FprEN ISO 16094-3
(Main)Water quality - Analysis of microplastic in water - Part 3: Thermo-analytical methods for waters with low content of suspended solids including drinking water (ISO/FDIS 16094-3:2026)
- Abstract
This document sets out key principles for the investigation of microplastics using thermo-analytical methods in water with low content of natural suspended solids.
This document gives requirements for the standardisation of methods towards harmonized procedures for determination of microplastics contents.
- Status
- Not Published
- Publication Date
- 10-Feb-2027
- Technical Committee
- CEN/TC 230 - Water analysis
- Drafting Committee
- CEN/TC 230 - Water analysis
- Current Stage
- 5060 - Closure of Vote - Formal Approval
- Start Date
- 10-Nov-2026
- Due Date
- 12-Feb-2025
- Completion Date
- 12-Feb-2025
FprEN ISO 16094-3 is a CEN draft aligned with ISO 16094-3 for water quality and microplastic analysis. It specifies thermo-analytical methods for waters with low content of natural suspended solids, including drinking water, so laboratories can identify polymer types and measure microplastic mass with harmonized procedures. The document is aimed at users who need comparable results for testing, monitoring, and risk assessment.
What does FprEN ISO 16094-3 specify?
FprEN ISO 16094-3 sets out the scope, principles, sample handling, analytical procedures, and reporting rules for microplastic analysis in low-solids water. It focuses on polymer identification and mass determination, not on particle size, shape, or particle number.
The document is organized into clauses for scope, normative references, terms and definitions, symbols and abbreviated terms, principle, materials, laboratory precautions, sample preparation, procedure, and test report, plus Annex A for example LOD/LOQ values.
Microplastics covered by the document include common polymers such as PE, PP, PET, and PS, with some additional polymers depending on the method and instrument setup. The practical point is that the method is designed for water where filtration residues and low background solids make thermo-analytical identification feasible.
What are the key requirements of FprEN ISO 16094-3?
FprEN ISO 16094-3 is built around a controlled workflow: filter the water sample, prepare the residue, analyze it by a GC-MS-based thermo-analytical method, and report the polymer mass with blanks and quality control. In practice, the method only works well when contamination control, sample preparation, and calibration are treated as part of the measurement.
Analytical principle and method choice
Clause 5 defines two GC-MS-based routes for bulk residues and one for isolated particles: TED-GC-MS and Py-GC-MS, with a separate Py-GC-MS route for picked particles. The document explains that the sample is thermally decomposed in an inert atmosphere, the decomposition products are separated by GC, and polymer-specific signals are identified and quantified by MS. For the reader, this means the analysis is chemistry-based, not image-based, and the result is a polymer-specific mass result.
Sample preparation and handling
Clause 8 requires filtration of the water sample and uses the filtration residue as the analytical sample. Drying to constant weight is part of preparation, and the document recommends limiting heat exposure so common plastics are not altered before analysis. For practice, this means the lab must control drying, weighing, and storage conditions so the residue remains representative.
Clause 8 also allows homogenisation of the dried residue when needed. That matters because the methods quantify polymers in the sampled material, not the original particle geometry, so careful homogenisation improves representativeness without changing the target result.
TED-GC-MS path
Clause 9.2 describes TED-GC-MS for filtration residues. It uses thermal extraction and desorption before GC-MS detection, and it supports internal standard use, marker-based identification, and three quantification approaches: response factors, standard addition, and matrix-related response factors. In practice, this route suits larger residue masses and laboratories that want a controlled bulk measurement.
Clause 9.2.4 also makes quality control central: instrument blanks, recovery checks, field blanks, and duplicate determinations are part of the method control. The document also states that PVC cannot be determined with TED-GC-MS in this context, which matters when the target polymer list includes PVC.
Py-GC-MS path for residues
Clause 9.3 covers Py-GC-MS for filtration residues. It addresses matrix effects, optional pre-treatment for organic matter, optional TMAH derivatisation, use of internal standards, and calibration by polymer mass. For the reader, this means the method is more flexible for small sample amounts, but the matrix and calibration strategy must be chosen carefully to keep results comparable.
Quality control in Clause 9.3 includes laboratory procedural blanks, field blanks, and replicate analysis when enough material is available. The document also links LOD and LOQ assessment to signal-to-noise practice and refers the user to Annex A for examples.
