Abstract

This document specifies the methodology for applying precision estimates of a test method derived from the processes specified in ISO 4259-1. In particular, it specifies the procedures for setting the property specification limits based upon test method precision where the property is determined using a specific test method, and determines the specification conformance status when there are conflicting results between supplier and receiver. Other applications of this test method precision are briefly described in principle without the associated procedures.
The procedures in this document have been designed specifically for petroleum and petroleum-related products, which are normally homogeneous. However, the procedures described in this document can also be applied to other types of homogeneous products.
This document is not applicable to non-homogenous products.

Status
Published
Publication Date
16-Jun-2026
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
17-Jun-2026
Due Date
17-Jun-2026
Completion Date
17-Jun-2026

Buy Documents

Standard

EN ISO 4259-2:2026

English language (29 pages)
Preview
Preview
e-Library read for
×1 day

EN ISO 4259-2:2026 is a CEN European Standard that adopts ISO 4259-2:2026 without modification. It sets out how to use precision data from test methods to build specification limits and decide whether petroleum and related products meet those limits when test results from a supplier and a recipient do not agree. The document is written for product specifications, laboratory testing, and commercial quality decisions for normally homogeneous products.

What does EN ISO 4259-2:2026 specify?

EN ISO 4259-2:2026 specifies the methodology for applying precision estimates that are derived using ISO 4259-1. It focuses on two practical tasks: setting property specification limits around a test method, and deciding conformance when supplier and recipient results conflict.

The standard is designed for petroleum and petroleum-related products, but it can also be applied to other homogeneous products. It is not applicable to non-homogenous products.

The document is organized into these main clauses and annexes:

PartWhat it covers
Clause 1Scope
Clause 2Normative references
Clause 3Terms and definitions
Clause 4Application and significance of repeatability, r, and reproducibility, R
Clause 5Specifications
Clause 6Assessment of quality conformance to specifications
Clause 7Dispute procedure
Annex AExplanation of formulae given in Clause 4
Annex BDispute resolution for specifications based on a specified degree of criticality

What are the key requirements of EN ISO 4259-2:2026?

Precision data, repeatability and reproducibility

EN ISO 4259-2:2026 requires published test methods to include repeatability and reproducibility values estimated from a statistically designed inter-laboratory programme. Clause 4 uses those values to judge whether repeated results are acceptable and how much confidence can be placed in an average result.

For repeatability, two results from the same test operator and method are acceptable when their difference is within r. If they are not, additional results are taken, suspect results are rejected one by one, and the average of the acceptable results becomes the estimated property value. In practice, this gives a controlled way to handle outliers instead of making a decision from one questionable result.

For reproducibility, Clause 4 applies the same principle across laboratories. If two laboratory results differ by no more than R, their average can be used as the estimate of the property. If they differ by more than R, extra results are taken and the reduced reproducibility approach is used to judge the laboratory averages.

Clause 4 also gives 95 % confidence limits for averages and for single upper or lower limits. That matters because many commercial decisions are made from one or a few measurements, not from the true value itself.

Comparison of two test methods

EN ISO 4259-2:2026 also uses reproducibility to compare two different test methods that claim to measure the same property. Clause 4.4 gives a statistic based on the averages from the two methods and their reproducibility values.

If that statistic is greater than 2, the standard says a constant bias correction statistically improves agreement for that material. This is useful when method comparison or proficiency testing shows that two methods are close, but not yet aligned enough for direct interchange.

Setting specification limits

EN ISO 4259-2:2026 requires specification limits to stay within the scope of the specified test method. Clause 5 says the lower specification limit cannot fall below the lower method scope limit, and the upper specification limit cannot exceed the upper method scope limit.

Clause 5 also links the width of the specification window to test precision. If the limits are too close together for the precision of the method, the result is too uncertain to support a reliable conformance decision. In practice, the standard points the reader toward one of two fixes: widen the limits, or improve or replace the test method.

Checking conformance by supplier and recipient

EN ISO 4259-2:2026 bases conformance decisions on test results that come from methods in statistical control and with no persistent bias. Clause 6 requires in-house Statistical Quality Control (SQC) charts, or equivalent techniques, and evidence of testing proficiency through proficiency testing schemes (PTS) or a certified reference material (CRM).

