EN ISO 16646:2025
(Main)Fusion installations - Criteria for the design and operation of confinement and ventilation systems of tritium fusion facilities and fusion fuel handling facilities (ISO 16646:2024)
Fusion installations - Criteria for the design and operation of confinement and ventilation systems of tritium fusion facilities and fusion fuel handling facilities (ISO 16646:2024)
This document specifies the applicable requirements related to the design and the operation of confinement and ventilation systems for fusion facilities for tritium fuels and tritium fuel handling facilities specific for fusion applications for peaceful purposes using high tritium inventories, as well as for their specialized buildings such as hot cells, examination laboratories, emergency management centres, radioactive waste treatment and storage facilities.
In most countries, a tritium quantity is declared as high for tritium inventories higher than a range of 10 g to 100 g. In the tritium fusion facilities in the scope of this document, the tritium inventory is deemed to be higher than this range for the whole site.
This document applies especially to confinement and ventilation systems that ensure the safety function of nuclear facilities involved in nuclear fusion with the goal to protect the workers, the public and the environment from the dissemination of radioactive contamination originating from the operation of these installations, and in particular from airborne tritium contamination with adequate confinement systems.
Fusionsanlagen - Kriterien für die Auslegung und den Betrieb von Einschluss- und Lüftungssystemen von Tritiumfusionsanlagen und Anlagen zur Handhabung von Fusionsbrennstoff (ISO 16646:2024)
Installations de fusion - Critères pour la conception et l'exploitation des systèmes de confinement et de ventilation des installations de fusion avec tritium et des installations de traitement des combustibles de fusion (ISO 16646:2024)
Fuzijske naprave - Merila za načrtovanje in delovanje zadrževalnih in prezračevalnih sistemov v objektih za fuzijo tritija in objektih za ravnanje s fuzijskim gorivom (ISO 16646:2024)
General Information
- Status
- Published
- Publication Date
- 23-Sep-2025
- Current Stage
- 6060 - Definitive text made available (DAV) - Publishing
- Start Date
- 24-Sep-2025
- Due Date
- 29-Jul-2027
- Completion Date
- 24-Sep-2025
Overview
EN ISO 16646:2025 (ISO 16646:2024) provides criteria for the design and operation of confinement and ventilation systems in tritium fusion facilities and fusion fuel handling facilities. It targets installations with high tritium inventories (sites with tritium quantities greater than typical 10 g–100 g ranges) and covers specialized buildings such as hot cells, examination laboratories, emergency management centres, and radioactive waste treatment and storage facilities. The standard’s principal aim is to ensure radiation protection by preventing dissemination of airborne tritium contamination and protecting workers, the public and the environment.
Key Topics and Requirements
- Confinement architecture: Definitions and roles of first and secondary confinement systems, static containment barriers, and isolation functions specific to fusion installations.
- Ventilation system design: Requirements for dynamic confinement, negative pressure strategies, airflows between zones, air exchange optimization, duct layout, pressure-drop calculations and ventilation diagram development.
- Confinement classification: Procedures to classify areas into potentially contaminated zones and assign safety functions to ventilation and containment systems.
- Filtration and detritiation: Specification of HEPA filtration, air detritiation systems and other gas-trapping devices to control airborne tritium.
- Risk assessment and safety classification: Preliminary analysis, risk evaluation, and assignment of safety classes for systems and components.
- Special hazards management: Controls for combustible gases, cryogenic liquid/gas risks, ambient condition management, and ventilation requirements for control rooms and safety-classified components.
- Tritium compatibility: Considerations for materials and systems exposed to tritium and fusion-specific loads.
Applications and Who Uses This Standard
EN ISO 16646 is intended for professionals and organizations involved in the design, licensing, construction, operation and regulation of fusion installations that handle tritium:
- Design engineers and HVAC specialists developing confinement and ventilation systems for fusion fuel handling and fusion reactors.
- Nuclear safety and radiation protection engineers conducting risk assessments and safety classification.
- Facility operators and maintenance teams implementing operational controls, detritiation and filtration systems.
- Regulators and licensing authorities evaluating compliance with radiation protection and containment requirements.
- Architects and integrators planning layouts for hot cells, labs, waste treatment and emergency management centres.
Related Standards
EN ISO 16646 complements other national and international standards on radiation protection, nuclear facility safety, ventilation engineering and HVAC design. It was prepared by ISO/TC 85 and adopted by CEN as EN ISO 16646:2025 for harmonized application across CEN member states.
