Abstract

This document covers, regardless of if manufactured in factories or in temporary plants on site under the same conditions, precast concrete elements made of lightweight concrete with an open structure, and with a dry density between 400 and 2000 kg/m3, intended to be used as structural element:
—   solid, hollow core and multilayer load-bearing wall elements;
—   retaining wall elements, excluding retaining walls intended to retain tanks or reservoirs of liquids and diaphragm walls (concrete sheet piling);
—   solid, hollow core and multilayer roof elements, excluding ribbed floor elements and floor slabs elements;
—   solid, hollow core and multilayer floor elements excluding floor elements with the intended use to carry traffic loads;
—   solid and hollow core beams;
—   solid piers.
This document covers, regardless of if manufactured in factories or in temporary plants on site under the same conditions, precast concrete elements made of lightweight concrete with an open structure, and with a dry density between 400 and 2000 kg/m3, intended for not to be used as structural use:
—   solid, hollow core and multilayer non-loadbearing wall elements;
—   cladding elements;
—   rectangular cross-section box culverts;
—   components for noise barriers.
NOTE   In addition to their loadbearing and encasing function, elements can also be used to provide fire resistance, sound insulation and thermal insulation.
Recycled lightweight concrete with an open structure (other than closed-loop recycling during production) is covered by this document.

Status
Published
Publication Date
21-Jul-2026
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
22-Jul-2026
Due Date
11-Dec-2026
Completion Date
11-Dec-2026

Buy Documents

EN 1520:2026 is a European Standard published by CEN for precast lightweight concrete products with an open structure. It specifies product characteristics, test and assessment methods, and AVCP provisions for elements made with lightweight concrete with a dry density between 400 and 2000 kg/m3. It is written for manufacturers, testing bodies, notified bodies, and project teams that need declared performance data for these products.

What does EN 1520:2026 specify?

EN 1520:2026 covers precast concrete elements made of lightweight concrete with an open structure, whether produced in factories or in temporary plants on site under the same conditions. It applies to both structural and non-structural products, and it also includes recycled lightweight concrete with an open structure other than closed-loop recycling during production.

In structural use, the standard covers load-bearing wall elements, retaining wall elements, roof elements, floor elements, beams, and solid piers. In non-structural use, it covers non-loadbearing wall elements, cladding elements, rectangular cross-section box culverts, and components for noise barriers.

The document is organized into six main clauses:

  • Scope
  • Normative references
  • Terms, definitions, symbols and abbreviations
  • Characteristics
  • Testing, assessment and sampling methods
  • Assessment and verification of constancy of performance - AVCP

Annex ZA links the technical clauses to the Construction Products Regulation framework for declaration of performance and CE marking.

Annex / partWhat it covers
ZA.1Scope and relevant characteristics, with product-specific tables ZA.1.1 to ZA.1.13
ZA.2AVCP systems for the covered products
ZA.3Assignment of AVCP tasks between manufacturer and notified body

What are the key requirements of EN 1520:2026?

EN 1520:2026 sets out the performance characteristics that have to be declared for each product group, then points to the test or assessment route used to support those declarations. In practice, this is the part a manufacturer uses to decide what must be measured, what may be calculated, and what can be declared from tabulated values or documentation.

Concrete properties and product classification

Clause 4.1 covers the concrete itself: compressive strength, dry density, modulus of elasticity, drying shrinkage, creep, freeze-thaw resistance, and corrosion protection. Clause 5.1 gives the related methods, including characteristic strength, density class, and conversions based on specimen dimensions.

For a producer, this means the concrete mix is not described only by recipe. It has to be linked to declared performance values that can support the intended use of the element.

Reinforcing steel and structural behaviour

Clause 4.2 covers reinforcing steel properties such as elongation at maximum load, elongation after fracture, stress ratio, tensile yield strength, and ultimate tensile strength. Clause 4.3 covers mechanical performance of the element, including longitudinal load, in-plane shear, out-of-plane shear, and joint rigidity, with matching test methods in Clause 5.3.

In practice, these clauses are the basis for showing that the reinforcement and the finished element work together as a structural product, especially for wall, beam, floor, roof, and pier applications.

