FprEN ISO 9308-4
(Main)Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 4: Membrane filtration method for Escherichia coli in water with high levels of background bacteria (ISO/FDIS 9308-4:2026)
- Abstract
This document describes a highly specific method for the enumeration of Escherichia coli (E. coli) in water. The method is based on membrane filtration, subsequent culture at 44 °C on a chromogenic agar medium containing a chromogenic ingredient for the detection of the enzyme ß-glucuronidase, and calculation of the number of target organisms in the sample.
Because of the high specificity of the method, this document is suitable for waters with high levels of background bacteria, such as surface waters including bathing water and wastewater. E. coli strains which do not grow at 44 °C and those that are β-glucuronidase negative, such as E. coli O157, will not be detected as E. coli by this method.
- Status
- Not Published
- Publication Date
- 07-Mar-2027
- Technical Committee
- CEN/TC 230 - Water analysis
- Drafting Committee
- CEN/TC 230 - Water analysis
- Current Stage
- 5020 - Submission to Vote - Formal Approval
- Start Date
- 15-Oct-2026
- Due Date
- 10-Sep-2025
- Completion Date
- 10-Sep-2025
FprEN ISO 9308-4 is a draft CEN/ISO standard for water quality testing that specifies a membrane filtration method for enumerating Escherichia coli (E. coli) in water with high levels of background bacteria. It is intended for laboratories and monitoring bodies that need a highly specific count of thermotolerant, β-D-glucuronidase-positive E. coli in fresh water, surface water, bathing water, wastewater, and, with the appropriate procedure, marine and brackish water.
What does FprEN ISO 9308-4 specify?
FprEN ISO 9308-4 specifies a culture-based method for detecting and counting E. coli in water by membrane filtration, incubation on chromogenic agar, colony counting, and calculation of colony forming units. The document is focused on E. coli only, not on other coliform bacteria.
The method is aimed at waters where background flora would make a less selective method difficult to use. It also notes that strains that do not grow at 44 °C or are β-glucuronidase negative, including E. coli O157, are not counted by this method.
The document is organized into 12 clauses and 3 annexes. Clauses 1 to 3 cover scope, references, and definitions; Clauses 4 to 12 cover principle, media, equipment, sampling, procedure, results, performance, reporting, and quality assurance.
| Annex | What it covers |
|---|---|
| Annex A | Flow diagram of the main steps of the procedures |
| Annex B | Culture media and reagent, including preparation and performance testing |
| Annex C | Performance characteristics of the method |
What are the key requirements of FprEN ISO 9308-4?
FprEN ISO 9308-4 is built around membrane filtration, selective incubation, and counting of characteristic colonies. In practice, the method only works well when the correct procedure, media, incubation conditions, and reporting rules are followed.
Sample handling and suitability
Clause 7 requires sampling, transport, and storage in accordance with ISO 19458. The time between sampling and analysis should be as short as possible and no longer than 24 h, with storage at 5 °C allowed for that period. This matters because E. coli counts can change if samples are held too long or kept too warm.
For brackish water, Clause 8.1 requires Procedure B or a comparison of relative recovery between Procedures A and B using ISO 17994 before Procedure A is used routinely. This is important because salinity can reduce recovery and affect whether the method is suitable for a given matrix.
Membrane filtration and target range
Clause 8.3 requires filtration of appropriate test portions by the membrane filtration method. The test portion should be chosen so that at least 10 and at most 150 target colonies are expected on a filter. If the water is unknown, four-fold dilutions are recommended. This helps the laboratory stay in the quantitative range and avoid undercounting or overcrowding.
The document also notes that turbid samples may need smaller volumes, dilution, or multiple filters. Duplicate plates can improve precision. In practice, this means the analyst may need to adjust the tested volume to the clarity and contamination level of the sample.
Two procedures for different waters
Clause 4 and Clause 8 separate the method into two procedures. Procedure A is for fresh water and uses TBX agar after a short resuscitation step at 36 °C, followed by incubation at 44 °C. Procedure B is for marine and brackish water and uses MMGA for pre-incubation before transfer to TBX and incubation at 44 °C. The pre-incubation step is meant to help stressed cells recover, which matters in environmental waters.