For a single result, the supplier may treat the product as meeting specification only when the result lies far enough inside the limit, using the confidence limits given in Clause 6. The recipient uses the complementary decision rule for a single batch. In both cases, the 0.59R decision guidance shows how much allowance the standard makes for test variation.

If multiple results are available, Clause 6 uses the average of the acceptable results and the precision rules from Clause 4. That means a buyer or seller should not base a final call on a suspect result when the standard allows a more stable average.

Dispute resolution and criticality

EN ISO 4259-2:2026 gives a structured dispute procedure in Clause 7. The first step is negotiation, then repeat testing on an agreed adjudication sample, then comparison of supplier and recipient averages, and if necessary the involvement of a neutral third-party laboratory.

The clause also sets the decision logic for unresolved disputes, including the use of reduced reproducibility and a grand average when more than one laboratory is involved. This matters in practice because it gives suppliers and recipients a common path when commercial consequences depend on one disputed result.

Annex B provides an alternative dispute procedure for specifications that have a pre-agreed degree of criticality, p_c. It distinguishes critical and non-critical specifications and adjusts the acceptance decision to the agreed risk level.

What terms does EN ISO 4259-2:2026 define?

  • Proficiency testing scheme (PTS) - A programme that periodically checks a laboratory’s capability by statistical comparison of its results on aliquots from a single homogeneous batch.
  • Recipient - The individual or organization that receives or accepts the product delivered by the supplier.
  • Supplier - The individual or organization responsible for the product quality just before the recipient takes over.
  • Repeatability, r - The precision limit used to judge agreement between results obtained under repeatability conditions, usually within one laboratory.
  • Reproducibility, R - The precision limit used to judge agreement between results obtained under reproducibility conditions, usually between different laboratories.
  • Critical specification - In Annex B, a specification with p_c below 0.5, meaning the dispute procedure is set for higher recipient protection.

Who uses EN ISO 4259-2:2026?

EN ISO 4259-2:2026 is used by petroleum and related-product laboratories that report test results for fuels, lubricants, and similar homogeneous products. It is also used by suppliers and recipients when they need to set contract limits, release product, or challenge a result.

Quality managers and technical buyers use it when they want a specification that matches the precision of the test method. Conformity assessment teams, proficiency testing organizers, and third-party dispute laboratories use it to check statistical control, assess bias, and settle disagreements over batch quality.

What changed in EN ISO 4259-2:2026 from the previous edition?

EN ISO 4259-2:2026 supersedes EN ISO 4259-2:2017 and EN ISO 4259-2:2017/A1:2019. The main changes stated in the document are:

  • normative references to ISO 4259-3 and ISO 4259-4 were added;
  • Figures 1, 2 and 3 were modified;
  • former Annex C was deleted because its content is covered by ISO 4259-4.

Which standards are used with EN ISO 4259-2:2026?

  • ISO 4259-1:2026 - Supplies the precision data determination process and the glossary of variables used with this part.
  • ISO 4259-3 - Covers monitoring and verification of published precision data and supports proficiency testing and bias assessment.
  • ISO 4259-4 - Covers statistical control charts used to validate “in statistical control” status for a single laboratory.
  • ISO 4259-5 - Covers statistical assessment of agreement between two different measurement methods that claim to measure the same property, which is the broader method-comparison context referred to in the introduction.

What does the EN ISO 4259-2:2026 document contain?

EN ISO 4259-2:2026 contains the formula-based procedures behind repeatability and reproducibility decisions, plus the confidence-limit calculations used in single-lab and multi-lab cases. It also contains a method for comparing two test methods on the same material and a rule for deciding when a constant bias correction is justified.

The document includes Figure 1 for specification setting, Figure 2 for recipient conformance assessment, and Figure 3 for the dispute flow. Annex A explains the formulae in Clause 4 and includes the normal-distribution critical values in Table A.1. Annex B gives the criticality-based dispute route, and the worked examples in Clauses 6 and 7 show how the steps are applied to a real property case using RON, EN 228, and ISO 5164.

