prEN 17020-4
(Main)Extended application of test results on durability of self-closing for fire resistance and/or smoke control doorsets and openable windows - Part 4: Durability of self-closing of fire resistance hinged and pivoted metal framed glazed doorsets and openable windows
Extended application of test results on durability of self-closing for fire resistance and/or smoke control doorsets and openable windows - Part 4: Durability of self-closing of fire resistance hinged and pivoted metal framed glazed doorsets and openable windows
This Europan Standard covers single and double leaf, hinged and pivoted metal framed, glazed doorsets or openable windows as covered by EN 15269 5.
This document prescribes the methodology for extending the application of test results obtained from durability self-closing test(s) conducted in accordance with EN 1634 1.
Subject to the completion of the appropriate self-closing test or tests the extended application may cover all or some of the following non-exhaustive list:
- Integrity only (E), radiation (EW) or insulated (EI1 or EI2) classifications;
- doorsets and openable windows
- door / window leaf;
- wall/ceiling fixed elements (frame/suspension system);
- glazing and non-glazed panels in doorset and openable window;
- items of building hardware;
- decorative finishes;
- intumescent, smoke, draught or acoustic seals;
- alternative supporting construction(s).
Application étendue des résultats d’essais de durabilité de la fermeture automatique des blocs-portes et fenêtres ouvrantes - Partie 4 : Durabilité de la fermeture automatique des blocs-portes vitrés battants et pivotants à ossature métallique et des fenêtres ouvrantes à ossature métallique résistants au feu
La présente Norme européenne couvre les blocs-portes vitrés battants et pivotants à ossature métallique et les fenêtres ouvrantes à ossature métallique, à un ou deux vantaux, visés par l’EN 15269 5.
Ce document établit la méthodologie d’extension de l’application des résultats d’essai obtenus suite aux essais de durabilité de la fermeture automatique réalisés conformément à l’EN 1634-1.
Sous réserve de la réalisation de l’essai ou des essais appropriés de fermeture automatique, l’application étendue peut couvrir tout ou partie des éléments de la liste non exhaustive suivante :
- classements d’étanchéité au feu uniquement (E), aux rayonnements (EW) ou à l’isolation thermique (EI1 ou EI2) ;
- blocs-portes et fenêtres ouvrantes ;
- vantail de bloc-porte/fenêtre ;
- éléments fixes muraux/de plafond (structure/système de suspension) ;
- vitrages et panneaux non vitrés d’un bloc-porte ou d’une fenêtre ouvrante ;
- tout élément de quincaillerie de bâtiment ;
- finitions décoratives ;
- joints intumescents, joints d’étanchéité aux fumées, joints d’étanchéité à l’air ou joints acoustiques ;
- autre(s) support(s).
Razširjena uporaba rezultatov preskusov trajnosti samozapiranja za vrata in okna, ki se odpirajo - 4. del: Trajnost samozapiranja požarno odpornih vrat z vrtljivim krilom, zastekljenih v kovinskih okvirjih, in oken, ki se odpirajo
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2016
Razširjena uporaba rezultatov preskusov trajnosti samozapiranja za vrata in okna,
ki se odpirajo - 4. del: Trajnost samozapiranja požarno odpornih vrat z vrtljivim
krilom, zastekljenih v kovinskih okvirjih, in oken, ki se odpirajo
Extended application of test results on durability of self-closing for doorsets and
openable windows - Part 4: Durability of self-closing of fire resistance hinged and pivoted
metal framed glazed doorsets and openable windows
Application étendue des résultats d’essais de durabilité de la fermeture automatique des
blocs-portes et fenêtres ouvrantes - Partie 4 : Durabilité de la fermeture automatique des
blocs-portes vitrés battants et pivotants à ossature métallique et des fenêtres ouvrantes
à ossature métallique résistants au feu
Ta slovenski standard je istoveten z: prEN 17020-4
ICS:
13.220.50 Požarna odpornost Fire-resistance of building
gradbenih materialov in materials and elements
elementov
91.060.50 Vrata in okna Doors and windows
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2016
ICS 13.220.50; 91.060.50
English Version
Extended application of test results on durability of self-
closing for doorsets and openable windows - Part 4:
Durability of self-closing of fire resistance hinged and
pivoted metal framed glazed doorsets and openable
windows
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 33.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 17020-4:2016 E
worldwide for CEN national Members.
Contents Page
European foreword . 3
Introduction . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 6
4 Determination of the field of extended application . 6
4.1 General . 6
4.2 Procedure for evaluation . 6
4.3 Procedure for maximum field of extended application . 7
4.4 Interpretation of test results . 8
5 Extended application report . 8
6 Classification report . 8
Annex A (normative) Construction parameter variations . 9
Annex B (normative) Construction parameter variation simulation by applying additional
weights . 50
European foreword
This document (prEN 17020-4:2016) has been prepared by Technical Committee CEN/TC 33 “Doors,
windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR.
This document is currently submitted to the CEN Enquiry.
Introduction
The EN 15269 series of standards covering extended application of test results for fire resistance
and/or smoke control for door, shutter and openable window assemblies, including their elements of
building hardware, does not include the durability of self-closing of the doorsets following an extended
application process. This document is one of a series of standards intended to be used for the purpose
of producing an extended application report based on the evaluation of one or more durability self-
closing tests. These European Standards may also be used to identify the best selection of test
specimens required to cover a wide range of product variations.
