Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 2: Sealants for glazing

This European Standard specifies definitions and requirements for non-structural elastic sealants used for sealing glazing in building construction applications.
It covers glazing joints from 7° horizontal. Main areas of application are:
-   glass to glass;
-   glass to frame;
-   glass to porous substrates.
Excluding aquariums, structural bonding/glazing, inner and outer seal to manufacture insulated glazing units, horizontal glazing (below 7°), organic glass (e.g. polycarbonate, PMMA, etc.).

Fugendichtstoffe für nicht tragende Anwendungen in Gebäuden und Fußgängerwegen - Teil 2: Fugendichtstoffe für Verglasungen

Diese Europäische Norm legt Definitionen für und Anforderungen an nicht tragende, elastische Fugen-dichtstoffe für die Abdichtung von Verglasungen im Hochbau fest.
Diese Europäische Norm erfasst Verglasungsfugen ab einem Winkel von 7° zur Horizontalen. Die Haupt-bereiche, in denen diese Fugendichtstoffe eingesetzt werden, sind:
-   Glas an Glas;
-   Glas an Rahmen;
-   Glas an porösen Trägermaterialien.
Anwendungen für Aquarien, tragende Verbindungen/Verglasungen, innere und äußere Abdichtungen von vor-gefertigten Isolierglaseinheiten, horizontale Verglasungen (mit einer Neigung von weniger als 7°) und Vergla-sungen aus organischem Material (z. B. Polycarbonat, PMMA usw.) fallen nicht in den Anwendungsbereich dieser Europäischen Norm.

Mastics pour joints pour des usages non structuraux dans les constructions immobilières et pour chemins piétonniers - Partie 2: Mastics pour vitrage

La présente Norme européenne spécifie des définitions et des exigences relatives aux mastics élastiques utilisés en vitrage dans la construction immobilière.
Elle traite des joints pour vitrages au delà de 7°par rapport à l’horizontal. Les principaux domaines d’application sont :
-   verre sur verre ;
-   verre sur châssis ;
-   verre sur supports poreux.
Sont exclus les aquariums, les vitrages extérieurs collés, les mastics intérieurs et extérieurs pour les vitrages isolants, les vitrages horizontaux (jusqu’à 7°), le verre organique (par exemple, polycarbonate, PMMA, etc.).

Tesnilne mase za nekonstrukcijske stike v stavbah in na sprehajalnih površinah - 2. del: Tesnilne mase za zasteklitev

Ta evropski standard določa definicije in zahteve za nekonstrukcijske elastične tesnilne mase, ki se uporabljajo za zasteklitev pri gradnji stavb. Zajema stike zasteklitve od 7° vodoravno. Glavna področja uporabe so:
– steklo na steklo;
– steklo na ogrodje;
– steklo na porozno podlago.
Ne vključuje akvarijev, strukturnega spajanja/zasteklitve, notranjega in zunanjega tesnjenja za izdelovanje izoliranih zastekljenih enot, vodoravne zasteklitve (pod 7°), organskega stekla (npr. polikarbonat, PMMA itd.).

General Information

Status
Withdrawn
Publication Date
11-Sep-2012
Withdrawal Date
20-Jan-2026
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
15-Feb-2017
Completion Date
28-Jan-2026

Relations

Effective Date
12-Mar-2011
Effective Date
22-Feb-2017
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026

Get Certified

Connect with accredited certification bodies for this standard

ICC Evaluation Service

Nonprofit organization that performs technical evaluations of building products.

ANAB United States Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

BBA (British Board of Agrément)

UK construction product certification.

UKAS United Kingdom Verified

Sponsored listings

Frequently Asked Questions

EN 15651-2:2012 is a standard published by the European Committee for Standardization (CEN). Its full title is "Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 2: Sealants for glazing". This standard covers: This European Standard specifies definitions and requirements for non-structural elastic sealants used for sealing glazing in building construction applications. It covers glazing joints from 7° horizontal. Main areas of application are: - glass to glass; - glass to frame; - glass to porous substrates. Excluding aquariums, structural bonding/glazing, inner and outer seal to manufacture insulated glazing units, horizontal glazing (below 7°), organic glass (e.g. polycarbonate, PMMA, etc.).

This European Standard specifies definitions and requirements for non-structural elastic sealants used for sealing glazing in building construction applications. It covers glazing joints from 7° horizontal. Main areas of application are: - glass to glass; - glass to frame; - glass to porous substrates. Excluding aquariums, structural bonding/glazing, inner and outer seal to manufacture insulated glazing units, horizontal glazing (below 7°), organic glass (e.g. polycarbonate, PMMA, etc.).

