EN 14124:2004
(Main)Inlet valves for flushing cisterns with internal overflow
Inlet valves for flushing cisterns with internal overflow
The purpose of this document is to specify:
- the dimensional, hygiene, tightness, pressure performance, hydraulic, acoustic, mechanical and physico chemical characteristics which inlet valves for flushing cisterns shall comply with;
- the test methods for testing these characteristics;
- marking and presentation.
This document applies exclusively to the valve itself and it does not prejudge compliance with health regulations as the inlet valve is being fitted into the cistern.
This document does not cover valves intended to equip flushing cisterns with external overflow.
This document applies to valves such as float valves limit operating at pressures up to NP 10 (whose operating range is from 0,05 MPa to 1 MPa - 0,5 bar to 10 bar) designed to supply cold water to flushing cisterns for use with WC pans, that are permanently connected to a potable water supply system.
The working range can be extended downwards (< 0,05 MPa - 0,5 bar) down to 0,01 MPa (0,1 bar), in which case the manufacturer's instructions shall indicate this possibility as well as the recommended working range.
Füllventile für Spülkästen mit integriertem Überlauf
Diese Europäische Norm dient der Festlegung von:
¾ Anforderungen an Maße, Hygiene, Dichtheit, Druckbeständigkeit, hydraulischer Eigenschaften, Geräuschverhalten, mechanischer Festigkeit und physikalisch-chemischer Eigenschaften, denen die Füllventile für Spülkästen entsprechen müssen;
¾ Prüfverfahren zum Nachweis dieser Anforderungen;
¾ Anforderung an Kennzeichnung und Darstellung.
Diese Norm gilt ausschließlich für das Füllventil selbst und beinhaltet nicht die Einhaltung von Gesundheits-vorschriften, da das Füllventil in den Spülkasten eingebaut wird.
Füllventile zum Einbau in Spülkästen mit externem Überlauf werden in dieser Norm nicht behandelt.
Diese Norm gilt für Füllventile für einen maximalen Betriebsdruck DN 10 (deren Funktionsbereich von 0,05 MPa bis 1 MPa - von 0,5 bar bis 10 bar - reicht) zur Kaltwasserversorgung von Spülkästen für WC Becken, die ständig an die Trinkwasserinstallation angeschlossen sind.
Füllventile können einen erweiterten Funktionsbereich unterhalb 0,05 MPa (0,5 bar) bis 0,01 MPa (0,1 bar) aufweisen. In diesem Fall muss die Herstelleranweisung diese Möglichkeit sowie den empfohlenen Funktionsbereich angeben.
Diese Norm gilt nicht für Füllventile für andere Anwendungsbereiche, z. B. für den Einbau in Pumpen- und Nachspeisebehälter
Robinet pour remplissage de réservoir de chasse avec trop-plein intérieur
Le présent document a pour objet de fixer :
- les caractéristiques dimensionnelles, d'hygiène, d'étanchéité, de tenue en pression, hydrauliques, acoustiques, mécaniques, physico-chimiques auxquelles doivent répondre les robinets pour réservoir de chasse ;
- la technique des essais ;
- le marquage et la présentation.
Le présent document s'applique exclusivement au robinet lui-même, et ne préjuge pas de la conformité aux réglementations sanitaires du robinet installé dans le réservoir de chasse.
Les robinets destinés à équiper les réservoirs à trop-plein extérieur ne sont pas traités dans le présent document.
Il s'applique aux robinets de remplissage de PN 10, dont la plage de fonctionnement est de 0,05 MPa à 1 MPa (0,5 bar à 10 bar), destinés à l'alimentation en eau froide des réservoirs de chasse équipant les cuvettes de WC raccordés de façon permanente au réseau d'eau potable.
La plage de fonctionnement peut être étendue vers le bas en-dessous de 0,05 MPa (0,5 bar) jusqu'à 0,01 MPa (0,1 bar) ; dans ce cas, la notice du fabricant devra indiquer cette possibilité ainsi que la plage de fonctionnement recommandée.
