Gas-fired central heating boilers - Type B11 and B11BS boilers fitted with atmospheric burners of nominal heat input not exceeding 70 kW

This European Standard specifies the requirements and test methods for the construction, safety, fitness for purpose, rational use of energy, classification and marking of gas-fired central heating boilers, hereafter referred to as 'boilers'.  This standard applies to type B11 and BB11BS boilers:  - fitted with atmospheric burners; - that use gases corresponding to the three gas families and to the pressures   stated in 4.1.4; - that have a nominal heat input not exceeding 70 kW (on net calorific value); - where the temperature of the water does not exceed 95 øC during normal   operation; - where the maximum water-side operating pressure does not exceed 6 bar.  This standard does not contain all the necessary requirements for:  boilers:  - intended to be installed in the open; - having multiple heating units with a single draught diverter; - with fan-assisted combustion; - of the condensing type; i- ntended to be connected to a common flue having mechanical extraction; - fitted with manual or automatic means of adjusting the air supply and/or   adjusting the evacuation of the combustion products; - of the combination type (central heating and domestic hot water production);  appliances:  - combining the functions of an independent space heater and a hot water   generator for central heating.  This standard only covers type testing.

Heizkessel für gasförmige Brennstoffe - Heizkessel des Typs B11 und B11BS mit atmosphärischen Brennern mit einer Nennwärmebelastung kleiner als oder gleich 70 kW

Die vorliegende europäische Norm legt die Anforderungen und Prüfungen für den Bau, die Sicherheit, die Gebrauchsgüte und den sparsamen Energieeinsatz, die Einteilung und die Kennzeichnung von Heizkesseln fest, die mit atmosphärischen Brennern ausgerüstet sind und mit gasförmigen Brennstoffen betrieben werden (nachfolgend kurz Kessel genannt).

Chaudières de chauffage central utilisant les combustibles gazeux - Chaudières des types B11 et B11BS equipées de brûleurs atmosphériques dont le débit calorifique nominal est inférieur ou égal à 70 kW

La présente norme européenne définit les spécifications et les techniques d'essais relatives à la construction, la sécurité, l'aptitude à la fonction, l'utilisation rationnelle de l'énergie, la classification et le marquage des chaudières de chauffrage central utilisant les combustibles gazeux, appelées ci-après "chaudières".

Plinski kotli za centralno ogrevanje - Tipa B <+>11<+> and B<+>11BS<+> z atmosferskimi gorilniki z imensko močjo do vključno 70 kW

General Information

Status
Withdrawn
Publication Date
23-May-1994
Withdrawal Date
20-Jan-2026
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
30-Jul-2014
Completion Date
28-Jan-2026

Relations

Effective Date
06-Aug-2014
Effective Date
28-Jan-2026
Effective Date
08-Jun-2022
Effective Date
08-Jun-2022
Effective Date
08-Jun-2022
Effective Date
08-Jun-2022
Effective Date
08-Jun-2022
Effective Date
08-Jun-2022

Get Certified

Connect with accredited certification bodies for this standard

ICC Evaluation Service

Nonprofit organization that performs technical evaluations of building products.

ANAB United States Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

BBA (British Board of Agrément)

UK construction product certification.

UKAS United Kingdom Verified

Sponsored listings

Frequently Asked Questions

EN 297:1994 is a standard published by the European Committee for Standardization (CEN). Its full title is "Gas-fired central heating boilers - Type B11 and B11BS boilers fitted with atmospheric burners of nominal heat input not exceeding 70 kW". This standard covers: This European Standard specifies the requirements and test methods for the construction, safety, fitness for purpose, rational use of energy, classification and marking of gas-fired central heating boilers, hereafter referred to as 'boilers'. This standard applies to type B11 and BB11BS boilers: - fitted with atmospheric burners; - that use gases corresponding to the three gas families and to the pressures stated in 4.1.4; - that have a nominal heat input not exceeding 70 kW (on net calorific value); - where the temperature of the water does not exceed 95 øC during normal operation; - where the maximum water-side operating pressure does not exceed 6 bar. This standard does not contain all the necessary requirements for: boilers: - intended to be installed in the open; - having multiple heating units with a single draught diverter; - with fan-assisted combustion; - of the condensing type; i- ntended to be connected to a common flue having mechanical extraction; - fitted with manual or automatic means of adjusting the air supply and/or adjusting the evacuation of the combustion products; - of the combination type (central heating and domestic hot water production); appliances: - combining the functions of an independent space heater and a hot water generator for central heating. This standard only covers type testing.

This European Standard specifies the requirements and test methods for the construction, safety, fitness for purpose, rational use of energy, classification and marking of gas-fired central heating boilers, hereafter referred to as 'boilers'. This standard applies to type B11 and BB11BS boilers: - fitted with atmospheric burners; - that use gases corresponding to the three gas families and to the pressures stated in 4.1.4; - that have a nominal heat input not exceeding 70 kW (on net calorific value); - where the temperature of the water does not exceed 95 øC during normal operation; - where the maximum water-side operating pressure does not exceed 6 bar. This standard does not contain all the necessary requirements for: boilers: - intended to be installed in the open; - having multiple heating units with a single draught diverter; - with fan-assisted combustion; - of the condensing type; i- ntended to be connected to a common flue having mechanical extraction; - fitted with manual or automatic means of adjusting the air supply and/or adjusting the evacuation of the combustion products; - of the combination type (central heating and domestic hot water production); appliances: - combining the functions of an independent space heater and a hot water generator for central heating. This standard only covers type testing.

EN 297:1994 is classified under the following ICS (International Classification for Standards) categories: 91.140.10 - Central heating systems. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 297:1994 has the following relationships with other standards: It is inter standard links to EN 15502-2-2:2014, EN 14459:2007, EN 297:1994/A6:2003, EN 297:1994/A2:1996, EN 297:1994/A4:2004, EN 297:1994/A3:1996, EN 297:1994/A5:1998, EN 297:1994/A2:1996/AC:2006. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 297:1994 is associated with the following European legislation: EU Directives/Regulations: 2009/142/EC, 90/396/EEC; Standardization Mandates: M/BC/CEN/89/6. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 297:1994 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Heizkessel für gasförmige Brennstoffe - Heizkessel des Typs B11 und B11BS mit atmosphärischen Brennern mit einer Nennwärmebelastung kleiner als oder gleich 70 kWChaudieres de chauffage central utilisant les combustibles gazeux - Chaudieres des types B11 et B11BS equipées de bruleurs atmosphériques dont le débit calorifique nominal est inférieur ou égal a 70 kWGas-fired central heating boilers - Type B11 and B11BS boilers fitted with atmospheric burners of nominal heat input not exceeding 70 kW97.100.20Plinski grelnikiGas heaters91.140.10Sistemi centralnega ogrevanjaCentral heating systemsICS:Ta slovenski standard je istoveten z:EN 297:1994SIST EN 297:1997en01-marec-1997SIST EN 297:1997SLOVENSKI
STANDARD
SIST E
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...