Fire, thermal, water, and acoustic performance

Clause 4.4 covers reaction to fire and resistance to fire, including classification by testing, WFT, and WT for reaction to fire. Clause 4.5 covers thermal conductivity, Clause 4.6 water vapour permeability, and Clause 4.7 acoustic performance such as airborne sound insulation, impact sound insulation, and sound absorption coefficient.

This matters because the same element may be selected not only for load-bearing capacity but also for fire, thermal, moisture, or acoustic performance. Annex ZA shows which of these characteristics are relevant to each product type.

Dangerous substances and sustainability

Clauses 4.9 and 4.10 cover release of dangerous substances to indoor air and to soil and ground water. The standard names the substances to be assessed and gives the rounding approach used for the reported results. Clauses 4.11 and 5.11 cover environmental sustainability, including reference service life, life cycle assessment, resource use, waste, output flows, and biogenic carbon content.

For buyers and project teams, this section is important when product selection depends on emissions, leaching, or environmental product declaration data.

Documentation attached to the declaration of performance

Clause 4.12 and Clause 5.12 cover documents attached to the declaration of performance. EN 1520:2026 requires a set of drawings for all products, and for custom-made products it requires the applicable load and exposure scenarios and the supporting calculations or tabulated values.

That means the technical declaration is not just a list of values. It is tied to drawings, design assumptions, and the method used to obtain the declared performance.

AVCP, sampling, and factory production control

Clause 6 defines the assessment and verification of constancy of performance. It combines product assessment with factory production control (FPC), and it also covers initial inspection and continuing surveillance where applicable.

In practice, this is the compliance backbone of the standard: the manufacturer must control production consistently, and the product performance has to remain stable over time.

What terms does EN 1520:2026 define?

  • Product family - A group of products from one manufacturer for which assessment results for one product can apply to the rest of the range.
  • Lightweight aggregate (LWA) - Aggregate of mineral origin with the particle density or loose bulk density limits given in the standard.
  • LAC - Lightweight concrete with an open or porous structure, with a dry density between 400 and 2000 kg/m3, made with lightweight aggregates.
  • Recycled lightweight concrete - Material produced from crushed construction and demolition waste originating from lightweight concrete elements with an open structure.
  • Loadbearing element - An element designed to contribute to the mechanical resistance and stability of the works.
  • Non-loadbearing element - An element that mainly supports its own weight and does not contribute to the stability of the works.
  • FPC - Factory production control.
  • RH - Relative humidity.

Who uses EN 1520:2026?

EN 1520:2026 is used by precast concrete manufacturers, including producers working in factories and in temporary plants on site. They use it to classify products, test performance, prepare declarations of performance, and set up factory production control.

Testing laboratories use it for specimen preparation, mechanical testing, fire-related classification, acoustic testing, leaching tests, and sustainability-related assessments. Notified bodies use it where AVCP tasks require independent assessment or surveillance.

It is also relevant to designers, specifiers, quality managers, and buyers who need to select the right product type and understand which performance characteristics are declared for a given element.

What changed in EN 1520:2026 from the previous edition?

EN 1520:2026 supersedes EN 1520:2011.

Which standards are used with EN 1520:2026?