Inlet valves for flushing cisterns with internal overflow
General Information
- Status
- Published
- Publication Date
- 31-Aug-2004
- Technical Committee
- CEN/TC 164 - Water supply
- Drafting Committee
- CEN/TC 164/WG 8 - Sanitary tapware
- Current Stage
- 9060 - Closure of 2 Year Review Enquiry - Review Enquiry
- Start Date
- 02-Dec-2024
- Completion Date
- 02-Dec-2024
- Directive
- 89/106/EEC - Construction products
Overview
EN 14124:2004 (CEN) specifies requirements and test methods for inlet valves for flushing cisterns with internal overflow. The standard covers the valve itself (not the cistern installation) and applies to devices-typically float-operated inlet valves-designed to supply cold potable water to WC flushing cisterns permanently connected to a potable water system. It excludes valves for cisterns with external overflow and other tank applications.
Key topics and technical requirements
- Scope and limits: Designed for valves operating up to PN 10 (dynamic/static pressure range normally 0.05 MPa to 1 MPa - 0.5–10 bar). Manufacturers may declare a reduced lower working limit down to 0.01 MPa (0.1 bar).
- Materials: Components in contact with potable water must be safe for human consumption (no adverse taste, smell or contamination up to 25 °C). End connections are required to be copper alloy or an equivalent-performance material.
- Design and manufacture: Composition (supply connection, outlets, float/detector), possible water-level adjustment devices, permitted connection orientations (side, back, bottom, top), and restrictions on dismantlable submerged connections.
- Dimensional requirements: Threaded end-connection dimensions are specified (e.g., common sizes and tolerances referenced to EN ISO 228-1).
- Mechanical and hydraulic performance: Tests and limits for tensile strength and torque resistance of end connections, flow rate and filling time, resistance to pressure, reopening behavior, endurance, and susceptibility to water hammer.
- Leaktightness & backflow prevention: Static and dynamic leak tests and mandatory backflow prevention/air inlet characteristics to prevent potable-water contamination (in line with EN 1717 requirements).
- Acoustic characteristics: Noise emission requirements and measurement methods (informative Annex A references EN ISO 3822 series).
- Testing, marking & presentation: Detailed test methods for all characteristics (tensile, torque, backflow, leak, flow, endurance, acoustic) and labelling/marking requirements.
Practical applications and users
- Manufacturers of inlet valves and flushing cistern components use EN 14124:2004 to design, test and certify products for the European market.
- Product test laboratories follow the standard’s test methods for performance verification (leaktightness, flow, endurance, acoustics).
- Plumbing product specifiers, installers and procurement teams reference the standard to ensure valves meet safety, hygiene and performance expectations for WC cisterns connected to potable water.
- Regulatory and compliance personnel use it when assessing conformity to European/national standards for sanitary installations.
Related standards
- EN 1717 - Protection against pollution of potable water (backflow prevention)
- EN ISO 228-1 - Thread dimensions for non-pressure-tight pipe threads
- EN ISO 3822 (parts) - Acoustic measurement methods for water-supply equipment
- EN ISO 5167-1 - Flow measurement by differential devices
Keywords: EN 14124:2004, inlet valves, flushing cisterns, internal overflow, backflow prevention, test methods, potable water, CEN.
Frequently Asked Questions
EN 14124:2004 is a standard published by the European Committee for Standardization (CEN). Its full title is "Inlet valves for flushing cisterns with internal overflow". This standard covers: The purpose of this document is to specify: - the dimensional, hygiene, tightness, pressure performance, hydraulic, acoustic, mechanical and physico chemical characteristics which inlet valves for flushing cisterns shall comply with; - the test methods for testing these characteristics; - marking and presentation. This document applies exclusively to the valve itself and it does not prejudge compliance with health regulations as the inlet valve is being fitted into the cistern. This document does not cover valves intended to equip flushing cisterns with external overflow. This document applies to valves such as float valves limit operating at pressures up to NP 10 (whose operating range is from 0,05 MPa to 1 MPa - 0,5 bar to 10 bar) designed to supply cold water to flushing cisterns for use with WC pans, that are permanently connected to a potable water supply system. The working range can be extended downwards (< 0,05 MPa - 0,5 bar) down to 0,01 MPa (0,1 bar), in which case the manufacturer's instructions shall indicate this possibility as well as the recommended working range.