Relations

Effective Date
21-Feb-2024
Effective Date
21-Feb-2024
Effective Date
01-Jul-2026
Effective Date
01-Jul-2026
Effective Date
01-Jul-2026
Effective Date
21-Oct-2026
Effective Date
24-Jun-2026
Effective Date
24-Jun-2026
Effective Date
24-Jun-2026
Effective Date
24-Jun-2026
Effective Date
24-Jun-2026
Effective Date
24-Jun-2026
Effective Date
24-Jun-2026
Effective Date
24-Jun-2026
Effective Date
24-Jun-2026

Buy Documents

Standard

EN ISO 4259-2:2026

English language (29 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

Element Materials Technology

Materials testing and product certification.

UKAS United Kingdom Verified

ABS Group Brazil

ABS Group certification services in Brazil.

CGCRE Brazil Verified

ABS Quality Evaluations Inc.

American Bureau of Shipping quality certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

EN ISO 4259-2:2026 is a standard published by the European Committee for Standardization (CEN). Its full title is "Petroleum and related products - Precision of measurement methods and results - Part 2: Interpretation and application of precision data in relation to methods of test (ISO 4259-2:2026)". This standard covers: This document specifies the methodology for applying precision estimates of a test method derived from the processes specified in ISO 4259-1. In particular, it specifies the procedures for setting the property specification limits based upon test method precision where the property is determined using a specific test method, and determines the specification conformance status when there are conflicting results between supplier and receiver. Other applications of this test method precision are briefly described in principle without the associated procedures. The procedures in this document have been designed specifically for petroleum and petroleum-related products, which are normally homogeneous. However, the procedures described in this document can also be applied to other types of homogeneous products. This document is not applicable to non-homogenous products.

This document specifies the methodology for applying precision estimates of a test method derived from the processes specified in ISO 4259-1. In particular, it specifies the procedures for setting the property specification limits based upon test method precision where the property is determined using a specific test method, and determines the specification conformance status when there are conflicting results between supplier and receiver. Other applications of this test method precision are briefly described in principle without the associated procedures. The procedures in this document have been designed specifically for petroleum and petroleum-related products, which are normally homogeneous. However, the procedures described in this document can also be applied to other types of homogeneous products. This document is not applicable to non-homogenous products.

EN ISO 4259-2:2026 is classified under the following ICS (International Classification for Standards) categories: 75.080 - Petroleum products in general. The ICS classification helps identify the subject area and facilitates finding related standards.

EN ISO 4259-2:2026 has the following relationships with other standards: It is inter standard links to EN ISO 4259-2:2017, EN ISO 4259-2:2017/A1:2019, ISO 4259-3:2020, ISO 4259-4:2021, ISO 4259-1:2026, EN 14214:2026, EN 13924-1:2015, EN 14023:2010, CEN/TS 15293:2011, CEN/TR 15745:2015, EN 16709:2024, EN 13924:2006, EN 590:2025, CEN/TR 15139:2005, EN 589:2018. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN ISO 4259-2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 proficiency testing scheme
  • 3.2 recipient
  • 3.3 supplier
  • 4 Application and significance of repeatability, r, and reproducibility, R
  • 4.1 General
  • 4.2 Repeatability, r
  • 4.3 Reproducibility, R
  • 4.4 Use of reproducibility to determine bias between two different test methods that
  • 5 Specifications
  • 5.1 Aim of specifications
  • 5.2 Construction of specifications limits in relation to scope and precision of the specified
  • 6 Assessment of quality conformance to specifications
  • 6.1 General
  • 6.2 Assessment of quality conformance by the supplier
  • 6.3 Assessment of quality conformance by the recipient
  • 7 Dispute procedure
  • 7.1 Resolve dispute by negotiation
  • 7.2 Use of the test method or procedure in case of dispute
  • 7.3 Dispute resolution procedure
  • 7.4 Dispute unresolved
  • 7.5 Example of a dispute resolution
  • Annex A
  • 1 N 2N  1 N 
  • Annex B
  • Bibliography

Introduction

For the purposes of setting product specifications and checking product conformity against these specifications, standard test methods are usually referenced for specific properties of commercial petroleum and related products. Two or more measurements of the same property of a specific sample by a specific test method, or by different test methods that purport to measure the same property, will not usually give exactly the same result. It is therefore necessary to take proper account of this fact when setting product specifications, assessing if the differences between test results are within statistical expectation, and making specification compliance decisions based on limited test results. By using statistically-based estimates of the precision for a test method, the following can be achieved:

  • an objective measure of the reliability of specification limits,
  • a specification compliance decision,
  • the degree of agreement expected between two or more results obtained in specified circumstances. This document describes the applications of the precision of test methods as derived from ISO 4259-1. It is intended to be used in conjunction with the other parts of ISO 4259 series to provide additional guidance on the application of precision estimates. ISO 4259-3 specifies how to use the precision to assess capability via proficiency testing and ISO 4259-4 specifies how to use this precision to assess the “in statistical control” status and precision capability of a specific laboratory in the execution of a test method. Furthermore, ISO 4259-5 specifies the general approach to the agreement between two different test methods that purport to measure the same property.

