Status
Not Published
Publication Date
23-Mar-2028
Technical Committee
CLC/SR 29 - Electroacoustics
Current Stage
4020 - Enquiry circulated - Enquiry
Start Date
16-Oct-2026
Due Date
31-Aug-2026
Completion Date
31-Aug-2026

Buy Documents

Draft

prEN IEC 60942:2026

English language (51 pages)
Preview
Preview
e-Library read for
×1 day

prEN IEC 60942:2026 is a CENELEC draft based on IEC 60942 for electroacoustics - sound calibrators. It specifies performance requirements, classes, test methods, marking and documentation for sound calibrators used with specified microphone types and configurations in laboratory and field calibration work.

What does prEN IEC 60942:2026 specify?

prEN IEC 60942:2026 specifies the performance of sound calibrators that generate a sinusoidal sound pressure of specified level and frequency when coupled to specified microphones in specified configurations. It covers class LS, class 1 and class 2 instruments, and it also includes normative pattern evaluation tests and periodic tests.

The scope is focused on sound calibrators used to determine microphone electroacoustical pressure sensitivity and to check or adjust the sensitivity of acoustical measuring devices or systems. It does not cover equivalent free-field or random-incidence sound pressure levels, and it does not include requirements for other functions such as tonebursts.

The document is organized into:

  • Clause 1 Scope
  • Clause 2 Normative references
  • Clause 3 Terms and definitions
  • Clause 4 Reference environmental conditions
  • Clause 5 Requirements
  • Clause 6 Instrument marking and documentation
  • Annex A Pattern evaluation tests
  • Annex B Periodic tests
  • Annex C Relationship between tolerance interval, acceptance interval and maximum-permitted uncertainty of measurement
  • Annex D Example assessments of conformance to specifications
AnnexWhat it covers
Annex ATests used to demonstrate conformance for a model or pattern of sound calibrator
Annex BPeriodic tests for sound calibrators already in use
Annex CHow acceptance limits and measurement uncertainty relate in conformity assessment
Annex DWorked examples of conformance assessment

What are the key requirements of prEN IEC 60942:2026?

prEN IEC 60942:2026 sets out the main performance requirements for sound calibrators, the conditions under which they are measured, and the information that must be supplied with them. In practice, the standard tells manufacturers what to design, test laboratories what to measure, and users what information must appear on the instrument and in its manual.

Classes, principal values and intended use

Clause 5 defines three classes - LS, 1 and 2 - with the smallest acceptance limits for class LS and the largest for class 2. Class LS sound calibrators are normally laboratory instruments, while class 1 and class 2 sound calibrators are intended for field use; class 1 aligns mainly with class 1 sound level meters and class 2 with class 2 sound level meters and personal sound exposure meters.

Where a sound calibrator provides more than one sound pressure level or frequency, the manufacturer identifies a principal sound pressure level and a principal frequency. Those principal values are the ones used for demonstrating conformance, so they matter whenever a model has multiple operating settings.

Reference environmental conditions and operating ranges

Clause 4 states the reference environmental conditions used for specification: 23 °C air temperature, 101,325 kPa static pressure and 50 % relative humidity. Clause 5.6 then gives the environmental ranges over which the sound calibrator must still meet the relevant limits, with different ranges for class LS, class 1 and class 2.

This matters because the same calibrator may be used in different climates or altitude conditions. If the model is designated LS/M or 1/M, the document allows use of static-pressure correction data, and the instruction manual has to include the correction information and its associated measurement uncertainty.

Sound pressure level, frequency and distortion

Clause 5.3 specifies acceptance limits for sound pressure level, short-term level fluctuation and the effect of supply voltage. Clause 5.4 specifies the frequency of the sound generated by the calibrator, and Clause 5.5 limits total distortion + noise over the relevant frequency range.

In practice, these clauses define the core output quality of the calibrator: the level must be stable, the frequency must stay within limits, and unwanted distortion and noise must remain low enough to avoid affecting microphone calibration. Tables 2 to 5 give the acceptance limits for these checks, and Tables 6 and 7 extend the limits to environmental conditions outside the reference condition.

Adaptors, microphones and power supply

Clause 5.2 treats adaptors as integral parts of the sound calibrator when they are provided for use with transfer standard or laboratory standard microphones. If adaptor design data are supplied, the manual has to include the details needed to reproduce an adaptor that preserves the declared performance class.

Clause 5.7 requires a means of indicating that the supply voltage is sufficient, or a design that stops sound output when the voltage falls below the usable limit. Clause 5.8 ties the test microphone to the calibrator class: class LS uses a laboratory standard microphone, while class 1 and class 2 use the microphone type and configuration identified in the manual.

Electromagnetic compatibility and marking

Clause 5.9 sets electromagnetic compatibility requirements for radio-frequency emissions, electrostatic discharges, and immunity to power- and radio-frequency fields. These checks matter because the calibrator must keep working correctly in ordinary electrical environments and must not be too susceptible to electromagnetic interference.