  • EN 206-1:2026 - Provides the concrete specification, performance, production, conformity, factory production control, and assessment criteria used as the base reference for concrete terms and properties.
  • CEN/TS 12390-9:2016 - Gives the freeze-thaw resistance test with de-icing salts.
  • EN 990:2002 - Covers corrosion protection verification for reinforcement in lightweight concrete with open structure.
  • EN 992:1995 - Gives the dry density test method.
  • EN 1352:1996 - Gives the static modulus of elasticity test under compression.
  • EN 1354:2005 and EN 1355:1996 - Cover compressive strength and creep strain testing.
  • EN 1364-1, EN 1365-1, EN 1365-2, EN 1365-3, EN 1365-4 - Provide fire resistance test methods for non-loadbearing and loadbearing walls, floors, roofs, beams, and columns.
  • EN 1745:2020 and EN 12664:2001 - Support thermal property determination.
  • EN 16516:2017+A1:2020 and EN 16637-1:2023 / EN 16637-2:2023 - Cover release of dangerous substances to indoor air and to soil and ground water.
  • EN 15804:2012+A2:2019 and EN 18185:2026 - Support environmental product declarations and product category rules.
  • EN ISO 10140-2:2021, EN ISO 10140-3:2021, EN ISO 717-1:2020, EN ISO 717-2:2020, EN ISO 12354-1:2017, EN ISO 12354-2:2017, EN ISO 354:2003 - Support airborne sound, impact sound, and sound absorption assessment.
  • EN ISO 12572:2016 and EN ISO 10456:2007 - Support water vapour transmission and hygrothermal property values.
  • EN ISO 15630-1:2019 and EN ISO 15630-2:2019 - Cover reinforcement test methods.

What does the EN 1520:2026 document contain?

EN 1520:2026 contains the product scope, definitions, performance characteristics, and the testing and assessment routes for lightweight concrete elements with an open structure. It also includes the AVCP framework and the Annex ZA tables that map product types to the relevant characteristics and assessment clauses.

The document gives tables for dangerous substances in indoor air and in soil and ground water, with the substances named for each exposure route. It also provides the technical structure for mechanical, fire, thermal, water, acoustic, and sustainability performance.

Section 5 is method-heavy: it covers specimen preparation, sampling, characteristic strength determination, density classification, modulus of elasticity, shrinkage, creep, freeze-thaw resistance, reinforcement tests, and test or calculation routes for acoustic and thermal properties. Annex ZA then translates these technical clauses into declaration-of-performance and CE marking use cases.

Relations

Effective Date
29-Jan-2025
Effective Date
07-Oct-2026
Effective Date
07-Oct-2026
Effective Date
07-Oct-2026
Effective Date
07-Oct-2026
Effective Date
07-Oct-2026
Effective Date
07-Oct-2026
Effective Date
07-Oct-2026
Effective Date
07-Oct-2026
Effective Date
07-Oct-2026
Effective Date
07-Oct-2026
Effective Date
07-Oct-2026
Effective Date
07-Oct-2026
Effective Date
07-Oct-2026
Effective Date
07-Oct-2026

Buy Documents

Get Certified

Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)

German Institute for Building Technology.

DAKKS Germany Verified

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

EN 1520:2026 is a standard published by the European Committee for Standardization (CEN). Its full title is "Precast lightweight concrete products with an open structure". This standard covers: This document covers, regardless of if manufactured in factories or in temporary plants on site under the same conditions, precast concrete elements made of lightweight concrete with an open structure, and with a dry density between 400 and 2000 kg/m3, intended to be used as structural element: — solid, hollow core and multilayer load-bearing wall elements; — retaining wall elements, excluding retaining walls intended to retain tanks or reservoirs of liquids and diaphragm walls (concrete sheet piling); — solid, hollow core and multilayer roof elements, excluding ribbed floor elements and floor slabs elements; — solid, hollow core and multilayer floor elements excluding floor elements with the intended use to carry traffic loads; — solid and hollow core beams; — solid piers. This document covers, regardless of if manufactured in factories or in temporary plants on site under the same conditions, precast concrete elements made of lightweight concrete with an open structure, and with a dry density between 400 and 2000 kg/m3, intended for not to be used as structural use: — solid, hollow core and multilayer non-loadbearing wall elements; — cladding elements; — rectangular cross-section box culverts; — components for noise barriers. NOTE In addition to their loadbearing and encasing function, elements can also be used to provide fire resistance, sound insulation and thermal insulation. Recycled lightweight concrete with an open structure (other than closed-loop recycling during production) is covered by this document.

