ENV 1996-1-3:1998
(Main)Eurocode 6: Design of masonry structures - Part 1-3: General rules for buildings - Detailed rules on lateral loading
Eurocode 6: Design of masonry structures - Part 1-3: General rules for buildings - Detailed rules on lateral loading
(1)P This Part 1-3 of ENV 1996 deals with the design of unreinforced masonry walls subjected to lateral wind loads and horizontal accidental loads (other than seismic actions) and shall be used in conjunction with ENV 1996-1-1. (2) This Part 1-3 of ENV 1996 gives Principles and Application Rules (see clause 1.2 in ENV 1996-1-1) for designing structures for specified requirements in respect of the aforementioned functions and levels of performance.
Eurocode 6: Bemessung und Konstruktion von Mauerwerksbauten Teil 1-3: Allgemeine Regeln -Detaillierte Regeln bei horizontaler Belastung
Eurocode 6: Calcul des ouvrages en maçonnerie - Partie 1-3: Règles générales - Règles particulières pour les charges latérales
Eurocode 6: Projektiranje zidanih konstrukcij – 1-3. del: Splošna pravila za stavbe – Podrobna pravila za bočno obtežbo
General Information
- Status
- Withdrawn
- Publication Date
- 16-Jun-1998
- Withdrawal Date
- 01-Nov-2005
- Technical Committee
- CEN/TC 250 - Structural Eurocodes
- Drafting Committee
- CEN/TC 250/SC 6 - Eurocode 6: Design of masonry structures
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 02-Nov-2005
- Completion Date
- 02-Nov-2005
Not Harmonized89/106/EEC - Construction products
Relations
- Effective Date
- 22-Dec-2008
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Referred By
EN ISO 21049:2004 - Pumps - Shaft sealing systems for centrifugal and rotary pumps (ISO 21049:2004) - Effective Date
- 28-Jan-2026
Get Certified
Connect with accredited certification bodies for this standard

ICC Evaluation Service
Building products evaluation and certification.

QAI Laboratories
Building and construction product testing and certification.

Aboma Certification B.V.
Specialized in construction, metal, and transport sectors.
Sponsored listings
Frequently Asked Questions
ENV 1996-1-3:1998 is a standardization document published by the European Committee for Standardization (CEN). Its full title is "Eurocode 6: Design of masonry structures - Part 1-3: General rules for buildings - Detailed rules on lateral loading". This standard covers: (1)P This Part 1-3 of ENV 1996 deals with the design of unreinforced masonry walls subjected to lateral wind loads and horizontal accidental loads (other than seismic actions) and shall be used in conjunction with ENV 1996-1-1. (2) This Part 1-3 of ENV 1996 gives Principles and Application Rules (see clause 1.2 in ENV 1996-1-1) for designing structures for specified requirements in respect of the aforementioned functions and levels of performance.
(1)P This Part 1-3 of ENV 1996 deals with the design of unreinforced masonry walls subjected to lateral wind loads and horizontal accidental loads (other than seismic actions) and shall be used in conjunction with ENV 1996-1-1. (2) This Part 1-3 of ENV 1996 gives Principles and Application Rules (see clause 1.2 in ENV 1996-1-1) for designing structures for specified requirements in respect of the aforementioned functions and levels of performance.
ENV 1996-1-3:1998 is classified under the following ICS (International Classification for Standards) categories: 91.010.30 - Technical aspects; 91.080.30 - Masonry. The ICS classification helps identify the subject area and facilitates finding related standards.
ENV 1996-1-3:1998 has the following relationships with other standards: It is inter standard links to EN 1996-1-1:2005, EN ISO 10437:2003, EN ISO 10440-1:2007, EN ISO 13705:2012, EN ISO 13631:2002, EN ISO 10438-1:2007, EN ISO 16330:2003, EN ISO 21049:2004. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ENV 1996-1-3:1998 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC; Standardization Mandates: M/BC/CEN/89/11. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
ENV 1996-1-3:1998 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2004
(XURFRGH3URMHNWLUDQMH]LGDQLKNRQVWUXNFLM±GHO6SORãQDSUDYLOD]DVWDYEH
±3RGUREQDSUDYLOD]DERþQRREWHåER
Eurocode 6: Design of masonry structures - Part 1-3: General rules for buildings -
Detailed rules on lateral loading
Eurocode 6: Bemessung und Konstruktion von Mauerwerksbauten Teil 1-3: Allgemeine
Regeln -Detaillierte Regeln bei horizontaler Belastung
Eurocode 6: Calcul des ouvrages en maçonnerie - Partie 1-3: Regles générales - Regles
particulieres pour les charges latérales
Ta slovenski standard je istoveten z: ENV 1996-1-3:1998
ICS:
91.010.30 7HKQLþQLYLGLNL Technical aspects
91.080.30 Zidane konstrukcije Masonry
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...