Analysis of isolated particles
Clause 9.4 describes Py-GC-MS for individual isolated particles picked from a filter. This route is intended for larger particles that can be visually selected and transferred into the analysis vessel, and the particle must be confirmed visually before analysis. The important practical point is that the particle itself is identified chemically, while the quantity can be obtained by weighing rather than by the GC-MS signal.
Reporting
Clause 10 requires the test report to identify the method used, the sample, the sampled water volume, the filter pore size, the analyzed sample mass, the quantification approach, the polymer-specific total mass, the number of repeat measurements, and the blanks used. This gives the reader a clear trail from water sample to reported polymer result, which is important for audits, comparisons, and regulatory use.
What terms does FprEN ISO 16094-3 define?
FprEN ISO 16094-3 defines the terms that control how the methods are interpreted and reported.
- Microplastic - a solid plastic or synthetic polymer particle insoluble in water in the microplastic size range; the term covers the sum of individual particles in a sample.
- Thermal analysis - a group of techniques in which a physical property is measured as temperature or time changes under a controlled temperature program.
- Pyrolysis - irreversible chemical decomposition caused by heating without oxidation; this is the basis of Py-GC-MS in the document.
- Degradation - an irreversible change in structure or properties that develops over time under environmental conditions.
- Thermal decomposition - chemical change caused by heat; the document distinguishes this from thermal degradation.
- GC-MS - gas chromatography-mass spectrometry, the separation and detection system used in both analytical routes.
- TED-GC-MS - thermal extraction desorption-gas chromatography-mass spectrometry, used for filtration residues.
- Py-GC-MS - pyrolysis-gas chromatography-mass spectrometry, used for filtration residues and isolated particles.
- ISTD - internal standard, used to normalize signal response and support quantification.
- CM - calibration material, the reference polymer material used for quantification.
Who uses FprEN ISO 16094-3?
FprEN ISO 16094-3 is used by laboratories that analyze drinking water and low-solids water for microplastics. It is also relevant to water quality teams, environmental monitoring organizations, and quality managers who need comparable results across samples, instruments, or sites.
In practice, users apply it for method selection, sample preparation, calibration, contamination control, and reporting. Buyers and technical evaluators can use it to judge whether a laboratory’s service is based on polymer-specific thermo-analytical measurement rather than visual counting.
The document is also relevant where results feed health and environmental risk assessment, because the introduction links standardized sampling and quantification to data reliability and comparability.
Which standards are used with FprEN ISO 16094-3?
FprEN ISO 16094-3 relies on several referenced standards to define terminology, laboratory conditions, and reference material practice.
- ISO 472:2013 - supplies plastics vocabulary and the source definition for thermal analysis and degradation terms.
- ISO 1043-1 - provides symbols and abbreviated terms for basic polymers.
- ISO 4880:1997 and ISO 8421-1:1987 - support vocabulary used for pyrolysis and related thermal terms.
- ISO 11074:2015 - contributes soil-quality vocabulary used for the thermal decomposition term source.
- ISO 11358 - gives general principles for thermogravimetry, which the document uses when describing TED-GC-MS sample heating.
- ISO 14644-1 - supports cleanroom and air-cleanliness concepts for contamination control.
- ISO 17034 GUIDE-30:33, 35 - supports characterization and assessment of homogeneity and stability for reference materials.
- ISO 24187 - provides general principles for analysis of microplastics in the environment.
What does the FprEN ISO 16094-3 document contain?
FprEN ISO 16094-3 contains procedural detail for contamination control, filtration residue preparation, thermal analysis, identification, quantification, and reporting. Clause 9 includes the practical workflows for TED-GC-MS, Py-GC-MS on residues, and Py-GC-MS on isolated particles.
The document also includes tables of example polymer decomposition products and marker ions, plus quality-control guidance for blanks, recovery, and calibration. Annex A gives example LOD and LOQ values and additional marker-ion examples for quantification under specific conditions.
In practice, the document is useful for designing a laboratory method, validating a workflow, checking analytical performance, and writing a defensible test report for microplastics in low-solids water.
Relations
- Effective Date
- 12-Feb-2026
Get Certified
Connect with accredited certification bodies for this standard
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Kiwa BDA Testing
Building and construction product certification.
Kmetijski inštitut Slovenije
Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.
