Standard Practice for Determining the Stability and Miscibility of a Solid, Semi-Solid, or Liquid Waste Material

SIGNIFICANCE AND USE
5.1 This practice will identify waste materials that are potentially unstable when they come in contact with other materials at a waste treatment or disposal site.  
5.2 This practice will serve to determine the miscibility of waste materials with various media, including other wastes.  
5.3 This practice may not be applicable to all wastes. The appropriateness of these tests depends upon the proposed management of the waste.  
5.4 Since the initiation of some chemical reactions are slow to take place, the user may wish to establish reagent-to-waste contact times prior to observing the mixes for any reactions.
SCOPE
1.1 This practice is designed to determine whether a waste material reacts when it is mixed with air, water, strong acid, strong base, an oil/solvent mixture, other waste mixtures, or solid media such as a geological formation or solidification agents.  
1.2 The miscibility of the waste material with the above media can also be defined.  
Note 1: The following ASTM standards provide supplemental information: Test Methods D4978, D4980, D4982, D5049, and D5057 and Practices D4979, D4981, and D5058.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Aug-2019
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D5232-19 - Standard Practice for Determining the Stability and Miscibility of a Solid, Semi-Solid, or Liquid Waste Material
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D5232-19 - Standard Practice for Determining the Stability and Miscibility of a Solid, Semi-Solid, or Liquid Waste Material
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D5232 − 19
Standard Practice for
Determining the Stability and Miscibility of a Solid, Semi-
1
Solid, or Liquid Waste Material
This standard is issued under the fixed designation D5232; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope D4979 Practice for Physical Description ScreeningAnalysis
in Waste
1.1 This practice is designed to determine whether a waste
D4980 Test Methods for Screening of pH in Waste (With-
material reacts when it is mixed with air, water, strong acid,
3
drawn 2009)
strong base, an oil/solvent mixture, other waste mixtures, or
D4981 Practice for Screening of Oxidizers in Waste
solid media such as a geological formation or solidification
D4982 Test Methods for Flammability Potential Screening
agents.
Analysis of Waste
1.2 The miscibility of the waste material with the above
D5049 Test Method for Screening Cyanides InWaste (With-
media can also be defined. 3
drawn 1999)
D5057 TestMethodforScreeningApparentSpecificGravity
NOTE 1—The following ASTM standards provide supplemental infor-
mation: Test Methods D4978, D4980, D4982, D5049, and D5057 and
and Bulk Density of Waste
Practices D4979, D4981, and D5058.
D5058 Practices for Compatibility of Screening Analysis of
1.3 The values stated in SI units are to be regarded as Waste
D5681 Terminology for Waste and Waste Management
standard. No other units of measurement are included in this
standard.
3. Terminology
1.4 This standard does not purport to address all of the
3.1 Definitions of terms in this practice appear in Terminol-
safety concerns, if any, associated with its use. It is the
ogy D5681.
responsibility of the user of this standard to establish appro-
priate safety, health, and environmental practices and deter- 4. Summary of Practice
mine the applicability of regulatory limitations prior to use.
4.1 The stability and miscibility of a waste material are
For specific hazard statements, see Section 8.
observed when the waste is mixed with various media.
1.5 This international standard was developed in accor-
5. Significance and Use
dance with internationally recognized principles on standard-
ization established in the Decision on Principles for the
5.1 This practice will identify waste materials that are
Development of International Standards, Guides and Recom-
potentially unstable when they come in contact with other
mendations issued by the World Trade Organization Technical
materials at a waste treatment or disposal site.
Barriers to Trade (TBT) Committee.
5.2 This practice will serve to determine the miscibility of
waste materials with various media, including other wastes.
2. Referenced Documents
2 5.3 This practice may not be applicable to all wastes. The
2.1 ASTM Standards:
appropriateness of these tests depends upon the proposed
D1193 Specification for Reagent Water
management of the waste.
D4978 Test Methods for Screening of Reactive Sulfides in
5.4 Since the initiation of some chemical reactions are slow
Waste
to take place, the user may wish to establish reagent-to-waste
contact times prior to observing the mixes for any reactions.
