EN ISO 19076:2016
(Main)Leather - Measurement of leather surface - Using electronic techniques (ISO 19076:2016)
- Abstract
ISO 19076:2016 provides a method for the measurement of the surface of leather or leather parts by the use of electronic measuring machines.
It applies to the measurement of leather (or leather parts) fulfilling the following requirements:
- flexible leather, finished or unfinished, dry or wet leather;
- flexibility: such to allow full distension on the measuring line/surface.
- Status
- Withdrawn
- Publication Date
- 30-Aug-2016
- Withdrawal Date
- 17-Nov-2026
- Technical Committee
- CEN/TC 289 - Leather
- Drafting Committee
- CEN/TC 289/WG 3 - Fastness test methods
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 08-Feb-2023
Relations
- Effective Date
- 18-Jan-2023
- Effective Date
- 25-Aug-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Consolidated By
ISO 19076:2016 - Leather — Measurement of leather surface — Using electronic techniques - Effective Date
- 12-Feb-2026
Get Certified
Connect with accredited certification bodies for this standard

Control Union Certifications
Global certification for agriculture and sustainability.
Hohenstein Institut
Textile testing and certification.

Bureau Veritas Bangladesh
Bureau Veritas certification services in Bangladesh.
Sponsored listings
Frequently Asked Questions
EN ISO 19076:2016 is a standard published by the European Committee for Standardization (CEN). Its full title is "Leather - Measurement of leather surface - Using electronic techniques (ISO 19076:2016)". This standard covers: ISO 19076:2016 provides a method for the measurement of the surface of leather or leather parts by the use of electronic measuring machines. It applies to the measurement of leather (or leather parts) fulfilling the following requirements: - flexible leather, finished or unfinished, dry or wet leather; - flexibility: such to allow full distension on the measuring line/surface.
ISO 19076:2016 provides a method for the measurement of the surface of leather or leather parts by the use of electronic measuring machines. It applies to the measurement of leather (or leather parts) fulfilling the following requirements: - flexible leather, finished or unfinished, dry or wet leather; - flexibility: such to allow full distension on the measuring line/surface.
EN ISO 19076:2016 is classified under the following ICS (International Classification for Standards) categories: 59.140.30 - Leather and furs. The ICS classification helps identify the subject area and facilitates finding related standards.
EN ISO 19076:2016 has the following relationships with other standards: It is inter standard links to EN ISO 19076:2023, ISO 2588:2014, ISO 2419:2012, EN 15987:2022, EN ISO 13143-1:2016, EN ISO 14160:2011, EN ISO 13408-1:2011, EN ISO 13408-1:2015, EN ISO 14160:2021, ISO 19076:2016. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN ISO 19076:2016 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-november-2016
Usnje - Merjenje usnjene površine - Uporaba elektronskih tehnik (ISO 19076:2016)
Leather - Measurement of leather surface - Using electronic techniques (ISO
19076:2016)
Leder - Messung der Oberfläche des Leders - Elektronische Verfahren (ISO 19076:2016)
Cuir - Mesurage de la surface du cuir - Utilisation de techniques électroniques (ISO
19076:2016)
Ta slovenski standard je istoveten z: EN ISO 19076:2016
ICS:
59.140.30 Usnje in krzno Leather and furs
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN ISO 19076
EUROPEAN STANDARD
NORME EUROPÉENNE
August 2016
EUROPÄISCHE NORM
ICS 59.140.30
English Version
Leather - Measurement of leather surface - Using
electronic techniques (ISO 19076:2016)
Cuir - Mesurage de la surface du cuir - Utilisation de Leder - Messung der Oberfläche des Leders -
techniques électroniques (ISO 19076:2016) Elektronische Verfahren (ISO 19076:2016)
This European Standard was approved by CEN on 30 July 2016.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 19076:2016 E
worldwide for CEN national Members.
