Primary batteries - Part 2: Physical and electrical specifications

This part of IEC 60086 is applicable to primary batteries based on standardized electrochemical systems. It specifies - the physical dimensions, - the discharge test conditions and discharge performance requirements.

Primärbatterien - Teil 2: Physikalische und elektrische Spezifikationen

Piles électriques - Partie 2: Spécifications physiques et électriques

Primarne baterije - 2. del: Fizikalne in električne specifikacije (IEC 60086-2:2006)

General Information

Status
Withdrawn
Publication Date
13-Feb-2007
Withdrawal Date
31-Jan-2010
Technical Committee
Drafting Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
24-Mar-2014
Completion Date
24-Mar-2014

Relations

Buy Standard

Standard
EN 60086-2:2007
English language
61 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-december-2007
1DGRPHãþD
SIST EN 60086-2:2002
SIST EN 60086-2:2002/A1:2002
SIST EN 60086-2:2002/A2:2004
3ULPDUQHEDWHULMHGHO)L]LNDOQHLQHOHNWULþQHVSHFLILNDFLMH ,(&
Primary batteries - Part 2: Physical and electrical specifications
Primärbatterien - Teil 2: Physikalische und elektrische Spezifikationen
Piles électriques - Partie 2: Spécifications physiques et électriques
Ta slovenski standard je istoveten z: EN 60086-2:2007
ICS:
29.220.10 3ULPDUQLþOHQLLQEDWHULMH Primary cells and batteries
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 60086-2
NORME EUROPÉENNE
February 2007
EUROPÄISCHE NORM
ICS 29.220.10 Supersedes EN 60086-2:2001 + A1:2001 + A2:2004

English version
Primary batteries –
Part 2: Physical and electrical specifications
(IEC 60086-2:2006)
Piles électriques –  Primärbatterien –
Partie 2: Spécifications physiques Teil 2: Physikalische und elektrische
et électriques Spezifikationen
(CEI 60086-2:2006) (IEC 60086-2:2006)

This European Standard was approved by CENELEC on 2007-02-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60086-2:2007 E
Foreword
The text of document 35/1245/FDIS, future edition 11 of IEC 60086-2, prepared by IEC TC 35, Primary
cells and batteries, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as
EN 60086-2 on 2007-02-01.
This European Standard supersedes EN 60086-2:2001 + A1:2001 + A2:2004.
The major technical changes are the addition of a "digital still camera test" for the LR6 battery, the
reduction, for selected no letter batteries, from three grades (S, C and P) to two grades (S and P) with
appropriate adjustments to MAD values, the deletion of the 3,6 ohm pulse test for the R03 battery, and
the addition of new constant current hearing aid tests (standard and high drain) for the PR41, PR44,
PR48 and PR70 batteries.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2007-11-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2010-02-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60086-2:2006 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60086-4 NOTE Harmonized as EN 60086-4:2000 (not modified).
IEC 60086-5 NOTE Harmonized as EN 60086-5:2005 (not modified).
IEC 62281 NOTE Harmonized as EN 62281:2004 (not modified).
__________
- 3 - EN 60086-2:2007
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
IEC 60050-482 2004 International Electrotechnical Vocabulary - -
(IEV) –
Part 482: Primary and secondary cells and
batteries
1) 2)
IEC 60086-1 - Primary batteries – EN 60086-1 2007
Part 1: General
1) 2)
ISO 1101 - Geometrical Product Specifications (GPS) - EN ISO 1101 2005
Geometrical tolerancing - Tolerances of form,
orientation, location and run-out

1)
Undated reference.
2)
Valid edition at date of issue.

INTERNATIONAL IEC
STANDARD
CEI
60086-2
NORME
Eleventh edition
INTERNATIONALE
Onzième édition
2006-12
Primary batteries –
Part 2:
Physical and electrical specifications

Piles électriques –
Partie 2:
Spécifications physiques et électriques
PRICE CODE
XA
CODE PRIX
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue
Pour prix, voir catalogue en vigueur

