electric vehicle supply equipment IEC 61851-24:2023, Electric vehicle conductive charging system - Part 24: Digital communication between a DC EV supply equipment and an electric vehicle for control of DC charging IEC 62368-1:2023, Audio/video, information and communication technology equipment - Part 1:Safety requirements IEC 63407:—, Conductive charging of electric vehicles - Contact

interface for automated connection device (ACD) ISO 5474-3:2024, Electrically propelled road vehicles - Functional and safety requirements for power transfer between vehicle and external electric circuit - Part 3 DC power transfer ISO 6469-3:2021, Electrically propelled road vehicles - Safety specifications - Part 3: Electrical safety

Under preparation. Stage at the time of publication: IEC/ACDV 63407:2025.

SIST EN IEC 61851-23-1:2026

ISO 7010, Graphical symbols - Safety colours and safety signs - Registered safety signs, available at https://www.iso.org/obp ISO 13849-1, Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design ISO 13850, Safety of machinery - Emergency stop function - Principles for design ISO 13855, Safety of machinery - Positioning of safeguards with respect to the approach speeds of parts of the human body ISO 15118-2:2014, Road vehicles - Vehicle-to-grid communication interface - Part 2: Network and application protocol requirements ISO 15118-3:2015, Road vehicles - Vehicle to grid communication interface - Part 3: Physical and data link layer requirements ISO 15118-8:2020, Road vehicles - Vehicle to grid communication interface - Part 8: Physical layer and data link layer requirements for wireless communication nd ISO 15118-20:2022, Road vehicles - Vehicle to grid communication interface - Part 20: 2 generation network layer and application layer requirements

3 Terms and definitions

For the purposes of this document, the terms and definitions given in IEC 61851-23:2023 apply, except as follows.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • IEC Electropedia: available at https://www.electropedia.org/
  • ISO Online browsing platform: available at https://www.iso.org/obp

3.1 electric supply equipment

Additional terms and definitions:

3.1.201 case D connection of an EV to a supply network utilizing an automatic coupler which has an ACD on the EV supply equipment Note 1 to entry: See Figure 201 for an example of case D connection.

SIST EN IEC 61851-23-1:2026

Key a automated connection device b ACD counterpart c automatic coupler NOTE The position of the ACD is an example implementation.

Figure 201 – Case D connection 3.1.202 case E connection of an EV to a supply network utilizing an automatic coupler which has an ACD on the EV Note 1 to entry: See Figure 202 for an example of case E connection.

Key a automated connection device b ACD counterpart c automatic coupler NOTE The position of the ACD is an example implementation.

Figure 202 – Case E connection

SIST EN IEC 61851-23-1:2026

3.1.203 automated connection device ACD active device where the physical connection providing an electromechanical interface between the EV supply equipment and the vehicle is made without user interaction 3.1.204 ACD counterpart passive device which is used in combination with an ACD to make the physical connection providing an electromechanical interface between the EV supply equipment and the vehicle without user interaction 3.1.205 automatic coupler system comprising an ACD and an ACD counterpart 3.1.206 mechanical disconnection physical disconnection between ACD and ACD counterpart 3.1.207 ground level automated connection device glACD automated connection device located on ground level 3.1.208 electro-sensitive protection equipment ESPE assembly of either devices or components, or both working together for protective tripping or presence-sensing purposes and comprising as a minimum - a sensing device, - controlling/monitoring devices, and - output signal switching devices or a safety-related data interface, or both Note 1 to entry: The safety-related control system associated with the ESPE, or the ESPE itself, can further include a secondary switching device, muting functions, stopping performance monitor, etc. (see IEC 61496-1:2020, Annex A).

Note 2 to entry: A safety-related communication interface can be integrated in the same enclosure as the ESPE. [SOURCE: IEC 61496-1:2020, 3.5, modified – The expression "and/or" has been clarified in the definition, and "may" has been replaced with "can" in Note 1 to entry.] 3.1.209 charging device status state of the ACD:

  • home (signal 1: active as defined in IEC 63407): position where the ACD is not engaged with its counterpart and where safe clearance is present with street and infrastructure;
  • moving (signal 1 and signal 2 are inactive): ACD is between home and end position;
  • end position (signal 2: active as defined in IEC 63407): position reached when the ACD and the fixed ACD counterpart have mated and when the physical contact is established, and energy transfer is allowed.

