EN ISO 11296-3:2011
(Main)Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Part 3: Lining with close-fit pipes (ISO 11296-3:2009+Cor 1:2011)
Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Part 3: Lining with close-fit pipes (ISO 11296-3:2009+Cor 1:2011)
ISO 11296-3:2009, in conjunction with ISO 11296-1, specifies requirements and test methods for close-fit lining systems intended to be used for the renovation of non-pressure drainage and sewerage networks.
It applies to pipes and fittings made of polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC‑U). It is applicable to the plastic lining system only.
Kunststoff-Rohrleitungssysteme für die Renovierung von erdverlegten drucklosen Entwässerungsnetzen (Freispiegelleitungen) - Teil 3: Close-Fit-Lining (ISO 11296-3:2009+Cor 1:2011)
Dieser Teil der ISO 11296 legt in Verbindung mit ISO 11296-1 die Anforderungen und Prüfverfahren für Close-Fit-Lining-Systeme fest, die bei der Renovierung druckloser Entwässerungsnetze (Freispiegelleitungen) verwendet werden.
Er gilt für Rohre und Formstücke, die aus Polyethylen (PE) oder weichmacherfreiem Polyvinylchlorid (PVC-U) hergestellt werden. Sie gilt nur für Kunststoff-Lining-Systeme. Sie legt keine Anforderungen an die be-stehende Rohrleitung fest.
Systèmes de canalisations en plastique pour la rénovation des réseaux de branchements et de collecteurs d'assainissement enterrés sans pression - Partie 3: Tubage par tuyau continu sans espace annulaire (ISO 11296-3:2009+Cor 1:2011)
L'ISO 11296-3:2009, conjointement avec l'ISO 11296-1, spécifie les exigences et les méthodes d'essai pour les systèmes de tubage par tuyau continu sans espace annulaire, destinés à être utilisés pour la rénovation des réseaux d'assainissement enterrés sans pression.
Elle s'applique aux tuyaux et aux raccords en polyéthylène (PE) ou en poly(chlorure de vinyle) non plastifié (PVC‑U). Elle s'applique uniquement au système de rénovation en plastique.
Cevni sistemi iz polimernih materialov za obnovo podzemnih omrežij za odvodnjavanje in kanalizacijo za obratovanje brez tlaka (vodi s prosto gladino) - 3. del: Oblaganje s tesno prilagodljivimi cevmi (ISO 11296-3:2009+Cor 1:2011)
Ta del ISO 11296 v povezavi z ISO 11296-1 določa zahteve in preskusne metode za tesno prilagodljive sisteme za oblaganje, namenjene uporabi za obnovo omrežij za odvodnjavanje in kanalizacijo za obratovanje brez tlaka.
Velja za cevi in fitinge iz polietilena (PE) ali nemehčanega polivinilklorida (PVC-U). Velja samo za polimerni sistem oblaganja. Ne velja za zahteve za obstoječe cevovode.
General Information
- Status
- Withdrawn
- Publication Date
- 10-May-2011
- Withdrawal Date
- 20-Jan-2026
- Technical Committee
- CEN/TC 155 - Plastics piping systems and ducting systems
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 29-Aug-2018
- Completion Date
- 28-Jan-2026
Relations
- Effective Date
- 08-Jun-2022
- Effective Date
- 25-Nov-2015
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
Get Certified
Connect with accredited certification bodies for this standard

ICC Evaluation Service
Nonprofit organization that performs technical evaluations of building products.

Aboma Certification B.V.
Specialized in construction, metal, and transport sectors.
BBA (British Board of Agrément)
UK construction product certification.
Sponsored listings
Frequently Asked Questions
EN ISO 11296-3:2011 is a standard published by the European Committee for Standardization (CEN). Its full title is "Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Part 3: Lining with close-fit pipes (ISO 11296-3:2009+Cor 1:2011)". This standard covers: ISO 11296-3:2009, in conjunction with ISO 11296-1, specifies requirements and test methods for close-fit lining systems intended to be used for the renovation of non-pressure drainage and sewerage networks. It applies to pipes and fittings made of polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC‑U). It is applicable to the plastic lining system only.
ISO 11296-3:2009, in conjunction with ISO 11296-1, specifies requirements and test methods for close-fit lining systems intended to be used for the renovation of non-pressure drainage and sewerage networks. It applies to pipes and fittings made of polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC‑U). It is applicable to the plastic lining system only.
EN ISO 11296-3:2011 is classified under the following ICS (International Classification for Standards) categories: 23.040.20 - Plastics pipes; 23.040.45 - Plastics fittings; 91.140.80 - Drainage systems; 93.030 - External sewage systems. The ICS classification helps identify the subject area and facilitates finding related standards.