Clause 6 defines the minimum marking and documentation. The sound calibrator must carry identification, class, reference to this document, and the rated sound pressure level(s) and frequency(ies), while the manual must also state microphone configuration, stabilisation time, orientation if relevant, battery information, static-pressure data, EMC-related information and any non-conforming combinations of level and frequency.

Conformance testing

Annex A covers pattern evaluation tests for a model, and Annex B covers periodic tests for individual instruments. Annex A requires submitted specimens, performance tests at and around reference environmental conditions, environmental tests and EMC tests; Annex B covers submission, preliminary inspection, performance tests and a test report for periodic verification.

What terms does prEN IEC 60942:2026 define?

prEN IEC 60942:2026 defines the terms that control how outputs, test conditions and conformance are interpreted.

  • Pistonphone - a sound calibrator that generates sound pressure in a fixed air volume by piston motion.
  • Specified sound pressure level - the sound pressure level generated under reference environmental conditions for a particular microphone type and configuration.
  • Nominal sound pressure level - the rounded value used for marking, based on the specified sound pressure level.
  • Specified frequency - the frequency generated under reference environmental conditions for a particular microphone type and configuration.
  • Nominal frequency - the rounded value used for marking, based on the specified frequency.
  • Principal sound pressure level - the nominal sound pressure level identified for conformance demonstrations when more than one level is available.
  • Principal frequency - the nominal frequency identified for conformance demonstrations when more than one frequency is available.
  • Total distortion + noise - the ratio used to describe distortion and noise in the calibrator output signal.
  • Reference orientation - the orientation used for radio-frequency immunity testing, with the cavity opening facing away from the emitter or receiver.

Who uses prEN IEC 60942:2026?

prEN IEC 60942:2026 is used by sound calibrator manufacturers, test laboratories, calibration laboratories and organizations that buy or specify calibration equipment for acoustics work. It is also relevant to metrology and quality teams that need evidence of conformance for product approval, routine checks or periodic verification.

The standard is used when calibrating microphones, checking sound level meters and personal sound exposure meters, and when documenting the output of a sound calibrator against declared level and frequency settings. It is especially relevant to work involving laboratory standard microphones, transfer standard microphones and environmental or EMC testing of audio measurement equipment.

What changed in prEN IEC 60942:2026 from the previous edition?

prEN IEC 60942:2026 states that it replaces IEC 60942:2017 and that this fifth edition is a technical revision. The foreword lists these significant changes:

  • the use of a working standard microphone for demonstrating conformance has been removed;
  • conformance is now shown using either a transfer standard microphone for nominal calibrator frequencies from 31,5 Hz to 1 250 Hz, or a laboratory standard microphone for any frequency in the document;
  • the subclause on calibration of the sound calibrator with other models of microphone has been removed, so the document now covers specifications, pattern evaluation and periodic testing only;
  • electromagnetic compatibility requirements were updated to current generic standards, including an increased upper frequency limit for radiated immunity testing;
  • Annex B was changed so that all prescribed periodic tests are performed, and customers can no longer limit the tested sound pressure level and frequency settings for multi-level or multi-frequency sound calibrators.

Which standards are used with prEN IEC 60942:2026?

prEN IEC 60942:2026 relies on several normative references to define vocabulary, microphone types, measurement uncertainty and EMC testing:

  • IEC 60050-801 - vocabulary for acoustics and electroacoustics.
  • IEC 61094-1 - specifications for laboratory standard microphones.
  • IEC 61094-2:2009/AMD1:2022 - primary reciprocity calibration of laboratory standard microphones.
  • IEC 61094-9 - specifications for transfer standard microphones.
  • IEC 61672-1 - sound level meter specifications used for matching class 1 and class 2 applications.
  • IEC 61252 - personal sound exposure meters, relevant to class 2 use.
  • ISO/IEC Guide 98-3, ISO/IEC Guide 98-4 and ISO/IEC Guide 99 - measurement uncertainty and metrology terms used in conformity assessment.
  • ISO 266 - preferred frequencies used when nominal frequencies are marked or rounded.
  • IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-20, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, CISPR 16-1-1 and CISPR 16-2-3 - EMC immunity and emissions methods used in Clause 5 and Annex A.

What does the prEN IEC 60942:2026 document contain?

prEN IEC 60942:2026 contains the test logic, acceptance limits and reporting structure needed to assess sound calibrators without reproducing the detailed numerical requirements here. Table 1 classifies the instruments, Tables 2 to 7 set the acceptance limits for level, frequency, supply voltage and environmental influence, and Tables A.1 to A.5 set the maximum-permitted measurement uncertainties for the various tests.