Keywords: EN ISO 16646, tritium, fusion installations, confinement and ventilation systems, detritiation, HEPA filters, radiation protection, tritium inventory, ventilation design.
Frequently Asked Questions
EN ISO 16646:2025 is a standard published by the European Committee for Standardization (CEN). Its full title is "Fusion installations - Criteria for the design and operation of confinement and ventilation systems of tritium fusion facilities and fusion fuel handling facilities (ISO 16646:2024)". This standard covers: This document specifies the applicable requirements related to the design and the operation of confinement and ventilation systems for fusion facilities for tritium fuels and tritium fuel handling facilities specific for fusion applications for peaceful purposes using high tritium inventories, as well as for their specialized buildings such as hot cells, examination laboratories, emergency management centres, radioactive waste treatment and storage facilities. In most countries, a tritium quantity is declared as high for tritium inventories higher than a range of 10 g to 100 g. In the tritium fusion facilities in the scope of this document, the tritium inventory is deemed to be higher than this range for the whole site. This document applies especially to confinement and ventilation systems that ensure the safety function of nuclear facilities involved in nuclear fusion with the goal to protect the workers, the public and the environment from the dissemination of radioactive contamination originating from the operation of these installations, and in particular from airborne tritium contamination with adequate confinement systems.
This document specifies the applicable requirements related to the design and the operation of confinement and ventilation systems for fusion facilities for tritium fuels and tritium fuel handling facilities specific for fusion applications for peaceful purposes using high tritium inventories, as well as for their specialized buildings such as hot cells, examination laboratories, emergency management centres, radioactive waste treatment and storage facilities. In most countries, a tritium quantity is declared as high for tritium inventories higher than a range of 10 g to 100 g. In the tritium fusion facilities in the scope of this document, the tritium inventory is deemed to be higher than this range for the whole site. This document applies especially to confinement and ventilation systems that ensure the safety function of nuclear facilities involved in nuclear fusion with the goal to protect the workers, the public and the environment from the dissemination of radioactive contamination originating from the operation of these installations, and in particular from airborne tritium contamination with adequate confinement systems.
EN ISO 16646:2025 is classified under the following ICS (International Classification for Standards) categories: 13.280 - Radiation protection; 27.120.20 - Nuclear power plants. Safety. The ICS classification helps identify the subject area and facilitates finding related standards.
You can purchase EN ISO 16646:2025 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CEN standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-2025
Fuzijske naprave - Merila za načrtovanje in delovanje zadrževalnih in
prezračevalnih sistemov v objektih za fuzijo tritija in objektih za ravnanje s
fuzijskim gorivom (ISO 16646:2024)
Fusion installations - Criteria for the design and operation of confinement and ventilation
systems of tritium fusion facilities and fusion fuel handling facilities (ISO 16646:2024)
Fusionsanlagen - Kriterien für die Auslegung und den Betrieb von Einschluss- und
Lüftungssystemen von Tritiumfusionsanlagen und Anlagen zur Handhabung von
Fusionsbrennstoff (ISO 16646:2024)
Installations de fusion - Critères pour la conception et l'exploitation des systèmes de
confinement et de ventilation des installations de fusion avec tritium et des installations
de traitement des combustibles de fusion (ISO 16646:2024)
Ta slovenski standard je istoveten z: EN ISO 16646:2025
ICS:
13.280 Varstvo pred sevanjem Radiation protection
27.120.20 Jedrske elektrarne. Varnost Nuclear power plants. Safety
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN ISO 16646
EUROPEAN STANDARD
NORME EUROPÉENNE
September 2025
EUROPÄISCHE NORM
ICS 13.280; 27.120.20
English Version
Fusion installations - Criteria for the design and operation
of confinement and ventilation systems of tritium fusion
facilities and fusion fuel handling facilities (ISO
16646:2024)
Installations de fusion - Critères pour la conception et Fusionsanlagen - Kriterien für die Auslegung und den
l'exploitation des systèmes de confinement et de Betrieb von Einschluss- und Lüftungssystemen von
ventilation des installations de fusion avec tritium et Tritiumfusionsanlagen und Anlagen zur Handhabung
des installations de traitement des combustibles de von Fusionsbrennstoff (ISO 16646:2024)
fusion (ISO 16646:2024)
This European Standard was approved by CEN on 22 September 2025.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2025 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 16646:2025 E
worldwide for CEN national Members.