EN ISO 11296-3:2011 has the following relationships with other standards: It is inter standard links to EN 13566-3:2002, EN ISO 11296-3:2018, prEN 15512, EN 4652-420:2017, EN 13476-3:2007+A1:2009, ENV 12052:1997, EN ISO 15614-1:2017, EN ISO 14405-1:2016, EN 4611-007:2012. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN ISO 11296-3:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-2011
1DGRPHãþD
SIST EN 13566-3:2003
Cevni sistemi iz polimernih materialov za obnovo podzemnih omrežij za
odvodnjavanje in kanalizacijo za obratovanje brez tlaka (vodi s prosto gladino) - 3.
del: Oblaganje s tesno prilagodljivimi cevmi (ISO 11296-3:2009+Cor 1:2011)
Plastics piping systems for renovation of underground non-pressure drainage and
sewerage networks - Part 3: Lining with close-fit pipes (ISO 11296-3:2009+Cor 1:2011)
Kunststoff-Rohrleitungssysteme für die Renovierung von erdverlegten drucklosen
Entwässerungsnetzen (Freispiegelleitungen) - Teil 3: Close-Fit-Lining (ISO 11296-
3:2009+Cor 1:2011)
Systèmes de canalisations en matières plastiques pour la rénovation des réseaux
d'assainissement gravitaires enterrés - Partie 3: Tubage par tuyau continu sans espace
annulaire (ISO 11296-3:2009+Cor 1:2011)
Ta slovenski standard je istoveten z: EN ISO 11296-3:2011
ICS:
23.040.20 Cevi iz polimernih materialov Plastics pipes
93.030 Zunanji sistemi za odpadno External sewage systems
vodo
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN ISO 11296-3
NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2011
ICS 23.040.20; 23.040.45; 93.030; 91.140.80 Supersedes EN 13566-3:2002
English Version
Plastics piping systems for renovation of underground non-
pressure drainage and sewerage networks - Part 3: Lining with
close-fit pipes (ISO 11296-3:2009/Cor 1:2011)
Systèmes de canalisations en plastique pour la rénovation Kunststoff-Rohrleitungssysteme für die Renovierung von
des réseaux d'assainissement enterrés sans pression - erdverlegten drucklosen Entwässerungsnetzen
Partie 3: Tubage par tuyau continu sans espace annulaire (Freispiegelleitungen) - Teil 3: Close-Fit-Lining (ISO 11296-
(ISO 11296-3:2009/Cor 1:2011) 3:2009/Cor 1:2011)
This European Standard was approved by CEN on 8 April 2011.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2011 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 11296-3:2011: E
worldwide for CEN national Members.
Contents Page
Foreword .3
Foreword
The text of ISO 11296-3:2009/Cor 1:2011 has been prepared by Technical Committee ISO/TC 138 “Plastics
pipes, fittings and valves for the transport of fluids” of the International Organization for Standardization (ISO)
and has been taken over as EN ISO 11296-3:2011 by Technical Committee CEN/TC 155 “Plastics piping
systems and ducting systems” the secretariat of which is held by NEN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by November 2011, and conflicting national standards shall be withdrawn
at the latest by November 2011.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 13566-3:2002.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
Endorsement notice
The text of ISO 11296-3:2009/Cor 1:2011 has been approved by CEN as a EN ISO 11296-3:2011 without any
modification.
INTERNATIONAL ISO
STANDARD 11296-3
First edition
2009-11-01
Plastics piping systems for renovation
of underground non-pressure drainage
and sewerage networks —
Part 3:
Lining with close-fit pipes
Systèmes de canalisations en matières plastiques pour la rénovation
des réseaux d'assainissement gravitaires enterrés —
Partie 3: Tubage par tuyau continu sans espace annulaire
Reference number
ISO 11296-3:2009(E)
©
ISO 2009
ISO 11296-3:2009(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2009
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2009 – All rights reserved
ISO 11296-3:2009(E)
Contents Page
Foreword .iv
Introduction.v
1 Scope.1
2 Normative references.1
3 Terms and definitions .2
4 Symbols and abbreviated terms .2
5 Pipes at the “M” stage .2
5.1 Materials .2
5.2 General characteristics.3
5.3 Material characteristics.3
5.4 Geometric characteristics .4
5.5 Mechanical characteristics.4
5.6 Physical characteristics.4
5.7 Jointing.5
5.8 Marking.5
6 Fittings.5
7 Ancillary components.5
8 Fitness for purpose of the installed lining system at the “I” stage .6
8.1 Materials .6
8.2 General characteristics.6
8.3 Material characteristics.6
8.4 Geometric characteristics .6
8.5 Mechanical characteristics.8
8.6 Physical characteristics.8
8.7 Additional characteristics.8
8.8 Sampling.8
9 Installation practice.9
9.1 Preparatory work .9
9.2 Storage, handling and transport of pipes and fittings .9
9.3 Equipment .9
9.4 Installation.10
9.5 Process-related inspection and testing .10
9.6 Lining termination .11
9.7 Reconnection to existing manholes and laterals.11
9.8 Final inspection and testing.11
Annex A (normative) Factory folded heat reverted polyethylene (PE) pipe — Determination of
memory ability .12
Annex B (normative) Folded polyethylene (PE) pipe — Determination of resistance to
circumferential tensile stress at constant temperature .14
Bibliography.19
ISO 11296-3:2009(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 11296-3 was prepared by Technical Committee ISO/TC 138, Plastics pipes, fittings and valves for the
transport of fluids.