The document allows a double-layer MMGA/TBX arrangement as an alternative under Procedure B. That gives laboratories flexibility in how they set up marine-water analysis while keeping the same selective principle.
Colony recognition and result calculation
Clause 8.5 requires all colonies showing a positive β-D-glucuronidase reaction to be counted as E. coli, with the characteristic colour described as blue or blue-green. The plates should be examined the same day and as soon as possible after incubation ends. This is important because delayed reading can make colony identification less reliable.
Clause 9 requires results to be calculated from the number of typical colonies and the tested volume, and reported as cfu per reference volume such as ml, 100 ml, or l. The method uses all filters that fall within the allowed target-colony range. For low counts or counts above the upper limit, the document points users back to ISO 8199.
Performance verification and quality assurance
Clause 10 requires performance characteristics to be based on interlaboratory studies and gives rules for single-laboratory verification. Where not all colonies are confirmed, the document uses false-positive and false-negative handling based on ISO 13843. This matters for laboratories that need to verify the method in their own setting and document its performance.
Clause 12 requires a quality control system for equipment, reagents, and technique. It also points to Annex B and ISO 11133 for media testing, and to ISO 7704 for membrane filter suitability. Positive controls, negative controls, and blanks are part of the method, so the lab has to prove that the whole system works, not just the media.
Media and equipment details
Annex B gives the compositions and preparation steps for TBX and MMGA, including sterilization, pH adjustment, cooling, pouring, and storage conditions. It also specifies membrane filter suitability testing and the control strains used for productivity, selectivity, and specificity checks. This is the practical part that tells a laboratory how to prepare the media so the chromogenic reaction and recovery are reliable.
What terms does FprEN ISO 9308-4 define?
- Escherichia coli (E. coli) - In this document, E. coli is a member of the Enterobacteriaceae that produces β-D-glucuronidase and can grow at 44 °C in the presence of bile salts.
- β-D-glucuronidase - This is the enzyme detected by the chromogenic reaction; colonies that express it are counted as E. coli.
- TBX - Tryptone bile X-glucuronide agar, the selective chromogenic medium used in the method.
- MMGA - Minerals-modified glutamate agar, used in Procedure B for pre-incubation of marine and brackish water samples.
- cfu - Colony forming units, the unit used to report the concentration of E. coli in the sample.
- Procedure A - The fresh-water procedure using TBX after a short resuscitation step at 36 °C.
- Procedure B - The marine- and brackish-water procedure using MMGA before transfer to TBX.
Who uses FprEN ISO 9308-4?
FprEN ISO 9308-4 is used by microbiology laboratories, water utilities, environmental monitoring bodies, and regulatory laboratories that test water for faecal contamination. It is especially relevant to teams working with surface water, bathing water, wastewater, fresh water, and marine or brackish water.
Quality managers and technical supervisors use it to set up validated test workflows, choose the right medium and procedure, and define reporting practices. Analysts use it for routine membrane filtration, incubation, colony counting, and result expression.
Which standards are used with FprEN ISO 9308-4?
| Standard | Contribution to FprEN ISO 9308-4 |
|---|---|
| ISO 7704 | Performance testing of membrane filters |
| ISO 8199:2018 | General requirements for microbiological examinations, including dilution, counting, and reporting guidance |
| ISO 11133 | Preparation, storage, and performance testing of culture media |
| ISO 19458 | Sampling, transport, and storage of water samples for microbiological analysis |
| ISO 13843:2017 | Performance characteristics, verification, and statistical treatment for quantitative microbiological methods |
| ISO 17994 | Comparison of relative recovery when assessing the suitability of Procedure A for brackish water |
| ISO 9308-2 | Most probable number method for E. coli and coliform bacteria |
| ISO 9308-3 | Miniaturized most probable number method for E. coli in surface and waste water |
What does the FprEN ISO 9308-4 document contain?
The document contains the full workflow from sampling to reporting, including the membrane filtration principle, the two incubation procedures, and the result calculation rules. It also contains the media recipes and preparation steps for TBX and MMGA, plus the membrane filter suitability checks and control-organism criteria in Annex B.