The purpose of this document is to specify: - the dimensional, hygiene, tightness, pressure performance, hydraulic, acoustic, mechanical and physico chemical characteristics which inlet valves for flushing cisterns shall comply with; - the test methods for testing these characteristics; - marking and presentation. This document applies exclusively to the valve itself and it does not prejudge compliance with health regulations as the inlet valve is being fitted into the cistern. This document does not cover valves intended to equip flushing cisterns with external overflow. This document applies to valves such as float valves limit operating at pressures up to NP 10 (whose operating range is from 0,05 MPa to 1 MPa - 0,5 bar to 10 bar) designed to supply cold water to flushing cisterns for use with WC pans, that are permanently connected to a potable water supply system. The working range can be extended downwards (< 0,05 MPa - 0,5 bar) down to 0,01 MPa (0,1 bar), in which case the manufacturer's instructions shall indicate this possibility as well as the recommended working range.
EN 14124:2004 is classified under the following ICS (International Classification for Standards) categories: 91.140.70 - Sanitary installations. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 14124:2004 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC; Standardization Mandates: M/EXP. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
You can purchase EN 14124:2004 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CEN standards.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Inlet valves for flushing cisterns with internal overflowFüllventile für Spülkästen mit integriertem ÜberlaufRobinet pour remplissage de réservoir de chasse avec trop-plein intérieurInlet valves for flushing cisterns with internal overflow91.140.70Sanitarne napraveSanitary installationsICS:Ta slovenski standard je istoveten z:EN 14124:2004SIST EN 14124:2004en01-oktober-2004SIST EN 14124:2004SLOVENSKI
STANDARD
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 14124September 2004ICS 91.140.70 English versionInlet valves for flushing cisterns with internal overflowRobinet pour remplissage de réservoir de chasse avectrop-plein intérieurFüllventile für Spülkästen mit integriertem ÜberlaufThis European Standard was approved by CEN on 9 July 2004.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2004 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14124:2004: ESIST EN 14124:2004
Test method used to verify the acoustic characteristics.21
testing these characteristics; marking and presentation. This document applies exclusively to the valve itself and it does not prejudge compliance with health regulations as the inlet valve is being fitted into the cistern. This document does not cover valves intended to equip flushing cisterns with external overflow. This document applies to valves such as float valves limit operating at pressures up to NP 10 (whose operating range is from 0,05 MPa to 1 MPa – 0,5 bar to 10 bar) designed to supply cold water to flushing cisterns for use with WC pans, that are permanently connected to a potable water supply system. The working range can be extended downwards (< 0,05 MPa – 0,5 bar) down to 0,01 MPa (0,1 bar), in which case the manufacturer’s instructions shall indicate this possibility as well as the recommended working range.
Range which shall be covered
Optional range This document does not apply to valves used for other applications: pumping tanks, storage tanks, etc. Table 1 — Working conditions for flushing cistern inlet valves
Operating limits Limit recommended for proper functioning (dynamic pressure) Minimum dynamic pressure P ≥ 0,05 MPa (0,5 bar) a 0,1 MPa ≤ P ≤ 0,5 Mpa (1 bar ≤ P ≤ 5 bar) Maximum static pressure P ≤ 1 MPa (10 bar)
a According to
the manufacturer’s indication, the dynamic pressure (opening-closing) can be lowered. SIST EN 14124:2004
In the event of use of a threaded end connection, the dimensions of the end connection shall comply with the specifications in Table 2 below: SIST EN 14124:2004
...