Contents Page
European foreword . 3
European foreword
The text of ISO 16646:2024 has been prepared by Technical Committee ISO/TC 85 "Nuclear energy,
nuclear technologies, and radiological protection” of the International Organization for Standardization
(ISO) and has been taken over as EN ISO 16646:2025 by Technical Committee CEN/TC 430 “Nuclear
energy, nuclear technologies, and radiological protection” the secretariat of which is held by AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by March 2026, and conflicting national standards shall
be withdrawn at the latest by March 2026.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
Any feedback and questions on this document should be directed to the users’ national standards body.
A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of
North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and the
United Kingdom.
Endorsement notice
The text of ISO 16646:2024 has been approved by CEN as EN ISO 16646:2025 without any modification.
International
Standard
ISO 16646
First edition
Fusion installations — Criteria
2024-06
for the design and operation
of confinement and ventilation
systems of tritium fusion facilities
and fusion fuel handling facilities
Installations de fusion — Critères pour la conception et
l'exploitation des systèmes de confinement et de ventilation
des installations de fusion avec tritium et des installations de
traitement des combustibles de fusion
Reference number
ISO 16646:2024(en) © ISO 2024
ISO 16646:2024(en)
© ISO 2024
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii
ISO 16646:2024(en)
Contents Page
Foreword .v
Introduction .vi
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 General confinement specificities of tritium fusion facilities or fusion fuel handling
facilities . 7
4.1 General .7
4.2 Inventories to identify for fusion facilities confinement .9
4.3 Specific systems or loads used in fusion facilities .10
4.4 General description of confinement systems for fusion facilities .10
4.4.1 General .10
4.4.2 First confinement system . 13
4.4.3 Secondary confinement system .14
4.4.4 Fuel cycle systems . 15
4.4.5 Tritium material compatibility . 15
5 Functions and safety aspects for confinement and ventilation systems .15
5.1 General . 15
5.2 Main functions .16
5.3 General principles .17
5.4 Risk assessment procedure . .17
5.4.1 Preliminary analysis .17
5.4.2 Risk evaluation.19
5.4.3 Safety classification . 20
6 Architecture and description of the different confinement systems .21
6.1 General .21
6.2 Static confinement of radioactive material .21
6.2.1 Containment barriers and systems .21
6.2.2 Isolation function (static containment) .21
6.3 Ventilation of the volumes within the first confinement system . 23
6.3.1 General . 23
6.3.2 Vacuum vessel exhaust process . 23
6.3.3 Primary containment pressure limiter . 23
6.3.4 Local and/or centralised detritiation system .24
6.3.5 Ventilation of the volume between first and second containment barriers of the
first confinement system .24
6.3.6 Cryogenic systems .24
6.4 Ventilation of the volumes within the second confinement system . 25
6.4.1 General . 25
6.4.2 Rooms and building ventilation systems. 25
6.4.3 Detritiation systems . 25
6.4.4 Local ventilation systems . 26
6.4.5 Ventilation of the volumes located outside the secondary confinement . 26
6.4.6 Miscellaneous ventilation systems not connected with containment envelopes . 26
7 Requirements for the design of ventilation systems .27
7.1 General .27
7.2 Dynamic confinement .27
7.2.1 General .27
7.2.2 Classification of the installation into potentially contaminated areas
(confinement classification) . 28
7.2.3 Factors influencing the design of ventilation systems . 30
7.2.4 Negative pressure . 30
iii
ISO 16646:2024(en)
7.2.5 Air velocities between areas.31
7.2.6 Basic air pattern and clean-up systems .32
7.2.7 Classification into ventilation types . 33
7.2.8 Optimization of air exchanges . 33
7.2.9 Layout and location of the ventilation ducts .37
7.2.10 Elaboration of the ventilation diagram and calculation of the pressure drops .37
7.3 Filtration .37
7.3.1 General .37
7.3.2 HEPA filters . 38
7.3.3 Air detritiation system . 38
7.3.4 Other gas-trapping devices .41
8 Management of specific risks . 41
8.1 Control of combustible gases in the buildings.41
8.2 Control of cryogenic liquid/ gases in the buildings .42
8.3 Management of ambient conditions .42
8.3.1 Tritium airborne contamination .42
8.3.2 Air conditioning of safety-classified components .43
8.3.3 Ventilation systems of the control rooms .43
8.4 Prevention of risks linked to releases of heat, gases or toxic vapours . 44
8.5 Prevention of risks linked to the deposition of matter in ventilation ducts. 44
8.6 Prevention of fire hazard .45
8.6.1 Compartmentalization .45
8.6.2 Fire compartments (fire sectors) .45
8.6.3 Fire areas .47
8.6.4 Containment compartments .47
8.7 Consideration of external hazards . 48
9 Dispositions concerning the management and the operation of the ventilation systems .49
9.1 Organization and operating procedures . 49
9.2 Technical operating instructions . 49
9.3 Operational management issues .51
9.4 Test procedures and maintenance .51
9.4.1 General .51
