EN 1192:1999
(Main)Doors - Classification of strength requirements
Doors - Classification of strength requirements
This Standard provides a means of classifying where appropriate, the performance of door leaves, door frames, doorsets, and door assemblies according to their strength in resisting vertical load, static torsion, soft and heavy body impact,and hard body impact. The performance level indicate normal usage for a range of categories of duty. Special requirements such as those for burglar resistance or safety requirements related to glass infillings are not covered.
Türen - Klassifizierung der Festigkeitsanforderungen
Diese Norm dient zur Klassifizierung der Festigkeit von Türblätten, Türzargen und Türelementen bei vertikaler Belastung, statischer Verwindung, weichem und schwerem sowie hartem Stoß Widerstand zu leisten. Die Leistungsstufen berücksichtigen den üblichen Gebrauch für eine Reihe von Nutzungskategorien. Spezielle Anforderungen wie die der Einbruchsicherheit oder Sicherheitsanforderungen bezogen auf Glasfüllungen sind nicht abgedeckt.
Portes - Classification des exigences de résistance mécanique
La présente norme procure un moyen de classement des performances des vantaux, huisseries, blocs portes, blocs-portes assemblés selon leurs résistance à la charge verticale, à la torsion statique, au choc de corps mou et lourd, au choc de corps dur. Les niveaux de performance indiquent l'usage normal pour une gamme de types de sollicitations. Ne sont pas incluses les exigences spéciales, telles que celles concernant la résistance à l'effraction ou celles de sécurité liées aux remplissages en verre.
Vrata - Klasifikacija po zahtevah za trdnost
General Information
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Vrata - Klasifikacija po zahtevah za trdnostTüren - Klassifizierung der FestigkeitsanforderungenPortes - Classification des exigences de résistance mécaniqueDoors - Classification of streng
...
This May Also Interest You
This document specifies requirements regarding design and test methods for power operated pedestrian doorsets. Examples of how the doorset constructions may be operated include: electro-mechanically, electro-hydraulically, electro-magnetically or pneumatically.
This document covers safety in use of power operated pedestrian doorsets used for normal access as well as in emergency and escape routes and as fire resistance and/or smoke control doorsets.
The type of doorsets covered include power operated pedestrian sliding, swing and revolving doorsets, including balanced doorsets and folding doorsets with a horizontally moving door leaf.
This document deals with all significant hazards, hazardous situations and events relevant to power operated doorsets when they are used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer.
All lifetime phases of the power operated pedestrian doorsets including transportation, assembly, dismantling, disabling and scrapping are considered by this document.
This document does not apply to:
- vertically moving doors;
- doors on lifts;
- doors on vehicles;
- power operated doors or gates mainly intended for vehicular traffic or access for goods;
- doors used in industrial processes;
- partition walls;
- doors outside the reach of people (such as crane gantry fences);
- turnstiles;
- platform doors;
- traffic barriers.
This document does not cover special functions of doorsets, such as security in banks, airports, etc. or fire and/or smoke compartmentation, where conformity of the specific function with requirements of the application is the preference.
This document does not deal with any specific requirements on noise emitted from power operated pedestrian doorsets as their noise emission is not considered to be a relevant hazard.
NOTE Noise emission of power operated pedestrian doorsets is not a significant hazard for the users of these products. It is a comfort aspect.
This document is not applicable to power operated pedestrian doorsets manufactured before the date of its publication.
This document does not cover operation in environments where there is a risk of explosion.
- Standard67 pagesEnglish languagesale 10% offe-Library read for×1 day
- 26-Mar-2024
- 91.060.50
- 2006/42/EC
- M/396
- CEN/TC 33
This document specifies the test method, safety requirements and classification when determining the effect on a complete window or pedestrian doorset impacted with a soft and heavy body. Any secondary moving sashes, casements, leaves, mullions, transoms, T-connectors or fixed lights which can be mounted internally to the main casements or sashes, are intended to also be similarly tested and evaluated for the classification for the complete product.
