Determination of moisture content of autoclaved aerated concrete

This European Standard specifies the procedure for the determination of the moisture content of prefabricated components of autoclaved aerated concrete (AAC).

Bestimmung des Feuchtegehalts von dampfgehärtetem Porenbeton

Diese Europäische Norm beinhaltet das Verfahren zur Bestimmung des Feuchtegehalts von vorgefertigten Bauteilen aus dampfgehärtetem Porenbeton (AAC).

Détermination du taux d'humidité du béton cellulaire autoclavé

Cette norme européenne spécifie la procédure de détermination du taux d'humidité   des composants préfabriqués en béton cellulaire autoclavé (AAC).

Določevanje deleža vlage v avtoklaviranem celičastem betonu

General Information

Status
Published
Publication Date
10-Dec-1996
Withdrawal Date
29-Jun-1997
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
15-Mar-2022

Overview

EN 1353:1996 - Determination of moisture content of autoclaved aerated concrete (AAC) - is a European Standard published by CEN. The standard defines the procedure for determining moisture content of prefabricated components made from autoclaved aerated concrete. It has been adopted by national bodies (for example, SIST EN 1353:2001 in Slovenia) and is classified under ICS 91.100.30 (Concrete and concrete products).

Key topics and requirements

EN 1353:1996 focuses on standardized, repeatable measurement of moisture content in AAC. Key technical topics typically addressed in the standard include:

  • Scope and definitions relevant to moisture measurement for prefabricated AAC components.
  • Sampling and specimen selection to ensure representative testing of prefabricated elements.
  • Specimen preparation and conditioning prior to measurement to control variables.
  • Measurement procedure for determining moisture content and the method for calculating results.
  • Expression and reporting of results, including how moisture content is presented and recorded.
  • Accuracy, repeatability and documentation requirements to support quality control and traceability. Note: this listing reflects the standard’s thematic content; consult the official EN 1353 document for exact procedural steps and measurement conventions.

Applications and who uses it

EN 1353:1996 is used where reliable moisture data for AAC prefabricated components is required:

  • AAC manufacturers - for production quality control and batch verification.
  • Construction materials testing laboratories - to provide accredited moisture measurements.
  • Specifiers, architects and structural engineers - to assess suitability of AAC elements for indoor/outdoor use and finishing.
  • Contractors and installers - to verify drying state prior to assembly, plastering or cladding.
  • Regulatory bodies and certification schemes - to demonstrate compliance with performance criteria and building regulations. Accurate moisture content measurement helps avoid issues such as poor adhesion of finishes, dimensional instability, and reduced thermal performance.

Related standards and classification

  • Classified under ICS 91.100.30 (Concrete and concrete products).
  • National adoptions (e.g., SIST EN 1353:2001) reflect EN 1353:1996 in local standards catalogs. For precise procedural details, sampling sizes, conditioning times and reporting formats, obtain the official EN 1353:1996 text from CEN or your national standards body.

Keywords: EN 1353, autoclaved aerated concrete, AAC, moisture content, moisture testing, prefabricated AAC, CEN standard, concrete products, quality control.

Frequently Asked Questions

EN 1353:1996 is a standard published by the European Committee for Standardization (CEN). Its full title is "Determination of moisture content of autoclaved aerated concrete". This standard covers: This European Standard specifies the procedure for the determination of the moisture content of prefabricated components of autoclaved aerated concrete (AAC).

This European Standard specifies the procedure for the determination of the moisture content of prefabricated components of autoclaved aerated concrete (AAC).

EN 1353:1996 is classified under the following ICS (International Classification for Standards) categories: 91.100.30 - Concrete and concrete products. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 1353:1996 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 1353:1996 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Bestimmung des Feuchtegehalts von dampfgehärtetem PorenbetonDétermination du taux d'humidité du béton cellulaire autoclavéDetermination of moisture content of autoclaved aerated concrete91.100.30Beton in
...

Questions, Comments and Discussion