Before there can be any consideration for extended application, the doorset will need to have been
tested in accordance with EN 1634-1 resp. EN 1634-3 and EN 1191 to achieve a test result which could
generate a classification in accordance with EN 13501-2 at least equal to the classification subsequently
required from extended application considerations.
1 Scope
This Europan Standard covers single and double leaf, hinged and pivoted metal framed, glazed doorsets
or openable windows as covered by EN 15269-5.
This document prescribes the methodology for extending the application of test results obtained from
durability self-closing test(s) conducted in accordance with EN 1634 1.
Subject to the completion of the appropriate self-closing test or tests the extended application may
cover all or some of the following non-exhaustive list:
— Integrity only (E), radiation (EW) or insulated (EI1 or EI2) classifications;
— doorsets and openable windows
— door / window leaf;
— wall/ceiling fixed elements (frame/suspension system);
— glazing and non-glazed panels in doorset and openable window;
— items of building hardware;
— decorative finishes;
— intumescent, smoke, draught or acoustic seals;
— alternative supporting construction(s).
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
EN 1191, Windows and doors - Resistance to repeated opening and closing - Test method
EN 1363-1, Fire resistance tests - Part 1: General Requirements
EN 1634-1, Fire resistance and smoke control tests for door and shutter assemblies, openable windows and
elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable
windows
EN 1634-3, Fire resistance and smoke control tests for door and shutter assemblies, openable windows and
elements of building hardware - Part 3: Smoke control test for door and shutter assemblies
EN 13501-2:2007+A1:2009, Fire classification of construction products and building elements — Part 2:
Classification using data from fire resistance tests, excluding ventilation services
EN 15269-1:2010, Extended application of test results for fire resistance and/or smoke control for door,
shutter and openable window assemblies, including their elements of building hardware - Part 1: General
requirements
EN 15269-5:2014, Extended application of test results for fire resistance and/or smoke control for door,
shutter and openable window assemblies, including their elements of building hardware - Part 5: Fire
resistance of hinged and pivoted metal framed glazed doorsets and openable windows
EN 15269-20, Extended application of test results for fire resistance and/or smoke control for door,
shutter and openable window assemblies, including their elements of building hardware - Part 20: Smoke
control for hinged and pivoted steel, timber and metal framed glazed doorsets
EN ISO 13943, Fire safety - Vocabulary (ISO 13943:2008)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 1191, EN 1363-1,
EN ISO 13943, EN 1634-1, EN 1634-3, EN 15269-1, EN 15269-5 and EN 15269-20 and the following
apply.
3.1
full scale test
test of a full size doorset/openable window in accordance with EN 1191
4 Determination of the field of extended application
4.1 General
4.1.1 Before there can be any consideration for extended application the doorset/openable window
shall have been tested and classified in accordance with EN 1191 and EN 13501-2 in order to establish a
classification for the doorset/openable window. Before the extended application process can be applied
on a construction parameter variation it shall be ensured that the varied doorset/openable window is
able to self-close without restraint at least once.
4.1.2 A review of the doorset/openable window construction parameters can indicate that one or
more characteristics may be improved by a particular parameter variation. All evaluations shall be
made on the basis of retaining the classifications obtainable from testing to EN 1191, including those
with a lower number of opening and closing cycles. However, this shall never lead to an increased
classification for any specific parameter beyond that achieved by testing unless specifically identified in
the relevant Construction Parameter Variation tables.
4.1.3 All evaluations shall be made on the basis of retaining the classification obtained from testing to
EN 1191.
4.1.4 When following the extended application procedure, any part of the classified product, which
cannot be covered by the extended application rules, shall be omitted from the subsequent extended
application report and classification report.
4.2 Procedure for evaluation
4.2.1 Identify the variations from the original test specimen(s) which are required to be covered by
an extended application report.
4.2.2 Locate the variations in the appropriate parameter variation by reference to columns (1) and
(2) of Table A.1.
4.2.3 Establish from the contents of column (4) of Table A.1 whether any extended application is
available without the need for further testing.
4.2.4 Where this is deemed to be possible this can be recorded in the extended application report
together with any appropriate restrictions and the stated rules from column (4) in Table A.1.
4.2.5 Where the variations required can only be achieved from additional testing according to column
(5), the additional test can be made on a similar specimen type to the original test against which the
extended application is sought. Alternatively, column (5) in Table A.1 identifies an option for alternative
testing and relevant test parameters.
4.3 Procedure for maximum field of extended application
4.3.1 It is possible to provide a limited field of extended application from the results of a single test.
However, where a manufacturer intends to produce a range of doorsets and openable windows
incorporating single doors and also double doors with or without glazing, with alternative elements of
building hardware, etc., it is recommended that careful consideration is given to the complete range of
doorset designs and openable window designs and options in order to minimize the testing required
before testing commences.
4.3.2 Establish all the parameter variations which are required to be part of the product range.
4.3.3 Determine which are the most important specification requirements and incorporate as many
as possible into the specimen(s) for the first tests in the series.
4.3.4 Conduct the first durability test or a series of tests and then establish which of the original
desired parameter variations have not been covered by this test(s).
4.3.5 Identify these parameter variations in Table A.1 and establish if any extended application is
possible without further testing.
4.3.6 Record this for the extended application report together with any restrictions and rules given in
column (4) in Table A.1.
4.3.7 Evaluate which, if any, of the desired parameter variations have not been covered by the initial
field of extended application derived from 4.3.6 above.
4.3.8 Determine if the product range is to include only single leaf doorsets or if the range is to also
include double leaf configurations.
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.