Annex A describes the test set-up for pattern evaluation, including submission of specimens, orientation, ambient noise checks, microphone specification, environmental conditioning and EMC tests. Annex B gives the periodic-test workflow, including preliminary inspection, performance tests and the report content expected from a verification laboratory.

Annex C explains how tolerance intervals, acceptance intervals and maximum-permitted uncertainty are related in conformity assessment. Annex D gives worked examples showing how measurement results and uncertainty are used to decide conformance in practice, which is useful for laboratories, auditors and quality managers who need to interpret borderline results consistently.

Relations

Effective Date
21-Jan-2025

Buy Documents

Draft

prEN IEC 60942:2026

English language (51 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

BSMI (Bureau of Standards, Metrology and Inspection)

Taiwan's standards and inspection authority.

TAF Taiwan Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

Sponsored listings

Frequently Asked Questions

prEN IEC 60942:2026 is a draft published by CLC. Its full title is "Electroacoustics - Sound calibrators". This standard covers: Electroacoustics - Sound calibrators

Electroacoustics - Sound calibrators

prEN IEC 60942:2026 is classified under the following ICS (International Classification for Standards) categories: 17.140.50 - Electroacoustics; 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.

prEN IEC 60942:2026 has the following relationships with other standards: It is inter standard links to EN IEC 60942:2018. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

prEN IEC 60942:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-december-2026
Elektroakustika - Kalibratorji za zvokomere
Electroacoustics - Sound calibrators
Elektroakustik - Schallkalibratoren
Electroacoustique - Calibreurs acoustiques
Ta slovenski standard je istoveten z: prEN IEC 60942:2026
ICS:
17.140.50 Elektroakustika Electroacoustics
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

29/1244/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 60942 ED5
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2026-10-16 2027-01-08
SUPERSEDES DOCUMENTS:
29/1228/CD, 29/1243/CC
IEC TC 29 : ELECTROACOUSTICS
SECRETARIAT: SECRETARY:
Denmark Mrs Marika Vindbjerg
OF INTEREST TO THE FOLLOWING COMMITTEES: HORIZONTAL FUNCTION(S):

ASPECTS CONCERNED:
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of
which they are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some
Countries” clauses to be included should this proposal proceed. Recipients are reminded that the CDV stage is
the final stage for submitting ISC clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).

TITLE:
Electroacoustics - Sound calibrators

PROPOSED STABILITY DATE: 2029
NOTE FROM TC/SC OFFICERS:
download this electronic file, to make a copy and to print out the content for the sole purpose of preparing National
Committee positions. You may not copy or "mirror" the file or printed version of the document, o r any part of it,
for any other purpose without permission in writing from IEC.

Link to Committee Draft for Vote (CDV) online document:
Click here
How to access
This link leads you to the Online Standards Development (OSD) platform for National Mirror
Committee’s (NMC) comments. The project draft may be found further down this document.

Resource materials
We recommend NCs to review the available materials to better understand the member commenting
on the OSD platform. This includes the:
• OSD NC roles overview
• How to add and submit comments to the IEC

Contact
Should you require any assistance, please contact the IEC IT Helpdesk.

IEC CDV 60942 © IEC 2026
CONTENTS
CONTENTS . 3
FOREWORD . 6
Introduction. 8
1 Scope . 9
2 Normative references . 9
3 Terms and definitions . 10
4 Reference environmental conditions . 12
5 Requirements . 12
5.1 General . 12
5.2 Adaptors . 16
5.3 Sound pressure level . 16
5.3.1 General . 16
5.3.2 Time-averaged sound pressure level . 16
5.3.3 Short-term level fluctuation . 16
5.3.4 Sound pressure level over range of supply voltage . 17
5.4 Frequency . 17
5.4.1 General . 17
5.4.2 Frequency of sound generated by the sound calibrator . 17
5.5 Total distortion + noise . 18
5.6 Influence of static pressure, air temperature and relative humidity . 18
5.7 Power supply requirements . 20
5.8 Specification of microphones for testing of sound calibrators . 20
5.9 Electromagnetic compatibility . 20
5.9.1 General . 20
5.9.2 Radio-frequency emissions . 20
5.9.3 Electrostatic discharges . 21
5.9.4 Immunity to power- and radio-frequency fields . 21
6 Instrument marking and documentation . 22
6.1 Marking of the sound calibrator . 22
6.2 Individual calibration data for a class LS sound calibrator . 22
6.3 Instruction manual . 22
Annex A (normative) Pattern evaluation tests. 24
A.1 General . 24
A.2 Submission for test . 24
A.3 Principal values . 25
A.4 Marking of the sound calibrator and supplied documentation . 25
A.5 Performance tests at and around reference environmental conditions . 25
A.5.1 General . 25
A.5.2 Orientation. 25
A.5.3 Ambient noise . 25
A.5.4 Microphone specification . 26
A.5.5 Sound pressure level . 26
A.5.6 Sound pressure level stability - Short-term level fluctuation . 27
A.5.7 Frequency . 28
A.5.8 Total distortion + noise . 29
A.6 Environmental tests . 30
IEC CDV 60942 © IEC 2026
A.6.1 General . 30
A.6.2 Influence of static pressure . 30
A.6.3 Acclimatization requirements for tests of the influence of variations in
air temperature and relative humidity . 32
A.6.4 Abbreviated test of influence of air temperature and relative humidity
combined . 32
A.6.5 Influence of air temperature . 34
A.6.6 Influence of relative humidity . 36
A.6.7 Influence of air temperature and relative humidity combined . 37
A.7 Electromagnetic compatibility . 38
A.7.1 General . 38
A.7.2 Radio-frequency emissions . 38
A.7.3 Electrostatic discharges . 39
A.7.4 Immunity to power- and radio-frequency fields . 39
A.8 Test report . 41
Annex B (normative) Periodic tests . 42
B.1 General . 42
B.2 Submission for test . 42
B.3 Preliminary inspection . 42
B.4 Performance tests . 43
B.4.1 Orientation. 43
B.4.2 Ambient noise . 43
B.4.3 Environmental conditions . 43
B.4.4 Barometer . 43
B.4.5 Microphone specification . 43
B.4.6 Sound pressure level . 44
B.4.7 Frequency . 45
B.4.8 Total distortion + noise . 45
B.5 Test report . 46
Annex C (informative) Relationship between tolerance interval, corresponding
acceptance interval and the maximum-permitted uncertainty of measurement . 47
Annex D (informative) Example assessments of conformance to specifications of this
document . 48
D.1 General . 48
D.2 Conformance criteria . 48
D.3 Example test results . 48
Bibliography . 3