This document covers, regardless of if manufactured in factories or in temporary plants on site under the same conditions, precast concrete elements made of lightweight concrete with an open structure, and with a dry density between 400 and 2000 kg/m3, intended to be used as structural element: — solid, hollow core and multilayer load-bearing wall elements; — retaining wall elements, excluding retaining walls intended to retain tanks or reservoirs of liquids and diaphragm walls (concrete sheet piling); — solid, hollow core and multilayer roof elements, excluding ribbed floor elements and floor slabs elements; — solid, hollow core and multilayer floor elements excluding floor elements with the intended use to carry traffic loads; — solid and hollow core beams; — solid piers. This document covers, regardless of if manufactured in factories or in temporary plants on site under the same conditions, precast concrete elements made of lightweight concrete with an open structure, and with a dry density between 400 and 2000 kg/m3, intended for not to be used as structural use: — solid, hollow core and multilayer non-loadbearing wall elements; — cladding elements; — rectangular cross-section box culverts; — components for noise barriers. NOTE In addition to their loadbearing and encasing function, elements can also be used to provide fire resistance, sound insulation and thermal insulation. Recycled lightweight concrete with an open structure (other than closed-loop recycling during production) is covered by this document.

EN 1520:2026 is classified under the following ICS (International Classification for Standards) categories: 91.100.30 - Concrete and concrete products. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 1520:2026 has the following relationships with other standards: It is inter standard links to EN 1520:2011, EN 1739:2007, EN ISO 10456:2007, EN 15804:2012+A2:2019, EN 13501-1:2018, EN 12504-1:2019, EN 1365-1:2012, EN ISO 717-2:2020, EN 13501-2:2023, EN 992:1995, EN 990:2002, EN ISO 12354-1:2017, EN ISO 1716:2018, EN ISO 10140-3:2021, EN 1355:1996. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 1520:2026 is associated with the following European legislation: EU Directives/Regulations: 305/2011; Standardization Mandates: M/100, M/609, M/627. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 1520:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms, definitions, symbols and abbreviations
  • 3.1 Terms and definitions
  • 3.1.1 product family
  • 3.1.2 lightweight aggregate
  • 3.1.3 lightweight concrete with an open structure
  • 3.1.4 recycled lightweight concrete
  • 3.1.5 concrete
  • 3.1.6 loadbearing element
  • 3.1.7 non-loadbearing element
  • 3.1.8 reinforced element
  • 3.2 Symbols
  • 3.3 Abbreviations
  • 4 Characteristics
  • 4.1 Concrete
  • 4.2 Reinforcing steel
  • 4.3 Mechanical performance
  • 4.4 Fire performance
  • 4.5 Thermal performance
  • 4.6 Water performance
  • 4.7 Acoustic performance
  • 4.8 Other performances
  • 4.9 Release of dangerous substances — indoor air
  • 4.10 Release of dangerous substances — soil and ground water
  • 4.11 Environmental sustainability
  • 4.12 Documents attached to the declaration of performances
  • 5 Testing, assessment and sampling methods
  • 5.1 Lightweight concrete with an open structure
  • 5.2 Reinforcing steel
  • 5.3 Mechanical performance
  • 5.4 Fire performance
  • 5.5 Thermal performance
  • 5.6 Water performance
  • 5.7 Acoustic performance
  • 5.8 Other performances
  • 5.9 Release of dangerous substances — indoor air
  • 5.10 Release of dangerous substances — soil and ground water
  • 5.11 Environmental sustainability
  • 5.12 Performances in attached documentation of the product
  • 6 Assessment and verification of constancy of performance — AVCP
  • 6.1 General
  • 6.2 Assessment of performance
  • 6.3 Verification of constancy of performance
  • 5.1.2 Dry density Every 250 m or twice per
  • 5.1.5 Shrinkage Every three years
  • Annex ZA
  • 6.2 taken at the intended use which are declared
  • Bibliography

1 Scope

This document covers, regardless of if manufactured in factories or in temporary plants on site under the same conditions, precast concrete elements made of lightweight concrete with an open structure, and

with a dry density between 400 and 2000 kg/m , intended to be used as structural element:

  • solid, hollow core and multilayer load-bearing wall elements;
  • retaining wall elements, excluding retaining walls intended to retain tanks or reservoirs of liquids and diaphragm walls (concrete sheet piling);
  • solid, hollow core and multilayer roof elements, excluding ribbed floor elements and floor slabs elements;
  • solid, hollow core and multilayer floor elements excluding floor elements with the intended use to carry traffic loads;
  • solid and hollow core beams;
  • solid piers.