The test applies to all types of infill of whatever materials including glass. It is not intended to classify the strength of the glass when used as an infill. It is intended to assess the interactions between all components of a window with particular regard to safety in use. It is also applicable to assess the ability of a doorset to keep in place glazed parts.
NOTE 1 The test method is aimed for glazed pedestrian doorsets with injury risk, but can also be used for other types of pedestrian doorsets if requested by the client.
NOTE 2 The test has been devised to suit all window or pedestrian doorset types, configurations and materials.
NOTE 3 For the classification of glass see EN 12600.
- Standard8 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies requirements for assessment of the mechanical strength of metal profiles incorporating a thermal barrier having mechanical performance depending on their intended use.
It also specifies the tests to determine the characteristic values of mechanical properties of the thermal barrier profile and to assess the effect of different conditionings of the thermal barrier on the mechanical performance of the connection.
This document does not apply to thermal barriers which do not give a contribution to the mechanical resistance of the profiles.
This document is applicable to thermal barrier profiles designed mainly for windows, doors, screens and curtain walls.
This document does not apply to thermal barriers made only of metal profiles connected with metal pins or screws.
This current edition of EN 14024 will supersede EN 14024:2004. Differences in test procedures between the two versions will not lead to significant differences in test results. Therefore, existing test results according to EN 14024:2004 are considered as equivalent to new test results according to the current edition of EN 14024.
- Standard63 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies requirements and test methods for the safety in use of power operated door, gate and barrier, intended for installation in areas in the reach of persons, and for which the main intended use is giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises.
This European Standard also covers power operated vertically moving commercial doors such as rolling shutters and rolling grilles, used in retail premises which are mainly provided for goods protection.
This European Standard deals with all significant hazards, hazardous situations and events relevant to the power operation of industrial, commercial and garage doors, and gates when they are used as intended and under conditions of misuse which are reasonably foreseeable as identified in Clause 4.
All lifetime phases of the machinery including transportation, assembly, dismantling, disabling and scrapping are considered by this standard.
This European Standard does not apply to
- lock gates and dock gates;
- doors on lifts;
- doors on vehicles;
- armoured doors;
- doors mainly for the retention of animals, unless they are at the site perimeter ;
- theatre textile curtains;
- horizontally moving power operated doors mainly intended for pedestrian use;
- doors outside the reach of people (such as crane gantry fences);
- railway barriers;
- barriers intended solely for use by pedestrians;
- barriers used solely for vehicles on motorways.
Whenever the term "door" is used in this document, it shall be deemed to cover the full scope of types and variances of doors, gates and barriers in the scope of this Standard.
This European Standard does not deal with any specific requirements on noise emitted from power operated door, gate and barrier, intended for installation in areas in the reach of persons, and for which the main intended use is giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises as their noise emission is not considered to be a relevant hazard.
NOTE Noise emission of power operated doors is not a significant hazard for the users of these products. It is a comfort aspect.
This European Standard is not applicable to machinery which are manufactured before the date of publication of the standard.
- Standard68 pagesEnglish languagesale 10% offe-Library read for×1 day
- 21-Dec-2021
- 29-Jun-2022
- 91.060.50
- 2006/42/EC
- M/396
- CEN/TC 33
This document gives the tolerance limits for specified dimensions of height, width and thickness, and for squareness of door leaves. It applies to door leaves which are supplied without, and independent of, any frames. It does not apply to the leaves of doorsets.
NOTE Compliance with the tolerance limits given in this document does not imply that this would necessarily produce a perfect fit between door leaves and frames
- Standard4 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a test method for the determination of resistance to manual burglary attempts in order to assess the burglar resistant characteristics of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following opening functions: turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically), pivoted (horizontally and vertically), projecting, and rolling as well as non-openable constructions.
This document does not directly cover the resistance of locks and cylinders to attack with picking tools. It also does not cover the attack of electric, electronic and electromagnetic operated burglar resistant construction products using surreptitious attack methods that might defeat these characteristics.