9.4.2 Qualification .51
9.4.3 Pre-commissioning inspection tests .51
9.4.4 Acceptance tests .52
9.4.5 Commissioning tests .52
9.4.6 Maintenance and other periodic tests. 53
9.5 Monitoring of the confinement system . 54
9.6 Control of the ventilation system to prevent fire hazards . 55
9.6.1 General . 55
9.6.2 Fire control philosophy . 55
10 Instrumentation and Control (I&C) .57
10.1 Control .57
10.2 Instrumentation .57
10.3 Alarms . 58
Annex A (informative) Guidance on airborne contamination risks .59
Annex B (informative) Examples of detritiation technologies .66
Annex C (informative) Safety classification examples .68
Annex D (informative) Typical values for leak rates .70
Annex E (informative) Requirements for ventilation system air filters used in nuclear facilities .73
Bibliography .79
iv
ISO 16646:2024(en)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee
has been established has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely
with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types
of ISO document should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent
rights in respect thereof. As of the date of publication of this document, ISO had not received notice of (a)
patent(s) which may be required to implement this document. However, implementers are cautioned that
this may not represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO's adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 85, Nuclear energy, Subcommittee SC 2,
Radiological protection.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html
v
ISO 16646:2024(en)
Introduction
Confinement and ventilation systems implemented in fusion facilities using radioactive materials and
fusion fuel handling facilities ensure a safety function aiming at protecting the workers, the public and the
environment from the dissemination of radioactive contamination, including but not limited to tritium,
likely to be released from the operation of these installations.
This document applies specifically to confinement and ventilation systems for tritium fusion facilities
and fusion fuel handling facilities and their specific buildings (such as fuel handling facilities, hot cells,
examination laboratories, emergency management centres, radioactive waste treatment and storage
station).
In such fusion installations, tritium is particularly focused, as their tritium inventory may be high and as it
is likely to have a broader impact on workers, the environment or the members of the public than the other
radionuclides.
In most countries, a tritium quantity is declared as high for tritium inventories in a facility site higher than
a range of 10 g to 100 g. In the tritium fusion facilities in the scope of this document, the tritium inventory is
deemed to be much higher than this range for the whole facility site.
vi
International Standard ISO 16646:2024(en)
Fusion installations — Criteria for the design and operation
of confinement and ventilation systems of tritium fusion
facilities and fusion fuel handling facilities
1 Scope
This document specifies the applicable requirements related to the design and the operation of confinement
and ventilation systems for fusion facilities for tritium fuels and tritium fuel handling facilities specific for
fusion applications for peaceful purposes using high tritium inventories, as well as for their specialized
buildings such as hot cells, examination laboratories, emergency management centres, radioactive waste
treatment and storage facilities.
In most countries, a tritium quantity is declared as high for tritium inventories higher than a range of 10 g
to 100 g. In the tritium fusion facilities in the scope of this document, the tritium inventory is deemed to be
higher than this range for the whole site.
This document applies especially to confinement and ventilation systems that ensure the safety function
of nuclear facilities involved in nuclear fusion with the goal to protect the workers, the public and the
environment from the dissemination of radioactive contamination originating from the operation of these
installations, and in particular from airborne tritium contamination with adequate confinement systems.
The types of confinement systems for other facilities are covered by ISO 26802 for fission nuclear reactors,
by ISO 17873 for facilities other than fission nuclear reactors and by ISO 16647 for nuclear worksite and
for nuclear installations under decommissioning. The facilities covered by these three standards, notably
ISO 17873, include tritium as a radioactive material among the ones to be confined, but tritium is not their
driver of the risks for workers and for members of the public. Nevertheless, the tritium quantities and risks
from fusion facilities create specificities for a specific standard (e.g. in fusion facilities, tritium is the driver of
routine and accident consequences). Therefore, the scope of this document does not cover the other facilities
involved in tritium releases (ISO 17873, ISO 16647 and ISO 26802), even though these other facilities create
tritium releases (e.g. non-reactor fission facilities, tritium laboratories, tritium removal facilities from
fission plants, tritium defence facilities).