This document covers, regardless of if manufactured in factories or in temporary plants on site under the same conditions, precast concrete elements made of lightweight concrete with an open structure, and

with a dry density between 400 and 2000 kg/m , intended for not to be used as structural use:

  • solid, hollow core and multilayer non-loadbearing wall elements;
  • cladding elements;
  • rectangular cross-section box culverts;
  • components for noise barriers.

NOTE In addition to their loadbearing and encasing function, elements can also be used to provide fire resistance, sound insulation and thermal insulation.

Recycled lightweight concrete with an open structure (other than closed-loop recycling during production) is covered by this document.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes the requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. CEN/TS 12390-9:2016, Testing hardened concrete - Part 9: Freeze-thaw resistance with de-icing salts - Scaling EN 206-1:2026, Concrete - Specification, performance, production and conformity - Part 1: Performance, requirements, factory production control and assessment criteria for individual values EN 990:2002, Test methods for verification of corrosion protection of reinforcement in autoclaved aerated concrete and lightweight aggregate concrete with open structure EN 991:1995, Determination of the dimension of prefabricated reinforced components made of autoclaved aerated concrete or lightweight aggregate concrete with open structure

SIST EN 1520:2026 EN 1520:2026 (E) EN 992:1995, Determination of the dry density of lightweight aggregate concrete with open structure EN 1352:1996, Determination of static modulus of elasticity under compression of autoclaved aerated concrete or lightweight aggregate concrete with open structure EN 1354:2005, Determination of compressive strength of lightweight aggregate concrete with open structure EN 1355:1996, Determination of creep strains under compression of autoclaved aerated concrete or lightweight aggregate concrete with open structure EN 1364-1:2015, Fire resistance tests for non-loadbearing elements - Part 1: Walls

EN 1365-1:2012, Fire resistance tests for loadbearing elements — Part 1: Walls EN 1365-2:2014, Fire resistance tests for loadbearing elements - Part 2: Floors and roofs EN 1365-3:1999, Fire resistance tests for loadbearing elements - Part 3: Beams EN 1365-4:1999, Fire resistance tests for loadbearing elements - Part 4: Columns EN 1739:2007, Determination of shear strength for in-plane forces of joints between prefabricated components of autoclaved aerated concrete or lightweight aggregate concrete with open structure EN 1740:1998, Performance test for prefabricated reinforced components made of autoclaved aerated concrete or lightweight aggregate concrete with open structure under predominantly longitudinal load (vertical components) EN 1741:1998, Determination of shear strength for out-of-plane forces of joints between prefabricated components made of autoclaved aerated concrete or lightweight aggregate concrete with open structure EN 1745:2020, Masonry and masonry products - Methods for determining thermal properties EN 1793-1:2025, Road traffic noise reducing devices - Test method for determining the acoustic performance - Part 1: Intrinsic characteristics - Sound absorption under diffuse sound field conditions EN 12664:2001, Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Dry and moist products of medium and low thermal resistance EN 13501-1:2018, Fire classification of construction products and building elements - Part 1: Classification using data from reaction to fire tests EN 13501-2:2023, Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance and/or smoke control tests, excluding ventilation services EN 13823:2020+A1:2022, Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item EN 15804:2012+A2:2019, Sustainability of construction works - Environmental product declarations - Core rules for the product category of construction products

As impacted by EN 1365-1:2012/AC:2013.