SIST EN IEC 61851-23-1:2026

3.7 General terms

Additional terms and definitions:

3.7.201 arm's reach zone of accessibility to touch extending from any point on a surface where persons usually stand or move about to the limits which a person can reach with the hand, in any direction, without assistance [SOURCE: IEC 60050-826:2022, 826-12-19, modified – The note to entry has been deleted.] 3.7.202 EV contactor contactor of the EV that connect the automatic coupler with the EV DC− bus 3.7.203 EV supply equipment contactor contactor of the EV supply equipment that connect the automatic coupler with the EV supply equipment DC− bus 3.7.204 automatic coupler of category 1 ACD using a vehicle connector and a vehicle plug specified within IEC 62196-2, IEC 62196-3 or IEC TS 63379 as specified in IEC TS 61851-27 3.7.205 automatic coupler of category 2 automatic coupler for an automated charging system according to IEC 63407 3.7.206 automatic coupler of category 3 automatic coupler for an automated charging system according to IEC TS 61851-26 Note 1 to entry: IEC TS 61851-26 specifies the use of automatic coupler for both AC and DC charging.

4 General requirements

IEC 61851-23:2023, Clause 4, is applicable.

5 Classification

IEC 61851-23:2023, Clause 5, is applicable except as follows.

Addition:

5.201 Position of the ACD - case D; - case E.

SIST EN IEC 61851-23-1:2026

6 Charging modes and functions

IEC 61851-23:2023, Clause 6, is applicable except as follows.

6.3 Functions provided in Mode 4 6.3.1 Mandatory functions in Mode 4

6.3.1.1 General

Replacement:

The EV supply equipment shall supply a DC current or voltage to the EV battery system in accordance with a EVCC request.

The following functions shall be provided by EV supply equipment:

  • continuous continuity checking of the protective conductor according to 6.3.1.2;
  • verification that the EV is properly connected to the EV supply equipment according to 6.3.1.3;
  • energization of the power supply to the EV according to 6.3.1.4;
  • de-energization of the power supply to the EV according to 6.3.1.5;
  • maximum allowable current according to 6.3.1.6;
  • DC supply for EV according to 6.3.1.101;
  • measuring current and voltage according to 6.3.1.102;
  • compatibility check according to 6.3.1.104;
  • insulation resistance check before energy transfer according to 6.3.1.104;
  • protection against overvoltage between DC+ and DC− according to 6.3.1.107;
  • control circuit supply integrity according to 6.3.1.108;
  • short circuit check before energy transfer according to 6.3.1.109;
  • user initiated shutdown according to 6.3.1.109;
  • overload protection for parallel conductors (conditional function) according to 6.3.1.111;
  • voltage limitation between side B live parts (DC+ and DC−) and protective conductor according to 6.3.1.111.
  • shutdown of EV supply equipment according to 6.3.1.113.

The EV manufacturer should consider the requirements for overvoltage and overcurrent according to this document and ISO 5474-3.

If the EV supply equipment can supply more than one EV simultaneously, the EV supply equipment shall provide all functions listed above independently at each vehicle connector.

SIST EN IEC 61851-23-1:2026

6.3.1.2 Continuous continuity checking of the protective conductor

Addition:

For systems with a case D or case E connection, protective conductor continuity between the EV supply equipment and the EV shall be monitored. For the rated voltage of 60 V DC or higher, the EV supply equipment shall trigger an emergency shutdown after the electrical continuity of protective conductor between EV supply equipment and EV is lost for 20 ms or more. The EV supply equipment can trigger an emergency shutdown when the electrical continuity of protective conductor between EV supply equipment and EV is lost for less than 20 ms. NOTE 6.3.1.2 addresses only the continuity measurement between the DC EV supply equipment and the vehicle. The impedance level of the protective conductor connection is not addressed.

6.3.1.3 Verification that the EV is properly connected to the EV supply equipment

Replacement:

The EV supply equipment shall be able to determine that the EV is properly connected to the EV supply equipment.

Proper connection is assumed when the continuity of the control pilot circuit is detected and ACD has reached end position.

NOTE Signal 2 is defined in IEC 63407 .

6.3.1.103 Latching of the vehicle connector IEC 61851-23:2023, 6.3.1.103, is not applicable.

6.3.1.106 Protection against overvoltage at side B between DC+ and DC− 6.3.1.106.2 Protection against overvoltage at side B between DC+ and DC− by emergency shutdown Replacement, in the second paragraph, of "Table 103" with "Table 201". Table 103 – Voltage threshold for emergency shutdown reaction for system B and system C Replacement:

Table 201 – Voltage threshold for emergency shutdown reaction for system B and system C Negotiated maximum voltage at side B Voltage threshold (U) V U ≤ 500 V 550 500 V < U ≤ 750 V 825 750 V < U ≤ 850 V 935 850 V < U ≤ 1 000 V 1 100 1 000 V < U ≤ 1 250 V 1 375

Under preparation. Stage at the time of publication: IEC/ACDV 63407:2025.