Annex C summarizes the interlaboratory performance work and the statistical characteristics derived from it. Clause 10 also gives formulas for handling confirmed and unconfirmed colonies when calculating performance characteristics, which is useful for method verification and quality assessment.
Annex A gives a flow diagram of the main procedural steps, which helps laboratories implement the method consistently. The bibliography points to related water-quality and microbiology standards, the alternative MPN methods, and background studies used in developing the method.
Relations
- Effective Date
- 12-Feb-2026
Frequently Asked Questions
FprEN ISO 9308-4 is a draft published by the European Committee for Standardization (CEN). Its full title is "Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 4: Membrane filtration method for Escherichia coli in water with high levels of background bacteria (ISO/FDIS 9308-4:2026)". This standard covers: This document describes a highly specific method for the enumeration of Escherichia coli (E. coli) in water. The method is based on membrane filtration, subsequent culture at 44 °C on a chromogenic agar medium containing a chromogenic ingredient for the detection of the enzyme ß-glucuronidase, and calculation of the number of target organisms in the sample. Because of the high specificity of the method, this document is suitable for waters with high levels of background bacteria, such as surface waters including bathing water and wastewater. E. coli strains which do not grow at 44 °C and those that are β-glucuronidase negative, such as E. coli O157, will not be detected as E. coli by this method.
This document describes a highly specific method for the enumeration of Escherichia coli (E. coli) in water. The method is based on membrane filtration, subsequent culture at 44 °C on a chromogenic agar medium containing a chromogenic ingredient for the detection of the enzyme ß-glucuronidase, and calculation of the number of target organisms in the sample. Because of the high specificity of the method, this document is suitable for waters with high levels of background bacteria, such as surface waters including bathing water and wastewater. E. coli strains which do not grow at 44 °C and those that are β-glucuronidase negative, such as E. coli O157, will not be detected as E. coli by this method.
FprEN ISO 9308-4 is classified under the following ICS (International Classification for Standards) categories: 07.100.20 - Microbiology of water. The ICS classification helps identify the subject area and facilitates finding related standards.
FprEN ISO 9308-4 has the following relationships with other standards: It is inter standard links to ISO/FDIS 9308-4. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
FprEN ISO 9308-4 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 Escherichia coli
- 4 Principle
- 5 Culture media and reagents
- 6 Equipment and consumables
- 7 Sampling, transportation and storage of samples
- 8 Procedure
- 8.1 General
- 8.2 Preparation of the sample
- 8.3 Membrane filtration
- 8.4 Incubation
- 8.5 Counting of colonies
- 9 Expression of results
- 10 Performance characteristics
- 11 Test report
- 12 Quality assurance
- Annex A
- Annex B
- Annex C
- Bibliography
Introduction
The presence and extent of faecal pollution is an important factor in assessing the quality of water and the risk to human health from infection. Examination of water samples for the presence of Escherichia coli (E. coli), which normally inhabits the bowel of man and other warm-blooded animals, provides an indication of such pollution.
EXAMPLE 1 In European Union Member States the monitoring of levels of E. coli is mandatory for official bathing waters, as indicated by the Directive 2006/7/EC of the European Parliament and of the Council of 15 February 2006 [9] concerning the management of bathing water quality .
EXAMPLE 2 According to the United States Environmental Protection Agency, states may require the measurement of E. coli to determine whether water quality criteria have been met for fresh water that is designated for primary [10] contact recreation, including swimming and bathing .
As surface waters often contain other bacteria than E. coli, either of environmental origin or through contamination with faeces from animal or human origin, a method with high specificity is essential for the enumeration of E. coli in surface water. The aim of this method is to detect thermotolerant E. coli as these are most representative indicators for recent faecal contamination.
oSIST prEN ISO 9308-4:2026
oSIST prEN ISO 9308-4:2026 DRAFT International Standard ISO/DIS 9308-4:2025(en) Water quality — Enumeration of Escherichia coli and coliform bacteria — Part 4:
Membrane filtration method for Escherichia coli in water with high levels of background bacteria WARNING — In order to safeguard the health of laboratory personnel, it is essential that tests for microbiological analysis are only undertaken in properly equipped laboratories, under the control of a skilled microbiologist, and that great care is taken in the disposal of all incubated materials. Persons using this document should be familiar with good laboratory practice. This document does not purport to address all of the safety aspects, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health practices.