Figure 1 – Diagrammatic representation of sound calibrator aperture . 13
Figure C.1 – Relationship between tolerance interval, corresponding acceptance
interval and the maximum-permitted uncertainty of measurement . 47
Figure D.1 – Examples of assessment of conformance . 2

Table 1 – Sound calibrator classes and designations . 14
Table 2 – Acceptance limits for sound pressure level and short-term level fluctuation,
at and around reference environmental conditions . 17
Table 3 – Acceptance limits for the effect of supply voltage on sound pressure level,
under reference environmental conditions . 17
IEC CDV 60942 © IEC 2026
Table 4 – Acceptance limits for frequency, at and around reference environmental
conditions . 18
Table 5 – Maximum total distortion + noise . 18
Table 6 – Acceptance limits for sound pressure level, over the specified range of
environmental conditions . 19
Table 7 – Acceptance limits for frequency, over the specified range of environmental
conditions . 19
Table A.1 – Maximum-permitted uncertainty of measurement for a coverage probability
of 95 %, for sound pressure level and short-term level fluctuation at and around
reference environmental conditions. 28
Table A.2 – Maximum-permitted uncertainty of measurement for a coverage probability
of 95 % for frequency, at and around reference environmental conditions . 29
Table A.3 – Maximum-permitted uncertainty of measurement for a coverage probability
of 95 % for total distortion + noise, over the appropriate range of environmental
conditions . 30
Table A.4 – Maximum-permitted uncertainty of measurement for a coverage probability
of 95 %, for sound pressure level, over the specified range of environmental conditions . 31
Table A.5 – Maximum-permitted uncertainty of measurement for a coverage probability
of 95 % for frequency, over the specified range of environmental conditions . 34
Table D.1 – Examples of assessment of conformance . 1

IEC CDV 60942 © IEC 2026
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
Electroacoustics - Sound calibrators