Sponsored listings
Frequently Asked Questions
FprEN ISO 16094-3 is a draft published by the European Committee for Standardization (CEN). Its full title is "Water quality - Analysis of microplastic in water - Part 3: Thermo-analytical methods for waters with low content of suspended solids including drinking water (ISO/FDIS 16094-3:2026)". This standard covers: This document sets out key principles for the investigation of microplastics using thermo-analytical methods in water with low content of natural suspended solids. This document gives requirements for the standardisation of methods towards harmonized procedures for determination of microplastics contents.
This document sets out key principles for the investigation of microplastics using thermo-analytical methods in water with low content of natural suspended solids. This document gives requirements for the standardisation of methods towards harmonized procedures for determination of microplastics contents.
FprEN ISO 16094-3 is classified under the following ICS (International Classification for Standards) categories: 13.060.45 - Examination of water in general. The ICS classification helps identify the subject area and facilitates finding related standards.
FprEN ISO 16094-3 has the following relationships with other standards: It is inter standard links to ISO 16094-3. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
FprEN ISO 16094-3 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 microplastic
- 3.2 thermal analysis
- 3.3 pyrolysis
- 3.4 degradation
- 3.5 thermal decomposition
- 4 Symbols and abbreviated terms
- 5 Principle
- 6 Materials
- 6.1 Reagents/Consumables
- 6.2 Plastic reference material
- 7 Precautions for laboratory environment, apparatus and materials
- 7.1 Operating precautions for laboratory environment
- 7.2 Cleaning protocol for materials and equipment
- 8 Sample preparation: handling of samples before analysis
- 8.1 Filtration
- 8.2 Drying of filtration residues
- 8.3 Homogenisation of filtration residues
- 9 Procedure
- 9.1 General
- 9.2 Investigations of filtration residues from water using TED-GC-MS (Method 1)
- 9.3 Investigations of filtration residues from water using Py-GC-MS (Method 2)
- 9.4 Investigation of isolated particles using Py-GC-MS (Method 3)
- 10 Test report
- Annex A
- Bibliography
Introduction
Pollution linked to microplastics is recognised as a global phenomenon. The standardisation of the sampling, quantification and identification protocols is required to ensure reliability and comparability of the data produced for health and environmental risk assessments.
Microplastics in water can be identified and quantified using various methodological approaches. Depending on the measurement objectives, several complementary approaches shall be used to cover the full spectrum of microplastics (size and chemical nature). Table 1 summarises the characteristics and the information obtained with the thermo-analytical technics.
Table 1 — Characteristics of the various analytical techniques and information obtained Thermal Extraction Desorption Pyrolysis associated with Gas Chromatogassociated with Gas Chromatography raphy - Mass Spectrometry - Mass Spectrometry Type of Sample Water filtrate residue Isolated particles Chemical nature of the Yes polymer Information provided by Thermal decomposition products analytical technique Results expression Polymer type, mass Polymer type Minimum measurable size Undefined Visual identify-cation of particles Minimum mass subject to 0,1 – 2 µg 0,01 – 1 µg measurement after prepa- (absolute) (absolute) ration
oSIST prEN ISO 16094-3:2024
oSIST prEN ISO 16094-3:2024 DRAFT International Standard ISO/DIS 16094-3:2024(en) Water quality — Analysis of microplastic in water — Part 3:
Thermo-analytical methods for waters with low content of suspended solids including drinking water WARNING — Persons using this document should be familiar with normal laboratory practice. This document does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health practices. IMPORTANT — It is absolutely essential that tests conducted in accordance with this document be carried out by suitably qualified staff.
1 Scope
This document provides key principles for the analysis of microplastics in drinking water and water with low content of natural suspended solids using thermo-analytical methods. This document is applicable for the determination of types of polymers and mass of microplastics in the sample. This document is not applicable for the determination of particle size, particle shape and particle numbers. This document is applicable for the detection of microplastics in drinking water and waters with low content 1) of natural total suspended solids (TSS) .
NOTE However, the described detection procedures can also be applied to other sorts of samples. Whenever a laboratory applies this standard for detection of microplastics in water with higher contents of TSS than defined here, additional quality assessment and control (including preparation) is recommended to be applied to verify that detection methods are also appliccable for higher amounts of TSS. This standard describes the detection of different sort of polymers, which are the main ones (most used in industry and most abundant in the environment) being: polyethylene (PE), polypropylene (PP), polyethylene terephthalate (PET), and polystyrene (PS). These types of polymers can be analysed by all thermo-analytical methods. Depending on the used thermo-analytic methods, additional further polymer can be detected, such as polyvinylchloride (PVC), polycarbonate (PC), poly-methylmethacrylate (PMMA) polyamides (PA), 2) polyurethanes (PU) and as well as signals from PS-co-polymers .
