EN 2349-319:2006
(Main)Aerospace series - Requirements and test procedures for relays and contactors - Part 319: Miss test
Aerospace series - Requirements and test procedures for relays and contactors - Part 319: Miss test
This standard specifies a method for the relay miss test to show conformance to the minimum current requirements. It shall be used together with EN 2349-100.
Luft- und Raumfahrt - Anforderungen und Prüfverfahren für Relais und Schaltschütze - Teil 319: Mindeststromprüfung
Diese Norm legt ein Verfahren für die Mindeststromprüfung von Relais fest, um die Mindeststromanforde¬rungen nachzuweisen. Sie ist in Verbindung mit EN 2349-100 anzu¬wenden.
Série aérospatiale - Exigences et méthodes d'essais des relais et contacteurs - Partie 319 : Test de manquer
Aeronavtika - Zahteve in preskusni postopki za releje in kontaktorje - 319. del: Preskus z minimalnim tokom (miss test)
General Information
- Status
- Published
- Publication Date
- 24-Oct-2006
- Withdrawal Date
- 29-Apr-2007
- Technical Committee
- ASD-STAN - Aerospace
- Drafting Committee
- ASD-STAN/D 2 - Electrical
- Current Stage
- 9093 - Decision to confirm - Review Enquiry
- Start Date
- 01-Jun-2017
- Completion Date
- 28-Jan-2026
Relations
- Effective Date
- 28-Jan-2026
Overview
EN 2349-319:2006 - “Aerospace series - Requirements and test procedures for relays and contactors - Part 319: Miss test” is a CEN European standard that specifies a method to perform the relay miss test. Its purpose is to demonstrate conformance to the minimum current requirements for aerospace relays and contactors. This part is intended to be used together with EN 2349-100 (general requirements).
Key topics and requirements
- Scope: Defines a standardized procedure to verify that a relay/contact does not miss operations at low contact currents.
- Mounting method: Device under test shall be wired per EN 2349-100 and placed in a heating cabinet during the test.
- Test conditions:
- Contact load: 300 μA / 5 V d.c.
- Number of operations: 5 000
- Allowed number of misses: 0
- Alarm level during test: 100 Ω (dynamic contact resistance)
- Acceptance criterion: There shall be no missed operations during the specified sequence.
- Normative reference: EN 2349-100 is indispensable for applying this procedure.
Practical applications
- Verification of relay and contactor performance at minimal current levels for aerospace applications.
- Use in qualification testing, production acceptance, and reliability assessments where low-contact-current operation is critical.
- Employed by:
- Aerospace component manufacturers for design verification and production testing.
- Aerospace test laboratories to validate compliance with minimum current requirements.
- Quality assurance and procurement teams to establish supplier compliance.
- Certification and regulatory bodies reviewing component test evidence.
Why it matters (keywords)
EN 2349-319:2006 provides a repeatable miss test procedure to ensure aerospace relays and contactors reliably close and open under minimum current conditions. It helps prevent latent failures in avionics and power distribution systems where low drive currents and contact resistance can cause missed operations.
Related standards
- EN 2349-100 (must be used together) - general requirements for relays and contactors.
- Other parts of the EN 2349 aerospace series and applicable aerospace electrical system standards (refer to national CEN bodies for full list and versions).
This concise test method supports consistent, comparable results across manufacturers and test houses, improving reliability and safety of aerospace electrical components.
Get Certified
Connect with accredited certification bodies for this standard
National Aerospace and Defense Contractors Accreditation Program (NADCAP)
Global cooperative program for special process quality in aerospace.

NSF-ISR
NSF International Strategic Registrations.
Orion Registrar Inc.
US-based certification body for management systems.
Sponsored listings
Frequently Asked Questions
EN 2349-319:2006 is a standard published by the European Committee for Standardization (CEN). Its full title is "Aerospace series - Requirements and test procedures for relays and contactors - Part 319: Miss test". This standard covers: This standard specifies a method for the relay miss test to show conformance to the minimum current requirements. It shall be used together with EN 2349-100.
This standard specifies a method for the relay miss test to show conformance to the minimum current requirements. It shall be used together with EN 2349-100.
EN 2349-319:2006 is classified under the following ICS (International Classification for Standards) categories: 49.060 - Aerospace electric equipment and systems. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 2349-319:2006 has the following relationships with other standards: It is inter standard links to EN 2593-001:2014. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 2349-319:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Aeronavtika - Zahteve in preskusni postopki za releje in kontaktorje - 319. del: Preskus z minimalnim tokom (miss test)Luft- und Raumfahrt - Anforderungen und Prüfverfahren für Relais und Schaltschütze - Teil 319: MindeststromprüfungSérie aérospatiale - Exigences et méthodes d'essais des relais et contacteurs - Partie 319 : Test de manquerAerospace series - Requirements and test procedures for relays and contactors - Part 319: Miss test49.060Aerospace electric equipment and systemsICS:Ta slovenski standard je istoveten z:EN 2349-319:2006SIST EN 2349-319:2009en,de01-maj-2009SIST EN 2349-319:2009SLOVENSKI
STANDARD
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 2349-319October 2006ICS 49.060 English VersionAerospace series - Requirements and test procedures for relaysand contactors - Part 319: Miss testSérie aérospatiale - Exigences et méthodes d'essais desrelais et contacteurs - Partie 319 : Test de manquerLuft- und Raumfahrt - Anforderungen und Prüfverfahren fürRelais und Schaltschütze - Teil 319: MindeststromprüfungThis European Standard was approved by CEN on 19 May 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2006 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 2349-319:2006: ESIST EN 2349-319:2009
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...