It is acknowledged that there are two aspects to the burglar resistance performance of construction products, their normal resistance to forced operation and their ability to remain fixed to the building. This test method does not evaluate the performance of the fixing to the building.
The manufacturer's installation instructions will give guidance on the fixing of the product.
An example for the contents of the manufacturer’s installation instructions is given in EN 1627:2021, Annex A.
This document does not apply to walls and roofs, as well as for doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241:2003+A2:2016.
NOTE It is important that construction products that can be reached or driven through by vehicles are protected by appropriate measures such as barriers, extensible ramps, etc.
- Standard47 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a test method for the determination of resistance to static loading in order to assess the burglar resistant properties of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following opening functions: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically), pivoted (horizontally and vertically), projecting, and rolling as well as non-openable constructions.
It is acknowledged that there are two aspects to the burglar resistance performance of construction products, their normal resistance to forced operation and their ability to remain fixed to the building. This test method does not evaluate the performance of the fixing to the building.
The manufacturer's installation instructions will give guidance on the fixing of the product.
An example for the contents of the manufacturer’s installation instructions is given in EN 1627:2021, Annex A.
This document does not apply to walls and roofs, as well as for doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241:2003+A2:2016.
NOTE It is important that construction products that can be reached or driven through by vehicles are protected by appropriate measures such as barriers, extensible ramps, etc.
- Standard88 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a test method for the determination of resistance to dynamic loading in order to assess the burglar resistant properties of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following opening functions: turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically), projecting, pivoted (horizontally and vertically) and rolling as well as non-openable constructions.
It is acknowledged that there are two aspects to the burglar resistance performance of construction products, their normal resistance to forced operation and their ability to remain fixed to the building. This test method does not evaluate the performance of the fixing to the building.
The manufacturer's installation instructions will give guidance on the fixing of the product.
An example for the contents of the manufacturer's installation instructions is given in EN 1627:2021, Annex A.
This document does not apply to walls and roofs, as well as for doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241:2003+A2:2016.
NOTE It is important that construction products that can be reached or driven through by vehicles are protected by appropriate measures such as barriers, extensible ramps, etc.
- Standard41 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies requirements and classification systems for burglar resistant characteristics of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following opening functions: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically), pivoted (horizontally and vertically), projecting and rolling as well as non-openable constructions. It also covers products that include items such as letter plates or ventilation grilles. It specifies requirements for the burglar resistance of a construction product (as defined in 3.1 of this document).
NOTE 1 The elements of curtain walling will be assigned to group 1 to 4 product depending on their design.
This document does not directly cover the resistance of locks and cylinders to attack with picking tools. Building hardware are components of the above mentioned products and cannot be classified as such according to this document.
This document does not apply to walls and roofs, as well as for doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241:2003+A2:2016.
NOTE 2 It is important that construction products that can be reached or driven through by vehicles are protected by appropriate measures such as barriers, extensible ramps, etc.
The requirements to an electronic security system (e.g. access control system) to control electromechanical locks and strikes according to EN 14846:2008 are not in the scope of this document.
NOTE 3 Locks and striking plates according to EN 14846:2008 needs an access control system for authorized and secure access (comparable to a lock cylinder). The transmission of the signal between the lock and the access control system (e.g. wiring) needs also consideration. (The signal is transmitted in encrypted form or is not accessible during the manual attack attempt.) Upcoming revisions of this document might include such a reference.
- Standard36 pagesEnglish languagesale 10% offe-Library read for×1 day
This document is applicable to power-operated pedestrian swing door drives with self closing function using mechanically stored energy for single and double leaf swing doorsets with or without fire resistance and smoke control characteristics. It defines requirements and test methods for the self-closing function.
This document does not apply to:
- electrically controlled hold-open systems according to EN 14637;
- door coordinating devices according to EN 1158;
- electrically powered hold-open devices for swing doors according to EN 1155.
Requirements and test methods for hold-open systems are not part of this document.
Additional requirements and test methods for the use of power-operated pedestrian swing door drives with self closing function on double-leaf swing doors are described in EN 1158 and are therefore not part of this document.
- Standard20 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.