1 Scope
This document describes a highly specific method for the enumeration of Escherichia coli (E. coli) in water. The method is based on membrane filtration followed by culture at 44 °C on chromogenic agar medium containing an ingredient for the detection of the enzyme β-glucuronidase, and calculation of the number of [5,6,13] target organisms in the sample .
Because of the high specificity of the method, this document is suitable for waters with high levels of background bacteria, such as surface waters including bathing water and wastewater provided that they contain little particulate or colloidal matter relative to the E. coli concentration. The method can be used for fresh water and, with an adaptation, for marine water.
E. coli strains which do not grow at 44 °C and those that are β-glucuronidase negative, such as E. coli O157, will not be detected as E. coli by this method.
This method is not applicable to the enumeration and detection of coliform bacteria other than E. coli.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 7704, Water quality — Requirements for the performance testing of membrane filters used for direct enumeration of microorganisms by culture methods ISO 8199:2018, Water quality — General requirements and guidance for microbiological examinations by culture ISO 11133, Microbiology of food, animal feed and water — Preparation, production, storage and performance testing of culture media ISO 19458, Water quality — Sampling for microbiological analysis
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
oSIST prEN ISO 9308-4:2026 ISO/DIS 9308-4:2025(en) ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 Escherichia coli
E. coli member of the Enterobacteriaceae that expresses β-D-glucuronidase and is capable of growing at 44 °C in the presence of bile salts
4 Principle
The detection and enumeration of E. coli consists of the following steps:
- Filtration of test portion(s) of the sample and/or dilutions through a membrane filter, which retains the organisms.
- Depending on the type of sample, two different procedures for the detection and enumeration of E. coli are used:
- Procedure A: detection and enumeration of E. coli in fresh water by placement of the membrane filter on tryptone bile-X-glucuronide (TBX) agar, placing the TBX agar at 36 °C for 4 h to 5 h to resuscitate stressed cells, followed by incubation at 44 °C for 21 h.
- Procedure B: detection and enumeration of E. coli in marine water and brackish water by placement of the membrane filter on minerals-modified glutamate agar (MMGA), placing the MMGA at 36 °C for 4 h to 5 h to resuscitate stressed cells, followed by incubation on TBX at 44 °C for 21 h.
- Counting of β-D-glucuronidase positive colonies (blue or blue green) as E. coli.
- Calculation of the colony forming units (cfu) per millilitre (ml) of the sample from the number of colonies counted.
The flow diagram of the main steps of the procedures is given in Annex A. NOTE 1 Recovery of E. coli from marine water appears to be suboptimal on TBX while limited data is available for brackish water (see https:// standards .iso .org/ iso/ 9308/ -4/ ed -1/ en). Pre-incubation on MMGA enhances resuscitation [11,12] of damaged cells and optimizes recovery .
NOTE 2 The colour of β-D-glucuronidase positive colonies can vary on TBX agar from different manufacturers (see https:// standards .iso .org/ iso/ 9308/ -4/ ed -1/ en): follow the manufacturer’s instructions for the specific colour of β-D- glucuronidase positive colonies.
5 Culture media and reagents
Follow good laboratory practices in accordance with ISO 8199. Use peptone saline solution for dilutions or, alternatively, one of the other diluents presented in ISO 8199. The composition of the culture media (TBX and MMGA) and their preparation are specified in Annex B. For performance testing of the culture media, follow the procedures in accordance with Annex B and ISO 11133.
6 Equipment and consumables
Disposable equipment is an acceptable alternative to reusable items if these have the suitable specifications. The usual microbiological laboratory equipment (see ISO 8199) and, in particular, the following shall be used.
oSIST prEN ISO 9308-4:2026 ISO/DIS 9308-4:2025(en) 6.1 Apparatus for sterilization by steam (autoclave) capable of operating at (121 ± 3) °C, as specified in ISO 8199. In case the procedure for pre-incubation on MMGA (Procedure B) is used, the autoclave shall also be capable of operating at (115 ± 3) °C.