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for
standardization comprising all national electrotechnical committees (IEC National Committees).
The object of IEC is to promote international co-operation on all questions concerning
standardization in the electrical and electronic fields. To this end and in addition to other
activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC
Publication(s)"). Their preparation is entrusted to technical committees; any IEC National
Committee interested in the subject dealt with may participate in this preparatory work.
International, governmental and non-governmental organizations liaising with the IEC also
participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as
possible, an international consensus of opinion on the relevant subjects since each technical
committee has representation from all interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted
by IEC National Committees in that sense. While all reasonable efforts are made to ensure that
the technical content of IEC Publications is accurate, IEC cannot be held responsible for the
way in which they are used or for any misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC
Publications transparently to the maximum extent possible in their national and regional
publications. Any divergence between any IEC Publication and the corres ponding national or
regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies
provide conformity assessment services and, in some areas, access to IEC marks of conformity.
IEC is not responsible for any services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including
individual experts and members of its technical committees and IEC National Committees for
any personal injury, property damage or other damage of any nature whatsoever, whether direct
or indirect, or for costs (including legal fees) and expenses arising out of the publication, use
of, or reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced
publications is indispensable for the correct application of this publication.
9) IEC draws attention to the possibility that the implementation of this document may involve
the use of (a) patent(s). IEC takes no position concerning the evidence, validity or applicability
of any claimed patent rights in respect thereof. As of the date of publication of this document,
IEC had not received notice of (a) patent(s), which may be required to implement this document.
However, implementers are cautioned that this may not represent the latest information, which
IEC CDV 60942 © IEC 2026
may be obtained from the patent database available at https://patents.iec.ch IEC shall not be
held responsible for identifying any or all such patent rights.
IEC 60942 has been prepared by IEC technical committee 29: Electroacoustics. It is an
International Standard.
This fifth edition cancels and replaces the fourth edition IEC 60942:2017 [1]. This edition
constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) use of a working standard microphone, as defined in IEC 61094-4:1995 [2], in demonstrating
conformance to this document is removed.
b) demonstration of conformance to this document is now via use of either a transfer standard
microphone, as defined in IEC 61094-9 , for measurements at nominal sound calibrator
frequencies from 31,5 Hz to 1 250 Hz, or use of a laboratory standard microphone, as
defined in IEC 61094-1 for measurements at any frequency given in this document,
c) removal of the subclause on calibration of the sound calibrator with other models of
microphone, such that this document deals entirely with specifications, pattern evaluation
and periodic testing of a sound calibrator. This follows the structure of other standards within
IEC/TC29.
d) updates on electromagnetic compatibility to use the current versions of the relevant generic
standards, including increasing the upper frequency limit for radiated immunity testing.
e) to ensure greater consistency and thorough periodic testing of conformance Annex B has
been changed so that all the prescribed tests are performed. For multi-level and multi-
frequency sound calibrators a limited number of sound pressure level and frequency settings
to be tested can no longer be specified by, or agreed with, the customer.
The text of this International Standard is based on the following documents:
Draft Report on voting
29/XX/FDIS 29/XX/RVD
Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English.
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/publications.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under webstore.iec.ch in the data related to the
specific document. At this date, the document will be
– reconfirmed,
– withdrawn, or
– revised.
IEC CDV 60942 © IEC 2026
Introduction
Sound calibrators are designed to produce one or more known sound pressure levels at one or
more specified frequencies when coupled to microphones of specified models in specified
configurations. The sound pressure level generated by some sound calibrators depends on the
static pressure.
Sound calibrators have two principal applications:
a) the determination of the electroacoustical pressure sensitivity of specified models of
microphone in specified configurations;
b) checking or adjusting the overall sensitivity of acoustical measuring devices or systems.
The acceptance limits for class LS sound calibrators are based on the use of a laboratory
standard microphone, as specified in IEC 61094-1, for demonstrations of conformance to the
requirements of this document. The acceptance limits for class 1 and class 2 sound calibrators
are based on the use of either a transfer standard microphone, as specified in IEC 61094 -9 or
use of a laboratory standard microphone, as specified in IEC 61094-1, for demonstrations of
conformance to the requirements of this document. Transfer standard microphones are used in
this document for the frequency range from 31,5 Hz to 1 250 Hz only.
Where a correction is required to the sound pressure level measured by the transfer standard
or laboratory standard microphone (as described in this document) the correction is provided
by the manufacturer or supplier of the acoustical measuring devices or systems.
IEC CDV 60942 © IEC 2026
1 Scope
The primary function of a sound calibrator is to generate a sinusoidal sound pressure of