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
ISO 10648-2, Containment enclosures — Part 2: Classification according to leak tightness and associated
checking methods
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
ISO 16646:2024(en)
3.1
accidents
3.1.1
design basis accident
DBA
accident conditions against which a facility is designed according to established design criteria, and for
which the release of radioactive material is kept within authorized limits
[SOURCE: IAEA Nuclear Safety and Security Glossary (2022 interim edition)]
3.1.2
design extension conditions
DEC
postulated accident conditions not considered for design basis accidents, but considered in the design
process for the facility in accordance with best estimate methodology, and for which release of radioactive
material is kept within acceptable limits
[SOURCE: IAEA Nuclear Safety and Security Glossary (2022 interim edition)]
Note 1 to entry: This new IAEA expression has been introduced for upgrading existing facilities or designing new
facilities, following the occurrence of core melt accident situations in fission facilities. DEC cover the former situations,
that were in the past included in the Beyond Design Basis Accidents category, related to multiple failures in the facility
as well the ones that were supposed to create core melt and that are now supposed not to impact the containment of
the facility (and thus that would become a design condition for the confinement of the nuclear facility).
Note 2 to entry: For new fusion facilities using radioactive materials, this expression cover accidents scenarios that
were also considered as beyond design basis accidents for former designs, but that shall be considered in the design
process of the facility in order to limit radioactive releases within acceptable limits. For fusion facilities, examples of
DEC covered by this expression are the multiple failures scenarios (e.g. combination of loss of coolant events and loss
of vacuum accidents), explosion scenarios, generalised fire scenarios.
3.1.3
beyond-design basis accident
BDBA
postulated accident with accident conditions more severe than those of a design basis accident (3.1.1)
[SOURCE: IAEA Nuclear Safety and Security Glossary (2022 interim edition)]
Note 1 to entry: This expression was first used for fission reactors after the first core melt accident situations that
th
occurred in the 20 century, in order to identify the situations that were not considered in the design of the facility but
for which specific requirements should be considered to reduce the likelihood of fission reactors core melt situations as
well as the consequences of such situations, that are now covered by the IAEA expression “design extension conditions
(DEC)” (3.1.2). In the most recent years, for new facilities, BDBA cover only the accidents that are even beyond the DEC,
and that shall be practically eliminated.
Note 2 to entry: IAEA defines also severe accidents as “accident conditions more severe than a design basis accident
and involving significant core degradation”. In a fusion facility, there is no possibility of core degradation and therefore
this definition is not used.
3.2
aerosol
solid particles and liquid droplets of all dimensions in suspension in a gaseous fluid
3.3
air exchange rate
ratio between the ventilation air flow rate of a containment enclosure or a compartment, during normal
operating conditions, and the volume of this containment enclosure or compartment
-1 -1 -1
Note 1 to entry: The SI unit is s but the general usage is in d for leaktight volumes or in h for general ventilation.
ISO 16646:2024(en)
3.4
air conditioning
arrangements that allow sustaining a controlled atmosphere (temperature, humidity, pressure, dust levels,
gas content, etc.) in a defined volume, in order to ensure comfort of the personnel and/or the conditions for
adequate operation of safety systems used in fusion facility
3.5
balancing damper
control valve
adjustable device inserted in an aerodynamic duct allowing balancing of the fluid flow and/or the pressure
of the fluid during plant operation
3.6
barrier
physical obstruction that prevents or inhibits the movement of people, radionuclides or some other
phenomenon (e.g. fire), or provides shielding against radiation
[SOURCE: IAEA Nuclear Safety and Security Glossary (2022 interim edition)]
Note 1 to entry: In the context of this document regarding the confinement function, it concerns a structural element
that defines the physical limits of a volume with a particular radiological environment and that prevents or limits
releases of radioactive substances from this volume.
3.7
cell
shielded enclosure, shielding structure, of fairly large dimensions, possibly leak-tight
Note 1 to entry: See containment enclosure (3.10).
3.8
containment
confinement
arrangement allowing users to maintain separate environments inside and outside an enclosure, blocking
the movement between them of process materials and substances resulting from physical and chemical
reactions that are potentially harmful to workers, to the public, to the external environment, or for the
handled products
Note 1 to entry: the word containment is used for the leak-tight performances of a static physical barrier (3.6) confining
radioactive materials, whereas confinement is used for the global function of confining hazardous materials including
also the use of active systems ensuing a dynamic confinement (3.17). Therefore, confinement is used for the function
of preventing or controlling the releases of radioactive material to the environment in operation or in accidents.
Containment is used for the physical structures designed to prevent or control the release and the dispersion of
radioactive substances. In the context of facilities handling radioactive materials it covers structural elements (cans,
gloveboxes, storage cabinets, rooms, vaults, etc.), which are used to establish the physical integrity of an area.
