1.1   General
This European Standard identifies material independent, safety and performance requirements applicable to all fire resisting and/or smoke control products intended to be used in fire and/or smoke compartmentation and/or escape routes, which are either:
-   industrial, commercial and/or garage doorsets, rolling shutters or operable fabric curtains intended for the installation in areas in the reach of persons and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons, or
-   rolling shutters or operable fabric curtains used in retail premises which are mainly provided for the access of persons rather than vehicles or goods, or
-   pedestrian doorsets and/or openable windows and/or inspection hatches which are hinged or sliding, intended for the installation in areas in the reach of persons, and for which the main intended uses are giving safe access for persons
and which are manually or power operated and:
-   opening and self closing as a normal mode of operation, or
-   normally held open but self closing in case of fire or smoke, or
-   normally maintained locked in the closed position (e. g. service access/inspection doorsets)
and completed:
-   with building hardware,
-   with or without any side panel(s), flush over panel(s) and/or transom panel(s) (with or without glazing) and contained within a single perimeter frame for inclusion in a single aperture,
-   with or without any vision panel(s) in the door leaf or leave(s),
-   with or without any seals (e.g. for smoke control, fire resistance, draught, acoustic or weather characteristics).
Product characteristics covered in EN 13241 1, EN 14351 1, prEN 14351 2 or EN 16361 will not compromise the fire resistance and/or smoke control characteristics of a fire resisting and/or smoke control product.
NOTE 1   Requirements included in EN 14351-1, prEN 14351-2, EN 13241-1 or EN 16361 might be relevant for the products covered by this standard.
This standard also provides indications on the product modifications not affecting the performances of the concerned products.
NOTE 2   The requirements and rules for variations (regarding the direct and extended field of applications) of fire resistance and/or smoke control doorsets are given in the EN 15269 series and EN 1634-1 and EN 1634-3, supported by, e.g. EN 16035.
1.2   Exclusions
This European Standard does not cover:
-   fixed windows, glazed side panels and/or overpanels, which are not an integral part of a doorset and/or openable window;
-   door assemblies produced with components from several sources where there is no single identified manufacturer or legal entity who will take responsibility for them;
-   operation in environments where the electromagnetic disturbances are outside the range of those specified in EN 61000 6 3;
-   radio operating devices fitted to doorsets and/or openable windows; where such items are fitted, the relevant ETSI standards should be applied in addition.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers steel rolling shutters as covered by EN 15269 10.
This document prescribes the methodology for extending the application of test results obtained from durability self-closing test(s) conducted in accordance with EN 1634 1.
Subject to the completion of the appropriate self-closing test or tests, the extended application may cover all or some of the following non-exhaustive list:
-   Integrity only (E), radiation (EW) or insulated (EI1 or EI2) classifications;
-   shutter curtain;
-   wall/ceiling fixed elements (frame/suspension system);
-   decorative finishes;
-   intumescent, smoke, draught or acoustic seals;
-   alternative supporting construction(s).

  • Draft
    59 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers single and double leaf, hinged and pivoted, steel based doorsets covered by EN 15269 2.
This document prescribes the methodology for extending the application of test results obtained from durability self-closing test(s) conducted in accordance with EN 1191.
Subject to the completion of the appropriate self-closing test or tests, the extended application may cover all or some of the following examples:
-   door leaf;
-   side, transom and/or overpanels;
-   ventilation grilles and/or louvres
-   wall/ceiling fixed elements (frame/suspension system);
-   glazing for door leaf, side, transom and flush over panels;
-   items of building hardware;
-   decorative finishes;
-   intumescent, smoke, draught or acoustic seals;
-   alternative supporting construction(s).

  • Draft
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Europan Standard covers single and double leaf, hinged and pivoted metal framed, glazed doorsets or openable windows as covered by EN 15269 5.
This document prescribes the methodology for extending the application of test results obtained from durability self-closing test(s) conducted in accordance with EN 1634 1.
Subject to the completion of the appropriate self-closing test or tests the extended application may cover all or some of the following non-exhaustive list:
-   Integrity only (E), radiation (EW) or insulated (EI1 or EI2) classifications;
-   doorsets and openable windows
-   door / window leaf;
-   wall/ceiling fixed elements (frame/suspension system);
-   glazing and non-glazed panels in doorset and openable window;
-   items of building hardware;
-   decorative finishes;
-   intumescent, smoke, draught or acoustic seals;
-   alternative supporting construction(s).

  • Draft
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers the following types of steel based doorsets: horizontally sliding doorsets (single and double), telescopic doorsets (single and double) and single vertically sliding doorsets as covered by EN 15269 7.
This document prescribes the methodology for extending the application of test results obtained from durability self-closing test(s) conducted in accordance with EN 1634 1.
Subject to the completion of the appropriate self-closing test or tests, the extended application may cover all or some of the following non-exhaustive list:
-   integrity only (E), radiation (EW) or insulated (EI1 or EI2) classifications;
-   door leaf;
-   wall/ceiling fixed elements (frame/suspension system);
-   glazing for door leaf;
-   items of building hardware;
-   decorative finishes;
-   intumescent, smoke, draught or acoustic seals;
-   alternative supporting construction(s).

  • Draft
    59 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the performance characteristics for resistance to fire and/or smoke leakage characteristics of windows, pedestrian doorsets and Industrial, commercial and garage doors