SIST EN 1520:2026 EN 1520:2026 (E) EN 16516:2017+A1:2020, Construction products: Assessment of release of dangerous substances - Determination of emissions into indoor air EN 16637-1:2023, Construction products: Assessment of release of dangerous substances - Part 1: Guidance for the determination of leaching tests and additional testing steps EN 16637-2:2023, Construction products: Assessment of release of dangerous substances - Part 2:

Horizontal dynamic surface leaching test EN 18185:2026, Sustainability of construction works - Environmental product declarations - Product Category Rules for precast lightweight concrete with an open structure and precast autoclaved aerated concrete EN ISO 354:2003, Acoustics - Measurement of sound absorption in a reverberation room (ISO 354:2003) EN ISO 717-1:2020, Acoustics - Rating of sound insulation in buildings and of building elements - Part 1:

Airborne sound insulation (ISO 717-1:2020) EN ISO 717-2:2020, Acoustics - Rating of sound insulation in buildings and of building elements - Part 2:

Impact sound insulation (ISO 717-2:2020) EN ISO 1182:2020, Reaction to fire tests for products - Non-combustibility test (ISO 1182:2020) EN ISO 1716:2018, Reaction to fire tests for products - Determination of the gross heat of combustion (calorific value) (ISO 1716:2018) EN ISO 10140-2:2021, Acoustics - Laboratory measurement of sound insulation of building elements - Part 2: Measurement of airborne sound insulation (ISO 10140-2:2021) EN ISO 10140-3:2021, Acoustics - Laboratory measurement of sound insulation of building elements - Part 3: Measurement of impact sound insulation (ISO 10140-3:2021)

EN ISO 10456:2007, Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values (ISO 10456:2007+ Cor. 1:2009) EN ISO 11925-2:2026, Reaction to fire tests - Ignitability of products subjected to direct impingement of flame - Part 2: Single-flame source test (ISO 11925-2:2026) EN ISO 12354-1:2017, Building acoustics - Estimation of acoustic performance of buildings from the performance of elements - Part 1: Airborne sound insulation between rooms (ISO 12354-1:2017) EN ISO 12354-2:2017, Building acoustics - Estimation of acoustic performance of buildings from the performance of elements - Part 2: Impact sound insulation between rooms (ISO 12354-2:2017) EN 12504-1:2019, Testing concrete in structures - Part 1: Cored specimens - Taking, examining and testing in compression

EN ISO 12572:2016, Hygrothermal performance of building materials and products — Determination of water vapour transmission properties (ISO 12572:2016)

As impacted by EN ISO 10456:2007/AC:2009.

As impacted by EN ISO 12572:2016/A1:2024.

SIST EN 1520:2026 EN 1520:2026 (E) EN ISO 15630-1:2019, Steel for the reinforcement and prestressing of concrete - Test methods - Part 1:

Reinforcing bars, rods and wire (ISO 15630-1:2019) EN ISO 15630-2:2019, Steel for the reinforcement and prestressing of concrete - Test methods - Part 2:

Welded fabric and lattice girders (ISO 15630-2:2019)

3 Terms, definitions, symbols and abbreviations

3.1 Terms and definitions

For the purposes of this document, the terms and definitions given in EN 206-1:2026 and the following apply.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https://www.iso.org/obp/
  • IEC Electropedia: available at https://www.electropedia.org/

3.1.1 product family

group of products produced by one manufacturer for which the assessment results for one or more characteristics from any one product within the range are valid for all other products within this range

3.1.2 lightweight aggregate

LWA 3 3 aggregate of mineral origin having a particle density not exceeding 2 000 kg/m (2,00 Mg/m ) or a loose 3 3 bulk density not exceeding 1 200 kg/m (1,20 Mg/m ) [SOURCE: EN 13055-1:2002, 3.2]

3.1.3 lightweight concrete with an open structure

LAC lightweight concrete with an open or porous structure having a dry density between 400 and

2 000 kg/m and made with lightweight aggregates (LWA)

3.1.4 recycled lightweight concrete

material produced from crushed construction and demolition waste originating from lightweight concrete with an open or porous structure elements

3.1.5 concrete

normal-weight concrete with a closed structure having a dry density between 2000 and 2 600 kg/m

3.1.6 loadbearing element

element designed to contribute to the mechanical resistance and stability of the works Note 1 to entry: Elements exposed mainly to wind loads or acting as part of fire-resisting walls are considered to be loadbearing.