3.9
containment compartment
CC
compartment of which the walls are able to contain radioactive substances that would be generated by any
plausible fire that breaks out in one of the fire compartments included
Note 1 to entry: It is often more practicable to limit the spread of a fire by using fire-resistant walls, and to prevent the
spread of contamination in the adjacent volumes.
3.10
containment enclosure
enclosure designed to prevent either the leakage of products contained in the pertinent internal environment
into the external environment, or the penetration of substances from the external environment into the
internal environment, or both simultaneously
Note 1 to entry: See cell (3.7).
ISO 16646:2024(en)
Note 2 to entry: This is a generic term used to designate all kinds of enclosures, including glove boxes, leak-tight
enclosures and shielded cells equipped with remotely operated devices.
3.11
containment envelope
volume allowing the enclosure, and thus the isolation from the environment, of those structures, systems
and components whose failure can lead to an unacceptable release of radionuclides
3.12
containment system
confinement system
system constituted of a coherent set of physical barriers (3.6) and/or dynamic systems intended to confine
radioactive substances in order to ensure the safety of the workers and the public and the protection of the
environment and to avoid releases of radioactive materials in the environment
Note 1 to entry: According to IAEA definitions, a containment system concerns the containment structure and the
associated systems with the functions of isolation, energy management, and control of radionuclides and combustible
gases. This containment system also protects the facility against external events and provides radiation shielding
during operational states and accident conditions. These two last functions are not described in this document, due to
the absence of link with the ventilation systems. In a fusion facility, the dynamic confinement (3.17) is more important
than in other facilities because of the tritium dispersion and permeation properties. Therefore, in fusion facilities, the
term confinement system is more generally used.
3.13
contamination
presence of radioactive substances on or in a material or a human body or any place where they are
undesirable or can be harmful
3.14
cubicle
generic term used to describe enclosures containing electrical equipment (power or instrumentation and
control) or cables
EXAMPLE Cabinets, junction boxes, switchboards.
3.15
decontamination factor
ratio of the contaminant concentration or particle number upstream of a filtration system to the contaminant
concentration or particle number downstream of the filtration system
Note 1 to entry: definition derived from ISO 29464:2017.
3.16
discharge stack
duct (usually vertical) at the termination of a system, from which the air is discharged to the atmosphere
after control and monitoring of contaminants
3.17
dynamic confinement
action allowing, by maintaining a preferential air flow circulation, the limitation of back-flow between two
areas or between the inside and outside of an enclosure, in order to prevent radioactive substances being
released from a given physical volume
3.18
event
any occurrence unintended by the operator, including operator error, equipment failure or other mishap,
and deliberate action on the part of others, the consequences or potential consequences of which are not
negligible from the point of view of protection and safety
[SOURCE: IAEA Nuclear Safety and Security Glossary (2022 interim edition)]
Note 1 to entry: In the context of this standard regarding the confinement function, the events are those challenging
the confinement function, whether the event is internal or external to the plant.
ISO 16646:2024(en)
Note 2 to entry: EXAMPLES of internal events for fusion type facilities are plasma events, human errors, loss of coolant
(LOCA), loss of vacuum (LOVA), loss of cryogenic inventories, electromagnetic loads, failures in steam piping systems,
leakage or failure of a system carrying radioactive fluid; fuel handling accident, loss of electrical power, drop loads,
internal missile, explosion, fire, and internal flooding.
Note 3 to entry: Examples of external events are aircraft crash, external explosion, earthquake, flood or drought,
winds and tornados, extreme temperature (high and low), human induced accidents, neighbouring facilities accidents,
external fires.
3.19
filter
device intended to trap particles suspended in gases or to trap gases themselves
Note 1 to entry: A particle filter consists of a filtering medium, generally made of a porous or fibrous material (glass
fibre or paper) fixed within a frame or casing. During the manufacturing process, the filter is mounted in a leak-tight
manner in this frame, using a lute. Gas or vapour filters are generally found in physical or chemical process units
where the primary aim is to trap certain gases. They cover in particular iodine traps (activated charcoal).
3.20
fire area
fire zone
volume comprising one or more rooms or spaces, surrounded by boundaries (geographical separation)
constructed to prevent the spreading of fire to or from the remainder building for a period of time allowing
the extinction of the fire
Note 1 to entry: It is often more practicable to limit the spread of a fire, and to prevent the spread of contamination in
the adjacent volumes by using fire-resistant walls (
...