ISO 11296 consists of the following parts, under the general title Plastics piping systems for renovation of
underground non-pressure drainage and sewerage networks:
⎯ Part 1: General
⎯ Part 3: Lining with close-fit pipes
⎯ Part 4: Lining with cured-in-place pipes
Lining with continuous pipes is to form the subject of a part 2, lining with discrete pipes is to form the subject
of a part 5 and lining with spirally-wound pipes is to form the subject of a part 7.
iv © ISO 2009 – All rights reserved
ISO 11296-3:2009(E)
Introduction
The System Standard, of which this is part 3, specifies the requirements for plastics piping systems of various
materials used for the renovation of existing pipelines in a specified application area. System Standards for
renovation specify procedures for the following applications:
⎯ plastics piping systems for renovation of underground non-pressure drainage and sewerage networks
(this application);
⎯ plastics piping systems for renovation of underground drainage and sewerage networks under pressure;
⎯ plastics piping systems for renovation of underground water supply networks;
⎯ plastics piping systems for renovation of underground gas supply networks.
These System Standards are distinguished from those for conventionally installed plastics piping systems
because they set requirements for certain characteristics in the as-installed condition, after site processing.
This is in addition to specifying requirements for plastics piping system components, as manufactured.
Each of the System Standards comprises a part 1 (general) and all applicable renovation technique family-
related parts from the following:
⎯ part 2: lining with continuous pipes;
⎯ part 3: lining with close-fit pipes;
⎯ part 4: lining with cured-in-place pipes;
⎯ part 5: lining with discrete pipes;
⎯ part 7: lining with spirally-wound pipes.
The requirements for any given renovation technique family are given in part 1, applied in conjunction with the
other relevant part. For example, parts 1 and 2 specify the requirements relating to lining with continuous
pipes. For complementary information, see ISO 11295. Not all technique families are applicable to every area
of application and this is reflected in the part numbers included in each System Standard.
A consistent structure of clause headings has been adopted for all parts to facilitate direct comparisons across
renovation technique families.
Figure 1 gives the common structure and the relationship between ISO 11296 and the System Standards for
other application areas.
ISO 11296-3:2009(E)
Figure 1 — Format of the renovation System Standards
vi © ISO 2009 – All rights reserved
INTERNATIONAL STANDARD ISO 11296-3:2009(E)
Plastics piping systems for renovation of underground
non-pressure drainage and sewerage networks —
Part 3:
Lining with close-fit pipes
1 Scope
This part of ISO 11296, in conjunction with ISO 11296-1, specifies requirements and test methods for close-fit
lining systems intended to be used for the renovation of non-pressure drainage and sewerage networks.
It applies to pipes and fittings made of polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC-U). It is
applicable to the plastic lining system only. It is not applicable to the requirements for the existing pipeline.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 527-2, Plastics — Determination of tensile properties — Part 2: Test conditions for moulding and
extrusion plastics
ISO 899-1:2003, Plastics — Determination of creep behaviour — Part 1: Tensile creep
ISO 2507-1, Thermoplastics pipes and fittings – Vicat softening temperature — Part 1: General test method
ISO 3126, Plastics piping systems — Plastics components — Determination of dimensions
ISO 4435, Plastics piping systems for non-pressure underground drainage and sewerage — Unplasticized
poly(vinyl chloride) (PVC-U)
ISO 6259-1, Thermoplastics pipes — Determination of tensile properties — Part 1: General test method
ISO 8772:2006, Plastics piping systems for non-pressure underground drainage and sewerage —
Polyethylene (PE)
ISO 9852, Unplasticized poly(vinyl chloride) (PVC-U) pipes — Dichloromethane resistance at specified
temperature (DCMT) — Test method
ISO 9967:2007, Thermoplastics pipes — Determination of creep ratio
ISO 9969, Thermoplastics pipes — Determination of ring stiffness
ISO 11296-3:2009(E)
1)
ISO 11296-1:— , Plastics piping systems for renovation of underground non-pressure drainage and
sewerage networks — Part 1: General
ISO 12176-1, Plastics pipes and fittings — Equipment for fusion jointing polyethylene systems — Part 1: Butt
fusion
ISO 13953, Polyethylene (PE) pipes and fittings — Determination of the tensile strength and failure mode of
test pieces from a butt-fused joint
ISO 18373-1:2007, Rigid PVC pipes — Differential scanning calorimetry (DSC) method — Part 1:
Measurement of the processing temperature
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 11296-1 and the following apply.
