EN 1865-2:2010+A1:2015
(Main + Amendment)Patient handling equipment used in road ambulances - Part 2: Power assisted stretcher
Patient handling equipment used in road ambulances - Part 2: Power assisted stretcher
This European Standard defines minimum requirements for the design and performance of power assisted stretchers used in road ambulances for the treatment and transportation of patients. It aims to ensure patient safety and minimize the physical effort required by staff operating the equipment.
Krankentransportmittel im Krankenkraftwagen - Teil 2: Kraftunterstützte Krankentrage
Diese Europäische Norm legt die Mindestanforderungen an die Ausführung und Gebrauchstauglichkeit von kraftunterstützten Krankentragen fest, die im Krankenkraftwagen für die Behandlung und den Transport von Patienten verwendet werden. Es ist das Ziel, für die Sicherheit des Patienten zu sorgen und die körperliche Anstrengung des Personals, das dieses Transportmittel bedient, zu minimieren.
Spécifications d'équipements pour le transport de patient dans les ambulances routières - Partie 2: Brancard motorisé
La présente norme européenne définit les exigences minimales requises en matière de conception et de performances des brancards motorisés utilisés dans les ambulances pour le traitement et le transport des patients afin de réduire les efforts physiques des personnels utilisant ces équipements et d’assurer la sécurité du patient.
Oprema za ravnanje s pacienti v reševalnih vozilih - 2. del: Nosila s pomožnim pogonom
Ta evropski standard določa minimalne zahteve za konstruiranje in zmogljivost bolniških nosil s pomožnim pogonom v reševalnih vozilih za ravnanje s pacienti in njihov prevoz. Njegov namen je zagotoviti varnost pacienta in čim bolj zmanjšati fizični napor osebja pri ravnanju s to opremo.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Oprema za ravnanje s pacienti v reševalnih vozilih - 2. del: Nosila s pomožnim pogonomKrankentransportmittel im Krankenkraftwagen - Teil 2: Kraftunterstützte KrankentrageSpécifications d'équipements pour le transport de patient dans les ambulances routières - Partie 2: Brancard motoriséPatient handling equipment used in road ambulances - Part 2: Power assisted stretcher43.160Vozila za posebne nameneSpecial purpose vehicles11.160First aidICS:Ta slovenski standard je istoveten z:EN 1865-2:2010+A1:2015SIST EN 1865-2:2010+A1:2015en,de01-maj-2015SIST EN 1865-2:2010+A1:2015SLOVENSKI
STANDARDSIST EN 1865-2:20101DGRPHãþD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 1865-2:2010+A1
March 2015 ICS 11.160 Supersedes EN 1865-2:2010English Version
Patient handling equipment used in road ambulances - Part 2: Power assisted stretcher
Spécifications d'équipements pour le transport de patient dans les ambulances routières - Partie 2: Brancard motorisé
Krankentransportmittel im Krankenkraftwagen - Teil 2: Kraftunterstützte Krankentrage This European Standard was approved by CEN on 2 July 2010 and includes Amendment 1 approved by CEN on 20 December 2014.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1865-2:2010+A1:2015 ESIST EN 1865-2:2010+A1:2015
Relationship between this European Standard and the Essential Requirements of EU Directive 93/42/EEC on Medical Devices and of EU Directive 2006/42/EC on Essential Health and Safety Requirements" . 10 Bibliography . 12
width: !(550 ± 6020+−) mm" ;
height: maximum 300 mm from loading holding assembly to unloaded lying part. This height dimension does not apply to stretchers with monoblock undercarriages. If a monoblock is not available, the stretcher shall be constructed such that it is detachable from the undercarriage. Where a stretcher support is used the measurement shall be taken from the top surface of the stretcher support to the lying part of the stretcher. — Undercarriage: length and width of the frame of the undercarriage when located in the ambulance shall not exceed length and width of the stretcher. 4.2.3 Mass The total mass excluding mattress and patient restraints shall be not more than !75 kg". NOTE In all cases the mass should be as low as possible. SIST EN 1865-2:2010+A1:2015
150 mm and 200 mm measured from the top of the stretcher frame to the top of the side rail. b) If longitudinal handles are incorporated they shall be fitted to the ends of the longitudinal frame such that they lock and do not twist when they are stowed or in use. They shall be designed to minimize the risk of injuries to the hands and wrists when being operated or the stretcher is carried at angles. It shall allow the fixation and use of a carrying harness. c) The stretcher shall have a water and scratch resistant paint finish or be manufactured of corrosion resistant material. Both shall be unaffected by disinfectants. d) If intended to be used without un
...