EN 554:1994
(Main)Sterilization of medical devices - Validation and routine control of sterilization by moist heat
Sterilization of medical devices - Validation and routine control of sterilization by moist heat
1.1 This European Standard specifies the requirements for the process development, validation, process control and monitoring of the sterilization of medical devices using moist heat. 1.2 The method is based on the monitoring of physical factors that cause the product to become sterile and presuppose that prior to validation the sterilizer and its installation comply with an appropriate specification. Note: Specifications for sterilizers are being prepared by CEN/TC 102. 1.3 This European Standard does not describe a quality assurance system for the control of all stages of manufacture. Note: Attention is drawn to the standards for quality systems (see EN 46001 or EN 46002) which control all stages of manufacture including the sterilization process. It is not a requirement of this standard to have a complete quality system during manufacture but certain elements of such a system are required and these are normatively referenced at appropriate places in the text. 1.4 This European Standard does not address the routine testing of samples (sterility testing) or the use of biological indicators as, except in a limited number of special applications, these practices are of limited value in moist heat sterilization. In such special applications, they should be regarded as additional to the measurement of physical parameters.
Sterilisation von Medizinprodukten - Validierung und Routineüberwachung für die Sterilisation mit feuchter Hitze
Diese europäische Norm legt die Anforderungen an die Verfahrensentwicklung, Validierung, Verfahrensregelung und Überwachung der Sterilisation von Medizin- produkten unter Verwendung von feuchter Hitze fest. Die Methode beruht auf der Überwachung der physikalischen Faktoren, die für die Sterilität des Produkts verantwortlich sind und setzt voraus, dass der Sterilisator und seine Installation vor der Validierung mit einer geeigneten Spezifikation übereinstimmen.
Stérilisation de dispositifs médicaux - Validation et contrôle de routine pour la stérilisation à la vapeur d'eau
La présente Norme Européenne spécifie les exigences concernant la mise au point, la validation et le contrôle et la surveillance du procédé de stérilisation des dispositifs médicaux à la vapeur. La méthode utilisée repose sur le contôle des facteurs physiques qui entrainent la stérilité du produit et elle présuppose que, avant la validation, le stérilisateur et son installation soientconformes à une spécification appropriée.
Sterilizacija medicinskih pripomočkov - Validacija in redni nadzor sterilizacije z vlažno toploto
General Information
- Status
- Withdrawn
- Publication Date
- 29-Jun-1994
- Withdrawal Date
- 14-Aug-2006
- Technical Committee
- CEN/TC 204 - Sterilization of medical devices
- Drafting Committee
- CEN/TC 204 - Sterilization of medical devices
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 15-Aug-2006
- Completion Date
- 15-Aug-2006
- Directive
- 93/42/EEC - Medical devices
Relations
- Effective Date
- 22-Dec-2008
Get Certified
Connect with accredited certification bodies for this standard

BSI Group
BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

TÜV Rheinland
TÜV Rheinland is a leading international provider of technical services.

TÜV SÜD
TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.
Sponsored listings
Frequently Asked Questions
EN 554:1994 is a standard published by the European Committee for Standardization (CEN). Its full title is "Sterilization of medical devices - Validation and routine control of sterilization by moist heat". This standard covers: 1.1 This European Standard specifies the requirements for the process development, validation, process control and monitoring of the sterilization of medical devices using moist heat. 1.2 The method is based on the monitoring of physical factors that cause the product to become sterile and presuppose that prior to validation the sterilizer and its installation comply with an appropriate specification. Note: Specifications for sterilizers are being prepared by CEN/TC 102. 1.3 This European Standard does not describe a quality assurance system for the control of all stages of manufacture. Note: Attention is drawn to the standards for quality systems (see EN 46001 or EN 46002) which control all stages of manufacture including the sterilization process. It is not a requirement of this standard to have a complete quality system during manufacture but certain elements of such a system are required and these are normatively referenced at appropriate places in the text. 1.4 This European Standard does not address the routine testing of samples (sterility testing) or the use of biological indicators as, except in a limited number of special applications, these practices are of limited value in moist heat sterilization. In such special applications, they should be regarded as additional to the measurement of physical parameters.
1.1 This European Standard specifies the requirements for the process development, validation, process control and monitoring of the sterilization of medical devices using moist heat. 1.2 The method is based on the monitoring of physical factors that cause the product to become sterile and presuppose that prior to validation the sterilizer and its installation comply with an appropriate specification. Note: Specifications for sterilizers are being prepared by CEN/TC 102. 1.3 This European Standard does not describe a quality assurance system for the control of all stages of manufacture. Note: Attention is drawn to the standards for quality systems (see EN 46001 or EN 46002) which control all stages of manufacture including the sterilization process. It is not a requirement of this standard to have a complete quality system during manufacture but certain elements of such a system are required and these are normatively referenced at appropriate places in the text. 1.4 This European Standard does not address the routine testing of samples (sterility testing) or the use of biological indicators as, except in a limited number of special applications, these practices are of limited value in moist heat sterilization. In such special applications, they should be regarded as additional to the measurement of physical parameters.
EN 554:1994 is classified under the following ICS (International Classification for Standards) categories: 11.080 - Sterilization and disinfection. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 554:1994 has the following relationships with other standards: It is inter standard links to EN ISO 17665-1:2006. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 554:1994 is associated with the following European legislation: EU Directives/Regulations: 90/385/EEC, 93/42/EEC; Standardization Mandates: M/BC/CEN/89/9. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 554:1994 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2000
6WHULOL]DFLMDPHGLFLQVNLKSULSRPRþNRY9DOLGDFLMDLQUHGQLQDG]RUVWHULOL]DFLMH]
YODåQRWRSORWR
Sterilization of medical devices - Validation and routine control of sterilization by moist
heat
Sterilisation von Medizinprodukten - Validierung und Routineüberwachung für die
Sterilisation mit feuchter Hitze
Stérilisation de dispositifs médicaux - Validation et contrôle de routine pour la stérilisation
a la vapeur d'eau
Ta slovenski standard je istoveten z: EN 554:1994
ICS:
11.080.01 Sterilizacija in dezinfekcija na Sterilization and disinfection
splošno in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...