– 2 – 60086-2 © IEC:2007
CONTENTS
FOREWORD.4
INTRODUCTION.6

1 Scope.7
2 Normative references .7
3 Terms and definitions .7
4 Symbols and abbreviations.9
5 Battery dimensions, symbols .9
6 Constitution of the battery specification tables.9
7 Physical and electrical specifications.12
7.1 Category 1 batteries .12
7.1.1 Category 1 – Physical and electrical specifications .12
7.1.2 Category 1 – Specifications: R1, R03, R6P, R6S .13
7.1.3 Category 1 – Specifications: R14P, R14S .14
7.1.4 Category 1 – Specifications: R20P, R20S, 2R10, LR8D425, LR1 .15
7.1.5 Category 1 – Specifications: LR03, LR6, LR14, LR20 .17
7.1.6 Category 1 – Specifications: CR12A604 .19
7.2 Category 2 batteries .20
7.2.1 Category 2 – Physical and electrical specifications .20
7.2.2 Category 2 – Specifications: CR14250, CR15H270, CR17345,
CR17450, BR17335.21
7.3 Category 3 batteries .22
7.3.1 Category 3 – Physical and electrical specifications .22
7.3.2 Category 3 – Specifications: LR9, LR53, CR11108 .23
7.4 Category 4 batteries .24
7.4.1 Category 4 – Physical and electrical specifications .24
7.4.2 Category 4 – Specifications: PR70, PR41, PR48, PR44.25
7.4.3 Category 4 – Specifications: LR41, LR55, LR54, LR43, LR44 .29
7.4.4 Category 4 – Specifications: SR62, SR63, SR 65, SR64, SR60, SR67,
SR66, SR58, SR68, SR59, SR69, SR41, SR57, SR55, SR48 .30
7.4.5 Category 4 – Specifications: SR56, SR54, SR42, SR43, SR44 .31
7.4.6 Category 4 – Specifications: CR1025, CR1216, CR1220, CR1616,
CR2012, CR1620, CR2016, CR2025, CR2320, CR2032, CR2330,
CR2430, CR2354, CR3032, CR2450 .32
7.4.7 Category 4 – Specifications: BR1225, BR2016, BR2020, BR2320,
BR2325, BR3032.33
7.5 Category 5 batteries .34
7.5.1 Category 5 – Physical and electrical specifications .34
7.6 Category 6 batteries .37
7.6.1 Category 6 – Physical and electrical specifications .37

Annex A (informative) Tabulation of batteries by application .50
Annex B (informative) Cross-reference index .54
Annex C (informative) Index.57

Bibliography.58

60086-2 © IEC:2007 – 3 –
Figure 1 – Category 1 dimensional drawings.12
Figure 2 – Category 2 dimensional drawing .20
Figure 3 – Category 3 dimensional drawings.22
Figure 4 – Category 4 dimensional drawing .24
Figure 5 – Gauge for Category 4 batteries .28
Figure 6 – Dimensional drawing: R40.34
Figure 7 – Dimensional drawing: 4LR44, 2CR13252, 4SR44 .35
Figure 8 – Dimensional drawing: 5AR40 .36
Figure 9 – Dimensional drawing: S4.37
Figure 10 – Dimensional drawing: 3R12C,3R12P, 3R12S, 3LR12 .38
Figure 11 – Dimensional drawing: 4LR61.39
Figure 12 – Dimensional drawing: CR-P2, BR-P2.40
Figure 13 – Dimensional drawing: 2CR5 .41
Figure 14 – Dimensional drawing: 2EP3863.42
Figure 15 – Dimensional drawing: 4R25X, 4LR25X .43
Figure 16 – Dimensional drawing: 4R25Y .44
Figure 17 – Dimensional drawing: 4R25-2, 4LR25-2 .45
Figure 18 – Dimensional drawing: 6AS4.46
Figure 19 – Dimensional drawing: 6AS6.47
Figure 20 – Dimensional drawing: 6F22, 6LR61 .48
Figure 21 – Dimensional drawing: 6F100 .49

Table A.1 – Road warning lamp .50
Table A.2 – Industrial equipment.50
Table A.3 – Electrical fence controller.50
Table A.4 – Radio .51
Table A.5 – Electronic equipment .51
Table A.6 – Paging test.51
Table A.7 – Hearing aid .51
Table A.8 – Photo .52
Table A.9 – Portable lighting.52
Table A.10 – Smoke detector.52
Table A.11 – Toy (motor) .53
Table A.12 – Accelerated application test for automatic camera.53
Table A.13 – Tape recorder (personal cassette player) .53
Table B.1 – Category 1 batteries.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.