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 472:2013, Plastics — Vocabulary ISO 1043-1, Plastics — Symbols and abbreviated terms — Part 1: Basic polymers and their special characteristics ISO 4880:1997, Burning behaviour of textiles and textile products — Vocabulary 1) ISO 6107 (1-100 mg/l) or lower if they interfere with determination; in future a reference to ISO 5667-27 is desirable, which is still under development.
2) Signals from PS-co-polymers can be derivate from tire wear and can be detect with the methods as well, but elastomers are outside the scope of this document.
oSIST prEN ISO 16094-3:2024 ISO/DIS 16094-3:2024(en) ISO 8421-1:1987, Fire protection — Vocabulary — Part 1: General terms and phenomena of fire ISO 11074:2015, Soil quality — Vocabulary ISO 11358, Plastics — Thermogravimetry (TG) of polymers — General principles ISO 14644-1, Cleanrooms and associated controlled environments — Part 1: Classification of air cleanliness by particle concentration ISO 17034 GUIDE-30:33, 35, Reference materials — Guidance for characterization and assessment of homogeneity and stability ISO 24187, Principles for the analysis of microplastics present in the environment
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 microplastic
any solid plastic or synthetic polymer particle insoluble in water with the largest dimension between 1 μm and 5 mm Note 1 to entry: Microplastics can show various shapes.
Note 2 to entry: This definition encompasses the ISO/TR 21960 definitions of large microplastics and microplastics. Note 3 to entry: The term “microplastics” covers the sum of several individual microplastic particles.
3.2 thermal analysis
group of techniques in which a physical property of a substance is measured as a function of temperature or time while the substance is subjected to a controlled temperature program Note 1 to entry: The adjective corresponding to “thermal analysis” is “thermo-analytical” (as in, for example, thermoanalytical techniques). Note 2 to entry: When two or more techniques are applied to the same test sample at the same time, they should be identified as “simultaneous multiple techniques”, for example simultaneous thermogravimetry and differential thermal analysis. The term “combined multiple techniques” would indicate the use of separate test samples for each technique.
[SOURCE: ISO 472:2013, 2.1160]
3.3 pyrolysis
irreversible chemical decomposition of a material due to an increase in temperature without oxidation [SOURCE: ISO 8421-1:1987, 1.44; ISO 4880:1997, 53; ISO 11074:2015, 6.4.33]
oSIST prEN ISO 16094-3:2024 ISO/DIS 16094-3:2024(en)
3.4 degradation
irreversible process leading to a significant change in the structure of a material, typically characterised by a change of properties (e.g. integrity, molecular mass or structure, mechanical strength) and/or by fragmentation, affected by environmental conditions, proceeding over a period of time and comprising one or more steps [SOURCE: ISO 472:2013, 2.262]
3.5 thermal decomposition
process whereby the action of heat or elevated temperature on an item causes changes in the chemical composition Note 1 to entry: “thermal decomposition” is not the same as “thermal degradation”. [SOURCE: ISO 472:2013, 2.1285]
4 Symbols and abbreviated terms
Table 2 — Polymers/polymeric materials ABS acrylonitrile butadiene styrene CM calibration material GC-MS gas chromatography – mass spectrometry GFF glass fibres filters LOD limit of detection LOQ limit of quantification ISTD internal standard m/z mass-to-change ratio PA polyamide (polymer of caprolactam = PA6, polymer of hexamethylenediamine and adipic acid = PA 66) PC polycarbonate PE polyethylene PET poly(ethylene terephthalate) PMMA poly(methyl methacrylate) PP polypropylene PS polystyrene PTFE polytetrafluoroethylene PUR -MDI polyurethane, based on methylene diphenyl diisocyanate PVC poly(vinyl chloride) Py-GC-MS pyrolysis-gas chromatography – mass spectrometry SBR styrene butadiene polymer S/N signal-to-noise ratio TED-GC-MS thermo extraction desorption-gas chromatography – mass spectrometry TMAH tetramethylammonium hydroxide TPU-MDI thermoplastic polyurethane, based on methylene diphenyl diisocyanate
5 Principle
All thermo-analytical techniques described in this document consist of different steps: pyrolysis, transfer/ separation and detection/quantification. In a first step, the samples are heated up in an inert atmosphere
oSIST prEN ISO 16094-3:2024 ISO/DIS 16094-3:2024(en) until decomposition (pyrolysis). In a second step, the resulting decomposition products are either directly separated on a GC column (pyrolysis GC-MS) or first selectively adsorbed/desorbed on a solid-phase material before they are introduced into the chromatographic system (TED-GC-MS). In a third step, polymer-specific decomposition products are detected and quantified (detection/quantification). The various techniques available differ in how these three steps are realised.