6.2 Disinfected or sterilized forceps, for handling of membrane filters. 6.3 Equipment for membrane filtration, with funnels that can be disinfected or sterilized. 6.4 Incubators, one capable of operating at (36 ± 2) °C and one capable of operating at (44 ± 0,5) °C or, alternatively a cycling temperature incubator programmed to switch from (36 ± 2) °C to (44 ± 0,5) °C. 6.5 Membrane filters, composed of cellulose esters or other suitable material, usually 47 mm or 50 mm in diameter, with filtration characteristics equivalent to a rated nominal pore diameter of 0,45 μm and, preferentially, with grid lines.
6.6 pH meter, with an accuracy of ±0,1 at 20 °C to 25 °C.
6.7 Refrigerator (e.g. for storage of samples or media), capable of operating at (5 ± 3) °C. 6.8 Sterile Petri dishes with vents, with a diameter of an appropriate diameter. 6.9 Sterile pipettes and micropipettes with sterile tips.
6.10 Water bath (optional), capable of operating at 47 °C to 50 °C (if culture medium is prepared from dehydrated media).
7 Sampling, transportation and storage of samples
Take the samples and deliver them to the laboratory in accordance with ISO 19458. Keep the time between sampling and analysis as short as possible in accordance with ISO 19458, and maximally for 24 h. Samples can be kept at 5 °C (6.7) up to 24 h prior to analysis. NOTE The maximum sample storage time of 24 h is above the acceptable maximum sample storage time for E. coli as given in ISO 19458 (which is 18 h). The deviation from ISO 19458 is based on experimental data (see https:// standards .iso .org/ iso/ 9308/ -4/ ed -1/ en).
8 Procedure
8.1 General
Depending on the type of sample, two different procedures for the detection and enumeration of E. coli are used:
- Procedure A: detection and enumeration of E. coli in fresh water.
- Procedure B: detection and enumeration of E. coli in marine water and brackish water. For brackish water with salinity of maximal 6 ppt, data indicated an equally efficient recovery on TBX as fresh water. The amount of data on brackish water is very limited however, and the level of salinity at which recovery becomes significantly inhibited is unknown. For brackish water it is, therefore, required to use Procedure B or test the relative recovery with Procedure A versus Procedure B (following the method described in ISO 17994) to determine the suitability of Procedure A for brackish water prior to implementation of the method.
oSIST prEN ISO 9308-4:2026 ISO/DIS 9308-4:2025(en)
8.2 Preparation of the sample
For preparation and diluting of the sample (6.9), follow the instructions given in ISO 8199:2018, 6.3 and 8.2.1.
8.3 Membrane filtration
Filter appropriate test portions using membrane filtration in accordance with the instructions in ISO 8199:2018, 9.1.4. Appropriate test portions are volumes or dilutions where growth of at least 10 specific colonies and a maximum of 150 target colonies are expected. If the content of the water is unknown, a range of four-fold dilutions is recommended.
NOTE 1 The test-volumes or levels of dilution depend on the presumed level of faecal contamination of the water to 2 5 be tested: “as a guidance, E. coli concentrations generally range between 10 cfu/l and 10 cfu/l in surface water and 6 10 [8] 10 cfu/l to 10 cfu/l in untreated wastewater, but data varies between locations”. NOTE 2 The maximum volume that can be filtered depends on the particulate matter of the sample. Turbid samples will have lower maximum volumes or will need diluting, which will influence the detection level. If samples are too turbid to efficiently reach the desired detection level, the required volume can be filtered over multiple filters. Alternatively, a most probable number method can be used (see ISO 9308-2 and ISO 9308-3). NOTE 3 The use of duplicate plates per volume or dilution can increase the precision of the method. In the case of multiple dilutions, proceed from the most to the least diluted test portion and in the case of multiple volumes from the smallest to the largest volume.
Disinfect the filtration funnels (6.3) prior to the first sample and in between two different samples. Directly prior to filtration, mix the sample well to ensure a uniform distribution of the microorganisms in the sample.
...