specified level and frequency when coupled to specified models of microphone in specified
configurations.
This document specifies the performance requirements for three classes of sound calibrator:
class LS (Laboratory Standard), class 1 and class 2. Acceptance limits are smallest for class
LS and greatest for class 2 instruments. Class LS sound calibrators are normally used only in
the laboratory; class 1 and class 2 sound calibrators are considered as sound calibrators for
field use. A class 1 sound calibrator is primarily intended for use with a class 1 sound level
meter and a class 2 sound calibrator primarily with a class 2 sound level meter, as specified in
IEC 61672-1, and with a personal sound exposure meter, as specified in IEC 61252 [3].
To promote consistency of testing of sound calibrators and ease of use, this document contains
normative information on pattern evaluation tests and periodic tests, and informative
information on assessments of conformance to specifications of this document.
This document does not include requirements for equivalent free-field or random-incidence
sound pressure levels, such as can be used in the overall sensitivity adjustment of a sound
level meter.
A sound calibrator can provide other functions, for example, tonebursts. Requirements for these
other functions are not included in this document.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60050-801:1994, International Electrotechnical Vocabulary - Chapter 801: Acoustics and
electroacoustics
IEC 61000-4-2:2025, Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement
techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2020, Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement
techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-20:2022, Electromagnetic compatibility (EMC) - Part 4-20: Testing and
measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM)
waveguides
IEC 61000-6-1:2016, Electromagnetic compatibility (EMC) - Part 6-1: Generic standards -
Immunity for residential, commercial and light-industrial environments
IEC 61000-6-2:2016, Electromagnetic compatibility (EMC) - Part 6-2: Generic standards -
Immunity for industrial environments
IEC 61000-6-3:2020, Electromagnetic compatibility (EMC) - Part 6-3: Generic standards -
Emission standard for residential, commercial and light-industrial environment
IEC 61094-1, Measurement microphones - Part 1: Specifications for laboratory standard
microphones
IEC CDV 60942 © IEC 2026
IEC 61094-2:2009/AMD1:2022, Electroacoustics - Measurement microphones - Part 2: Primary
method for pressure calibration of laboratory standard microphones by the reciprocity technique
IEC 61672-1, Electroacoustics - Sound level meters - Part 1: Specifications
ISO/IEC Guide 98-3:2008, Uncertainty of measurement - Part 3: Guide to the expression of
uncertainty in measurement (GUM:1995)
ISO/IEC Guide 98-4:2012, Uncertainty of measurement - Role of measurement uncertainty in
conformity assessment
ISO/IEC Guide 99, International vocabulary of metrology - Basic and general concepts and
associated terms (VIM)
ISO 266:1997, Acoustics - Preferred frequencies
CISPR 16-1-1, Specification for radio disturbance and immunity measuring apparatus and
methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring
apparatus
CISPR 16-2-3:2016 + AMD1:2019 + AMD2:2023, Specification for radio disturbance and
immunity measuring apparatus and methods - Part 2-3: Methods of measurement of
disturbances and immunity - Radiated disturbance measurements
IEC 61094-9, Measurement microphones - Part 9, Specifications for transfer standard
microphones
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60050-801:1994,
ISO/IEC Guide 98-4:2012 and ISO/IEC Guide 99 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following
addresses:
– IEC Electropedia: available at https://www.electropedia.org/
– ISO Online browsing platform: available at https://www.iso.org/obp
NOTE Definitions for other relevant quantities are given in the documents referenced in Clause 2.
3.1
pistonphone
sound calibrator in which the sound pressure is generated in a fixed air volume by the motion
of one or more pistons, creating a well-defined volume velocity
3.2
specified sound pressure level
sound pressure level generated under reference environmental conditions for use with a
particular microphone type and configuration, valid for either an individual sound calibrator (in
the case of a class LS calibrator) or all sound calibrators of the same model (in the case of a
class 1 or class 2 calibrator)
Note 1 to entry: specified sound pressure level (3.2) is expressed in decibels (dB).
Note 2 to entry: The reference value is 20 µPa.
IEC CDV 60942 © IEC 2026
3.3
nominal sound pressure level
close approximation to a specified sound pressure level (3.2) , valid for all sound calibrators of
the same model, rounded to the nearest decibel (intended for marking)
Note 1 to entry: nominal sound pressure level (3.3) is expressed in decibels (dB).
Note 2 to entry: The reference value is 20 µPa.
3.4
specified frequency
frequency of the sound generated by the sound calibrator under reference environmental
conditions, valid for either an individual sound calibrator (in the case of a class LS sound
calibrator) or all sound calibrators of the same model (in the case of a class 1 or class 2 sound
calibrator)
Note 1 to entry: specified frequency (3.4) is expressed in hertz (Hz).
3.5
nominal frequency
close approximation to a specified frequency (3.4) , often rounded according to ISO 266:1997
(intended for marking)
Note 1 to entry: nominal frequency (3.5) is expressed in hertz (Hz).
3.6
principal sound pressure level
nominal sound pressure level (3.3) specified in the instruction manual as principal
Note 1 to entry: Where the sound calibrator produces more than one sound pressure level, the manufacturer
identifies one nominal sound pressure level (3.3) as principal.
Note 2 to entry: principal sound pressure level (3.6) is used during demonstration of conformance of the sound
calibrator to the requirements of this document.
Note 3 to entry: principal sound pressure level (3.6) is expressed in decibels (dB).
Note 4 to entry: The reference value is 20 µPa.
3.7
principal frequency
nominal frequency (3.5) specified in the instruction manual as principal