EN 15651-2:2012 is classified under the following ICS (International Classification for Standards) categories: 91.100.50 - Binders. Sealing materials. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 15651-2:2012 has the following relationships with other standards: It is inter standard links to EN 15651-2:2010, EN 15651-2:2017, EN ISO 9047:2003, EN ISO 10590:2005, EN ISO 10591:2021, EN ISO 10563:2023, EN ISO 1183-1:2004, EN ISO 11431:2025, EN ISO 9046:2021, EN ISO 7389:2003, EN ISO 11600:2003, EN ISO 11432:2021, EN ISO 868:2003, EN 15651-5:2012, EN ISO 8339:2005. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 15651-2:2012 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC; Standardization Mandates: M/474. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 15651-2:2012 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Tesnilne mase za nekonstrukcijske stike v stavbah in na sprehajalnih površinah - 2. del: Tesnilne mase za zasteklitevFugendichtstoffe für nicht tragende Anwendungen in Gebäuden und Fußgängerwegen - Teil 2: Fugendichtstoffe für VerglasungenMastics pour joints pour des usages non structuraux dans les constructions immobilières et pour chemins piétonniers - Partie 2: Mastics pour vitrageSealants for non-structural use in joints in buildings and pedestrian walkways - Part 2: Sealants for glazing91.100.50Veziva. Tesnilni materialiBinders. Sealing materialsICS:Ta slovenski standard je istoveten z:EN 15651-2:2012SIST EN 15651-2:2013en,fr,de01-april-2013SIST EN 15651-2:2013SLOVENSKI
STANDARDSIST EN 15651-2:20101DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 15651-2
September 2012 ICS 91.100.50 Supersedes EN 15651-2:2010English Version
Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 2: Sealants for glazing
Mastics pour joints pour des usages non structuraux dans les constructions immobilières et pour chemins piétonniers - Partie 2: Mastics pour vitrage
Fugendichtstoffe für nicht tragende Anwendungen in Gebäuden und Fußgängerwegen - Teil 2: Fugendichtstoffe für Verglasungen This European Standard was approved by CEN on 10 August 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15651-2:2012: ESIST EN 15651-2:2013

Example on the frequency of tests for factory production control . 13Annex ZA (informative)
Clauses of this European Standard addressing the provisions of EU Construction Products Directive . 14ZA.1Scope and relevant characteristics . 14ZA.2Procedure for attestation of conformity of non-structural elastic sealants used for sealing glazing . 16ZA.2.1Systems of attestation of conformity . 16ZA.2.2EC certificate of conformity and EC declaration of conformity . 18ZA.3CE marking and labelling . 19ZA.3.1 General . 19ZA.3.2 CE marking on the packaging . 20ZA.3.3 CE marking in the accompanying commercial documents . 20Bibliography . 23 SIST EN 15651-2:2013

(ISO 10563) EN ISO 10590, Building construction — Sealants — Determination of tensile properties of sealants at maintained extension after immersion in water (ISO 10590) EN ISO 10591, Building construction — Sealants — Determination of adhesion/cohesion properties of sealants after immersion in water (ISO 10591) EN ISO 11358, Plastics — Thermogravimetry (TG) of polymers — General principles (ISO 11358) EN ISO 11431, Building construction — Jointing products — Determination of adhesion/cohesion properties of sealants after exposure to heat, water and artificial light through glass (ISO 11431) EN ISO 11432, Building construction — Sealants — Determination of resistance to compression (ISO 11432) EN ISO 11600, Building construction — Jointing products — Classification and requirements for sealants (ISO 11600) EN ISO 11925-2, Reaction to fire tests — Ignitability of products subjected to direct impingement of flame — Part 2: Single-flame source test (ISO 11925-2) ISO 13640, Building construction — Jointing products — Specifications for test substrates 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN ISO 6927:2012 and the following apply. 3.1 non-reactive sealant mainly physical drying mechanism, without significant change in the molecular weight of the main polymer 3.2 reactive sealant mainly curing by chemical reaction, with significant increase of the molecular weight of the main polymer 3.3 cure irreversible transformation of a sealant from a liquid or paste-like state into a hardened or rubber-like solid state 3.4 uncured/wet state of a sealant prior to the above transformation 4 Requirements 4.1 Identification requirements and test methods 4.1.1 Short description of the sealant The short description of the non-structural sealant for glazing elements shall include: brand name, type (general chemical family), opaque or translucent, waterborne or solvent based or solvent free, reactive or non-reactive, and one or multi-component (e.g. neutral cure, reactive silicone and one component, etc.). SIST EN 15651-2:2013

At least three samples shall be tested and the five measurements taken per sample. The mean value and tolerances of all measurements, recorded to the nearest unit, shall be declared. 4.2 Conditioning, test procedure and substrates When determining the classification of a glazing sealant according to the requirements of this standard, the same conditioning procedure shall be used in all relevant test methods (use only Method A or Method B). For each test method, three test specimens for each substrate shall be tested. The same batch of sealant (and primer, if used) shall be used in all tests. The same substrates (material and surface finish) shall be used in all tests. Tests shall be performed on glass according to ISO 13640.
The specific test conditions for each test method are given in Table 1. SIST EN 15651-2:2013