SIST EN 1520:2026 EN 1520:2026 (E)

3.1.7 non-loadbearing element

element that mainly supports its own weight and does not contribute to the stability of the work

3.1.8 reinforced element

element with a reinforcement used for both structural and non-structural purposes

3.2 Symbols

3.2.1 General symbols

A area E modulus of elasticity f strength k coefficient, factor

3.2.2 Subscripts

c concrete parameter, compression dry dry state k characteristic value m mean

3.2.3 Symbols used in this document

A elongation at maximum load — reinforcing steel gt A total elongation at fracture — reinforcing steel t Ecm mean value of the modulus of elasticity of LAC f characteristic compressive strength of LAC ck f required minimum compressive strength of LAC cmin f required minimum compressive strength of a test set with n ≥ 6 test specimens c,n f required minimum compressive strength of each test set of three consecutive test specimens c,3 f characteristic value of strength parameters k f required minimum strength min f mean value of n strength results m,n K statistical coefficient for determination of characteristic strength (λ is used in EN 206-1) n n number of test specimens in a sample, number of test results Re yield strength, MPa R Upper yield strength, MPa eH R yield strength at 0,2 % plastic elongation, MPa p0,2 R tensile strength, MPa m

SIST EN 1520:2026 EN 1520:2026 (E) s standard deviation of n test results n η coefficient according to Formula (2)

λ thermal conductivity λ thermal conductivity in the dry state, determined at a mean test temperature of 10 °C 10dry μ moisture content, related to mass m ρ dry density of LAC

3.3 Abbreviations

FPC factory production control LAC lightweight concrete with an open structure RH relative humidity

4 Characteristics

4.1 Concrete

4.1.1 Compressive strength lightweight concrete with an open structure

The compressive strength of lightweight concrete with an open structure is an indication of the loadbearing capacity of an element.

When assessing compressive strength, this shall be determined in accordance with 5.1.2. The performance of compressive strength shall be expressed as a class.

4.1.2 Dry density lightweight concrete with an open structure

The dry density lightweight concrete with an open structure serves as a reference for the calculation of some mechanical values and thermal insulation properties of elements. When assessing dry density, this shall be determined in accordance with 5.1.3, the performance of density shall be expressed as a class.

4.1.3 Modulus of elasticity lightweight concrete with an open structure - testing

When assessing the modulus of elasticity using the test methods given in 5.1.4, the modulus of elasticity shall be expressed in MPa.

4.1.4 Modulus of elasticity lightweight concrete with an open structure - calculation

When assessing the modulus of elasticity using the calculation method given in 5.1.5, the modulus of elasticity shall be expressed in MPa.

4.1.5 Drying shrinkage lightweight concrete with an open structure- testing

When assessing drying shrinkage, this shall be determined in accordance with 5.1.6. The performance of drying shrinkage shall be expressed in mm/m, rounded to the nearest 0,01.

SIST EN 1520:2026 EN 1520:2026 (E)

4.1.6 Drying shrinkage lightweight concrete with an open structure – tabulated values

When using a tabulated value for drying shrinkage, the value given in 5.1.7 shall be used. The performance of drying shrinkage shall be expressed in mm/m, rounded to the nearest 0,01 together with the relevant relative humidity of the environment.

4.1.7 Creep lightweight concrete with an open structure - testing

Creep describes the deformation of lightweight concrete with an open structure under longer lasting stress-induced loading.

When assessing creep, this shall be determined in accordance with 5.1.8. The performance of creep shall be expressed in mm/m.

4.1.8 Freeze–thaw resistance of concrete

When assessing the freeze–thaw resistance of concrete, this shall be determined in accordance with 5.1.9

and expressed in kg/m . The freezing agent used shall be specified.

4.1.9 Corrosion protection

When assessing the corrosion protection of concrete, this shall be determined in accordance with 5.1.10. The type of corrosion protection (galvanized, stainless or coated steel) used shall be provided. The type of corrosion protection and the % of corroded surface area shall be provided. The performance of the corrosion protection shall be expressed as percentage.

4.2 Reinforcing steel

4.2.1 Elongation at maximum load — reinforcing steel

When assessing the elongation at maximum load of reinforcing steel (A ), this shall be determined in gt accordance with 5.2.1. The performance of elongation at maximum load of reinforcing steel shall be expressed as a ratio, rounded to the nearest 0,1.

