Passive RF and microwave devices, intermodulation level measurement - Part 2: Measurement of passive intermodulation in coaxial cable assemblies

IEC 62037-2:2012(E) defines a procedure to measure levels of passive intermodulation generated by a coaxial cable assembly. This test method is applicable to jumper cables, i.e. cable assemblies intended to provide interface flexibility between rigid devices.

Passive HF- und Mikrowellenbauteile, Messung des Intermodulationspegels – Teil 2: Messung der passiven Intermodulation in konfektionierten Koaxialkabeln

Dispositifs RF et à micro-ondes passifs, mesure du niveau d’intermodulation - Partie 2: Mesure de l’intermodulation passive dans les cordons coaxiaux

La CEI 62037-2:2012 définit une procédure pour la mesure des niveaux d'intermodulation passive générés par un cordon coaxial. Cette méthode d'essai s'applique aux jarretières, c'est-à-dire aux cordons destinés à fournir une interface flexible entre des dispositifs rigides.

Pasivne radiofrekvenčne (rf) in mikrovalovne naprave, meritve intermodulacijskega nivoja - 2. del: Meritve pasivne intermodulacije v koaksialnih kabelskih sestavih (IEC 62037-2:2012)

Ta del standarda IEC 62037 določa postopek za merjenje ravni pasivne intermodulacije, ki jo proizvede koaksialni kabelski sestav. Ta preskusna metoda se uporablja za povezovalne vode, tj. kabelske sestave, ki so namenjeni zagotavljanju vmesniške prilagodljivosti med togimi napravami.

General Information

Status
Published
Publication Date
28-Feb-2013
Withdrawal Date
11-Dec-2015
Drafting Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
23-Dec-2024
Completion Date
23-Dec-2024

Relations

Buy Standard

Standard
EN 62037-2:2013 - BARVE
English language
10 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-april-2013
1DGRPHãþD
SIST EN 62037:2001
3DVLYQHUDGLRIUHNYHQþQH UI LQPLNURYDORYQHQDSUDYHPHULWYH
LQWHUPRGXODFLMVNHJDQLYRMDGHO0HULWYHSDVLYQHLQWHUPRGXODFLMHYNRDNVLDOQLK
NDEHOVNLKVHVWDYLK ,(&
Passive r.f. and microwave devices, intermodulation level measurement - Part 2:
Measurement of passive intermodulation in coaxial cable assemblies (IEC 62037-
2:2012)
Passive HF- und Mikrowellenbauteile, Messung des Intermodulationspegels - Teil 2:
Messung der passiven Intermodulation in konfektionierten Koaxialkabeln (IEC 62037-
2:2012)
Dispositifs RF et à micro-ondes passifs, mesure du niveau d’intermodulation - Partie 2:
Mesure de l’intermodulation passive dans les cordons coaxiaux (CEI 62037-2:2012)
Ta slovenski standard je istoveten z: EN 62037-2:2013
ICS:
33.120.10 Koaksialni kabli. Valovodi Coaxial cables. Waveguides
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML R.F. connectors
5)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 62037-2
NORME EUROPÉENNE
March 2013
EUROPÄISCHE NORM
ICS 33.040.20; 33.120.10 Supersedes EN 62037:1999 (partially)

English version
Passive RF and microwave devices, intermodulation level measurement -
Part 2: Measurement of passive intermodulation in coaxial cable
assemblies
(IEC 62037-2:2012)
Dispositifs RF et à micro-ondes passifs, Passive HF- und Mikrowellenbauteile,
mesure du niveau d’intermodulation - Messung des Intermodulationspegels -
Partie 2: Mesure de l’intermodulation Teil 2: Messung der passiven
passive dans les cordons coaxiaux Intermodulation in konfektionierten
(CEI 62037-2:2012) Koaxialkabeln
(IEC 62037-2:2012)
This European Standard was approved by CENELEC on 2012-12-12. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 62037-2:2013 E
Foreword
The text of document 46/408/FDIS, future edition 1 of IEC 62037-2, prepared by IEC/TC 46 "Cables,
wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories" was
submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 62037-2:2013.
The following dates are fixed:
(dop) 2013-09-12
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2015-12-12
• latest date by which the national
standards conflicting with the
document have to be withdrawn
This document partially supersedes EN 62037:1999.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent
rights.
Endorsement notice
The text of the International Standard IEC 62037-2:2012 was approved by CENELEC as a European
Standard without any modification.

- 3 - EN 62037-2:2013
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year

IEC 62037-1 2012 Passive RF and microwave devices, EN 62037-1 2012
intermodulation level measurement -
Part 1: General requirements and measuring
methods
IEC 62037-2 ®
Edition 1.0 2012-11
INTERNATIONAL
STANDARD
colour
inside
Passive RF and microwave devices, intermodulation level measurement –

Part 2: Measurement of passive intermodulation in coaxial cable assemblies

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
G
ICS 33.040.20 ISBN 978-2-83220-475-7
33.120.10
– 2 – 62037-2 © IEC:2012(E)
CONTENTS
FOREWORD . 3
1 Scope . 5
2 Normative references . 5
3 Abbreviations . 5
4 Test set-up . 5
5 Procedure . 7
6 Report . 7

Figure 1 – PIM test set-up example . 6
Figure 2 – Rotation of cable . 6

Table 1 – Minimum requirement of cable parameters . 7

62037-2 © IEC:2012(E) – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
PASSIVE RF AND MICROWAVE DEVICES,
INTERMODULATION LEVEL MEASUREMENT –

Part 2: Measurement of passive intermodulation
in coaxial cable assemblies
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publ
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.