This document encompasses thermo-analytical techniques using gas chromatography/mass spectrometry (GC-MS) as separation and detection/quantification step. For microplastics detection, there are mainly two GC-MS-based techniques available:
- thermal extraction and desorption gas chromatography/mass spectrometry (TED-GC-MS).
- pyrolysis gas chromatography/mass spectrometry (Py-GC-MS).
In TED-GC-MS, a sample is heated up in a thermobalance (see ISO 11358) under a continuous nitrogen gas flow. At the outlet of the oven, a solid phase sorbent is located, collecting a part of the decomposition products of the sample. After this process the solid phase sorbent is transferred to a thermal desorption unit, in which the collected decomposition products are remobilised, trapped, re-focused and then transferred to the GC-MS system. A relatively large sample mass of filtration residues (5 mg to 100 mg) can be analysed with TED-GC-MS. In Py-GC-MS a sample is thermally decomposed at defined temperatures and under inert conditions. The volatile decomposition products are transferred via a high temperature split injector into a GC-MS system with optional cryo-trapping.
Using Py-GC-MS, only lower sample masses of filtration residues (< 1 mg) can be analysed. Therefore, when Py-GC-MS is applied, the investigated volume should be adjusted accordingly. Depending on the load of organic accompanying matrix, an additional sample preparation step can be analytically useful. However, in case of water samples with very low natural organic solids, no additional sample preparation is needed. The total mass of microplastic particles captured on filters shall be related to the total sample mass (i.e. µg/g), when reporting the microplastic content as a mass fraction. In case of water filtrate samples, the analysed (i.e. filtrated) volume can be used to express the microplastics concentration in terms of mass per volume (i.e. µg/l).
More detailed descriptions of the techniques and measurement parameters are provided in Clause 9.
6 Materials
6.1 Reagents/Consumables
Filter materials with appropriate pore size according to microplastic definition shall be made of inorganic material (glass fibres, alumina). When the filter is used for prefiltration also organic materials are possible (cellulose).
As possible cleaning or purge detergent the following solutions exists:
- Ultrapure water previously filtered using a filter (<1 µm pore size filters made of inorganic materials);
- Ethanol (a volume fraction of 10 % to 70 %) with water in the above described quality;
- pharmaceutical quality water / water for injections (water for the preparation of medicines for parenteral administration when water is used as a vehicle and for dissolving or diluting substances or preparations for parenteral administration.
6.2 Plastic reference material
For all thermo-analytical methods, polymers (pure reference materials, solved polymers or polymer powders with inorganic diluents) and ideally without significant amounts of additives or fillers are suitable as reference material (here named as calibration material, CM). Since thermo-analytical methods do not measure particle size, generally CM can be used in any form. However, homogeneous polymer powders (<
oSIST prEN ISO 16094-3:2024 ISO/DIS 16094-3:2024(en) 100 µm) that are easy to dose are particularly suitable and prevent size related effects on heat transfer. In some cases, aged polymers particles can be easier to handle (static charge, cryogenic grinding). However, dealing with environmental samples with a wide variety of possible and unknown polymer sources, the same decomposition products from one analytical sample can originate from different types of polymers (e.g. copolymers, polymer blends) and this type cannot be identified by further signals or additional sample preparation steps. In these cases, the results can be used for identification and clustering purposes. Quantification can only be related to the respective, defined basic pure polymer.
