EN 15207:2014
(Main)Tanks for the transport of dangerous goods - Plug/socket connection and supply characteristics for service equipment in hazardous areas with 24 V nominal supply voltage
Tanks for the transport of dangerous goods - Plug/socket connection and supply characteristics for service equipment in hazardous areas with 24 V nominal supply voltage
This European Standard specifies the interoperability requirements for the tractor/trailer and/or transport tank/trailer plug/socket for the use in hazardous areas, being:
- the connection used for the supply Type A and supply Type S electrical power to service equipment; and
- the supply characteristics for each operating mode.
This plug/socket combination includes provisions for future connections including data transfer.
The plug/socket connection is not used for purposes which are specified in other standards for truck - trailer connections e.g. ISO 12098 and ISO 7638-1.
Tanks für die Beförderung gefährlicher Güter - Steckvorrichtung und elektrische Kennwerte der Versorgung von Bedienungsausrüstungen in explosionsgefährdeten Bereichen mit 24 V Nennspannung
Diese Europäische Norm legt die Anforderungen an die Interoperabilität der Verbindung aus Stecker und Steckdose (Steckvorrichtung) zwischen Zugmaschine/Anhänger und/oder Transporttank/Anhänger zur Verwendung in explosionsgefährdeten Bereichen wie folgt fest:
- für die Verbindung für die Spannungsversorgungen Typ A und Typ S der Bedienungsausrüstung und
- für die Kennwerte der elektrischen Versorgung für jede Betriebsart.
Diese Steckvorrichtung umfasst auch Bereitstellungen für zukünftige Anschlüsse einschließlich solcher für die Datenübertragung.
Die Steckvorrichtung ist nicht für die in anderen Normen zu Steckvorrichtungen zwischen Zugmaschine/Anhänger (z. B. in ISO 12098 und ISO 7638 1) festgelegten Zwecke verwendbar.
Citernes destinées au transport des matières dangereuses - Prises et embases de raccordement, caractéristiques de l'alimentation électrique des équipements de service en atmosphères explosibles, à tension nominale de 24 V
La présente Norme européenne spécifie les exigences d’interopérabilité applicables aux prises et embases de tracteur/remorque et/ou citerne de transport/remorque en atmosphères explosibles. Ces exigences concernent :
- les connexions utilisées pour les alimentations électriques de Type A et S des équipements de service ; et
- les caractéristiques de l’alimentation électrique de chaque mode de fonctionnement.
Cette combinaison prise/embase inclut des dispositions en vue de raccordements ultérieurs, y compris le transfert de données.
Ces prises et embases de raccordement ne sont pas utilisables pour les besoins spécifiés dans d’autres normes relatives aux raccordements camion/ remorque, comme par exemple les normes ISO 12098 ou ISO 7638-1.
Cisterne za prevoz nevarnega blaga - Vtična zveza in napajalne karakteristike za opremo za obratovanje z nazivno napajalno napetostjo 24 V v eksplozijsko ogroženih območjih
General Information
- Status
- Published
- Publication Date
- 09-Dec-2014
- Technical Committee
- CEN/TC 296 - Tanks for transport of dangerous goods
- Drafting Committee
- CEN/TC 296/WG 8 - Electronic equipment and products
- Current Stage
- 9093 - Decision to confirm - Review Enquiry
- Start Date
- 19-Nov-2020
- Completion Date
- 23-Sep-2025
Relations
- Effective Date
- 30-Apr-2011
Overview
EN 15207:2014 specifies interoperability requirements for plug/socket connections and 24 V supply characteristics used on tanks for the transport of dangerous goods. It covers the electrical interface between tractor/trailer and transport tank/trailer for operation in potentially explosive (hazardous) atmospheres and defines both the non‑interruptible (Type A) and interruptible (Type S) supplies. The standard also provides provisions for future data‑transfer connections while excluding functions covered by other truck–trailer standards (e.g. ISO 12098, ISO 7638‑1).
Key topics and technical requirements
- Supply types and ratings
- Two supplies defined: Supply Type A (designed to remain active in hazardous areas) and Supply Type S (designed to be switched off in hazardous areas).
- Nominal voltage: 24 V DC. Both supplies are to be fused for explosion protection with 5 A fuses.
- Connector design
- 15‑pin plug/socket configuration with a fixed pin assignment. Example functions include RS‑485 primary data lines (pins 1–3), RS‑232/CAN secondary data lines (pins 5–8) and dedicated pins for Supply Type A (pin 9, 13) and Supply Type S (pins 4, 6).
- Mechanical keying and a captive, self‑locking screw (M4×16) to prevent accidental disconnection; insertion of a mismatching connector (≤ 1 000 N) must not create electrical contact.
- Current per non‑power pin limited to < 4 A.
- Hazardous‑area compliance
- Equipment category 2, gas group IIC, temperature class T6. Conformance to EN 60079‑0 and EN 60079‑7 with isolation requirements per EN 60079‑7 (DC voltages ≤ 60 V).
- Operational range & testing
- Ambient range: −40 °C to +60 °C.
- Tests referenced: ISO 12098, EN ISO 8092‑2, ISO 16750‑3, EN 60079‑7, and mismatching test per ISO 4091.
- Marking
- Type plate information per EN 60079‑0 and EN 15207; warning signage for connection/disconnection in hazardous areas as required by EN 60079‑7.