Contents Page
European foreword . 3
European foreword
This document (EN ISO 19076:2016) has been prepared by Technical Committee IULTCS “International
Union of Leather Technologists and Chemists Societies” in collaboration with Technical Committee
CEN/TC 289 “Leather” the secretariat of which is held by UNI.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by February 2017, and conflicting national standards
shall be withdrawn at the latest by February 2017.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent
rights.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
Endorsement notice
The text of ISO 19076:2016 has been approved by CEN as EN ISO 19076:2016 without any modification.
INTERNATIONAL ISO
STANDARD 19076
IULTCS/IUP 58
First edition
2016-08-15
Leather — Measurement of leather
surface — Using electronic techniques
Cuir — Mesurage de la surface du cuir — Utilisation de techniques
électroniques
Reference numbers
ISO 19076:2016(E)
IULTCS/IUP 58:2016(E)
©
ISO 2016
ISO 19076:2016(E)
IULTCS/IUP 58:2016(E)
© ISO 2016, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2016 – All rights reserved
ISO 19076:2016(E)
IULTCS/IUP 58:2016(E)
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 1
5 Apparatus and materials. 1
5.1 Measuring machine . 1
5.1.1 Machine design types . 1
5.1.2 Type A, B, and C measuring machines . 2
5.1.3 Type D measuring machine . 2
5.2 Reference calibrated templates for machine verification . 3
6 Sampling and conditioning . 3
7 General measurement criteria. 3
7.1 General requirement . 3
7.2 Leather orientation during measurement . 4
7.2.1 General. 4
7.2.2 Measuring whole leathers . 4
7.2.3 Measuring half leathers . 4
7.2.4 Measuring leather cut pieces . 4
7.3 Measurement operations . 4
7.3.1 Roller machines . 4
7.3.2 Conveyor machines . 4
7.3.3 Flatbed scanner machines and bi-dimensional static measuring devices . 5
8 Measurement procedure . 5
9 Calculation and expression of results . 6
10 Test report . 6
Annex A (normative) Calibrated templates for the verification of electronic measuring machines .7
Annex B (normative) Procedure for the verification of a measuring machine by
calibrated templates . 9
Annex C (normative) Laboratory record of calibrated templates .11
Annex D (informative) Repeatability and reproducibility .12
Bibliography .14
ISO 19076:2016(E)
IULTCS/IUP 58:2016(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity
assessment, as well as information about ISO’s adherence to the WTO principles in the Technical
Barriers to Trade (TBT) see the following URL: Foreword - Supplementary information
ISO 19076/IUP 58 was prepared by the Physical Test Commission of the International Union of Leather
Technologists and Chemists Societies (IUP Commission, IULTCS) in collaboration with the European
Committee for Standardization (CEN) Technical Committee CEN/TC 289, Leather, the secretariat of
which is held by UNI, in accordance with the agreement on technical co-operation between ISO and CEN
(Vienna Agreement).
IULTCS, originally formed in 1897, is a world-wide organization of professional leather societies to
further the advancement of leather science and technology. IULTCS has three Commissions, which
are responsible for establishing international methods for the sampling and testing of leather. ISO
recognizes IULTCS as an international standardizing body for the preparation of test methods for
leather.
iv © ISO 2016 – All rights reserved
ISO 19076:2016(E)
IULTCS/IUP 58:2016(E)
Introduction
Leather surface measuring equipment used within the European Union (EU) for legal metrology
applications are also subject to the EU Directive, 2004/22/EC, on measuring instruments.
ISO 19076:2016(E)
INTERNATIONAL STANDARD
IULTCS/IUP 58:2016(E)
Leather — Measurement of leather surface — Using
electronic techniques
1 Scope
This International Standard provides a method for the measurement of the surface of leather or leather
parts by the use of electronic measuring machines.
It applies to the measurement of leather (or leather parts) fulfilling the following requirements:
— flexible leather, finished or unfinished, dry or wet leather;
— flexibility: such to allow full distension on the measuring line/surface.
NOTE For tanned and pressed wet leather, the parties involved agree on the conditioning type. In case of
dispute, leather is to be conditioned according to the reference standard conditions in ISO 2419.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 2419, Leather — Physical and mechanical tests — Sample preparation and conditioning
ISO 2588, Leather — Sampling — Number of items for a gross sample
EN 15987, Leather — Terminology — Key definitions for the leather trade
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 15987 and the following apply.