La norme EN ISO 16646:2025 constitue un document fondamental pour la conception et l'exploitation des systèmes de confinement et de ventilation spécifiquement dédiés aux installations de fusion nucléaire utilisant du tritium. Son champ d'application est d'une grande importance, car il aborde des exigences spécifiques pour les installations manipulant des inventaires de tritium, alignées sur des applications pacifiques. La réglementation se concentre sur des installations où la quantité de tritium est considérée comme élevée, dépassant la plage de 10 g à 100 g, ce qui souligne la nécessité d'une approche rigoureuse en matière de sécurité. L'un des points forts de cette norme réside dans sa capacité à garantir la protection des travailleurs, du public et de l'environnement. En se focalisant sur les systèmes de confinement et de ventilation, EN ISO 16646:2025 vise à prévenir la dissémination de contaminants radioactifs, et en particulier de contamination aéroportée par le tritium. Cela est crucial pour le bon fonctionnement des cellules chaudes, des laboratoires d'examen, et des centres de gestion d'urgence, qui font partie intégrante des infrastructures des installations de fusion. De plus, la norme s'applique à des bâtiments spécialisés tels que ceux dédiés au traitement et au stockage des déchets radioactifs, renforçant ainsi la sécurité globale des opérations de fusion. L'approche systématique et détaillée de la norme permet de s'assurer que les systèmes de confinement sont non seulement efficaces mais aussi adaptés aux défis spécifiques rencontrés dans le domaine de la fusion nucléaire. La pertinence de la norme EN ISO 16646:2025 est accentuée par le besoin croissant de réglementations strictes dans un secteur aussi sensible que la fusion nucléaire. En intégrant des critères de conception avancés et des pratiques opérationnelles sûres, ce document sert de référence essentielle pour les concepteurs d’installations et les opérateurs, garantissant ainsi que les meilleures pratiques sont respectées pour le maniement du tritium et la sécurité des installations de fusion.
標準文書「EN ISO 16646:2025」は、トリチウム融合施設及びその燃料取扱い施設における閉じ込め及び換気システムの設計と運用に関する基準を定めており、その範囲は非常に専門的でありながら重要です。この文書では、平和的目的のために使用される高トリチウム在庫を有する融合施設に特有の設計要件が詳述されています。 その強みの一つは、トリチウム在庫が10gから100gを超える場合、特にその全体サイトにおいては高いとみなされる明確な基準を設けている点です。この明確な定義により、施設の設計および運用に関わる専門家は、トリチウムを含む環境での安全性を最大化するための具体的な措置を講じることができます。 さらに、この文書は、作業者や一般市民、環境を放射性汚染から保護するための便利な枠組みを提供しています。特に、空気中のトリチウム汚染からの保護を重視した閉じ込めシステムの設計基準は、原子力融合施設の安全機能を確保するために不可欠な要素です。 また、ホットセルや検査ラボ、緊急管理センター、放射性廃棄物処理及び保管施設などの専門的な建物に対する要求事項も含まれており、これらの施設が求める特定の条件に対して適切な指針を提供しています。 この「EN ISO 16646:2025」は、トリチウム関連の融合施設に関わる設計者や運営者が安全に業務を遂行するための信頼性の高い基準として位置付けられ、実効性の高い換気システムや閉じ込め技術の実装を促進することに寄与します。トリチウム取り扱い施設の安全基準の堅牢化へ向けて、非常に関連性の高い文書であると言えます。
Die Norm EN ISO 16646:2025 befasst sich mit den Anforderungen an die Planung und den Betrieb von Einschluss- und Belüftungssystemen in Fusionsanlagen, die Tritiumbrennstoffe und deren Handhabung betreffen. Ein zentraler Fokus dieser Norm liegt auf der Gewährleistung von Sicherheitsmaßnahmen, die sowohl die Mitarbeiter als auch die Öffentlichkeit und die Umwelt vor radioaktiver Kontamination schützen, insbesondere durch Luftverunreinigungen mit Tritium. Die Norm ist von großer Relevanz, da sie spezifische Kriterien für Fusionszentrifugen und Einrichtungen definiert, die in der friedlichen Nutzung von Kernfusionstechnologien tätig sind. Diese normative Grundlage legt grundlegende Schutzmaßnahmen fest, die für den Betrieb von Einrichtungen mit hohen Tritiumvorräten notwendig sind, welche in vielen Ländern als hoch angesehen werden, wenn sie 10 g bis 100 g übersteigen. Ein herausragendes Merkmal dieser Norm ist die umfassende Abdeckung der verschiedenen specialized buildings, die für die Sicherheit und Effizienz der Tritium-Fusionsanlagen essenziell sind, wie beispielsweise Hot Cells, Prüfungs- und Notfallmanagementzentren sowie Einrichtungen zur Behandlung und Lagerung von radioaktivem Abfall. Die Norm schafft somit eine solide Basis für die Gestaltung sicherer Arbeitsumgebungen in komplexen nuklearen Einrichtungen. Darüber hinaus legt die EN ISO 16646:2025 nicht nur technische Anforderungen fest, sondern gewährleistet auch, dass die eingesetzten Einschluss- und Belüftungssysteme effektiv arbeiten, um das Risiko einer Ausbreitung von radioaktiven Stoffen in die Umwelt zu minimieren. Diese Aspekte unterstreichen die Notwendigkeit dieser Norm für die Entwicklung von Technologien im Bereich der Umsatz der Kernfusion, was zu ihrer kontinuierlichen Bedeutung in Forschungs- und Industrieanwendungen beiträgt. Insgesamt ist die EN ISO 16646:2025 ein unverzichtbares Dokument für Fachleute im Bereich der Kernfusion, da es sowohl die betrieblichen Anforderungen als auch die sicherheitstechnischen Aspekte im Hinblick auf die Handhabung von Tritium klar definiert und somit ein hohes Maß an Sicherheit und Effizienz in Fusionsanlagen gewährleistet.