3.1
close fit
location of the outside of the installed liner relative to the inside of the existing pipeline, which may either be
an interference fit or include a small annular gap resulting from shrinkage and tolerances only
3.2
close-fit pipe
continuous lining pipe of thermoplastic material reshaped or otherwise expanded after insertion to achieve a
close fit to the existing pipeline
3.3
melt mass-flow rate
value relating the viscosity of the molten material at a specified temperature and rate of shear
4 Symbols and abbreviated terms
For the purposes of this document, the symbols and abbreviated terms given in ISO 11296-1 and the following
apply.
d original circular outside diameter of the pipe (before processing for insertion)
manuf
e maximum mean wall thickness
m, max
MFR melt mass-flow rate
OIT oxidation induction time
5 Pipes at the “M” stage
5.1 Materials
5.1.1 General
The material shall be either polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC-U), to which are
added those additives needed to facilitate the manufacture and/or installation of pipes conforming to this part
of ISO 11296.
1) To be published.
2 © ISO 2009 – All rights reserved
ISO 11296-3:2009(E)
5.1.2 Distinction between PVC-U types
PVC-U materials used for liner pipes may have PVC content less than the minimum of 80 %, and/or Vicat
softening temperature less than the 79 °C specified by ISO 4435. For the purposes of this part of ISO 11296,
distinction shall be made between PVC-U conforming to ISO 4435 (designated standard PVC-U) and PVC-U
modified for lining applications.
NOTE This distinction is reflected in the requirements given in Table 4 and Table 11.
5.1.3 Virgin material
Virgin material, as defined in ISO 11296-1, may be used without limitations. Fusion compatibility of PE pipes
shall conform to ISO 8772:2006, 4.6.
5.1.4 Reprocessable material and recyclable material
5.1.4.1 Reprocessable material
Own reprocessable material may be used, provided that it is derived from the same compound used for the
relevant production. External reprocessable material shall not be used.
5.1.4.2 Recyclable material
Recyclable material shall not be used.
5.2 General characteristics
When viewed without magnification the internal and external surfaces of the pipe shall be smooth, clean and
free from scoring, cavities and other defects, which would prevent conformity to this part of ISO 11296.
5.3 Material characteristics
When tested in accordance with the methods given in Table 1 or Table 2, as applicable, the material from
which the pipes are made shall conform to the requirements given in the relevant table.
Table 1 — Material characteristics of PE pipes
Test parameter
Characteristic Requirement Test method
Parameter Value
Density ISO 8772
Longitudinal tensile stress at > 15 MPa Speed of testing
yield point for e u 12 mm (100 ± 10) mm/min
e > 12 mm (25 ± 2,5) mm/min
Elongation at break
> 350 %
ISO 6259-1
Test piece shape Specimen type 1B in
and initial gauge accordance with
length ISO 527-2
Thermal stability (OIT)
Melt mass-flow rate
ISO 8772
Resistance to internal pressure
(long-term behaviour)
Resistance to circumferential No failure during the
Annex B
a
tensile stress test period
a
Applies to folded pipes only, see Annex B.
ISO 11296-3:2009(E)
Table 2 — Material characteristics of PVC-U pipes
Test parameters
Characteristic Requirement Test method
Parameter Value
a b
E-modulus (tensile) Speed of testing
Declared value , but (5 ± 0,5) mm/min
Test piece shape and ISO 527-2
not less than 1 200 MPa
Specimen type 1B
initial gauge length
a
Longitudinal tensile Speed of testing
Declared value , but not (5 ± 0,5) mm/min
strength
less than 20 MPa
ISO 6259-1
a
Elongation at break Test piece shape and Specimen type 1B in
Declared value , but not
initial gauge length accordance with
less than 70 %
ISO 527-2
Impact strength ISO 4435
a
Some PVC-U close-fit pipe products have declared values considerably higher than the minima specified.
b
The declared value of E-modulus determines the relationship between ring stiffness and SDR (see 8.4 and 8.5).
5.4 Geometric characteristics
The pipe diameter, wall thickness and shape in the “M” stage depend on the specific close-fit lining technique.
“M” stage dimensions needed to obtain specified “I” stage dimensions (see 8.4) shall be declared, with their
tolerances, by the manufacturer.
NOTE In the case of factory-folded pipes, v
...