EN 61803:1999/A1:2010
(Amendment)Determination of power losses in high-voltage direct current (HVDC) converter stations with line-commutated converters
Determination of power losses in high-voltage direct current (HVDC) converter stations with line-commutated converters
Amandma A1:2011 je dodatek k standardu SIST EN 61803:2001
Applies to all line-commutated high-voltage direct current (HVDC) converter stations used for power exchange in utility systems. This standard presimes the use of 12-puls thyristor converters but can, with due care, also be used for 6-pulse thyristor converters.
Bestimmung der Leistungsverluste in Hochspannungsgleichstrom- (HGÜ-)Stromrichterstationen mit netzgeführten Stromrichtern
Détermination des pertes en puissance dans les postes de conversion en courant continu à haute tension (CCHT) munis de convertisseurs commutés par le réseau
Ugotavljanje močnostnih izgub v visokonapetostnih enosmernih pretvornikih (HVDC) z vodovno komutiranimi pretvorniki - Dopolnilo A1 (IEC 61803:1999/A1:2010)
Amandma A1:2011 je dodatek k standardu SIST EN 61803:2001
Velja za vse vodovno komutirane visokonapetostne enosmerne (HVDC) pretvornike, ki se uporabljajo za izmenjavo električne energije v javnih sistemih. Ta standard predvideva uporabo 12-pulznih tiristorksih pretvornikov, vendar se lahko uporablja tudi za 6-pulzne tiristorske pretvornike ob ustrezni previdnosti.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-2011
8JRWDYOMDQMHPRþQRVWQLKL]JXEYYLVRNRQDSHWRVWQLKHQRVPHUQLKSUHWYRUQLNLK
+9'&]YRGRYQRNRPXWLUDQLPLSUHWYRUQLNL'RSROQLOR$,(&
$
Determination of power losses in high-voltage direct current (HVDC) converter stations
with line-commutated converters (IEC 61803:1999/A1:2010)
Bestimmung der Leistungsverluste in Hochspannungsgleichstrom-(HGÜ-)
Stromrichterstationen mit netzgeführten Stromrichtern (IEC 61803:1999/A1:2010)
Détermination des pertes en puissance dans les postes de conversion en courant
continu à haute tension (CCHT) munis de convertisseurs commutés par le réseau (CEI
61803:1999/A1:2010)
Ta slovenski standard je istoveten z: EN 61803:1999/A1:2010
ICS:
29.200 8VPHUQLNL3UHWYRUQLNL Rectifiers. Convertors.
6WDELOL]LUDQRHOHNWULþQR Stabilized power supply
QDSDMDQMH
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 61803/A1
NORME EUROPÉENNE
December 2010
EUROPÄISCHE NORM
ICS 29.200
English version
Determination of power losses in high-voltage direct current (HVDC)
converter stations with line-commutated converters
(IEC 61803:1999/A1:2010)
Détermination des pertes en puissance Bestimmung der Leistungsverluste in
dans les postes de conversion en courant Hochspannungsgleichstrom-
continu à haute tension (CCHT) munis de (HGÜ-)Stromrichterstationen mit
convertisseurs commutés par le réseau netzgeführten Stromrichtern
(CEI 61803:1999/A1:2010) (IEC 61803:1999/A1:2010)
This amendment A1 modifies the European Standard EN 61803:1999; it was approved by CENELEC on
2010-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61803:1999/A1:2010 E
Foreword
The text of document 22F/214/CDV, future amendment 1 to IEC 61803:1999, prepared by SC 22F,
Power electronics for electrical transmission and distribution systems, of IEC TC 22, Power electronic
systems and equipment, was submitted to the IEC-CENELEC parallel vote and was approved by
CENELEC as amendment A1 to EN 61803:1999 on 2010-12-01.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the amendment has to be
implemented at national level by publication of
an identical national standard or by endorsement (dop) 2011-09-01
– latest date by which the national standards conflicting
with the amendment have to be withdrawn (dow) 2013-12-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of amendment 1:2010 to the International Standard IEC 61803:1999 was approved by
CENELEC as an amendment to the European Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standard indicated:
IEC 61378-2:2001 NOTE Harmonized as EN 61378-2:2001 (not modified).
__________
- 3 - EN 61803:1999/A1:2010
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
Delete the following reference:
IEC 60289 (mod) 1988 Reactors EN 60289 1994
Replace the existing references to IEC 60076-1:1993, IEC 60633:1998, IEC 60700-1:1988,
IEC 60747-6:1983 and IEC 60871-1:1997 as follows:
IEC 60076-1 - Power transformers - EN 60076-1 -
Part 1: General
IEC 60633 - Terminology for high-voltage direct current EN 60633 -
(HVDC) transmission
IEC 60700-1 - Thyristor valves for high voltage direct EN 60700-1 -
current (HVDC) power transmission -
Part 1: Electrical testing
IEC 60747-6 - Semi conductor devices - - -
Part 6: Thyristors
IEC 60871-1 - Shunt capacitors for a.c. power systems EN 60871-1 -
having a rated voltage above 1 000 V -
Part 1: General
Add the following new reference:
IEC 60076-6 2007 Power transformers - Part 6: Reactors EN 60076-6 2008
IEC 61803 ®
Edition 1.0 2010-11
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
AMENDMENT 1
AMENDEMENT 1
Determination of power losses in high-voltage direct current (HVDC) converter
stations with line-commutated converters
Détermination des pertes en puissance dans les postes de conversion en
courant continu à haute tension (CCHT) munis de convertisseurs commutés par
le réseau
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
F
CODE PRIX
ISBN 978-2-88912-272-1
ICS 29.200
– 2 – 61803 Amend.1 Ó IEC:2010
FOREWORD
This amendment has been prepared by subcommittee 22F: Power electronics for electrical
transmission and distribution systems, of IEC technical committee 22: Power electronic
systems and equipment.
The text of this amendment is based on the following documents:
CDV Report on voting
22F/214/CDV 22F/2
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.