ISO 4259-1 and this document encompass both the determination of precision estimates and the application [1] of precision data. The principles within the documents attempt to be aligned with ASTM D6300 regarding [2] the determination of the precision estimates and with ASTM D3244 for the utilization of test data. A glossary of the variables used in this document is included in ISO 4259-1:2026, Annex I.

SIST EN ISO 4259-2:2026

SIST EN ISO 4259-2:2026 International Standard ISO 4259-2:2026(en) Petroleum and related products — Precision of measurement methods and results — Part 2:

Interpretation and application of precision data in relation to methods of test

1 Scope

This document specifies the methodology for applying precision estimates of a test method derived from the processes specified in ISO 4259-1. In particular, it specifies the procedures for setting the property specification limits based upon test method precision where the property is determined using a specific test method, and determines the specification conformance status when there are conflicting results between supplier and receiver. Other applications of this test method precision are briefly described in principle without the associated procedures.

The procedures in this document have been designed specifically for petroleum and petroleum-related products, which are normally homogeneous. However, the procedures described in this document can also be applied to other types of homogeneous products.

This document is not applicable to non-homogenous products.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 4259-1:2026, Petroleum and related products — Precision of measurement methods and results — Part 1:

Determination of precision data in relation to methods of test ISO 4259-3, Petroleum and related products — Precision of measurement methods and results — Part 3:

Monitoring and verification of published precision data in relation to methods of test ISO 4259-4, Petroleum and related products — Precision of measurement methods and results — Part 4: Use of statistical control charts to validate 'in-statistical-control' status for the execution of a standard test method in a single laboratory

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 4259-1 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

SIST EN ISO 4259-2:2026 ISO 4259-2:2026(en)

3.1 proficiency testing scheme

PTS programme designed for the periodic evaluation of participating laboratories’ testing capability of a standard test method through the statistical analysis of their test results obtained on aliquots prepared from a single batch of homogeneous material Note 1 to entry: The frequency of such testing varies according to the programme objective. Each execution of testing involves testing of a single batch of material. Materials typically vary from test to test. Note 2 to entry: This is also commonly referred to as the Interlaboratory Cross Check Program (ILCP).

3.2 recipient

individual or organization who receives or accepts a product delivered by the supplier (3.3)

3.3 supplier

individual or organization responsible for the quality of a product just before it is taken over by the recipient (3.2)

4 Application and significance of repeatability, r, and reproducibility, R

4.1 General

The value of these quantities is estimated from analysis of variance (two-factor with replication) performed on the results obtained in a statistically designed inter-laboratory programme in which different laboratories each test a range of samples. Repeatability and reproducibility values estimated in accordance with ISO 4259-1 shall be included in each published test method. NOTE 1 See Annex A for an account of the statistical reasoning underlying the formulae in Clause 4. NOTE 2 Other equivalent statistical techniques can also be used for these estimations. In 4.2 to 4.4, it is assumed that the result(s) are obtained from a test method that is "in statistical control" and “no statistical evidence of systemic bias” vs industry. For determination of "in statistical control", see ISO 4259-4 and for determination of “no statistical evidence of systemic bias” vs industry, see ISO 4259-3.

4.2 Repeatability, r

4.2.1 General

Most laboratories do not carry out more than one test on each sample for routine quality control purposes except in some circumstances, such as in cases of dispute or if the test operator wishes to confirm that the technique used is satisfactory. In such circumstances, when multiple results are obtained, it is useful to check the consistency of repeated results against the repeatability of the method. The appropriate procedure is outlined in 4.2.2. It is also useful to know what degree of confidence can be placed on the average results; see 4.2.3 for the method of determining this.