7 Precautions for laboratory environment, apparatus and materials
7.1 Operating precautions for laboratory environment
Since plastic is ubiquitous, the determination of identically procedural and instrument blank values is of decisive importance in addition to the examination of the environmental samples to correct the analysis results for possible foreign or secondary contamination. Especially in the case of very low plastic particle contamination, the blank values are decisive for the quality and significance of the analysis. It is recommended, that the space dedicated to the preparation of samples shall be plastic-free or the amount of plastic should be kept to a minimum (e.g. wall fabrics, flooring). Regular cleaning of the working environment is essential (for example hood, bench), suitable detergent or wipes (that do not destroy or degrade the laboratory working conditions or contaminate by further particles) shall be used. Ideally, the work will be done in laminar flow hood e.g. ISO 14644-1.
In particular, operators shall - wash hands (including gloves) before initiating the measurement procedure and at each critical step thereof, particularly after the external washing of the containers and when entering the premises dedicated to handling samples.
- wear a cotton laboratory coat or, if applicable, a clean antistatic laboratory coat, 100 % cotton textiles shall be used.
- when possible, avoid wearing protective polypropylene face masks.
- avoid wearing clothing made of synthetic fibres (e.g. fleece jackets, scarfs), personal hygiene or cosmetic products (e.g. abrasion of nail polish, presence of microplastics in foundations) liable to release microplastics in the work environment.
- ensure that any equipment or part of the body placed inside the laminar flow hood has undergone a decontamination step.
The laboratory shall ensure that the sample is protected from any contamination due to the working environment, particularly during the transport of the sample between the sample preparation and the detection station.
7.2 Cleaning protocol for materials and equipment
The use of plastic laboratory equipment in contact with the sample should be kept to a minimum. This includes containers and covers for sample storage, tubes for filtrations, filter holders or sealings. Where possible materials made of glass or metal shall be used Special care shall be taken not to contaminate glassware and metal items in contact with samples, including sample containers, vessels for pyrolysis experiments (i.e. crucibles, vials, quartz tubes or cups). The following procedures or steps shall be applied to those materials:
- Immerse the glass elements in a suitable detergent solution with sufficient contact time (e.g. 12 h). Then rinse the elements with an appropriate product (e.g. 70 % ethanol) and finish the rinsing with water filtrated using a filter made of inorganic materials with a pore size smaller than 1 µm.
oSIST prEN ISO 16094-3:2024 ISO/DIS 16094-3:2024(en) - Utensils containers shall be calcined in the oven at a minimum of 480 °C for 2 h or 450 °C for 6 h. This includes glass fibre filters (GFF).
- Quartz wool, used in particular to maintain samples in pyrolysis supports, shall be conditioned beforehand at a minimum temperature of 500 °C for at least 2 h. Unless the wool is guaranteed to be plastic free, this shall serve to minimise plastic contamination in the particularly critical pyrolysis unit.
- A possibility is also the treatment with open flame (Bunsen burner or similar) for 10 seconds as a cleaning protocol, especially when using tweezers in direct contact with microplastics.
- After cleaning, glassware and metal parts shall be stored in glass or metal containers or under a laminar flow hood. Contamination of particles can be minimised by storing glassware with aluminum foil or in glass Petri dishes.
8 Sample preparation: handling of samples before analysis
8.1 Filtration
This clause describes sample preparation steps of thermo-analytical methods which are mandatory for the detection of microplastics in drinking water and water with low suspended solids to avoid interferences. The analysis of water samples usually includes a filtration step to separate solid matter (particles) from the water. The conditions of filtration, including relevant mesh sizes are defined in ISO 16094-1. Alternatively, a selection of individual particles can be done by eye or under an optical microscope, using tweezers, which then are analysed individually.
8.2 Drying of filtration residues
Thermo-analytical methods analyse solid samples, this means, that in case of microplastic analysis of water, a water filtration residue using a meaningful sampling tool is analysed. Therefore, it is advisable to first dry the sample to determine a dry weight. Drying is also advantageous to avoid biological growth during longer storage. The drying process shall continue until the weight of the sample is constant. The duration until the weight is constant (measured under room conditions at 20 °C, 1,013 bar, e.g. ISO 1) depends on the source of the sample, the chemical composition and the temperature which is applied. Drying shall be carried out at room temperature up to a maximum of 40 °C, a temperature over 60 °C should be avoided, since above this temperature window conventional plastic types (PE, PP, PS, PET, PA, PVC) exhibit specific phase transitions (glass transition temperature, melting temperature) that are associated with altered decomposition mechanisms. With respect to larger amounts of sample material, the use of freeze drying helps to avoid agglomeration.
...