The EN ISO 16646:2025 standard provides an essential framework for the design and operation of confinement and ventilation systems in tritium fusion facilities. Its comprehensive scope covers requirements pertinent to high tritium inventories, specifically tailored for structures such as hot cells and examination laboratories, as well as emergency management centers and radioactive waste treatment facilities. One of the document's major strengths lies in its specific focus on tritium fuel handling, a critical aspect given the safety concerns surrounding high tritium inventories in fusion applications. By establishing criteria tailored to facilities that operate with significant tritium quantities, the standard ensures robust safety measures for both workers and the public, effectively mitigating the risks associated with airborne tritium contamination. Moreover, this standard emphasizes the importance of maintaining adequate confinement systems, ensuring that the potential for radioactive contamination is minimized. This is particularly relevant for fusion facilities aiming to uphold their commitment to peaceful applications of nuclear technology. The clear directives set forth in the document not only promote operational safety but also reinforce compliance with international safety norms. In essence, the EN ISO 16646:2025 standard is timely and highly relevant as it addresses the contemporary challenges faced by operators of fusion facilities. It equips them with the guidelines necessary to enhance their safety protocols while managing the inherent risks associated with tritium fusion practices. This makes it a pivotal reference for those involved in the design, operation, and management of fusion facilities and supports the overarching goal of environmental protection in the nuclear fusion sector.
표준 EN ISO 16646:2025는 트리튬 융합 시설 및 트리튬 연료 처리 시설의 격리 및 환기 시스템의 설계와 운영을 위한 기준을 제시합니다. 이 문서는 고농도의 트리튬 재고를 다루는 평화적인 목적의 융합 응용 프로그램에 특화된 격리 및 환기 시스템의 요구 사항을 상세히 설명하고 있습니다. 이 표준의 범위는 핫셀, 검사 실험실, 비상 관리 센터, 방사성 폐기물 처리 및 저장 시설 등 전문 건물에까지 확대됩니다. 이 표준의 강점은, 높은 트리튬 재고를 가질 경우 공공의 안전과 환경 보호를 위해 필수적인 충분한 격리 시스템을 구현하는 데 중점을 둔 점입니다. 특히, 트리튬 융합 시설의 운영과 관련하여 발생할 수 있는 공기 중의 방사성 오염 확산을 방지하기 위한 안전 기능을 강조하고 있습니다. 이러한 요구 사항은 직원, 대중 및 환경을 보호하는 데 중요한 역할을 하며, 따라서 매우 누리기 있는 자료로 평가됩니다. SIST EN ISO 16646:2025는 또한 트리튬 재고가 10g에서 100g을 초과하는 경우에 해당하는 나라에서 이 표준이 적용된다는 점에서 매우 실용적입니다. 이는 전 세계적으로 트리튬 융합 시설의 확산과 안전성을 보장하는 데 기여하는 중요한 기준으로 작용할 것입니다. 이러한 특성으로 인해, 이 문서는 융합 시설의 안전하고 효율적인 운용을 보장하기 위한 기술적인 지침으로서 큰 의미를 가지며, 업계 전반에서 필수적으로 참고해야 할 기준으로 자리 잡고 있습니다.










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...