Note 1 to entry: Where the sound calibrator produces more than one frequency, the manufacturer identifies one
nominal frequency (3.5) as principal.
Note 2 to entry: principal frequency (3.7) is used during demonstration of conformance of the sound calibrator to
the requirements of this document.
Note 3 to entry: principal frequency (3.7) is expressed in hertz (Hz).
3.8
replications
repeat of a measurement involving coupling the microphone to the sound calibrator and then
completely removing the microphone from the sound calibrator
3.9
total distortion + noise
ratio of the root-mean-square of the total distortion and noise components, including any
harmonics and sub-harmonics, to the root-mean-square of the entire signal
Note 1 to entry: Distortion is the correlated component of the signal due to non-linearity, and noise is the
uncorrelated component.
Note 2 to entry: total distortion + noise (3.9) is expressed in per cent (%).
IEC CDV 60942 © IEC 2026
3.10
reference orientation
orientation of a sound calibrator such that the principal axis of the opening of the cavity (the
axis along which the microphone is inserted into the cavity) coincides with the principal direction
of an emitter or receiver of radio-frequency fields, the opening of the cavity facing away from
the emitter or receiver
4 Reference environmental conditions
Reference environmental conditions for specifying the performance of a sound calibrator are:
– air temperature: 23 °C;
– static pressure: 101,325 kPa;
– relative humidity: 50 %.
5 Requirements
5.1 General
5.1.1 A sound calibrator conforming to the requirements of this document shall have the
characteristics described in Clause 5.
5.1.2 A description of the aperture of the sound calibrator, the maximum and minimum
diameter of the opening, position of sealing (if any) and maximum diameter of the opening to
the cavity with the sound source (defining the support at the reference plane), as s hown in
Figure 1, shall be included in the instruction manual (see 6.3, list item b)). Dimensions shall be
in mm and given to the nearest 0,1 mm.
IEC CDV 60942 © IEC 2026
Key
1 principal axis
2 reference plane
d diameter of opening
d minimum diameter where sealing occurs
d diameter of the opening of the cavity to the sound source
h minimum possible distance from the reference plane to sealing
h maximum possible distance from the reference plane to sealing
h depth of the opening
Figure 1 – Diagrammatic representation of sound calibrator aperture
5.1.3 The sound calibrator shall conform to the requirements of this document for one or
more of the sound pressure level and frequency combinations available. A multi-level and multi-
frequency sound calibrator shall conform to the requirements for the same clas s for all sound
pressure level and frequency combinations for which the instruction manual states that the
instrument conforms to the requirements of this document (see 6.3, list item k)). The principal
sound pressure level shall be available at the principal frequency (see 6.3, list item h) and 6.3,
list item i)). Conformance to the requirements of this document shall not be stated for sound
pressure level and frequency settings for which this document provides no acceptance limits.
5.1.4 The permissible classes of sound calibrator are described in Table 1. Class LS sound
calibrators shall be supplied with individual calibration data containing the information required
by 6.2. For class 1 and class 2 sound calibrators, the specified sound pressure level (s) and
specified frequency (ies) shall be given in the instruction manual. All specified sound pressure
level (s) shall be stated in the instruction manual with a resolution better than, or equal to, 0,1
dB (see 6.3, list item c)). Each specified level shall be stated as an absolute sound pressure
level.
IEC CDV 60942 © IEC 2026
Table 1 – Sound calibrator classes and designations
Class Designation Description
LS sound calibrator designed to meet the specifications
of this document for a class LS device with no
corrections for the influence of environmental
conditions
LS
LS/M pistonphone designed to meet the specifications of
this document for a class LS device with the
application of corrections for the influence of static
pressure only
1 sound calibrator designed to meet the specifications
of this document for a class 1 device with no
corrections for the influence of environmental
conditions
1/M pistonphone designed to meet the specifications of
this document for a class 1 device with the
application of corrections for the influence of static
pressure only
2 2 sound calibrator designed to meet the specifications
of this document for a class 2 device with no
corrections for the influence of environmental
conditions
5.1.5 Class LS and class 1 pistonphones that require corrections for the influence of static
pressure in order to conform to the requirements of this document for the appropriate class
shall be designated LS/M or 1/M, as appropriate.
For sound calibrators designated LS/M and 1/M, the corrections for static pressure, necessary
for the sound calibrator to conform to the requirements of this document, shall be stated in the
instruction manual, together with the uncertainties of measurement corresponding to a
coverage probability of 95 % (see 6.3, list item j)). Sound calibrators designated LS/M and 1/M
shall not require corrections for any of the other environmental conditions to achieve the
requirements specified for the appropriate class.
5.1.6 Sound calibrators designated LS/M may also claim conformance to the requirements
for a sound calibrator designated 1/M if the full specifications described in this document are
met for both classes of sound calibrator.
5.1.7 Sound calibrators, other than those with a class designation LS/M or 1/M, shall not
require corrections for any environmental conditions in order to conform to the requirements for
the relevant class.
5.1.8 Sound calibrators designated LS/M or 1/M shall either be supplied with a barometer,
or the manufacturer shall state the specifications in the instruction manual for any barometer to
be used (see 6.3, list item o)). A statement shall be included in the instruction manual giving
the uncertainty of the measurement of static pressure required, for a coverage probability of