4.2.2 Elongation after fracture — reinforcing steel

When assessing the elongation after fracture of reinforcing steel (A ), this shall be determined in r accordance with 5.2.2. The performance of elongation after fracture of reinforcing steel shall be expressed as a ratio, rounded to the nearest 0,1.

4.2.3 Stress ratio — reinforcing steel

When assessing the stress ratio of reinforcing steel (R /R ), this shall be determined in accordance with m e 5.2.3. The performance of stress ratio of reinforcing steel shall be expressed as a ratio, rounded to the nearest 0,01.

4.2.4 Tensile yield strength — reinforcing steel

When assessing the tensile yield strength of reinforcing steel (R ), this shall be determined in accordance e with 5.2.4. The performance of tensile yield strength of reinforcing steel shall be expressed in MPa, rounded to the nearest integer.

SIST EN 1520:2026 EN 1520:2026 (E)

4.2.5 Ultimate tensile strength — reinforcing steel

When assessing the ultimate tensile strength of reinforcing steel (R ), this shall be determined in m accordance with 5.2.5. The performance of ultimate tensile strength of reinforcing steel shall be expressed in MPa, rounded to the nearest integer.

4.3 Mechanical performance

4.3.1 Mechanical strength — testing — lightweight concrete with an open structure —

longitudinal load When assessing the mechanical strength of elements under longitudinal load, this shall be determined in accordance with 5.3.2. The performance of mechanical strength of elements under longitudinal load shall be expressed in MN The calculation and corresponding test method shall be part of the documentation provided with the declaration in accordance with 4.12.

4.3.2 Mechanical strength — testing — lightweight concrete with an open structure — rigidity of

joints–in-plane-shear When using the rigidity of joints in design the mechanical strength of joints under in-plane-shear shall be determined in accordance with 5.3.3. The performance mechanical strength of joints under in-planeshear shall be expressed in MPa. The calculation and corresponding test method shall be part of the documentation provided with the declaration in accordance with 4.12.

4.3.3 Mechanical strength — testing — lightweight concrete with an open structure — rigidity of

joints — out-of-plane-shear When using the rigidity of joints in design the mechanical strength of joints under out-of-plane-shear shall be determined in accordance with 5.3.4. The performance mechanical strength of joints under outof-plane-shear shall be expressed in MPa. The calculation and corresponding test method shall be part of the documentation provided with the declaration in accordance with 4.12.

4.4 Fire performance

4.4.1 Reaction to fire
4.4.1.1 Classification by testing

The reaction to fire indicates the response of a lightweight concrete with an open structure element in contributing by its own decomposition to a fire to which it is exposed, under specified conditions. When tested in accordance with the test method given in 5.4.1, relevant for the claimed class, the test results are expressed as a class according to the classification published in the Official Journal of the European Union on this specific matter.

NOTE The applicable document at the time this document was drafted is Commission Delegated Regulation (EU) 2016/364 of 1 July 2015. https://eur-lex.europa.eu/eli/reg_del/2016/364

4.4.1.2 Classification without further testing (WFT)

Whether products covered by this document fulfil the conditions, under which they have demonstrated of having a stable reaction to fire performance in a given reaction to fire class, based on testing to the

SIST EN 1520:2026 EN 1520:2026 (E) appropriate EN test methods, the established assigned class applies to these products without the need of carrying out further reaction to fire tests.

NOTE The rules to apply this classification are published as Commission Decisions or Commission Delegated Regulations.

4.4.1.3 Classification without testing (WT)

Whether products covered by this document are made from one or more of the materials that have been considered, under established conditions, as belonging to the category “No contribution to fire” because of their low level of combustibility, the reaction to fire class A1 applies to these products without the need of carrying out reaction to fire tests.

NOTE The applicable document at the time this document was drafted is Commission Decision 96/603/EC, Materials to be considered as reaction to fire Class A1 without the need for testing as amended by Commission Decision 2000/605/EC of 26 September 2000 (see OJEU L, 2000–10–12) and Commission Decision 2003/424/EC of 6 June 2003

...