Applications and users
- Intended for tank manufacturers, trailer/tractor OEMs, electrical/system integrators, fleet operators, installers, test laboratories and certification bodies involved in the design, manufacture, installation and maintenance of service equipment on vehicles transporting dangerous goods.
- Typical use cases: power and data interfaces for overfill prevention, product recognition devices, cabin service equipment and trailer-mounted control systems where safe operation in explosive atmospheres is required.
Related standards
- EN 60079‑0, EN 60079‑7 (explosive atmospheres)
- ISO 12098, ISO 4091, EN ISO 8092‑2, ISO 16750‑3 (vehicle connector and test requirements)
- EN 13616, EN 13922, EN 14116, EN 15208, EN 15969 (related tank interfaces and data standards)
Keywords: EN 15207:2014, tanks for the transport of dangerous goods, plug/socket connection, 24 V nominal supply voltage, hazardous areas, supply Type A, supply Type S, pin assignment, EN 60079.
Frequently Asked Questions
EN 15207:2014 is a standard published by the European Committee for Standardization (CEN). Its full title is "Tanks for the transport of dangerous goods - Plug/socket connection and supply characteristics for service equipment in hazardous areas with 24 V nominal supply voltage". This standard covers: This European Standard specifies the interoperability requirements for the tractor/trailer and/or transport tank/trailer plug/socket for the use in hazardous areas, being: - the connection used for the supply Type A and supply Type S electrical power to service equipment; and - the supply characteristics for each operating mode. This plug/socket combination includes provisions for future connections including data transfer. The plug/socket connection is not used for purposes which are specified in other standards for truck - trailer connections e.g. ISO 12098 and ISO 7638-1.
This European Standard specifies the interoperability requirements for the tractor/trailer and/or transport tank/trailer plug/socket for the use in hazardous areas, being: - the connection used for the supply Type A and supply Type S electrical power to service equipment; and - the supply characteristics for each operating mode. This plug/socket combination includes provisions for future connections including data transfer. The plug/socket connection is not used for purposes which are specified in other standards for truck - trailer connections e.g. ISO 12098 and ISO 7638-1.
EN 15207:2014 is classified under the following ICS (International Classification for Standards) categories: 13.300 - Protection against dangerous goods; 23.020.20 - Vessels and containers mounted on vehicles. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 15207:2014 has the following relationships with other standards: It is inter standard links to EN 15207:2006. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 15207:2014 is associated with the following European legislation: EU Directives/Regulations: 2008/68/EC, 94/9/EC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 15207:2014 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.R]LMVNRTanks für die Beförderung gefährlicher Güter - Steckvorrichtung und elektrische Kennwerte der Versorgung von Bedienungsausrüstungen in explosionsgefährdeten Bereichen mit 24 V NennspannungCiternes destinées au transport des matières dangereuses - Prises et embases de raccordement, caractéristiques de l'alimentation électrique des équipements de service en atmosphères explosibles, à tension nominale de 24 VTanks for the transport of dangerous goods - Plug/socket connection and supply characteristics for service equipment in hazardous areas with 24 V nominal supply voltage23.020.20Posode in vsebniki, montirani na vozilaVessels and containers mounted on vehicles13.300Varstvo pred nevarnimi izdelkiProtection against dangerous goodsICS:Ta slovenski standard je istoveten z:EN 15207:2014SIST EN 15207:2015en,fr,de01-marec-2015SIST EN 15207:2015SLOVENSKI
STANDARDSIST EN 15207:20071DGRPHãþD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 15207
December 2014 ICS 23.020.20 Supersedes EN 15207:2006English Version
Tanks for the transport of dangerous goods - Plug/socket connection and supply characteristics for service equipment in hazardous areas with 24 V nominal supply voltage
Citernes destinées au transport des matières dangereuses -Prises et embases de raccordement, caractéristiques de l'alimentation électrique des équipements de service en atmosphères explosibles, à tension nominale de 24 V
Tanks für die Beförderung gefährlicher Güter - Steckvorrichtung und elektrische Kennwerte der Versorgung von Bedienungsausrüstungen in explosionsgefährdeten Bereichen mit 24 V NennspannungThis European Standard was approved by CEN on 2 November 2014.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15207:2014 ESIST EN 15207:2015
EN 15207:2006. According to edition EN 15207:2006 the following fundamental changes are given: — the pin- assignment in Table 1 revised; — Subclause 4.1 “Service equipment energy consumption” deleted. This European Standard forms part of a coherent standards programme comprising the following standards: − EN 13616, Overfill prevention devices for static tanks for liquid petroleum fuels − EN 13922, Tanks for transport of dangerous goods — Service equipment for tanks — Overfill prevention systems for liquid fuels − EN 14116, Tanks for transport of dangerous goods — Digital interface for the product recognition device for liquid fuels − EN 15208, Tanks for transport of dangerous goods — Sealed parcel delivery systems — Working principles and interface specifications − EN 15969-1, Tanks for transport of dangerous goods — Digital interface for the data transfer between tank vehicle and with stationary facilities — Part 1: Protocol specification — Control, measurement and event data − EN 15969-2, Tanks for transport of dangerous goods — Digital interface for the data transfer between tank vehicle and with stationary facilities — Part 2: Commercial and logistic data According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 15207:2015
...










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.