95%, so that the ability of a sound calibrator designated LS/M or 1/M to conform to the
requirements for the relevant class is not affected (see 6.3, list item n)).
NOTE 1 A sound calibrator designated LS/M is normally used only in the laboratory where a suitable device is likely
to be available for measuring static pressure.
NOTE 2 Some barometers provide the data directly in the form to be used to correct measured sound pressure
levels to the reference static pressure.
5.1.9 If a specific orientation of the sound calibrator is to be used to conform to the
requirements of this document, this orientation shall either be indicated on the sound calibrator,
or the indication on the sound calibrator shall refer to the instruction ma nual (see 6.3, list item
e)), which shall state the required orientation.
IEC CDV 60942 © IEC 2026
5.1.10 All performance requirements relate to the operation of the sound calibrator following
stabilizing of the coupling of the microphone and sound calibrator, and after the sound pressure
level and frequency have stabilized. The elapsed time necessary for stab ilization of the sound
pressure level and frequency, which begins once the sound calibrator is switched on with the
microphone coupled to it, shall be stated in the instruction manual, and shall not exceed 30 s
for any applicable combination of environmental conditions specified in 5.6. Where this
stabilization time exceeds 10 s, an indicator shall be provided to demonstrate when the output
from the sound calibrator has stabilised. Information on the operation of this indicator shall be
given in the instruction manual (see 6.3, list item f)).
5.1.11 Following the stabilization time, the sound pressure level and frequency shall remain
stable within the acceptance limits of Table 2 and Table 4, or Table 6 and Table 7, as applicable,
whilst switched on, which shall be for a period of at least 70 s. The sound calibrator and
microphone shall be allowed to reach equilibrium with the prevailing environmental conditions
before coupling. The sound calibrator shall be designed so that the static pressure inside the
sound calibrator is equal to the static pressure to which the pressure equalization system of the
microphone is exposed.
NOTE 1 A period of at least 70 s is chosen as the measurement of short-term level fluctuation described in 5.3.3
requires measurement over a period of 60 s of operation of the sound calibrator.
NOTE 2 The stabilization time required following the coupling of the microphone to the sound calibrator can vary
considerably depending on the microphone and sound calibrator in use.
NOTE 3 For the case of back-vented microphones the equality of static pressure is normally achieved by designing
the sound calibrator so that the static pressure inside the sound calibrator is equal to the static pressure outside the
sound calibrator.
NOTE 4 If the microphone is front-vented and the static pressure inside the sound calibrator is known, the static
pressure inside and outside the sound calibrator do not need to be equal.
5.1.12 If the tests described in Annex A require the sound calibrator to operate for longer than
the normal operating time, the manufacturer shall provide information in the instruction manual
to describe how this can be achieved (see 6.3, list item g)).
5.1.13 Those components of a sound calibrator that are not intended to be accessible to the
user shall be protected by markings or a mechanism that makes those components
inaccessible.
5.1.14 In 5.3 to 5.9, acceptance limits are provided for allowable values of measured
deviations from design goals. For testing laboratories, the maximum-permitted uncertainties of
measurement for a coverage probability of 95 % are stated in Annex A. Annex C describes the
relationship between tolerance interval, corresponding acceptance interval and the maximum -
permitted uncertainty of measurement.
5.1.15 The acceptance limits given for class LS sound calibrators also apply to sound
calibrators designated LS/M. The acceptance limits given for class 1 sound calibrators also
apply to sound calibrators designated 1/M.
5.1.16 Conformance to a performance specification is demonstrated when the following
criteria are both satisfied: (a) measured deviations from design goals do not exceed the
applicable acceptance limit and (b) the corresponding uncertainty of measurement does not
exceed the corresponding maximum-permitted uncertainty of measurement given in Annex A
for a coverage probability of 95 %.
5.1.17 If the actual uncertainty of a measurement performed by the test laboratory, calculated
for a coverage probability of 95 %, exceeds the maximum-permitted value given in Annex A,
the measurement shall not be used to demonstrate conformance to the requirements of this
document.
5.1.18 Annex D gives examples of evaluation of conformance to specifications of this
document.
IEC CDV 60942 © IEC 2026
5.1.19 Full conformance to this document is only demonstrated when the model of sound
calibrator has been shown to conform to the requirements of this document for pattern
evaluation when tested according to Annex A, and the individual specimen of sound calibrator
has been shown to conform to the requirements of this document for periodic testing when
tested according to Annex B.
5.2 Adaptors
Adaptors may be provided to accommodate transfer standard or laboratory standard
microphones. For the purpose of this document, any such adaptor is an integral part of the
sound calibrator. The instruction manual for the sound calibrator may provide inform ation to
allow design of any adaptors to be used with the sound calibrator. This design data shall include
all the information necessary to create an adaptor that can be used with the specified sound
calibrator in a manner that maintains the specified performance class. Where this design data
are supplied, the instruction manual shall specify the insertion distance and minimum diameter
of the microphone at which sealing will occur (see 6.3, list item v)).
5.3 Sound pressure level
5.3.1 General
5.3.1.1 All the requirements and acceptance limits specified in 5.3 relate to the level of the
sound pressure produced at the diaphragm of the inserted microphone.
5.3.1.2 The principal sound pressure level (see 6.3,
...