Test methodClasses for non structural sealants for glazing elements 25LM25HM20LM20HM Elongationa EN ISO 7389 EN ISO 8339 EN ISO 8340 EN ISO 10590 EN ISO 11431100 % 100 % 60 % 60 % Amplitude EN ISO 9047 ± 25 % ± 25 % ± 20 % ± 20 % a
The value of elongation is given as a percentage of the original width: elongation % = [(final width – original width) / (original width)] x 100 %.
Substrates to be used in all mechanical tests concerned shall be glass according to ISO 13640. Additional substrates to be considered mortar M1 or M2 and/or anodised aluminium.
4.3 Performance requirements 4.3.1 General Classes for elastic sealants for glazing in building construction are referred to as type G. A summary of the characteristics and classes are given in Table 2. SIST EN 15651-2:2013

Elastic Recovery (%) ≥ 60
≥ 60 ≥ 60 ≥ 60 EN ISO 7389 Resistance to flow (mm) ≤ 3 ≤ 3 ≤ 3 ≤ 3 4.3.3 Tensile properties Secant modulus (MPa) ≤ 0,4 (23 °C) and ≤ 0,6 (- 20 °C) > 0,4 (23 °C) or > 0,6 (- 20 °C) ≤ 0,4 (23 °C) and ≤ 0,6 (- 20 °C) > 0,4 (23 °C) or > 0,6 (- 20 °C) EN ISO 8339 Adhesion/cohesion at maintained extension
NF NF NF
NF EN ISO 8340 Adhesion/cohesion at variable temperatures NF NF
NF
NF EN ISO 9047 Adhesion/cohesion at maintained extension after water immersion NF NF
NF
NF EN ISO 10590 Loss of volume (%)
≤ 10 ≤ 10 ≤ 10 ≤ 10 EN ISO 10563 Adhesion/cohesion properties after exposure to heat, water and artificial light NF NF NF NF EN ISO 11431 Resistance to compression Record value Record value Record value Record value EN ISO 11432 NF = No Failure according to EN ISO 11600.
4.3.2 Sealants for glazing elements in cold climates 4.3.2.1 General This test has been developed to demonstrate that glazing sealants perform well at lower temperatures than those currently tested in EN ISO 11600 (i.e. common winter temperatures in Northern Europe). The specification intention is to ensure that the sealant continues to perform at - 30 °C, which is a common winter temperature in cold climate areas.
In addition to the requirements given in Table 2, non-structural sealants for glazing elements required to maintain performance in cold climate (- 30 °C) shall fulfil also requirements as given in Table 3.
The classification of the sealant given in Table 2 shall be determined prior to this optional additional test and the corresponding test amplitude shall be applied to this additional test.
The designation CC (cold climate) shall be declared for any sealant meeting the requirements of Table 2. For example, Type G Class 25LM CC. SIST EN 15651-2:2013

2) °C for at least 4 h before the start of the test. The spacers for the preparation of the test specimens shall be removed and the test specimen placed in the tensile test machine and extended at (- 30 ±
2) °C at a rate of (5,5 ±
0,7) mm/min until rupture occurs. The force/extension diagram shall be recorded. 4.3.2.3 Tensile properties at maintained extension to EN ISO 8340 - test procedure at (- 30 ± 2) °C The test specimens shall be stored at (− 30 ±
2) °C for at least 4 h before the start of the test. The spacers for the preparation of the test specimens shall be removed and the test specimens placed in the tensile test machine at (- 30 ±
2) °C and extended at a rate of (5,5 ±
0,7) mm/min by 60 % or 100 % of the original width (to 19,2 mm and 24 mm respectively). The separators shall be used to maintain the elongation at (- 30 ±
2) °C for 24 h. The test specimens shall be brought to (23 ±
2) °C. The depth of any loss of adhesion or cohesion shall be measured using a suitable measuring device capable of reading to 0,5 mm. Table 3 — Requirements to be suitable for use in cold climate areas Properties Class of glazing sealants in cold climates Test method 25 LM 25 HM 20 LM 20 HM Tensile properties Secant Modulus (MPa) ≤ 0,9 MPa Not required ≤ 0,9 MPa Not required 4.3.2.2 Adhesion/Cohesion
at maintained extension NF NF NF NF 4.3.2.3 NF = No failure according to EN ISO 11600.
4.3.3 Resistance to flow The resistance to flow shall be measured according to EN ISO 7390, with the precise test method modified according to the following details. A vertical, anodised aluminium U-profile shall be used with dimensions 20 mm x 10 mm. Testing shall be carried out under two temperature conditions: a) temperature of (50 ± 2) °C and relative humidity of (50 ± 10) %; b) temperature of (5 ± 2) °C. If the flow exceeds the required value, then the test may be repeated once. 4.3.4 Resistance to water and UV Evaluation according to EN ISO 11431 using only fully automated equipment. The specific conditions of the test following EN ISO 11431 will require fully automated equipment with immersion of the test specimen in demineralised water. The UV lamp will be switched off during the water immersion.
4.3.5 Resistance to compression Evaluation according to EN ISO 11432. SIST EN 15651-2:2013
...