4.2.2 Acceptability of results

When only two results are obtained under repeatability conditions and their difference is less than or equal to r, the test operator can consider their work as being under control and may take the average of the two results as the estimated value of the property being tested.

If the two results differ by more than r, both shall be considered as suspect and at least three more results obtained. Including the first two, the difference between the most divergent result and the average of the

SIST EN ISO 4259-2:2026 ISO 4259-2:2026(en) remainder shall then be calculated and this difference compared with a new value, r , instead of r, given in

Formula (1):

k rr�� � (1)

21k

where k is the total number of results obtained.

If the difference is less than or equal to r , all the results shall be accepted. If the difference exceeds r , 1 1 the most divergent result shall be rejected and the procedure specified in this subclause repeated until an acceptable set of results is obtained.

The average of the acceptable results shall be taken as the estimated value of the property. However, if two or more results from a total of not more than 20 have been rejected, the operating procedure and the apparatus shall be checked and a new series of tests made.

4.2.3 Confidence limits calculations using results collected under repeatability conditions

When a single test operator, who is working within the precision limits of the method, obtains a series of k results under repeatability conditions, giving an average, X , and the results meet the repeatability requirement in 4.2.2, it can be assumed with 95 % confidence that the true value, μ, of the characteristic lies within the following limits, given in Formula (2):

R R

X   X  (2)

 22   Where R is defined in Formula (3):

 1

R  1 (3) Rr

k

When k = 1, uses the single test result as the value for the X term in Formula (4):

R R X   X  (4)

 22   where R is the published test method reproducibility as discussed in 4.3. Similarly, for the single limit situation, when only one limit is fixed (upper or lower), it can be assumed with 95 % confidence that the true value, μ, of the characteristic is limited as follows for an upper limit Formula (5):

 XR05, 9 (5)

Or lower limit in Formula (6)  XR05, 9 (6)

0,84 The factor 0,59 is the ratio , where 0,84 is derived from Annex A.

When r is much smaller than R, little improvement in the precision of the average is obtained by carrying out multiple testing under repeatability conditions.

SIST EN ISO 4259-2:2026 ISO 4259-2:2026(en)

4.3 Reproducibility, R

4.3.1 Acceptability of results

The procedure specified in this subclause is intended for judging the acceptability, with respect to the reproducibility of the test method, of results obtained by different laboratories in normal, day-to-day operations and transactions. In cases of dispute between a supplier and a recipient, the procedure specified in Clauses 5 to 7 shall be adopted.

When single results are obtained in two laboratories and their difference is less than or equal to R, the two results shall be considered as acceptable, and used to calculate the average X . The average X , rather than either single result separately, shall be used as the estimated value of the tested property. The true value, μ, of the characteristic is contained within the following limits with a 95 % confidence:

 RR   XX   (7)

Similarly, for the single limit situation, when only one limit is fixed (upper or lower), the true value, μ, of the characteristic is contained with the following limits with a 95 % confidence. For an upper limit, see Formula (8):

 XR04, 2 (8)

or lower limit, see Formula (9):

 XR04, 2 (9)

05, 9 The factor 0,42 is the ratio of as it is an average of two results.

If the two results differ by more than R, both shall be considered as suspect. Each laboratory shall then obtain at least three other acceptable results (see 4.2.2).

In this case, the difference between the averages of all acceptable results of each laboratory shall be judged for conformity using a new value, R , instead of R, as given by Formula (10):

1 1

R  1 (10) Rr  

2 2 kk  12 where R is the reproducibility of the method; r is the repeatability of the method; k is the number of results of the first laboratory;

k is the number of results of the second laboratory.

If the difference between the averages is less than or equal to R , then these averages are acceptable and

their overall average shall be considered as the estimated value of the tested property. If the difference between the averages is greater than R , and there is a dispute on the specification conformance of the

tested property, then the procedure specified in Clause 7 shall be adopted. If circumstances arise in which there are more than two laboratories, each supplying one or more acceptable results, the difference between the most divergent laboratory average and the average of the remaining N laboratory averages shall be compared to R :

SIST EN ISO 4259-2:2026 ISO 4259-2:2026(en) where 2 2 RR 1 4 R  (11)

22N

r 11 1

RR N  (12)

N kk k

12 N R is given in Formula (3), and corresponds to the most divergent laboratory average.

If this difference is equal to or less than R in absolute value, all results shall be regarded as acceptable and

their average taken as the estimated value of the property.