1
This practice is under the jurisdiction of ASTM Committee D34 on Waste
Management and is the direct responsibility of Subcommittee D34.01.06 on
6. Apparatus and Materials
Analytical Methods.
6.1 Disposable Cups, minimum 40-mL total volume. Select
Current edition approved Sept. 1, 2019. Published September 2019. Originally
approved in 1992. Last previous edition approved in 2013 as D5232 – 13. DOI:
plastics or other materials compatible with the reagents in-
10.1520/D5232-19.
volved.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on The last approved version of this historical standard is referenced on
the ASTM website. www.astm.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D5232 − 19
6.2 Stirring Rods, Spatulas, Disposal Droppers, Watch 9.3.1 Mix liquid waste sample thoroughly, and place a
Glasses, and so forth. 10-mL aliquot of the sample in a 40-mL plastic cup. For dry
waste or sludges, add enough sample to fill the cup to the
6.3 Other waste materials to be evaluated with the test
10-mL mark.
sample.
9.3.2 P
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D5232 − 13 D5232 − 19
Standard Test Method Practice for
Determining the Stability and Miscibility of a Solid, Semi-
1
Solid, or Liquid Waste Material
This standard is issued under the fixed designation D5232; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method is designed to determine whether a waste material reacts when it is mixed with air, water, strong acid,
strong base, an oil/solvent mixture, other waste mixtures, or solid media such as a geological formation or solidification agents.
1.2 The miscibility of the waste material with the above media can also be defined.
NOTE 1—The following ASTM standards provide supplemental information: Test Methods D4978, D4979, D4980, D4981, D4982, D5049, D5057, and
D5058.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use. For specific hazard statements, see Section 8.
2. Referenced Documents
2
2.1 ASTM Standards:
D1193 Specification for Reagent Water
D4978 Test Methods for Screening of Reactive Sulfides in Waste
D4979 Practice for Physical Description Screening Analysis in Waste
3
D4980 Test Methods for Screening of pH in Waste (Withdrawn 2009)
D4981 Practice for Screening of Oxidizers in Waste
D4982 Test Methods for Flammability Potential Screening Analysis of Waste
3
D5049 Test Method for Screening Cyanides In Waste (Withdrawn 1999)
D5057 Test Method for Screening Apparent Specific Gravity and Bulk Density of Waste
D5058 Practices for Compatibility of Screening Analysis of Waste
D5681 Terminology for Waste and Waste Management
3. Terminology
3.1 Definitions of terms in this test method appear in Terminology D5681.
4. Summary of Test Method
4.1 The stability and miscibility of a waste material are observed when the waste is mixed with various media.
5. Significance and Use
5.1 This test method will identify waste materials that are potentially unstable when they come in contact with other materials
at a waste treatment or disposal site.
5.2 This test method will serve to determine the miscibility of waste materials with various media, including other wastes.
1
This test method practice is under the jurisdiction of ASTM Committee D34 on Waste Management and is the direct responsibility of Subcommittee D34.01.06 on
Analytical Methods.
Current edition approved April 1, 2013Sept. 1, 2019. Published May 2013September 2019. Originally approved in 1992. Last previous edition approved in 20082013 as
D5232 – 92 (2008).D5232 – 13. DOI: 10.1520/D5232-13. 10.1520/D5232-19.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
The last approved version of this historical standard is referenced on www.astm.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D5232 − 19
5.3 This test method may not be applicable to all wastes. The appropriateness of these tests depends upon the proposed
management of the waste.
5.4 Since the initiation of some chemical reactions are slow to take place, the user may wish to establish reagent-to-waste
contact times prior to observing the mixes for any reactions.
6. Apparatus and Materials
6.1 Disposable Cups, minimum 40-mL total volume. Select plastics or other materials compatible with the reagents involved.
6.2 Stirring Rods, Spatulas, Disposal Droppers, Watch Glasses, and so forth.
6.3 Other waste materials to be evaluated with the test sample.
6.4 Solid Media, to be evaluated with the test sample.
7. Reagents
7.1 Purity of Water—The deionized water used to prepare the aqueous test solutions should conform to the conductivity
specifications of ASTM Type II water as found in Specification D1193.
7.2 Hydrochloric Acid (HCl) Test Solution, carefully mix 100 g of reag
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.