SIST EN IEC 61851-23-1:2026

6.3.1.107 Verification of vehicle connector latching IEC 61851-23:2023, 6.3.1.107, is not applicable.

6.3.1.108 Control circuit supply integrity st Replacement of the 1 paragraph:

If an earth fault, short circuit or overcurrent is detected at side B, the power supply for the control circuit of the EV supply equipment shall not be interrupted until the forward power transfer (FPT) sequence is completed.

6.3.1.110 User initiated shutdown Replacement:

The EV supply equipment can have means to allow the user to initiate the normal shutdown. If such means are provided, compliance is checked for system C by the tests in CC.7.5.20. For system B, the test is under consideration.

6.3.1.112 Voltage limitation between side B live parts (DC+ and DC−) and protective conductor 6.3.1.112.2 Maximum voltage between side B live parts (DC+ and DC−) and protective conductor in case of an insulation fault at side B to the protective conductor Addition:

For EV supply equipment based on case 3, with a rated maximum voltage of the EV supply equipment at side B of > 1 000 V DC and ≤ 1 250 V DC: if a voltage more than 110 % of the present voltage at side B between DC+ and DC− is present for more than 1 s between side B live parts (DC+/DC−) and the protective conductor, the EV supply equipment shall trigger and complete an error shutdown in 4 s or less. See Figure 105.

For EV supply equipment based on case 3, with a rated maximum voltage of the EV supply equipment at side B of > 1 000 V DC and ≤ 1 250 V DC: if a voltage more 1 250 V is present for more than 1 s between side B live parts (DC+/DC−) and the protective conductor, the EV supply equipment shall trigger and complete an error shutdown in 4 s or less. See Figure 105. 6.3.1.113 Shutdown of DC EV supply equipment 6.3.1.113.3 Error shutdown Addition:

After the error shutdown is triggered, the ACD shall disconnect and go to home position. NOTE Detecting an isolation error is considered a trigger for an error shutdown.

SIST EN IEC 61851-23-1:2026

6.3.1.113.4 Emergency shutdown Replacement:

After the emergency shutdown is triggered by the EV supply equipment, the EV supply equipment shall reduce - the present current at side B ≤ 5 A within 70 ms, and - maintain the present voltage at side B ≤ 60 V between DC+ and DC−, between DC+ and the protective conductor, and DC− and the protective conductor in 1 s or less for system B, and in 80 ms or less for system C.

NOTE 1 The timing can only be met if the vehicle disconnection devices are opened and the capacitance between DC+ and DC− in the vehicle (between interface and contactors) is negligible. After the emergency shutdown is triggered, the ACD shall disconnect and go to home position. NOTE 2 Pressing the emergency stop button is considered a trigger for an emergency shutdown. Further requirements are specified in IEC 61851-23:2023, AA.4.3.5.3, BB.5.1, CC.3.4, and BBB.3.4 of this document.

NOTE 3 A welded contactor on the vehicle can prevent the EV supply equipment to reduce the voltage. Compliance for system B is checked by the following test. Compliance for system C is checked by CC.7.5.4 or BBB.7.5.4.

The test system is shown in IEC 61851-23:2023, Figure 129.

The test shall be performed according to the following procedure. 1) Connect the EV supply equipment to a test load with dedicated EV simulator with a test load for each system.

2) Start energy transfer with the procedure specified by the EV supply equipment manufacturer.

3) Confirm that V 8 is at the rated maximum voltage of the EV supply equipment at side B T and the EV supply equipment is operating at the rated maximum current at side B. 4) Open the relay for system B: S 4.

T 5) The EV supply equipment shall trigger and complete an emergency shutdown, displaying a relevant alarm or error information, if any, according to BB.5.1 and Table BB.203 for system B.

6.3.2 Optional functions for Mode 4

6.3.2.3 Intentional and unintentional disconnection of the vehicle connector and/or the

EV plug IEC 61851-1:2017, 6.3.2.3, is not applicable.

6.3.2.4 Mode 4 using the combined charging system

IEC 61851-1:2017, 6.3.2.4, is not applicable.

7 Communications

IEC 61851-23:2023, Clause 7, is applicable except as follows.

SIST EN IEC 61851-23-1:2026

7.1.101 Basic communication interface Replacement:

Typical interfaces of control pilot function on DC EV supply equipment are specified in Annex BB, Annex CC and Annex BBB. Each system shall carry out control pilot function through the control pilot conductors and terminals specified in IEC 63407.

8 Protection against electric shock

IEC 61851-23:2023, Clause 8, is applicable except as follows.

8.101 General provisions 8.101.2 Intended use and reasonably foreseeable misuse Replacement:

...