If the difference is greater than R , the most divergent laboratory average shall be rejected and the

comparison using Formulae (11) and (12) repeated until an acceptable set of laboratory averages is obtained. The average of these laboratory averages shall be taken as the estimated value of the property. However, if two or more laboratory averages from a total of not more than 20 have been rejected, the operating procedure and the apparatus shall be checked and a new series of tests made.

4.3.2 Confidence limits calculations using results collected under reproducibility conditions

When N laboratories obtain one or more results under conditions of repeatability and reproducibility, giving an average of laboratory averages X , the true value μ of the characteristic is contained within the following limits with 95 % confidence:

R R

XX (13) 22N N Similarly, for the single limit situation, when only one limit is fixed (upper or lower), the true value μ of the characteristic is contained with the following limits with 95 % confidence for an upper limit in Formula (14):

 R 

 X 05, 9 (14)

N

Or lower limit in Formula (15)  R 

 X 05, 9 (15)

N

4.4 Use of reproducibility to determine bias between two different test methods that

purport to measure the same property

4.4.1 General

For the situation where two different test methods purport to measure the same property, the reproducibility estimates (R) from the respective test methods shall be used in conjunction with the averages obtained from multiple laboratories for the same material to determine if a bias correction can be applied to improve statistically the agreement between the two methods for that material. For example, results collected through proficiency testing schemes (PTS) for different test methods using the same sample can be analysed in this fashion.

NOTE Discussion on methodology for this type of assessment for the simultaneous analysis of multiple materials/ property levels that span the intersecting scope of two different test methods is beyond the scope of this document. [3] Interested readers are encouraged to consult ISO 4259-5 for further information on the subject.

SIST EN ISO 4259-2:2026 ISO 4259-2:2026(en)

4.4.2 Process

Assume that test method A and test method B are test methods that purport to measure property C. Calculate the following statistic:

YY AB Z  (16)

R R A B

7,,683L 7 683L A B where Y is the average from L results for property C for a material using test method A, where each A A result is a single result obtained under reproducibility conditions; L is the total number of laboratories (results) for test method A and should be > 20; A R is the reproducibility of test method A; A Y is the average from L results for property C for a material using test method B on the same B B material tested by test method A, where each result is a single result obtained under reproducibility conditions; L is the total number of laboratories (results) for test method B, and should be > 20; B R is the reproducibility of test method B.

B If Z > 2, it shall be concluded, with 95 % confidence, that a constant bias correction statistically improves the degree of agreement between test method A and test method B for property C for this material.

5 Specifications

5.1 Aim of specifications

The purpose of a specification is to specify an acceptable limit or limits to the true value, μ, of the property as determined by a specified test method. In practice, however, this true value can never be established exactly since the results obtained by applying the specified test method in a single or multiple laboratories can show acceptable scattering as specified by the repeatability and reproducibility. There is, therefore, always some uncertainty as to the true value of the tested property determined from a finite number of test results. Petroleum product compliance with specifications is assessed in accordance with Clauses 6 and 7. By prior agreement, a supplier and recipient may use the alternative procedures described in Annex B. WARNING — It is important that the test method specified for the determination of the property governed by the specification limit(s) is sufficiently precise to reliably determine whether or not the product meets the specifications.

5.2 Construction of specifications limits in relation to scope and precision of the specified

test method The specification limits shall not be outside the method scope limits as determined in ISO 4259-1. The lower specification limit shall not be less than the lower scope limit of the test method, and the upper specification limit shall not be greater than the upper scope limit of the test method (as specified in ISO 4259-1:2026, 6.5).

In addition, the distance between lower and upper specification limit shall also satisfy the following condition: upper specification limit minus lower specification limit shall not be less than the quantity 2R evaluated at lower method scope limit plus 2R evaluated at upper method scope limit. See Figure 1 for an illustration of this concept.

SIST EN ISO 4259-2:2026 ISO 4259-2:2026(en) Usually, specifications deal with limits for the values of the properties. To avoid uncertainty, such limits are normally expressed as “not less than” or “not greater than”. Limits are of two types:

  • a double limit, upper and lower, for example viscosity not less than 5 mm /s and not greater than

...