HD 323.2.3 S2:1987
(Main)Basic environmental testing procedures - Part 2: Tests - Test Ca: Damp heat, steady state
- Abstract
Describes a continuous test at a steady temperature of 40°C and a relative humidity of 90-95%. The standard test duration is 4 to 56 days.
- Status
- Withdrawn
- Publication Date
- 31-Mar-2003
- Withdrawal Date
- 31-Mar-2003
- Technical Committee
- CLC/SR 104 - Environmental conditions, classification and methods of test
- Drafting Committee
- TC 104 - Environmental conditions, classification and methods of test
- Parallel Committee
- TC 104 - Environmental conditions, classification and methods of test
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Apr-2003
- Due Date
- 01-Apr-2003
- Completion Date
- 01-Apr-2003
Relations
- Replaced By
EN 60068-2-78:2001 - Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state - Effective Date
- 29-Jan-2023
- Effective Date
- 09-Feb-2026
- Referred By
EN 54-3:2001 - Fire detection and fire alarm systems - Part 3: Fire alarm devices - Sounders - Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Referred By
EN 54-5:2000 - Fire detection and fire alarm systems - Part 5: Heat detectors - Point detectors - Effective Date
- 09-Feb-2026
- Referred By
EN 60694:1996/A2:2001 - Common specifications for high-voltage switchgear and controlgear standards - Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Referred By
EN 61204:1995 - Low-voltage power supply devices, d.c. output - Performance characteristics - Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Referred By
EN 60252:1994 - A.C. motor capacitors - Effective Date
- 03-Feb-2026
Frequently Asked Questions
HD 323.2.3 S2:1987 is a standardization document published by CLC. Its full title is "Basic environmental testing procedures - Part 2: Tests - Test Ca: Damp heat, steady state". This standard covers: Describes a continuous test at a steady temperature of 40°C and a relative humidity of 90-95%. The standard test duration is 4 to 56 days.
Describes a continuous test at a steady temperature of 40°C and a relative humidity of 90-95%. The standard test duration is 4 to 56 days.
HD 323.2.3 S2:1987 has the following relationships with other standards: It is inter standard links to EN 60068-2-78:2001, EN 54-11:2001, EN 54-3:2001, EN 54-7:2000, EN 54-5:2000, EN 60694:1996/A2:2001, EN 60539-1:2002, EN 61131-2:1994, EN 61248-7:1997, EN 61646:1997, EN 61189-3:1997, EN 61204:1995, EN 60868:1993, EN 60512-11-3:2002, EN 60252:1994. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
HD 323.2.3 S2:1987 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI SIST HD 323.2.3 S2:2003
STANDARD
julij 2003
Basic environmental testing procedures - Part 2: Tests - Test Ca: Damp heat,
steady state
ICS 19.040 Referenčna številka
...