3.1
relative feed
movement of relative translation between leather and the system
detecting its presence
4 Principle
The leather surface is measured by means of a measuring device provided with a linear or rectangular
array of uniformly-spaced electronic sensors, capable to detect leather presence and to integrate
the relevant information (as a sum of elementary rectangular areas). Precision data are available in
Annex D.
5 Apparatus and materials
5.1 Measuring machine
5.1.1 Machine design types
The measuring machines are built according to 4 basic types:
ISO 19076:2016(E)
IULTCS/IUP 58:2016(E)
Type A roller machines, where leather passes in front of the sensor array under guidance of a series of
free-rotating measuring rollers easing leather spread out by a light pressure on the sensor array, also
incorporating the feeding systems.
Type B conveyor machines, where leather is transported under the sensor array by cables or belts
mounted before and after the sensors themselves and substantially coplanar with them.
NOTE 1 This machine is more suitable for rigid leathers as the leather is transported on cables.
Type C flatbed scanning machines, with a horizontal plane surface (flatbed) where leather is laid flat,
and a “portal-shaped” frame containing the sensors; the frame is manually or mechanically moved, over
and parallel to the flatbed.
NOTE 2 This machine type is particularly used to measure the surface of small leathers or pieces of leather.
Type D bi-dimensional static measuring devices, based on the capture of a 2-dimension leather
image along the normal direction to the leather plane.
5.1.2 Type A, B, and C measuring machines
The measuring machine consists at least of:
— a base frame;
— a relative feed system between leather and measuring system;
— a set of sensors (sensor array) uniformly spaced along a direction normal to the feeding movement,
to detect leather presence;
— a processing system to integrate signals coming from the sensors array and from the feeding
movement sensing, as shown in Clause 4;
— a numerical indicator (display) of the leather surface measure, in metric units, with 0,1 dm
resolution with respect to the measured value. As an option, the machine may be equipped with a
stamping or printing system to record the surface measured value onto leather or onto a label.
The distance i between two adjacent sensors for the detection of leather presence shall not be greater
than 27 mm across the feeding direction.
Let p be the step of the leather presence detection along the feeding direction: the values of i and p shall
be such that their product i.p is not greater than 1/400 of the minimum measureable surface.
The feeding speed shall allow leather to spread out adequately during measurement.
NOTE 1 The machine is equipped with a feeding speed adjustment device to aid the fulfilment of this condition.
NOTE 2 In Type A and Type B machines the feeding speed can affect the spread out of the leather and
consequently the measuring uncertainty.
If the machine allows temporary feeding stop (e.g. by manual holding) during measurement, this shall
not significantly alter the measuring value.
Any feeding inversion, even partial and/or temporary, shall automatically cancel the measure, unless
the measuring system allows for the inversion in the area calculation. Such information shall be checked
in the instruction manual provided by the machine manufacturer.
5.1.3 Type D measuring machine
The measuring machine consists at least of:
— a base frame;
— a plane surface to spread and support leather;
2 © ISO 2016 – All rights reserved
ISO 19076:2016(E)
IULTCS/IUP 58:2016(E)
— a bi-dimensional image capturing system, with its optical axis normal to the leather surface;
— a system for image processing and leather surface calculation.
The leather surface corresponding to the elementary area measuring unit (pixel) shall not be greater
than 1/400 of the minimum measured surface.
EXAMPLE If the image capturing system is able to transfer a (2 m × 2 m) area into a (512 × 512) pixels array,
the surface corresponding to 1 pixel (elementary area) is:
(2 m/512) × (2 m/512) = 0,15 cm
The minimum measurable surface is therefore:
2 2 2
400 × 0,15 cm = 60 cm = 0,60 dm .
5.2 Reference calibrated templates for machine verification
Calibrated templates complying with Annex A requirements, such that the area of the calibrated
template is not less than 50 % of the area of the measured leather, or 1,4 m , whichever is smaller.
6 Sampling and conditioning
6.1 Batch sampling shall be according to
...