Workplace atmospheres - Pumped sorbent tubes for the determination of gases and vapours - Requirements and test methods

This European Standard specifies performance requirements and test methods under   prescribed laboratory conditions for a sorbent tube used in conjunction with an air sampling pump for the determination of gases and vapours in workplace atmospheres.  Annexes recommend additional tests designed to establish whether the performance characteristics of the sampler are affected by a wider range of environmental influences.  If a sampler cannot comply with these specifications,   its range of applicability needs to be determined and quoted.

Arbeitsplatzatmosphäre - Pumpenbetriebene Sammelröhrchen zur Bestimmung von Gasen und Dämpfen - Anforderungen und Prüfverfahren

Diese Europäische Norm ist anwendbar für Sammenlröhrchen, die zur Bestimmung der Konzentration von Gasen und Dämpfen in Arbeitsbereichen verwendet werden und bei denen die Probenahme mit Hilfe einer Luftsammel-Pumpe vorgenommen wird. Diese Europäische Norm ist anwendbar für Sammelröhrchen, zur indirekten Konzentrationsbestimmung durch Sammlung und Analyse in getrennten     Schritten. Diese Sammelröhrchen können eingeteilt werden in: - Sammelröhrchen Typ A, die auf einer Sorption an einer festen Phase und Desorpt. durch ein Lösemittel beruhen; mit nachfolgender Analyse des Desorbats.

Atmosphères des lieux de travail - Tubes à adsorption avec pompage pour la détermination des gaz et vapeurs - Exigences et méthodes d'essai

La présente Norme Européenne spécifie les exigences de performance et les méthodes d'essai, dans des conditions de laboratoire prescrites, pour un tube à absorption employé conjointement à une pompe d'échantillonnage d'air pour la détermination des gaz et des vapeurs dans l'air des lieux de travail.  Les annexes préconisent des essais supplémentaires conçus pour établir si les caractéristiques de performance de l'échantillonneur sont affectées par des influences d'environnement plus variées.  Si un échantilloneur ne peut être conforme à ces spécifications, son degré d'application doit être déterminé.

Zrak na delovnem mestu - Cevke z adsorpcijskim polnilom za določevanje plinov in par - Zahteve in preskusne metode

General Information

Status
Withdrawn
Publication Date
20-May-1997
Withdrawal Date
01-Dec-2009
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
02-Dec-2009
Completion Date
02-Dec-2009

Relations

Effective Date
08-Jun-2022
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
08-Jun-2022

Get Certified

Connect with accredited certification bodies for this standard

NSF International

Global independent organization facilitating standards development and certification.

ANAB United States Verified

CIS Institut d.o.o.

Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

SA Slovenia Verified

Kiwa BDA Testing

Building and construction product certification.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

EN 1076:1997 is a standard published by the European Committee for Standardization (CEN). Its full title is "Workplace atmospheres - Pumped sorbent tubes for the determination of gases and vapours - Requirements and test methods". This standard covers: This European Standard specifies performance requirements and test methods under prescribed laboratory conditions for a sorbent tube used in conjunction with an air sampling pump for the determination of gases and vapours in workplace atmospheres. Annexes recommend additional tests designed to establish whether the performance characteristics of the sampler are affected by a wider range of environmental influences. If a sampler cannot comply with these specifications, its range of applicability needs to be determined and quoted.

This European Standard specifies performance requirements and test methods under prescribed laboratory conditions for a sorbent tube used in conjunction with an air sampling pump for the determination of gases and vapours in workplace atmospheres. Annexes recommend additional tests designed to establish whether the performance characteristics of the sampler are affected by a wider range of environmental influences. If a sampler cannot comply with these specifications, its range of applicability needs to be determined and quoted.

EN 1076:1997 is classified under the following ICS (International Classification for Standards) categories: 13.040.30 - Workplace atmospheres. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 1076:1997 has the following relationships with other standards: It is inter standard links to EN 1076:2009, EN 14042:2003, EN ISO 16017-1:2000, EN 1076:1997/AC:1997. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 1076:1997 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Arbeitsplatzatmosphäre - Pumpenbetriebene Sammelröhrchen zur Bestimmung von Gasen und Dämpfen - Anforderungen und PrüfverfahrenAtmospheres des lieux de travail - Tubes a adsorption avec pompage pour la détermination des gaz et vapeurs - Exigences et méthodes d'essaiWorkplace atmospheres - Pumped sorbent tubes for the determination of gases and vapours - Requirements and test methods13.040.30Kakovost zraka na delovnem mestuWorkplace atmospheresICS:Ta slovenski standard je isto
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...